Abstract: This paper expounds on the direct-driven PMSG wind power system control strategy, and analyses the stability conditions of the system. The direct-driven PMSG wind power system may generate the intense mechanical vibration, when wind speed changes dramatically. This paper proposes a new type of torque control strategy, which increases the system damping effectively, mitigates mechanical vibration of the system, and enhances the stability conditions of the system. The simulation results verify the reliability of the new torque control strategy.
Abstract: The study assessed the potential and economic viability of stand-alone wind systems for embedded generation, taking into account its benefits to small off-grid rural communities at 40 meteorological sites in Nigeria. A specific electric load profile was developed to accommodate communities consisting of 200 homes, a school and a community health centre. This load profile was incorporated within the distributed generation analysis producing energy in the MW range, while optimally meeting daily load demand for the rural communities. Twenty-four years (1987 to 2010) of wind speed data at a height of 10m utilized for the study were sourced from the Nigeria Meteorological Department, Oshodi. The HOMER® software optimizing tool was engaged for the feasibility study and design. Each site was suited to 3MW wind turbines in sets of five, thus 15MW was designed for each site. This design configuration was adopted in order to easily compare the distributed generation system amongst the sites to determine their relative economic viability in terms of life cycle cost, as well as levelised cost of producing energy. A net present value was estimated in terms of life cycle cost for 25 of the 40 meteorological sites. On the other hand, the remaining sites yielded a net present cost; meaning the installations at these locations were not economically viable when utilizing the present tariff regime for embedded generation in Nigeria.
Abstract: There exist significant losses on transmission lines due to distance, as power generating stations could be located far from some isolated settlements. Standalone wind farms could be a good choice of alternative power generation for such settlements that are far from the grid due to factors of long distance or socio-economic problems. However, uncompensated wind farms consume reactive power since wind turbines are induction generators. Therefore, capacitor banks are used to compensate reactive power, which in turn improves the voltage profile of the network. Although capacitor banks help improving voltage profile, they also undergo switching actions due to its compensating response to the variation of various types of load at the consumer’s end. These switching activities could cause transient overvoltage on the network, jeopardizing the end-life of other equipment on the system. In this paper, the overvoltage caused by these switching activities is investigated using the IEEE bus 14-network to represent a standalone wind farm, and the simulation is done using ATP/EMTP software. Scenarios involving the use of pre-insertion resistor and pre-insertion inductor, as well as controlled switching was also carried out in order to decide the best mitigation option to reduce the overvoltage.
Abstract: Due to the randomness and uncertainty of wind energy, modern power systems integrating large-scale wind generation will be significantly impacted in terms of system performance and technical challenges. System inertia with high wind penetration is decreasing when conventional thermal generators are gradually replaced by wind turbines, which do not naturally contribute to inertia response. The power imbalance caused by wind power or demand fluctuations leads to the instability of system frequency. Accordingly, the need to attach the supplementary virtual inertia control to wind farms (WFs) strongly arises. When multi-wind farms are connected to the grid simultaneously, the selection of which critical WFs to install the virtual inertia control is greatly important to enhance the stability of system frequency. By building the small signal model of wind power systems considering frequency regulation, the installation locations are identified by the geometric measures of the mode observability of WFs. In addition, this paper takes the impacts of grid topology and selection of feedback control signals into consideration. Finally, simulations are conducted on a multi-wind farms power system and the results demonstrate that the designed virtual inertia control method can effectively assist the frequency regulation.
Abstract: This paper presents the data of a series of two-dimensional Discrete Element Method (DEM) simulations of a large-diameter rigid monopile subjected to cyclic loading under a high gravitational force. At present, monopile foundations are widely used to support the tall and heavy wind turbines, which are also subjected to significant from wind and wave actions. A safe design must address issues such as rotations and changes in soil stiffness subject to these loadings conditions. Design guidance on the issue is limited, so are the availability of laboratory and field test data. The interpretation of these results in sand, such as the relation between loading and displacement, relies mainly on empirical correlations to pile properties. Regarding numerical models, most data from Finite Element Method (FEM) can be found. They are not comprehensive, and most of the FEM results are sensitive to input parameters. The micro scale behaviour could change the mechanism of the soil-structure interaction. A DEM model was used in this paper to study the cyclic lateral loads behaviour. A non-dimensional framework is presented and applied to interpret the simulation results. The DEM data compares well with various set of published experimental centrifuge model test data in terms of lateral deflection. The accumulated permanent pile lateral displacements induced by the cyclic lateral loads were found to be dependent on the characteristics of the applied cyclic load, such as the extent of the loading magnitudes and directions.
Abstract: The article proposes maximum power point tracking without mechanical sensor using Multilayer Perceptron Neural Network (MLPNN). The aim of article is to reduce the cost and complexity but still retain efficiency. The experimental is that duty cycle is generated maximum power, if it has suitable qualification. The measured data from DC generator, voltage (V), current (I), power (P), turnover rate of power (dP), and turnover rate of voltage (dV) are used as input for MLPNN model. The output of this model is duty cycle for driving the converter. The experiment implemented using Arduino Uno board. This diagram is compared to MPPT using MLPNN and P&O control (Perturbation and Observation control). The experimental results show that the proposed MLPNN based approach is more efficiency than P&O algorithm for this application.
Abstract: This paper details the progress made in the development of the different state-of-the-art aerodynamic tools for the analysis of vertical axis wind turbines including the flow simulation around the blade, viscous flow, stochastic wind, and dynamic stall effects. The paper highlights the capabilities of the developed wind turbine aerodynamic codes over the last thirty years which are currently being used in North America and Europe by Sandia Laboratories, FloWind, IMST Marseilles, and Hydro-Quebec among others. The aerodynamic codes developed at Ecole Polytechnique de Montreal, Canada, represent valuable tools for simulating the flow around wind turbines including secondary effects. Comparison of theoretical results with experimental data have shown good agreement. The strength of the aerodynamic codes based on Double-Multiple Stream tube model (DMS) lies in its simplicity, accuracy, and ability to analyze secondary effects that interfere with wind turbine aerodynamic calculations.
Abstract: The cumulative costs for O&M may represent as
much as 65%-90% of the turbine's investment cost. Nowadays the
cost effectiveness concept becomes a decision-making and
technology evaluation metric. The cost of energy metric accounts for
the effect replacement cost and unscheduled maintenance cost
parameters. One key of the proposed approach is the idea of
maintaining the WTs which can be captured via use of a finite state
Markov chain. Such a model can be embedded within a probabilistic
operation and maintenance simulation reflecting the action to be
done. In this paper, an approach of estimating the cost of O&M is
presented. The finite state Markov model is used for decision
problems with number of determined periods (life cycle) to predict
the cost according to various options of maintenance.
Abstract: With 40% of total world energy consumption,
building systems are developing into technically complex large
energy consumers suitable for application of sophisticated power
management approaches to largely increase the energy efficiency
and even make them active energy market participants. Centralized
control system of building heating and cooling managed by
economically-optimal model predictive control shows promising
results with estimated 30% of energy efficiency increase. The research
is focused on implementation of such a method on a case study
performed on two floors of our faculty building with corresponding
sensors wireless data acquisition, remote heating/cooling units and
central climate controller. Building walls are mathematically modeled
with corresponding material types, surface shapes and sizes. Models
are then exploited to predict thermal characteristics and changes in
different building zones. Exterior influences such as environmental
conditions and weather forecast, people behavior and comfort
demands are all taken into account for deriving price-optimal climate
control. Finally, a DC microgrid with photovoltaics, wind turbine,
supercapacitor, batteries and fuel cell stacks is added to make the
building a unit capable of active participation in a price-varying
energy market. Computational burden of applying model predictive
control on such a complex system is relaxed through a hierarchical
decomposition of the microgrid and climate control, where the
former is designed as higher hierarchical level with pre-calculated
price-optimal power flows control, and latter is designed as lower
level control responsible to ensure thermal comfort and exploit
the optimal supply conditions enabled by microgrid energy flows
management. Such an approach is expected to enable the inclusion
of more complex building subsystems into consideration in order to
further increase the energy efficiency.
Abstract: This paper presents the performance characteristics of
Darrieus-type vertical axis wind turbine (VAWT) with NACA airfoil
blades. The performance of Darrieus-type VAWT can be
characterized by torque and power. There are various parameters
affecting the performance such as chord length, helical angle, pitch
angle and rotor diameter. To estimate the optimum shape of Darrieustype
wind turbine in accordance with various design parameters, we
examined aerodynamic characteristics and separated flow occurring
in the vicinity of blade, interaction between flow and blade, and
torque and power characteristics derived from it. For flow analysis,
flow variations were investigated based on the unsteady RANS
(Reynolds-averaged Navier-Stokes) equation. Sliding mesh algorithm
was employed in order to consider rotational effect of blade. To
obtain more realistic results we conducted experiment and numerical
analysis at the same time for three-dimensional shape. In addition,
several parameters (chord length, rotor diameter, pitch angle, and
helical angle) were considered to find out optimum shape design and
characteristics of interaction with ambient flow. Since the NACA
airfoil used in this study showed significant changes in magnitude of
lift and drag depending on an angle of attack, the rotor with low drag,
long cord length and short diameter shows high power coefficient in
low tip speed ratio (TSR) range. On the contrary, in high TSR range,
drag becomes high. Hence, the short-chord and long-diameter rotor
produces high power coefficient. When a pitch angle at which airfoil
directs toward inside equals to -2° and helical angle equals to 0°,
Darrieus-type VAWT generates maximum power.
Abstract: Large-scale machine tools for the manufacturing of
large work pieces, e.g. blades, casings or gears for wind turbines,
feature pose-dependent dynamic behavior. Small structural damping
coefficients lead to long decay times for structural vibrations that
have negative impacts on the production process. Typically, these
vibrations are handled by increasing the stiffness of the structure by
adding mass. This is counterproductive to the needs of sustainable
manufacturing as it leads to higher resource consumption both in
material and in energy. Recent research activities have led to higher
resource efficiency by radical mass reduction that is based on controlintegrated
active vibration avoidance and damping methods. These
control methods depend on information describing the dynamic
behavior of the controlled machine tools in order to tune the
avoidance or reduction method parameters according to the current
state of the machine. This paper presents the appearance, consequences and challenges
of the pose-dependent dynamic behavior of lightweight large-scale
machine tool structures in production. It starts with the theoretical
introduction of the challenges of lightweight machine tool structures
resulting from reduced stiffness. The statement of the pose-dependent
dynamic behavior is corroborated by the results of the experimental
modal analysis of a lightweight test structure. Afterwards, the
consequences of the pose-dependent dynamic behavior of lightweight
machine tool structures for the use of active control and vibration
reduction methods are explained. Based on the state of the art of
pose-dependent dynamic machine tool models and the modal
investigation of an FE-model of the lightweight test structure, the
criteria for a pose-dependent model for use in vibration reduction are
derived. The description of the approach for a general posedependent
model of the dynamic behavior of large lightweight
machine tools that provides the necessary input to the aforementioned
vibration avoidance and reduction methods to properly tackle
machine vibrations is the outlook of the paper.
Abstract: A novel Active Flap System (AFS) has been developed
at DTU Wind Energy, as a result of a 3-year R&D project following
almost 10 years of innovative research in this field. The full scale AFS
comprises an active deformable trailing edge has been tested at the
unique rotating test facility at the Risø Campus of DTU Wind Energy
in Denmark. The design and instrumentation of the wing section and
the AFS are described. The general description and objectives of the
rotating test rig at the Risø campus of DTU are presented, along
with an overview of sensors on the setup and the test cases. The
post-processing of data is discussed and results of steady, flap step
and azimuth control flap cases are presented.
Abstract: This paper investigates the thermal issue of permanent
magnet synchronous generator which is frequently used in direct
drive gearless small-scale wind turbine applications. Permanent
Magnet Synchronous Generator (PMSG) is designed with 2.5 kW
continuous and 6 kW peak power. Then considering generator
geometry, mechanical design of wind turbine is performed. Thermal
analysis and optimization is carried out considering all wind turbine
components to reach realistic results. This issue is extremely
important in research and development (R&D) process for wind
turbine applications.
Abstract: As per the statistical data, the Doubly-fed Induction
Generator (DFIG) based wind turbine with variable speed and
variable pitch control is the most common wind turbine in the
growing wind market. This machine is usually used on the grid
connected wind energy conversion system to satisfy grid code
requirements such as grid stability, Fault Ride Through (FRT), power
quality improvement, grid synchronization and power control etc.
Though the requirements are not fulfilled directly by the machine, the
control strategy is used in both the stator as well as rotor side along
with power electronic converters to fulfil the requirements stated
above. To satisfy the grid code requirements of wind turbine, usually
grid side converter is playing a major role. So in order to improve the
operation capacity of wind turbine under critical situation, the
intensive study of both machine side converter control and grid side
converter control is necessary In this paper DFIG is modeled using
power components as variables and the performance of the DFIG
system is analysed under grid voltage fluctuations. The voltage
fluctuations are made by lowering and raising the voltage values in
the utility grid intentionally for the purpose of simulation keeping in
view of different grid disturbances.
Abstract: In this paper, to model a real life wind turbine, a
probabilistic approach is proposed to model the dynamics of the
blade elements of a small axial wind turbine under extreme stochastic
wind speeds conditions. It was found that the power and the torque
probability density functions even-dough decreases at these extreme
wind speeds but are not infinite. Moreover, we also fund that it
is possible to stabilize the power coefficient (stabilizing the output
power)above rated wind speeds by turning some control parameters.
This method helps to explain the effect of turbulence on the quality
and quantity of the harness power and aerodynamic torque.
Abstract: The aim of our study is to project an optimized wind turbine of Darrieus type. This type of wind turbine is characterized by a low starting torque in comparison with the Savonius rotor allowing them to operate for a period greater than wind speed. This led us to reconsider the Darrieus rotor to optimize a design which will increase its starting torque. The study of a system of monitoring and control of the angle of attack of blade profile, which allows an auto start to wind speeds as low as possible is presented for the straight blade of Darrieus turbine. The study continues to extend to other configurations namely those of parabolic type.
Abstract: This paper presents a power control for a Doubly Fed
Induction Generator (DFIG) using in Wind Energy Conversion
System (WECS) connected to the grid. The proposed control strategy
employs two nonlinear controllers, Backstipping (BSC) and slidingmode
controller (SMC) scheme to directly calculate the required
rotor control voltage so as to eliminate the instantaneous errors of
active and reactive powers. In this paper the advantages of BSC and
SMC are presented, the performance and robustness of this two
controller’s strategy are compared between them. First, we present a
model of wind turbine and DFIG machine, then a synthesis of the
controllers and their application in the DFIG power control.
Simulation results on a 1.5MW grid-connected DFIG system are
provided by MATLAB/Simulink.
Abstract: Nowadays, the use of renewable energy sources has been increasingly great because of the cost increase and public demand for clean energy sources. One of the fastest growing sources is wind energy. In this paper, Wind Diesel Hybrid System (WDHS) comprising a Diesel Generator (DG), a Wind Turbine Generator (WTG), the Consumer Load, a Battery-based Energy Storage System (BESS), and a Dump Load (DL) is used. Voltage is controlled by Diesel Generator; the frequency is controlled by BESS and DL. The BESS elimination is an efficient way to reduce maintenance cost and increase the dynamic response. Simulation results with graphs for the frequency of Power System, active power, and the battery power are presented for load changes. The controlling parameters are optimized by using Imperialist Competitive Algorithm (ICA). The simulation results for the BESS/no BESS cases are compared. Results show that in no BESS case, the frequency control is more optimal than the BESS case by using ICA.
Abstract: This paper reports the development and application of a 2D1 depth-averaged model. The main goal of this contribution is to apply the depth averaged equations to a wind park model in which the treatment of the geometry, introduced on the mathematical model by the mass and momentum source terms. The depth-averaged model will be used in future to find the optimal position of wind turbines in the wind park. κ − ε and 2D LES turbulence models were consider in this article. 2D CFD2 simulations for one hill was done to check the depth-averaged model in practise.
Abstract: The purpose of the paper is to estimate the US small
wind turbines market potential and forecast the small wind turbines
sales in the US. The forecasting method is based on the application of
the Bass model and the generalized Bass model of innovations
diffusion under replacement purchases. In the work an exponential
distribution is used for modeling of replacement purchases. Only one
parameter of such distribution is determined by average lifetime of
small wind turbines. The identification of the model parameters is
based on nonlinear regression analysis on the basis of the annual
sales statistics which has been published by the American Wind
Energy Association (AWEA) since 2001 up to 2012. The estimation
of the US average market potential of small wind turbines (for
adoption purchases) without account of price changes is 57080
(confidence interval from 49294 to 64866 at P = 0.95) under average
lifetime of wind turbines 15 years, and 62402 (confidence interval
from 54154 to 70648 at P = 0.95) under average lifetime of wind
turbines 20 years. In the first case the explained variance is 90,7%,
while in the second - 91,8%. The effect of the wind turbines price
changes on their sales was estimated using generalized Bass model.
This required a price forecast. To do this, the polynomial regression
function, which is based on the Berkeley Lab statistics, was used. The
estimation of the US average market potential of small wind turbines
(for adoption purchases) in that case is 42542 (confidence interval
from 32863 to 52221 at P = 0.95) under average lifetime of wind
turbines 15 years, and 47426 (confidence interval from 36092 to
58760 at P = 0.95) under average lifetime of wind turbines 20 years.
In the first case the explained variance is 95,3%, while in the second
– 95,3%.