Abstract: Operating a device at high power and high frequency
is a major problem because wall losses greatly reduce the efficiency
of the device. In the present communication, authors analytically
analyzed the dependence of ohmic/RF efficiency, the fraction of
output power with respect to the total power generated, of gyrotron
cavity structure on the conductivity of copper for the second
harmonic TE0,6 mode. This study shows a rapid fall in the RF
efficiency as the quality (conductivity) of copper degrades. Starting
with an RF efficiency near 40% at the conductivity of ideal copper
(5.8 x 107 S/m), the RF efficiency decreases (upto 8%) as the copper
quality degrades. Assuming conductivity half that of ideal copper the
RF efficiency as a function of diffractive quality factor, Qdiff, has
been studied. Here the RF efficiency decreases rapidly with
increasing diffractive Q. Ohmic wall losses as a function of
frequency for 460 GHz gyrotron cavity excited in TE0,6 mode has
also been analyzed. For 460 GHz cavity, the extracted power is
reduced to 32% of the generated power due to ohmic losses in the
walls of the cavity.
Abstract: The development of the power electronics has allowed
increasing the precision and reliability of the electrical trainings,
thanks to the adjustable inverters, as the Pulse Wide Modulation
(PWM) five level inverters, which is the object of study in this
article.The authors treat the relation between the law order adopted for
a given system and the oscillations of the electrical and mechanical
parameters of which the tolerance depends on the process with which
they are integrated (paper factory, lifting of the heavy loads,
etc.).Thus the best choice of the regulation indexes allows us to
achieve stability and safety training without investment (management
of existing equipment).
Abstract: Water level forecasting using records of past time series is of importance in water resources engineering and management. For example, water level affects groundwater tables in low-lying coastal areas, as well as hydrological regimes of some coastal rivers. Then, a reliable prediction of sea-level variations is required in coastal engineering and hydrologic studies. During the past two decades, the approaches based on the Genetic Programming (GP) and Artificial Neural Networks (ANN) were developed. In the present study, the GP is used to forecast daily water level variations for a set of time intervals using observed water levels. The measurements from a single tide gauge at Urmia Lake, Northwest Iran, were used to train and validate the GP approach for the period from January 1997 to July 2008. Statistics, the root mean square error and correlation coefficient, are used to verify model by comparing with a corresponding outputs from Artificial Neural Network model. The results show that both these artificial intelligence methodologies are satisfactory and can be considered as alternatives to the conventional harmonic analysis.
Abstract: Power transformers are among the most important and
expensive equipments in the electric power systems. Consequently
the transformer protection is an essential part of the system
protection. This paper presents a new method for locating
transformer winding faults such as turn-to-turn, turn-to-core, turn-totransformer
body, turn-to-earth, and high voltage winding to low
voltage winding. In this study the current and voltage signals of input
and output terminals of the transformer are measured, which the
Fourier transform of measured signals and harmonic analysis
determine the fault's location.
Abstract: The paper presents a space-vector pulse width modulation (SVPWM) inverter feeding a permanent-magnet synchronous motor (PMSM). The SVPWM inverter enables to feed the motor with a higher voltage with low harmonic distortions than the conventional sinusoidal PWM inverter. The control strategy of the inverter is the voltage / frequency control method, which is based on the space-vector modulation technique. The proposed PMSM drive system involving the field-oriented control scheme not only decouples the torque and flux which provides faster response but also makes the control task easy. The performance of the proposed drive is simulated. The advantages of the proposed drive are confirmed by the simulation results.
Abstract: Nonlinear and unbalance loads in three phase
networks create harmonics and losses. Active and passive filters are
used for elimination or reduction of these effects. Passive filters have
some limitations. For example, they are designed only for a specific
frequency and they may cause to resonance in the network at the
point of common coupling. The other drawback of a passive filter is
that the sizes of required elements are normally large. The active
filter can improve some of limitations of passive filter for example;
they can eliminate more than one harmonic and don't cause resonance
in the network. In this paper inverter analysis have been done
simultaneously in three phase and the RL impedance of the line have
been considered. A sliding mode control based on energy feedback of
capacitors is employed in the design with this method, the dynamic
speed of the filter is improved effectively and harmonics and load
unbalance is compensating quickly.
Abstract: A nonlinear model of two-beam free-electron laser
(FEL) in the absence of slippage is presented. The two beams are
assumed to be cold with different energies and the fundamental
resonance of the higher energy beam is at the third harmonic of lower
energy beam. By using Maxwell-s equations and full Lorentz force
equations of motion for the electron beams, coupled differential
equations are derived and solved numerically by the fourth order
Runge–Kutta method. In this method a considerable growth of third
harmonic electromagnetic field in the XUV and X-ray regions is
predicted.
Abstract: Harmonic pollution and low power factor in power
systems caused by power converters have been of great concern. To
overcome these problems several converter topologies using
advanced semiconductor devices and control schemes have been
proposed. This investigation is to identify a low cost, small size,
efficient and reliable ac to dc converter to meet the input performance
index of UPS. The performance of single phase and three phase ac to
dc converter along with various control techniques are studied and
compared. The half bridge converter topology with linear current
control is identified as most suitable. It is simple, energy efficient
because of single switch power loss and transformer-less operation of
UPS. The results are validated practically using a prototype built
using IGBT and analog controller. The performance for both single
and three-phase system is verified. Digital implementation of closed
loop control achieves higher reliability. Its cost largely depends on
chosen bit precision. The minimal bit precision for optimum
converter performance is identified as 16-bit with fixed-point
operation. From the investigation and practical implementation it is
concluded that half bridge ac – dc converter along with digital linear
controller meets the performance index of UPS for single and three
phase systems.
Abstract: DC-DC converters are widely used in regulated switched mode power supplies and in DC motor drive applications. There are several sources of unwanted nonlinearity in practical power converters. In addition, their operation is characterized by switching that gives birth to a variety of nonlinear dynamics. DC-DC buck and boost converters controlled by pulse-width modulation (PWM) have been simulated. The voltage waveforms and attractors obtained from the circuit simulation have been studied. With the onset of instability, the phenomenon of subharmonic oscillations, quasi-periodicity, bifurcations, and chaos have been observed. This paper is mainly motivated by potential contributions of chaos theory in the design, analysis and control of power converters, in particular and power electronics circuits, in general.
Abstract: Application of neural networks in execution of
programmed pulse width modulation (PPWM) of a voltage source
inverter (VSI) is studied in this paper. Using the proposed method it is
possible to cancel out the desired harmonics in output of VSI in
addition to control the magnitude of fundamental harmonic,
contineously. By checking the non-trained values and a performance
index, the most appropriate neural network is proposed. It is shown
that neural networks may solve the custom difficulties of practical
utilization of PPWM such as large size of memory, complex digital
circuits and controlling the magnitude of output voltage in a discrete
manner.
Abstract: In this paper, we analyze the rotor eddy currents losses provoqued by the stator slot harmonics developed in the permanent magnets or pole pieces of synchronous machines. An analytical approach is presented to evaluate the effect of slot ripples on rotor field and losses calculation. This analysis is then tested on a model by 2D/3D finite element (FE) calculation. The results show a good agreement on loss calculations when skin effect is negligible and the magnet is considered.
Abstract: The perfect operation of common Active Filters is depended on accuracy of identification system distortion. Also, using a suitable method in current injection and reactive power compensation, leads to increased filter performance. Due to this fact, this paper presents a method based on predictive current control theory in shunt active filter applications. The harmonics of the load current is identified by using o–d–q reference frame on load current and eliminating the DC part of d–q components. Then, the rest of these components deliver to predictive current controller as a Threephase reference current by using Park inverse transformation. System is modeled in discreet time domain. The proposed method has been tested using MATLAB model for a nonlinear load (with Total Harmonic Distortion=20%). The simulation results indicate that the proposed filter leads to flowing a sinusoidal current (THD=0.15%) through the source. In addition, the results show that the filter tracks the reference current accurately.
Abstract: This paper describes a new method for extracting the fetal heart rate (fHR) and the fetal heart rate variability (fHRV) signal non-invasively using abdominal maternal electrocardiogram (mECG) recordings. The extraction is based on the fundamental frequency (Fourier-s) theorem. The fundamental frequency of the mother-s electrocardiogram signal (fo-m) is calculated directly from the abdominal signal. The heart rate of the fetus is usually higher than that of the mother; as a result, the fundamental frequency of the fetal-s electrocardiogram signal (fo-f) is higher than that of the mother-s (fo-f > fo-m). Notch filters to suppress mother-s higher harmonics were designed; then a bandpass filter to target fo-f and reject fo-m is implemented. Although the bandpass filter will pass some other frequencies (harmonics), we have shown in this study that those harmonics are actually carried on fo-f, and thus have no impact on the evaluation of the beat-to-beat changes (RR intervals). The oscillations of the time-domain extracted signal represent the RR intervals. We have also shown in this study that zero-to-zero evaluation of the periods is more accurate than the peak-to-peak evaluation. This method is evaluated both on simulated signals and on different abdominal recordings obtained at different gestational ages.
Abstract: Nonlinear response behaviour of a cracked RC beam under harmonic excitation is analysed to investigate various instability phenomena like, bifurcation, jump phenomena etc. The nonlinearity of the system arises due to opening and closing of the cracks in the RC beam and is modelled as a cubic polynomial. In order to trace different branches at the bifurcation point on the response curve (amplitude versus frequency of excitation plot), an arc length continuation technique along with the incremental harmonic balance (IHBC) method is employed. The stability of the solution is investigated by the Floquet theory using Hsu-s scheme. The periodic solutions obtained by the IHBC method are compared with these obtained by the numerical integration of the equation of motion. Characteristics of solutions fold bifurcation, jump phenomena and from stable to unstable zones are identified.
Abstract: This paper proposes a feed-forward control in
resonant dc link inverter. The feed-forward control configuration is
based on synchronous sigma-delta modulation. The simulation
results showing the proposed technique can reject non-ideal dc bus
improving the total harmonic distortion.
Abstract: The electric power industry is currently undergoing an unprecedented reform. One of the most exciting and potentially profitable recent developments is increasing usage of artificial intelligence techniques. The intention of this paper is to give an overview of using neural network (NN) techniques in power systems. According to the growth rate of NNs application in some power system subjects, this paper introduce a brief overview in fault diagnosis, security assessment, load forecasting, economic dispatch and harmonic analyzing. Advantages and disadvantages of using NNs in above mentioned subjects and the main challenges in these fields have been explained, too.
Abstract: In this paper, a necessary and sufficient coefficient are given for functions in a class of complex valued meromorphic harmonic univalent functions of the form f = h + g using Salagean operator. Furthermore, distortion theorems, extreme points, convolution condition and convex combinations for this family of meromorphic harmonic functions are obtained.
Abstract: A new topology of unified power quality conditioner
(UPQC) is proposed for different power quality (PQ) improvement in
a three-phase four-wire (3P-4W) distribution system. For neutral
current mitigation, a star-hexagon transformer is connected in shunt
near the load along with three-leg voltage source inverters (VSIs)
based UPQC. For the mitigation of source neutral current, the uses of
passive elements are advantageous over the active compensation due
to ruggedness and less complexity of control. In addition to this, by
connecting a star-hexagon transformer for neutral current mitigation
the over all rating of the UPQC is reduced. The performance of the
proposed topology of 3P-4W UPQC is evaluated for power-factor
correction, load balancing, neutral current mitigation and mitigation
of voltage and currents harmonics. A simple control algorithm based
on Unit Vector Template (UVT) technique is used as a control
strategy of UPQC for mitigation of different PQ problems. In this
control scheme, the current/voltage control is applied over the
fundamental supply currents/voltages instead of fast changing APFs
currents/voltages, thereby reducing the computational delay.
Moreover, no extra control is required for neutral source current
compensation; hence the numbers of current sensors are reduced. The
performance of the proposed topology of UPQC is analyzed through
simulations results using MATLAB software with its Simulink and
Power System Block set toolboxes.
Abstract: In this paper, the effects of the restoring force device on the response of a space frame structure resting on sliding type of bearing with a restoring force device is studied. The NS component of the El - Centro earthquake and harmonic ground acceleration is considered for earthquake excitation. The structure is modeled by considering six-degrees of freedom (three translations and three rotations) at each node. The sliding support is modeled as a fictitious spring with two horizontal degrees of freedom. The response quantities considered for the study are the top floor acceleration, base shear, bending moment and base displacement. It is concluded from the study that the displacement of the structure reduces by the use of the restoring force device. Also, the peak values of acceleration, bending moment and base shear also decreases. The simulation results show the effectiveness of the developed and proposed method.
Abstract: Nowadays in applications of renewable energy sources
it is important to develop powerful and energy-saving photovoltaic
converters and to keep the prescriptions of the standards. In grid
connected PV converters the obvious solution to increase the
efficiency is to reduce the switching losses. Our new developed
control method reduces the switching losses and keeps the limitations
of the harmonic distortion standards. The base idea of the method is
the utilization of 3-state control causing discontinuous current mode
at low input power. In the following sections the control theory, the