Abstract: Banana is one of the most consumed fruits in the tropics and subtropics. Brazil accounts for about 9% of the world banana production. However, the production losses are as high as 30 to 40% and even much higher in some developing countries. The green banana flour is a complex carbohydrate source, including a high total starch (73.4%), resistant starch (17.5%) with functional properties. Gamma irradiation is considered to be an alternative method for food preservation. It has been performed due to the need of extending the shelf - life of foods, whilst maintaining their safety and avoiding one of the main concerns: the nutrient loss. In this work data about on the effects of ionizing radiation on the physicochemical analysis (carbohydrate, proteins, lipids, alimentary fiber, moistures and ashes) of Brazilian functional products (biscuits and bread) of the green banana pulp are presented. The caloric value was calculated. No significant difference was observed between the samples of irradiated and non – irradiated green banana biscuits with the following determinations: carbohydrates, proteins, alimentary fiber and ashes. Only a small significant difference was found in lipids (macronutrients). The results of physical chemical analysis of the irradiated and non- irradiated green banana bread non- irradiated showed no significant difference with the following determinations: carbohydrates, lipids (macronutrients), moisture, ashes and caloric value. A small difference was found in proteins (macronutrients). Irradiation of functional products (biscuits and bread) with doses of 1 and 3kGy maintained their original macronutrients content, showing good radioresistance.
Abstract: The ionizing radiation of livestock wastewater for the
removal of nitrogen and phosphorus was studied in the presence of a
natural zeolite. The feasibility of a combined process of zeolite ion
exchange and electron beam irradiation of livestock wastewater was
also investigated. The removal efficiencies of NH4
+-N, T-N and T-P
were significantly enhanced by electron beam irradiation after zeolite
ion exchange as a pre-treatment. The presence of silica zeolite
accelerated the decomposition rate of livestock wastewater in the
electron beam irradiation process. These results indicate that the
combined process of zeolite ion exchange and electron beam
irradiation has the potential for the treatment of livestock wastewater
Abstract: We developed an effective microfluidic device for photoreactions with low reflectance and good heat conductance. The performance of this microfluidic device was tested by carrying out a photoreactive synthesis of benzopinacol and acetone from benzophenone and 2-propanol. The yield reached 36% with an irradiation time of 469.2 s and was improved by more than 30% when compared to the values obtained by the batch method. Therefore, the microfluidic device was found to be effective for improving the yields of photoreactions.
Abstract: This paper describes the design of a voltage based maximum power point tracker (MPPT) for photovoltaic (PV) applications. Of the various MPPT methods, the voltage based method is considered to be the simplest and cost effective. The major disadvantage of this method is that the PV array is disconnected from the load for the sampling of its open circuit voltage, which inevitably results in power loss. Another disadvantage, in case of rapid irradiance variation, is that if the duration between two successive samplings, called the sampling period, is too long there is a considerable loss. This is because the output voltage of the PV array follows the unchanged reference during one sampling period. Once a maximum power point (MPP) is tracked and a change in irradiation occurs between two successive samplings, then the new MPP is not tracked until the next sampling of the PV array voltage. This paper proposes an MPPT circuit in which the sampling interval of the PV array voltage, and the sampling period have been shortened. The sample and hold circuit has also been simplified. The proposed circuit does not utilize a microcontroller or a digital signal processor and is thus suitable for low cost and low power applications.
Abstract: Microwave heating process has been developed about sixty years while measurement system has also progressed. Because of irradiation of high frequency of microwave, researchers have been utilized many costly technical instrument measuring parameters to evaluate the performance of microwave heating system. Therefore, this paper is intended to present an easier and feasible efficiency measurement method. It can help inspecting efficiency of microwave heating system with good accuracy, while the method can also give reference to optimizing procedure for microwave heating system for various load material
Abstract: A study concerning the photocatalytic decolourization
of Congo red (CR) dye, over artificial UV irradiation is presented.
Photocatalysts based on a commercial titanium dioxide (TiO2)
modified with transition metals (Ni, Cu and Zn) were used. The
dopage method used was wet impregnation. A TiO2 sample without
salt was subjected to the same hydrothermal treatment to be used as
reference. Congo red solutions to several pH conditions (natural and
basic) were used to evaluate photocatalytic performance of each
doped catalysts. Photodecolourization percentage was measured
spectrofotrometically after 3 h of treatment to 499 nm as response
variable. Kinetics investigations of photodegradation indicated that
reactions obey to Langmuir-Hinshelwood model and pseudo–first
order law. The rate constant studies of photocatalytic decolourization
reactions for Zn–TiO2 and Cu–TiO2 photocatalysts indicated that in
all cases the rate constant of the reaction was higher than that of TiO2
undoped. These results show that nature of the metal modifying the
TiO2 influence on the efficiency of the photocatalyst evaluated in
process. Ni does not present an additional effect compared with TiO2,
while Zn enhances the photoactivity due to its electronic properties.
Abstract: The Brazilian legislation has only established
diagnostic reference levels (DRLs) in terms of Multiple Scan
Average Dose (MSAD) as a quality control parameter for computed
tomography (CT) scanners. Compliance with DRLs can be verified
by measuring the Computed Tomography Kerma Index (Ca,100) with
a pencil ionization chamber or by obtaining the kerma distribution in
CT scans with radiochromic films or rod shape lithium fluoride
termoluminescent dosimeters (TLD-100). TL dosimeters were used
to record kerma profiles and to determine MSAD values of a Bright
Speed model GE CT scanner. Measurements were done with
radiochromic films and TL dosimeters distributed in cylinders
positioned in the center and in four peripheral bores of a standard
polymethylmethacrylate (PMMA) body CT dosimetry phantom.
Irradiations were done using a protocol for adult chest. The
maximum values were found at the midpoint of the longitudinal axis.
The MSAD values obtained with three dosimetric techniques were
compared.
Abstract: This work contains information about the influence low-level optical irradiation on sperm motility of sturgeon fish. On the basis of given and earlier received data the following conclusion has been made. Among the photophysical processes of a resonant and not resonant nature (oriented action of light; action of gradient forces; dipole-dipole interaction; termooptical processes), which are capable to cause the photobiological effects depended on such laserspecific characteristics as polarization and coherency, determining influence belongs to oriented action of light and dipole-dipole interactions among the processes studied in the present work.
Abstract: Raman spectroscopy are used to characterize the
chemical changes in normoxic polyhydroxyethylacrylate gel
dosimeter (PHEA) induced by radiation. Irradiations in the low dose
region are performed and the polymerizations of PHEA gels are
monitored by the observing the changes of Raman shift intensity of
the carbon covalent bond of PHEA originated from both monomer
and the cross-linker. The variation in peak intensities with absorbed
dose was observed. As the dose increase, the peak intensities of
covalent bond of carbon in the polymer gels decrease. This point out
that the amount of absorbed dose affect the polymerization of
polymer gels. As the absorbed dose increase, the polymerizations
also increase. Results verify that PHEA gel dosimeters are sensitive
even in lower dose region.
Abstract: This study shows the effect of carbon towards
molybdenum carbide alloy when exposed to Microwave. This
technique is also known as Microwave Induced Alloying (MIA) for
the preparation of molybdenum carbide. In this study ammonium
heptamolybdate solution and carbon black powder were
heterogeneously mixed and exposed to microwave irradiation for 2
minutes. The effect on amount of carbon towards the produced alloy
on morphological and oxidation states changes during microwave is
presented. In this experiment, it is expected carbon act as a reducing
agent with the ratio 2:7 molybdenum to carbon as the optimum for
the production of molybdenum carbide alloy. All the morphological
transformations and changes in this experiment were followed and
characterized using X-Ray Diffraction and FESEM.
Abstract: Controlled modification of appropriate sharpness for
nanotips is of paramount importance to develop novel materials and
functional devices at a nanometer resolution. Herein, we present a
reliable and unique strategy of laser irradiation enhanced
physicochemical etching to manufacture super sharp tungsten tips
with reproducible shape and dimension as well as high yields
(~80%). The corresponding morphology structure evolution of
tungsten tips and laser-tip interaction mechanisms were
systematically investigated and discussed using field emission
scanning electron microscope (SEM) and physical optics statistics
method with different fluences under 532 nm laser irradiation. This
work paves the way for exploring more accessible metallic tips
applications with tunable apex diameter and aspect ratio, and,
furthermore, facilitates the potential sharpening enhancement
technique for other materials used in a variety of nanoscale devices.
Abstract: White scar oyster (Crassostrea belcheri) is often eaten
raw and being the leading vehicle for foodborne disease, especially
Salmonella Weltevreden which exposed the prominent and most
resistant to radiation. Gamma irradiation at a low dose of 1 kGy was
enough to eliminate S. Weltevreden contaminated in oyster meat at a
level up to 5 log CFU/g while it still retain the raw characteristics and
equivalent sensory quality as the non-irradiated one. Process
development of ready-to-eat chilled oyster meat was conducted by
shucking the meat, individually packed in plastic bags, subjected to 1
kGy gamma radiation at chilled condition and then stored in 4oC
refrigerated temperature. Microbiological determination showed the
absence of S. Weltevreden (5 log CFU/g initial inoculated) along the
whole storage time of 30 days. Sensory evaluation indicated the
decreasing in sensory scores along storage time which determining
the product shelf life to be 18 days compared to 15 days of nonirradiated
one. The most advantage of developed process was to
provide the safe raw oyster to consumers and in addition sensory
quality retained and 3-day extension shelf life also exist.
Abstract: This paper presents the results of the preliminary investigation of microwave (MW) irradiation pretreatments on the anaerobic digestion of food residues using biochemical methane potential (BMP) assays. Low solids systems with a total solids (TS) content ranging from 5.0-10.0% were analyzed. The inoculum to bulk mass of substrates to water ratio was 1:2:2 (mass basis). The experimental conditions for pretreatments were as follows: a control (no MW irradiation), two runs with MW irradiation for 15 and 30 minutes at 320 W, and another two runs with MW irradiation at 528 W for 30 and 60 minutes. The cumulative biogas production were 6.3 L and 8.7 L for 15min/320 W and 30min/320 W MW irradiation conditions, respectively, and 10.5 L and 11.4 L biogas for 30min/528 W and 60min/528 W, respectively, as compared to the control giving 5.8 L biogas. Both an increase in exposure time of irradiation and power of MW had increased the rate and yield of biogas. Singlefactor ANOVA tests (p
Abstract: An ultrasound-assisted activation method for
electroless silver plating is presented in this study. When the
ultrasound was applied during the activation step, the amount of the Pd
species adsorbed on substrate surfaces was higher than that of sample
pretreated with a conventional activation process without ultrasound
irradiation. With this activation method, it was also shown that the
adsorbed Pd species with a size of about 5 nm were uniformly
distributed on the surfaces, thus a smooth and uniform coating on the
surfaces was obtained by subsequent electroless silver plating. The
samples after each step were characterized by AFM, XPS, FIB, and
SEM.
Abstract: This paper presents modeling and simulation of Grid Connected Photovoltaic (PV) system by using improved mathematical model. The model is used to study different parameter variations and effects on the PV array including operating temperature and solar irradiation level. In this paper stepped P&O algorithm is proposed for MPPT control. This algorithm will identify the suitable duty ratio in which the DC-DC converter should be operated to maximize the power output. Photo voltaic array with proposed stepped P&O-MPPT controller can operate in the maximum power point for the whole range of solar data (irradiance and temperature).
Abstract: In this paper a new maximum power point tracking
algorithm for photovoltaic arrays is proposed. The algorithm detects
the maximum power point of the PV. The computed maximum
power is used as a reference value (set point) of the control system.
ON/OFF power controller with hysteresis band is used to control the
operation of a Buck chopper such that the PV module always
operates at its maximum power computed from the MPPT algorithm.
The major difference between the proposed algorithm and other
techniques is that the proposed algorithm is used to control directly
the power drawn from the PV.
The proposed MPPT has several advantages: simplicity, high
convergence speed, and independent on PV array characteristics. The
algorithm is tested under various operating conditions. The obtained
results have proven that the MPP is tracked even under sudden
change of irradiation level.
Abstract: The thermal, epithermal and fast fluxes were
calculated for three irradiation channels at Egypt Second Research
Reactor (ETRR-2) using CITVAP code. The validity of the
calculations was verified by experimental measurements. There are
some deviations between measurements and calculations. This is due
to approximations in the calculation models used, homogenization of
regions, condensation of energy groups and uncertainty in nuclear
data used. Neutron flux data for the three irradiation channels are
now available. This would enable predicting the irradiation
conditions needed for future radioisotope production.
Abstract: The process of laser absorption in the skin during
laser irradiation was a critical point in medical application
treatments. Delivery the correct amount of laser light is a critical
element in photodynamic therapy (PDT). More amounts of laser
light able to affect tissues in the skin and small amount not able to
enhance PDT procedure in skin. The knowledge of the skin tone
laser dependent distribution of 635 nm radiation and its penetration
depth in skin is a very important precondition for the investigation of
advantage laser induced effect in (PDT) in epidermis diseases
(psoriasis). The aim of this work was to estimate an optimum effect
of diode laser (635 nm) on the treatment of epidermis diseases in
different color skin. Furthermore, it is to improve safety of laser in
PDT in epidermis diseases treatment. Advanced system analytical
program (ASAP) which is a new approach in investigating the PDT,
dependent on optical properties of different skin color was used in
present work. A two layered Realistic Skin Model (RSM); stratum
corneum and epidermal with red laser (635 nm, 10 mW) were used
for irradiative transfer to study fluence and absorbance in different
penetration for various human skin colors. Several skin tones very
fair, fair, light, medium and dark are used to irradiative transfer. This
investigation involved the principles of laser tissue interaction when
the skin optically injected by a red laser diode. The results
demonstrated that the power characteristic of a laser diode (635 nm)
can affect the treatment of epidermal disease in various color skins.
Power absorption of the various human skins were recorded and
analyzed in order to find the influence of the melanin in PDT
treatment in epidermal disease. A two layered RSM show that the
change in penetration depth in epidermal layer of the color skin has a
larger effect on the distribution of absorbed laser in the skin; this is
due to the variation of the melanin concentration for each color.
Abstract: Based on an analysis of the mechanism of degradation of optical characteristics of the ZnO-pigmented white paint by electron irradiation, a model of single molecular color centers is built. An equation that explains the relationship between the changes of variation of the ZnO-pigmented white paint-s spectrum absorptance and electron fluence is derived. The uncertain parameters in the equation can be calculated using the curve fitting by experimental data. The result indicates that the model can be applied to predict the degradation of optical characteristics of ZnO-pigmented white paint by electron radiation.
Abstract: Irradiated material is a typical example of a complex
system with nonlinear coupling between its elements. During
irradiation the radiation damage is developed and this development
has bifurcations and qualitatively different kinds of behavior.
The accumulation of primary defects in irradiated crystals is
considered in frame work of nonlinear evolution of complex system.
The thermo-concentration nonlinear feedback is carried out as a
mechanism of self-oscillation development.
It is shown that there are two ways of the defect density evolution
under stationary irradiation. The first is the accumulation of defects;
defect density monotonically grows and tends to its stationary state
for some system parameters. Another way that takes place for
opportune parameters is the development of self-oscillations of the
defect density.
The stationary state, its stability and type are found. The
bifurcation values of parameters (environment temperature, defect
generation rate, etc.) are obtained. The frequency of the selfoscillation
and the conditions of their development is found and
rated. It is shown that defect density, heat fluxes and temperature
during self-oscillations can reach much higher values than the
expected steady-state values. It can lead to a change of typical
operation and an accident, e.g. for nuclear equipment.