Abstract: As per the statistical data, the Doubly-fed Induction
Generator (DFIG) based wind turbine with variable speed and
variable pitch control is the most common wind turbine in the
growing wind market. This machine is usually used on the grid
connected wind energy conversion system to satisfy grid code
requirements such as grid stability, Fault Ride Through (FRT), power
quality improvement, grid synchronization and power control etc.
Though the requirements are not fulfilled directly by the machine, the
control strategy is used in both the stator as well as rotor side along
with power electronic converters to fulfil the requirements stated
above. To satisfy the grid code requirements of wind turbine, usually
grid side converter is playing a major role. So in order to improve the
operation capacity of wind turbine under critical situation, the
intensive study of both machine side converter control and grid side
converter control is necessary In this paper DFIG is modeled using
power components as variables and the performance of the DFIG
system is analysed under grid voltage fluctuations. The voltage
fluctuations are made by lowering and raising the voltage values in
the utility grid intentionally for the purpose of simulation keeping in
view of different grid disturbances.
Abstract: Nowadays, the use of renewable energy sources has been increasingly great because of the cost increase and public demand for clean energy sources. One of the fastest growing sources is wind energy. In this paper, Wind Diesel Hybrid System (WDHS) comprising a Diesel Generator (DG), a Wind Turbine Generator (WTG), the Consumer Load, a Battery-based Energy Storage System (BESS), and a Dump Load (DL) is used. Voltage is controlled by Diesel Generator; the frequency is controlled by BESS and DL. The BESS elimination is an efficient way to reduce maintenance cost and increase the dynamic response. Simulation results with graphs for the frequency of Power System, active power, and the battery power are presented for load changes. The controlling parameters are optimized by using Imperialist Competitive Algorithm (ICA). The simulation results for the BESS/no BESS cases are compared. Results show that in no BESS case, the frequency control is more optimal than the BESS case by using ICA.
Abstract: In this paper presents a technique for developing the
computational efficiency in simulating double output induction
generators (DOIG) with two rotor circuits where stator transients are
to be included. Iterative decomposition is used to separate the flux–
Linkage equations into decoupled fast and slow subsystems, after
which the model order of the fast subsystems is reduced by
neglecting the heavily damped fast transients caused by the second
rotor circuit using integral manifolds theory. The two decoupled
subsystems along with the equation for the very slowly changing slip
constitute a three time-scale model for the machine which resulted in
increasing computational speed. Finally, the proposed method of
reduced order in this paper is compared with the other conventional
methods in linear and nonlinear modes and it is shown that this
method is better than the other methods regarding simulation
accuracy and speed.
Abstract: In a wind power generator using doubly fed induction
generator (DFIG), the three-phase pulse width modulation (PWM)
voltage source converter (VSC) is used as grid side converter (GSC)
and rotor side converter (RSC). The standard linear control laws
proposed for GSC provides not only instablity against comparatively
large-signal disturbances, but also the problem of stability due to
uncertainty of load and variations in parameters. In this paper, a
nonlinear controller is designed for grid side converter (GSC) of a
DFIG for wind power application. The nonlinear controller is
designed based on the input-output feedback linearization control
method. The resulting closed-loop system ensures a sufficient
stability region, make robust to variations in circuit parameters and
also exhibits good transient response. Computer simulations and
experimental results are presented to confirm the effectiveness of the
proposed control strategy.
Abstract: Wind turbines with double output induction
generators can operate at variable speed permitting conversion
efficiency maximization over a wide range of wind velocities. This
paper presents the performance analysis of a wind driven double
output induction generator (DOIG) operating at varying shafts speed.
A periodic transient state analysis of DOIG equipped with two
converters is carried out using a hybrid induction machine model.
This paper simulates the harmonic content of waveforms in various
points of drive at different speeds, based on the hybrid model
(dqabc). Then the sinusoidal and trapezoidal pulse-width–modulation
control techniques are used in order to improve the power factor of
the machine and to weaken the injected low order harmonics to the
supply. Based on the frequency spectrum, total harmonics distortion,
distortion factor and power factor. Finally advantages of sinusoidal
and trapezoidal pulse width modulation techniques are compared.