Abstract: Many computational techniques were applied to
solution of heat conduction problem. Those techniques were the
finite difference (FD), finite element (FE) and recently meshless
methods. FE is commonly used in solution of equation of heat
conduction problem based on the summation of stiffness matrix of
elements and the solution of the final system of equations. Because
of summation process of finite element, convergence rate was
decreased. Hence in the present paper Cellular Automata (CA)
approach is presented for the solution of heat conduction problem.
Each cell considered as a fixed point in a regular grid lead to the
solution of a system of equations is substituted by discrete systems of
equations with small dimensions. Results show that CA can be used
for solution of heat conduction problem.
Abstract: It is known that if harmonic spectra are decreased, then
acoustic noise also decreased. Hence, this paper deals with a new
random switching strategy using DSP TMS320F2812 to decrease the
harmonics spectra of single phase switched reluctance motor. The
proposed method which combines random turn-on, turn-off angle
technique and random pulse width modulation technique is shown. A
harmonic spread factor (HSF) is used to evaluate the random
modulation scheme. In order to confirm the effectiveness of the new
method, the experimental results show that the harmonic intensity of
output voltage for the proposed method is better than that for
conventional methods.
Abstract: This paper presents a fast and efficient on-line technique for estimating impedance of unbalanced loads in power systems. The proposed technique is an application of a discrete timedynamic filter based on stochastic estimation theory which is suitable for estimating parameters in noisy environment. The algorithm uses sets of digital samples of the distorted voltage and current waveforms of the non-linear load to estimate the harmonic contents of these two signal. The non-linear load impedance is then calculated from these contents. The method is tested using practical data. Results are reported and compared with those obtained using the conventional least error squares technique. In addition to the very accurate results obtained, the method can detect and reject bad measurements. This can be considered as a very important advantage over the conventional static estimation methods such as the least error square method.
Abstract: This paper presents a novel control strategy of a threephase
four-wire Unified Power Quality (UPQC) for an improvement
in power quality. The UPQC is realized by integration of series and
shunt active power filters (APFs) sharing a common dc bus capacitor.
The shunt APF is realized using a thee-phase, four leg voltage source
inverter (VSI) and the series APF is realized using a three-phase,
three leg VSI. A control technique based on unit vector template
technique (UTT) is used to get the reference signals for series APF,
while instantaneous sequence component theory (ISCT) is used for
the control of Shunt APF. The performance of the implemented
control algorithm is evaluated in terms of power-factor correction,
load balancing, neutral source current mitigation and mitigation of
voltage and current harmonics, voltage sag and swell in a three-phase
four-wire distribution system for different combination of linear and
non-linear loads. In this proposed control scheme of UPQC, the
current/voltage control is applied over the fundamental supply
currents/voltages instead of fast changing APFs currents/voltages,
there by reducing the computational delay and the required sensors.
MATLAB/Simulink based simulations are obtained, which support
the functionality of the UPQC. MATLAB/Simulink based
simulations are obtained, which support the functionality of the
UPQC.
Abstract: A high-frequency low-power sinusoidal quadrature
oscillator is presented through the use of two 2nd-order low-pass
current-mirror (CM)-based filters, a 1st-order CM low-pass filter and
a CM bilinear transfer function. The technique is relatively simple
based on (i) inherent time constants of current mirrors, i.e. the
internal capacitances and the transconductance of a diode-connected
NMOS, (ii) a simple negative resistance RN formed by a resistor load
RL of a current mirror. Neither external capacitances nor inductances
are required. As a particular example, a 1.9-GHz, 0.45-mW, 2-V
CMOS low-pass-filter-based all-current-mirror sinusoidal quadrature
oscillator is demonstrated. The oscillation frequency (f0) is 1.9 GHz
and is current-tunable over a range of 370 MHz or 21.6 %. The
power consumption is at approximately 0.45 mW. The amplitude
matching and the quadrature phase matching are better than 0.05 dB
and 0.15°, respectively. Total harmonic distortions (THD) are less
than 0.3 %. At 2 MHz offset from the 1.9 GHz, the carrier to noise
ratio (CNR) is 90.01 dBc/Hz whilst the figure of merit called a
normalized carrier-to-noise ratio (CNRnorm) is 153.03 dBc/Hz. The
ratio of the oscillation frequency (f0) to the unity-gain frequency (fT)
of a transistor is 0.25. Comparisons to other approaches are also
included.
Abstract: This paper proposes a feed-forward control in a halfbridge
resonant dc link inverter. The configuration of feed-forward
control is based on synchronous sigma-delta modulation and the halfbridge
resonant dc link inverter consists of two inductors, one
capacitor and two power switches. The simulation results show the
proposed technique can reject non-ideal dc bus improving the total
harmonic distortion.