Abstract: A camera in the building site is exposed to different
weather conditions. Differences between images of the same scene
captured with the same camera arise also due to temperature variations.
The influence of temperature changes on camera parameters
were modelled and integrated into existing analytical camera model.
Modified camera model enables quantitatively assessing the influence
of temperature variations.
Abstract: The camera parameters are changed due to temperature
variations, which directly influence calibrated cameras accuracy.
Robustness of calibration methods were measured and their accuracy
was tested. An error ratio due to camera parameters change
with respect to total error originated during calibration process was
determined. It pointed out that influence of temperature variations
decrease by increasing distance of observed objects from cameras.
Abstract: This paper present some preliminary work on the
preparation and physicochemical caracterization of nanocomposite
MFI-alumina structures based on alumina hollow fibres. The fibers
are manufactured by a wet spinning process. α-alumina particles were
dispersed in a solution of polysulfone in NMP. The resulting slurry is
pressed through the annular gap of a spinneret into a precipitation
bath. The resulting green fibres are sintered. The mechanical strength
of the alumina hollow fibres is determined by a three-point-bending
test while the pore size is characterized by bubble-point testing. The
bending strength is in the range of 110 MPa while the average pore
size is 450 nm for an internal diameter of 1 mm and external diameter
of 1.7 mm. To characterize the MFI membranes various techniques
were used for physicochemical characterization of MFI–ceramic
hollow fibres membranes: The nitrogen adsorption, X-ray
diffractometry, scanning electron microscopy combined with X
emission microanalysis. Scanning Electron Microscopy (SEM) and
Energy Dispersive Microanalysis by the X-ray were used to observe
the morphology of the hollow fibre membranes (thickness,
infiltration into the carrier, defects, homogeneity). No surface film,
has been obtained, as observed by SEM and EDX analysis and
confirmed by high temperature variation of N2 and CO2 gas
permeances before cation exchange. Local analysis and characterise
(SEM and EDX) and overall (by ICP elemental analysis) were
conducted on two samples exchanged to determine the quantity and
distribution of the cation of cesium on the cross section fibre of the
zeolite between the cavities.
Abstract: In this paper, an ultra low power and low jitter 12bit
CMOS digitally controlled oscillator (DCO) design is presented.
Based on a ring oscillator implemented with low power Schmitt
trigger based inverters. Simulation of the proposed DCO using 32nm
CMOS Predictive Transistor Model (PTM) achieves controllable
frequency range of 550MHz~830MHz with a wide linearity and high
resolution. Monte Carlo simulation demonstrates that the time-period
jitter due to random power supply fluctuation is under 31ps and the
power consumption is 0.5677mW at 750MHz with 1.2V power
supply and 0.53-ps resolution. The proposed DCO has a good
robustness to voltage and temperature variations and better linearity
comparing to the conventional design.
Abstract: An adaptive Helmholtz resonator was designed and
adapted to hydraulics. The resonator was controlled by open- and
closed-loop controls so that 20 dB attenuation of the peak-to-peak
value of the pulsating pressure was maintained. The closed-loop
control was noted to be better, albeit it was slower because of its low
pressure and temperature variation, which caused variation in the
effective bulk modulus of the hydraulic system. Low-pressure
hydraulics contains air, which affects the stiffness of the hydraulics,
and temperature variation changes the viscosity of the oil. Thus, an
open-loop control loses its efficiency if a condition such as
temperature or the amount of air changes after calibration. The
instability of the low-pressure hydraulic system reduced the
operational frequency range of the Helmholtz resonator when
compared with the results of an analytical model.
Different dampers for hydraulics are presented. Then analytical
models of a hydraulic pipe and a hydraulic pipe with a Helmholtz
resonator are presented. The analytical models are based on the wave
equation of sound pressure. Finally, control methods and the results
of experiments are presented.
Abstract: Ultra-low-power (ULP) circuits have received
widespread attention due to the rapid growth of biomedical
applications and Battery-less Electronics. Subthreshold region of
transistor operation is used in ULP circuits. Major research challenge
in the subthreshold operating region is to extract the ULP benefits
with minimal degradation in speed and robustness. Process, Voltage
and Temperature (PVT) variations significantly affect the
performance of subthreshold circuits. Designed performance
parameters of ULP circuits may vary largely due to temperature
variations. Hence, this paper investigates the effect of temperature
variation on device and circuit performance parameters at different
biasing voltages in the subthreshold region. Simulation results clearly
demonstrate that in deep subthreshold and near threshold voltage
regions, performance parameters are significantly affected whereas in
moderate subthreshold region, subthreshold circuits are more
immune to temperature variations. This establishes that moderate
subthreshold region is ideal for temperature immune circuits.
Abstract: This paper describes a novel monitoring scheme to
minimize total active power in digital circuits depend on the demand
frequency, by adjusting automatically both supply voltage and
threshold voltages based on circuit operating conditions such as
temperature, process variations, and desirable frequency. The delay
monitoring results, will be control and apply so as to be maintained at
the minimum value at which the chip is able to operate for a given
clock frequency. Design details of power monitor are examined using
simulation framework in 32nm BTPM model CMOS process.
Experimental results show the overhead of proposed circuit in terms
of its power consumption is about 40 μW for 32nm technology;
moreover the results show that our proposed circuit design is not far
sensitive to the temperature variations and also process variations.
Besides, uses the simple blocks which offer good sensitivity, high
speed, the continuously feedback loop. This design provides up to
40% reduction in power consumption in active mode.
Abstract: Thermal load calculations have been performed for
multi-layered walls that are composed of three different parts; a
common (sand and cement) plaster, and two types of locally
produced soft and hard bricks. The masonry construction of these
layered walls was based on concrete-backed stone masonry made of
limestone bricks joined by mortar. These multilayered walls are
forming the outer walls of the building envelope of a typical Libyan
house. Based on the periodic seasonal weather conditions, within the
Libyan cost region during summer and winter, measured thermal
conductivity values were used to implement such seasonal variation
of heat flow and the temperature variations through the walls. The
experimental measured thermal conductivity values were obtained
using the Hot Disk technique. The estimation of the thermal
resistance of the wall layers ( R-values) is based on measurements
and calculations. The numerical calculations were done using a
simplified analytical model that considers two different wall
constructions which are characteristics of such houses. According to
the obtained results, the R-values were quite low and therefore,
several suggestions have been proposed to improve the thermal
loading performance that will lead to a reasonable human comfort
and reduce energy consumption.
Abstract: This paper is a continuation of our interest in the influence of temperature on specific retention volumes and the resulting infinite dilution activity coefficients. This has a direct effect in the design of absorption and stripping columns for the abatement of volatile organic compounds. The interaction of 13 volatile organic compounds (VOCs) with polydimethylsiloxane (PDMS) at varying temperatures was studied by gas liquid chromatography (GLC). Infinite dilution activity coefficients and specific retention volumes obtained in this study were found to be in agreement with those obtained from static headspace and group contribution methods by the authors as well as literature values for similar systems. Temperature variation also allows for transport calculations for different seasons. The results of this work confirm that PDMS is well suited for the scrubbing of VOCs from waste gas streams. Plots of specific retention volumes against temperature gave linear van-t Hoff plots.
Abstract: This paper presents positive and negative full-wave
rectifier. The proposed structure is based on OTA using
commercially available ICs (LT1228). The features of the proposed
circuit are that: it can rectify and amplify voltage signal with
controllable output magnitude via input bias current: the output
voltage is free from temperature variation. The circuit description
merely consists of 1 single ended and 3 fully differential OTAs. The
performance of the proposed circuit are investigated though PSpice.
They show that the proposed circuit can function as positive/negative
full-wave rectifier, where the voltage input wide-dynamic range from
-5V to 5V. Furthermore, the output voltage is slightly dependent on
the temperature variations.