Abstract: Solar Cells are destined to supply electric energy beginning from primary resources. It can charge a battery up to 12V dc. For residential use an inverter for 12V dc to 220Vac conversion is desired. For this a static DC-AC converter is necessarily inserted between the solar cells and the distribution network. This paper describes a new P.W.M. strategy for a voltage source inverter. This modulation strategy reduces the energy losses and harmonics in the P.W.M. voltage source inverter. This technique allows the P.W.M. voltage source inverter to become a new feasible solution for solar home application.
Abstract: This paper presents an optimal design of poly-phase induction motor using Quadratic Interpolation based Particle Swarm Optimization (QI-PSO). The optimization algorithm considers the efficiency, starting torque and temperature rise as objective function (which are considered separately) and ten performance related items including harmonic current as constraints. The QI-PSO algorithm was implemented on a test motor and the results are compared with the Simulated Annealing (SA) technique, Standard Particle Swarm Optimization (SPSO), and normal design. Some benchmark problems are used for validating QI-PSO. From the test results QI-PSO gave better results and more suitable to motor-s design optimization. Cµ code is used for implementing entire algorithms.
Abstract: This paper aims to present the reviews of the
application of neural network in shunt active power filter (SAPF).
From the review, three out of four components of SAPF structure,
which are harmonic detection component, compensating current
control, and DC bus voltage control, have been adopted some of
neural network architecture as part of its component or even
substitution. The objectives of most papers in using neural network in
SAPF are to increase the efficiency, stability, accuracy, robustness,
tracking ability of the systems of each component. Moreover,
minimizing unneeded signal due to the distortion is the ultimate goal
in applying neural network to the SAPF. The most famous
architecture of neural network in SAPF applications are ADALINE
and Backpropagation (BP).
Abstract: Personal computers draw non-sinusoidal current
with odd harmonics more significantly. Power Quality of
distribution networks is severely affected due to the flow of these
generated harmonics during the operation of electronic loads. In
this paper, mathematical modeling of odd harmonics in current like
3rd, 5th, 7th and 9th influencing the power quality has been presented.
Live signals have been captured with the help of power quality
analyzer for analysis purpose. The interesting feature is that Total
Harmonic Distortion (THD) in current decreases with the increase
of nonlinear loads has been verified theoretically. The results
obtained using mathematical expressions have been compared with
the practical results and exciting results have been found.
Abstract: This paper proposes a synchronized random switching frequency pulse width modulation (SRSFPWM). In this technique, the clock signal is used to control the random noise frequency which is produced by the feedback voltage of a hysteresis circuit. These make the triangular carrier frequency equaling to the random noise frequency in each switching period with the symmetrical positive and negative slopes of triangular carrier. Therefore, there is no error voltage in PWM signal. The PSpice simulated results shown the proposed technique improved the performance in case of low frequency harmonics of PWM signal comparing with conventional random switching frequency PWM.
Abstract: A numerical method for solving the time-independent Schrödinger equation of a particle moving freely in a three-dimensional
axisymmetric region is developed. The boundary of the region
is defined by an arbitrary analytic function. The method uses a
coordinate transformation and an expansion in eigenfunctions. The
effectiveness is checked and confirmed by applying the method to a
particular example, which is a prolate spheroid.
Abstract: Custom power is a technology driven product and
service solution which embraces a family devices such as Dynamic
Voltage Restorer (DVR), Distributed Shunt Compensator
(DSTATCOM), Solid State Breaker (SSB) etc which will provide
power quality functions at distribution voltages. The rapid response
of these devices enables them to operate in real time, providing
continuous and dynamic control of the supply including voltage and
reactive power regulation, harmonic reduction and elimination of
voltage dips. This paper presents the benefits of multilevel inverters
when they are used for DPC based custom power devices. Power
flow control mechanism, salient features, advantages and
disadvantages of direct power control (DPC) using lookup table,
SVM, predictive voltage vector and hybrid DPC strategies are
discussed in this paper. Simulation results of three level inverter
based STATCOM, harmonic analysis of multi level inverters are
presented at the end.
Abstract: In this paper the authors propose a flexible electronic solution, to improve the energetic efficiency of a thermo plant. This is achieved by replacing the mechanical gear box, placed traditionally between a gas turbine and a synchronous generator; by a power electronic converter. After reminding problematic of gear boxes and interest of a proposed electronic solution in high power plants, the authors describe a new control strategy for an indirect frequency converter, which is characterized by its high efficiency due to the use of SWM: Square Wave Modulation. The main advantage of this mode is the quasi absence of switching losses. A control method is also proposed to resolve some problems incurred by using square wave modulation, in particular to reduce the harmonics distortion of the output inverter voltage and current. Simulation examples as well as experimental results are included.
Abstract: To maximise furnace production it-s necessary to
optimise furnace control, with the objectives of achieving maximum
power input into the melting process, minimum network distortion
and power-off time, without compromise on quality and safety. This
can be achieved with on the one hand by an appropriate electrode
control and on the other hand by a minimum of AC transformer
switching.
Electrical arc is a stochastic process; witch is the principal cause
of power quality problems, including voltages dips, harmonic
distortion, unbalance loads and flicker. So it is difficult to make an
appropriate model for an Electrical Arc Furnace (EAF). The factors
that effect EAF operation are the melting or refining materials,
melting stage, electrode position (arc length), electrode arm control
and short circuit power of the feeder. So arc voltages, current and
power are defined as a nonlinear function of the arc length. In this
article we propose our own empirical function of the EAF and model,
for the mean stages of the melting process, thanks to the
measurements in the steel factory.
Abstract: The range of the output power is a very important and evident limitation of two-level inverters. In order to overcome this disadvantage, multilevel inverters are introduced. Recently, Cascade H-Bridge inverters have emerged as one of the popular converter topologies used in numerous industrial applications. The modulation switching strategies such as phase shifted carrier based Pulse Width Modulation (PWM) technique and Stair case modulation with Selective Harmonic Elimination (SHE) PWM technique are generally used. NR method is used to solve highly non linear transcendental equations which are formed by SHEPWM method. Generally NR method has a drawback of requiring good initial guess but in this paper a new approach is implemented for NR method with any random initial guess. A three phase CHB 11-level inverter is chosen for analysis. MATLAB/SIMULINK programming environment and harmonic profiles are compared. Finally this paper presents a method at fundamental switching frequency with least % THDV.
Abstract: This paper proposes a three-phase four-wire currentcontrolled
Voltage Source Inverter (CC-VSI) for both power quality
improvement and PV energy extraction. For power quality
improvement, the CC-VSI works as a grid current-controlling shunt
active power filter to compensate for harmonic and reactive power of
loads. Then, the PV array is coupled to the DC bus of the CC-VSI
and supplies active power to the grid. The MPPT controller employs
the particle swarm optimization technique. The output of the MPPT
controller is a DC voltage that determines the DC-bus voltage
according to PV maximum power. The PSO method is simple and
effective especially for a partially shaded PV array. From computer
simulation results, it proves that grid currents are sinusoidal and inphase
with grid voltages, while the PV maximum active power is
delivered to loads.
Abstract: The paper deals with the comparison study of
harmonic detection methods for a shunt active power filter. The
%THD and the power factor value at the PCC point after
compensation are considered for the comparison. There are three
harmonic detection methods used in the paper that are synchronous
reference frame method, synchronous detection method, and DQ axis
with Fourier method. In addition, the ideal current source is used to
represent the active power filter by assuming an infinitely fast
controller action of the active power filter. The simulation results
show that the DQ axis with Fourier method provides the minimum
%THD after compensation compared with other methods. However,
the power factor value at the PCC point after compensation is slightly
lower than that of synchronous detection method.
Abstract: The proper selection of the AC-side passive filter
interconnecting the voltage source converter to the power supply is
essential to obtain satisfactory performances of an active power filter
system. The use of the LCL-type filter has the advantage of
eliminating the high frequency switching harmonics in the current
injected into the power supply. This paper is mainly focused on
analyzing the influence of the interface filter parameters on the active
filtering performances. Some design aspects are pointed out. Thus,
the design of the AC interface filter starts from transfer functions by
imposing the filter performance which refers to the significant current
attenuation of the switching harmonics without affecting the
harmonics to be compensated. A Matlab/Simulink model of the entire
active filtering system including a concrete nonlinear load has been
developed to examine the system performances. It is shown that a
gamma LC filter could accomplish the attenuation requirement of the
current provided by converter. Moreover, the existence of an optimal
value of the grid-side inductance which minimizes the total harmonic
distortion factor of the power supply current is pointed out.
Nevertheless, a small converter-side inductance and a damping
resistance in series with the filter capacitance are absolutely needed
in order to keep the ripple and oscillations of the current at the
converter side within acceptable limits. The effect of change in the
LCL-filter parameters is evaluated. It is concluded that good active
filtering performances can be achieved with small values of the
capacitance and converter-side inductance.
Abstract: Post-anthesis drought stress is the most important
problem affecting wheat production in dryland fields, specially in
Mediterranean regions. The main objective of this research was to
evaluate drought tolerance indices in dryland wheat genotypes under
post-anthesis drought stress. The research was including two different
experiments. In each experiment, twenty dryland bread wheat
genotypes were sown in a randomized complete blocks design
(RCBD) with three replications. One of experiments belonged to
rain-fed conditions (post-anthesis drought stress) and other
experiment was under non-stress conditions (with supplemental
irrigation). Different drought tolerance indices include Stress
Tolerance (Tol), Mean Productivity (MP), Geometric Mean
Productivity (GMP), Stress Susceptibility Index (SSI), Stress
Tolerance Index (STI), Harmonic Mean (HAM), Yield Index (YI)
and Yield Stability Index (YSI) were evaluate based on grain yield
under rain-fed (Ys) and supplemental irrigation (Yp) environments.
G10 and G12 were the most tolerant genotypes based on TOL and
SSI. But, based on MP, GMP, STI, HAM and YI indices, G1 and G2
were selected. STI, GMP and MP indices had high correlation with
grain yield under rain-fed and supplementary irrigation conditions
and were recognized as appropriate indices to identify genotypes with
high grain yield and low sensitivity to drought stress environments.
Abstract: In this paper, we research the standard 13-point difference schemes for solving the biharmonic equation. Heuristic method is applied to judging the stability of multi-level difference schemes of the biharmonic equation. It is showed that the standard 13-point difference schemes are stable.
Abstract: This paper, a simple continuous conduction mode (CCM) pulse-width-modulated (PWM) controller for high power factor boost converters is introduced. The duty ratios were obtained by the comparison of a sensed signal from inductor current or switch current and a negative slope ramp carrier waveform in each switching period. Due to the proposed control requires only the inductor current or switch current sensor and the output voltage sensor, its circuit implementation was very simple. To verify the proposed control, the circuit experimentation of a 350 W boost converter with the proposed control was applied. From the results, the input current waveform was shaped to be closely sinusoidal, implying high power factor and low harmonics.
Abstract: In present communication, we have developed the
suitable constraints for the given the mean codeword length and the
measures of entropy. This development has proved that Renyi-s
entropy gives the minimum value of the log of the harmonic mean
and the log of power mean. We have also developed an important
relation between best 1:1 code and the uniquely decipherable code by
using different measures of entropy.
Abstract: Wind turbines with double output induction
generators can operate at variable speed permitting conversion
efficiency maximization over a wide range of wind velocities. This
paper presents the performance analysis of a wind driven double
output induction generator (DOIG) operating at varying shafts speed.
A periodic transient state analysis of DOIG equipped with two
converters is carried out using a hybrid induction machine model.
This paper simulates the harmonic content of waveforms in various
points of drive at different speeds, based on the hybrid model
(dqabc). Then the sinusoidal and trapezoidal pulse-width–modulation
control techniques are used in order to improve the power factor of
the machine and to weaken the injected low order harmonics to the
supply. Based on the frequency spectrum, total harmonics distortion,
distortion factor and power factor. Finally advantages of sinusoidal
and trapezoidal pulse width modulation techniques are compared.
Abstract: Most electrical distribution systems are incurring large
losses as the loads are wide spread, inadequate reactive power
compensation facilities and their improper control. A typical static
VAR compensator consists of capacitor bank in binary sequential
steps operated in conjunction with a thyristor controlled reactor of the
smallest step size. This SVC facilitates stepless control of reactive
power closely matching with load requirements so as to maintain
power factor nearer to unity. This type of SVC-s requiring a
appropriately controlled TCR. This paper deals with an air cored
reactor suitable for distribution transformer of 3phase, 50Hz, Dy11,
11KV/433V, 125 KVA capacity. Air cored reactors are designed,
built, tested and operated in conjunction with capacitor bank in five
binary sequential steps. It is established how the delta connected TCR
minimizes the harmonic components and the operating range for
various electrical quantities as a function of firing angle is
investigated. In particular firing angle v/s line & phase currents, D.C.
components, THD-s, active and reactive powers, odd and even triplen
harmonics, dominant characteristic harmonics are all investigated and
range of firing angle is fixed for satisfactory operation. The harmonic
spectra for phase and line quantities at specified firing angles are
given. In case the TCR is operated within the bound specified in this
paper established through simulation studies are yielding the best
possible operating condition particularly free from all dominant
harmonics.
Abstract: This paper present a MATLAB-SIMULINK model of a single phase 2.5 KVA, 240V RMS controlled PV VSI (Photovoltaic Voltage Source Inverter) inverter using IGBTs (Insulated Gate Bipolar Transistor). The behavior of output voltage, output current, and the total harmonic distortion (THD), with the variation in input dc blocking capacitor (Cdc), for linear and non-linear load has been analyzed. The values of Cdc as suggested by the other authors in their papers are not clearly defined and it poses difficulty in selecting the proper value. As the dc power stored in Cdc, (generally placed parallel with battery) is used as input to the VSI inverter. The simulation results shows the variation in the output voltage and current with different values of Cdc for linear and non-linear load connected at the output side of PV VSI inverter and suggest the selection of suitable value of Cdc.