Abstract: Carbon nanotubes (CNTs) are attractive because of
their excellent chemical durability mechanical strength and electrical
properties. Therefore there is interest in CNTs for not only electrical
and mechanical application, but also biological and medical
application.
In this study, the dispersion power of surfactant-treated multiwalled
carbon nanotubes (MWCNTs) and their effect on the antibacterial
activity were examined. Surfactant was used sodium
dodecyl-benzenesulfonate (SDBS). UV-vis absorbance and
transmission electron microscopy(TEM) were used to characterize the
dispersion of MWCNTs in the aqueous phase, showing that the
surfactant molecules had been adsorbed onto the MWCNTs surface.
The surfactant-treated MWCNTs exhibited antimicrobial activities
to streptococcus mutans. The optical density growth curves and viable
cell number determined by the plating method suggested that the
antimicrobial activity of surfactant-treated MWCNTs was both
concentration and treatment time-dependent.
Abstract: Electrical resistivity is a fundamental parameter of metals or electrical conductors. Since resistivity is a function of temperature, in order to completely understand the behavior of metals, a temperature dependent theoretical model is needed. A model based on physics principles has recently been developed to obtain an equation that relates electrical resistivity to temperature. This equation is dependent upon a parameter associated with the electron travel time before being scattered, and a parameter that relates the energy of the atoms and their separation distance. Analysis of the energy parameter reveals that the equation is optimized if the proportionality term in the equation is not constant but varies over the temperature range. Additional analysis reveals that the theoretical equation can be used to determine the mean free path of conduction electrons, the number of defects in the atomic lattice, and the ‘equivalent’ charge associated with the metallic bonding of the atoms. All of this analysis provides validation for the theoretical model and provides insight into the behavior of metals where performance is affected by temperatures (e.g., integrated circuits and temperature sensors).
Abstract: The voltage/current characteristics and the effect of
NO2 gas on the electrical conductivity of a PbPc gas sensor array is
investigated. The gas sensor is manufactured using vacuum
deposition of gold electrodes on sapphire substrate with the leadphathalocyanine
vacuum sublimed on the top of the gold electrodes.
Two versions of the PbPc gas sensor array are investigated. The
tested types differ in the gap sizes between the deposited gold
electrodes. The sensors are tested at different temperatures to account
for conductivity changes as the molecular adsorption/desorption rate
is affected by heat. The obtained results found to be encouraging as
the sensors shoed stability and sensitivity towards low concentration
of applied NO2 gas.
Abstract: The objective of present work is to stimulate the
machining of material by electrical discharge machining (EDM) to
give effect of input parameters like discharge current (Ip), pulse on
time (Ton), pulse off time (Toff) which can bring about changes in the
output parameter, i.e. material removal rate. Experimental data was
gathered from die sinking EDM process using copper electrode and
Medium Carbon Steel (AISI 1040) as work-piece. The rules of
membership function (MF) and the degree of closeness to the
optimum value of the MMR are within the upper and lower range of
the process parameters. It was found that proposed fuzzy model is in
close agreement with the experimental results. By Intelligent, model
based design and control of EDM process parameters in this study
will help to enable dramatically decreased product and process
development cycle times.
Abstract: In this paper, the data correction algorithm is suggested
when the environmental air temperature varies. To correct the infrared
data in this paper, the initial temperature or the initial infrared image
data is used so that a target source system may not be necessary. The
temperature data obtained from infrared detector show nonlinear
property depending on the surface temperature. In order to handle this
nonlinear property, Taylor series approach is adopted. It is shown that
the proposed algorithm can reduce the influence of environmental
temperature on the components in the board. The main advantage of
this algorithm is to use only the initial temperature of the components
on the board rather than using other reference device such as black
body sources in order to get reference temperatures.
Abstract: Salinity is a measure of the amount of salts in the
water. Total Dissolved Solids (TDS) as salinity parameter are often
determined using laborious and time consuming laboratory tests, but
it may be more appropriate and economical to develop a method
which uses a more simple soil salinity index. Because dissolved ions
increase salinity as well as conductivity, the two measures are
related. The aim of this research was determine of constant
coefficients for predicting of Total Dissolved Solids (TDS) based on
Electrical Conductivity (EC) with Statistics of Correlation
coefficient, Root mean square error, Maximum error, Mean Bias
error, Mean absolute error, Relative error and Coefficient of residual
mass. For this purpose, two experimental areas (S1, S2) of Khuzestan
province-IRAN were selected and four treatments with three
replications by series of double rings were applied. The treatments
were included 25cm, 50cm, 75cm and 100cm water application. The
results showed the values 16.3 & 12.4 were the best constant
coefficients for predicting of Total Dissolved Solids (TDS) based on
EC in Pilot S1 and S2 with correlation coefficient 0.977 & 0.997 and
191.1 & 106.1 Root mean square errors (RMSE) respectively.
Abstract: Properties of cement pastes with fine-ground ceramics
used as an alternative binder replacing Portland cement up to 20% of
its mass are investigated. At first, the particle size distribution of
cement and fine-ground ceramics is measured using laser analyser.
Then, the material properties are studied in the early hardening
period up to 28 days. The hydration process of studied materials is
monitored by electrical conductivity measurement using TDR
sensors. The changes of materials- structures within the hardening are
observed using pore size distribution measurement. The compressive
strength measurements are done as well. Experimental results show
that the replacement of Portland cement by fine-ground ceramics in
the amount of up to 20% by mass is acceptable solution from the
mechanical point of view. One can also assume similar physical
properties of designed materials to the reference material with only
Portland cement as binder.
Abstract: The system is made with main distributed components:
First Level: Industrial Computers placed in Control Room (monitors thermal and electrical processes based on the data provided by the second level); Second Level: PLCs which collects data from process and transmits information on the first level; also takes commands from this level which are further, passed to execution elements from third
level; Third Level: field elements consisting in 3 categories: data collecting elements; data transfer elements from the third level to the second; execution elements which take commands from the second
level PLCs and executes them after which transmits the confirmation of execution to them. The purpose of the automatic functioning is the optimization of the co-generative electrical energy commissioning in the national
energy system and the commissioning of thermal energy to the consumers.
The integrated system treats the functioning of all the equipments and devices as a whole: Gas Turbine Units (GTU); MT 20kV Medium Voltage Station (MVS); 0,4 kV Low Voltage Station (LVS); Main Hot Water Boilers (MHW); Auxiliary Hot Water Boilers (AHW); Gas Compressor Unit (GCU); Thermal Agent Circulation
Pumping Unit (TPU); Water Treating Station (WTS).
Abstract: Films of pure tin oxide SnO2 and in presence of
antimony atoms (SnO2-Sb) deposited onto glass substrates have
shown a sufficiently high energy gap to be transparent in the visible
region, a high electrical mobility and a carrier concentration which
displays a good electrical conductivity [1]. In this work, the effects of
polycrystalline silicon substrate on the optical properties of pure and
Sb doped tin oxide is investigated.
We used the APCVD (atmospheric pressure chemical vapour
deposition) technique, which is a low-cost and simple technique,
under nitrogen ambient, for growing this material. A series of SnO2
and SnO2-Sb have been deposited onto polycrystalline silicon
substrates with different contents of antimony atoms at the same
conditions of deposition (substrate temperature, flow oxygen,
duration and nitrogen atmosphere of the reactor). The effect of the
substrate in terms of morphology and nonlinear optical properties,
mainly the reflectance, was studied. The reflectance intensity of the
device, compared to the reflectance of tin oxide films deposited
directly on glass substrate, is clearly reduced on the overall
wavelength range. It is obvious that the roughness of the poly-c
silicon plays an important role by improving the reflectance and
hence the optical parameters.
A clear shift in the minimum of the reflectance upon doping level
is observed. This minimum corresponds to strong free carrier
absorption, resulting in different plasma frequency. This effect is
followed by an increase in the reflectance depending of the antimony
doping. Applying the extended Drude theory to the combining
optical and electrical obtained results these effects are discussed.
Abstract: In this paper, the computation of the electrical field distribution around AC high-voltage lines is demonstrated. The advantages and disadvantages of two different methods are described to evaluate the electrical field quantity. The first method is a seminumerical method using the laws of electrostatic techniques to simulate the two-dimensional electric field under the high-voltage overhead line. The second method which will be discussed is the finite element method (FEM) using specific boundary conditions to compute the two- dimensional electric field distributions in an efficient way.
Abstract: This paper presents the experimental results on effect of applied voltage stress frequency to the occurrence of electrical treeing in 22 kV cross linked polyethylene (XLPE) insulated cable.Hallow disk of XLPE insulating material with thickness 5 mm taken from unused high voltage cable was used as the specimen in this study. Stainless steel needle was inserted gradually into the specimen to give a tip to earth plane electrode separation of 2.50.2 mm at elevated temperature 105-110°C. The specimen was then annealed for 5 minute to minimize any mechanical stress build up around the needle-plane region before it was cooled down to room temperature. Each specimen were subjected to the same applied voltage stress level at 8 kV AC rms, with various frequency, 50, 100, 500, 1000 and 2000 Hz. Initiation time, propagation speed and pattern of electrical treeing were examined in order to study the effect of applied voltage stress frequency. By the experimental results, initial time of visible treeing decreases with increasing in applied voltage frequency. Also, obviously, propagation speed of electrical treeing increases with increasing in applied voltage frequency.Furthermore, two types of electrical treeing, bush-like and branch-like treeing were observed.The experimental results confirmed the effect of voltage stress frequency as well.
Abstract: Early breast cancer detection is an emerging field of
research as it can save the women infected by malignant tumors.
Microwave breast imaging is based on the electrical property contrast
between healthy and malignant tumor. This contrast can be detected
by use of microwave energy with an array of antennas that illuminate
the breast through coupling medium and by measuring the scattered
fields. In this paper, author has been presented the design and
simulation results of the bowtie antenna. This bowtie antenna is
designed for the detection of breast cancer detection.
Abstract: The objective of this research is to study the technical
and economic performance of wind/diesel/battery (W/D/B) system
supplying a remote small gathering of six families using HOMER
software package. The electrical energy is to cater for the basic needs
for which the daily load pattern is estimated. Net Present Cost (NPC)
and Cost of Energy (COE) are used as economic criteria, while the measure of performance is % of power shortage. Technical and
economic parameters are defined to estimate the feasibility of the
system under study. Optimum system configurations are estimated for two sites. Using HOMER software, the simulation results showed that W/D/B systems are economical for the assumed community sites
as the price of generated electricity is about 0.308 $/kWh, without
taking external benefits into considerations. W/D/B systems are more
economical than W/B or diesel alone systems, as the COE is 0.86 $/kWh for W/B and 0.357 $/kWh for diesel alone.
Abstract: Green house effect has becomes a serious concern in
many countries due to the increase consumption of the fossil fuel.
There have been many studies to find an alternative power source.
Wind energy found to be one of the most useful solutions to help in
overcoming the air pollution and global. There is no agreed solution
to conversion of wind energy to electrical energy. In this paper, the
advantages of using a Switched Reluctance Generator (SRG) for
wind energy applications. The theoretical study of the self excitation
of a SRG and the determination of the variable parameters in a SRG
design are discussed. The design parameters for the maximum power
output of the SRG are computed using Matlab simulation. The
designs of the circuit to control the variable parameters in a SRG to
provide the maximum power output are also discussed.
Abstract: ELS is an important ground based hardware in the
loop simulator used for aerodynamics torque loading experiments
of the actuators under test. This work focuses on improvement of the
transient response of torque controller with parameters uncertainty
of Electrical Load Simulator (ELS).The parameters of load simulator
are estimated online and the model is updated, eliminating the model
error and improving the steady state torque tracking response of
torque controller. To improve the Transient control performance the
gain of robust term of SMC is updated online using fuzzy logic
system based on the amount of uncertainty in parameters of load
simulator. The states of load simulator which cannot be measured
directly are estimated using luenberger observer with update of new
estimated parameters. The stability of the control scheme is verified
using Lyapunov theorem. The validity of proposed control scheme is
verified using simulations.
Abstract: Worldwide many electrical equipment insulation
failures have been reported caused by switching operations, while
those equipments had previously passed all the standard tests and
complied with all quality requirements. The problem is mostly
associated with high-frequency overvoltages generated during
opening or closing of a switching device. The transients generated
during switching operations in a Gas Insulated Substation (GIS) are
associated with high frequency components in the order of few tens
of MHz.
The frequency spectrum of the VFTO generated in the 220/66 kV
Wadi-Hoff GIS is analyzed using Fast Fourier Transform technique.
The main frequency with high voltage amplitude due to the operation
of disconnector (DS5) is 5 to 10 MHz, with the highest amplitude at 9
MHz. The main frequency with high voltage amplitude due to the
operation of circuit breaker (CB5) is 1 to 25 MHz, with the highest
amplitude at 2 MHz.
Mitigating techniques damped the oscillating frequencies
effectively. The using of cable terminal reduced the frequency
oscillation effectively than that of OHTL terminal. The using of a
shunt capacitance results in vanishing the high frequency
components. Ferrite rings reduces the high frequency components
effectively especially in the range 2 to 7 MHz. The using of RC and
RL filters results in vanishing the high frequency components.
Abstract: This paper describes the development of a control
system model using a graphical software tool. This control system is
part of an operator training simulator developed for the National
Training Center for Operators of Ixtapantongo (CNCAOI, acronym
according to its name in Spanish language) of the Mexico-s Federal
Commission of Electricity, CFE). The Department of Simulation of
the Electrical Research Institute (IIE) developed this simulator using
as reference the Unit I of the Combined Cycle Power Plant El Sauz,
located at the centre of Mexico. The first step in the project was the
developing of the Gas Turbine System and its control system
simulator. The Turbo Gas simulator was finished and delivered to
CNCAOI in March 2007 for commercial operation. This simulator is
a high-fidelity real time dynamic simulator built and tested for
accurate operation over the entire load range. The simulator was used
primarily for operator training although it has been used for
procedure development and evaluation of plant transients.
Abstract: Current spectrums of a high power induction machine was calculated for the cases of full symmetry, static and dynamic eccentricity. The calculations involve integration of 93 electrical plus four mechanical ordinary differential equations. Electrical equations account for variable inductances affected by slotting and eccentricities. The calculations were followed by Fourier analysis of the stator currents in steady state operation. The paper presents the stator current spectrums in full symmetry, static and dynamic eccentricity cases, and demonstrates the harmonics present in each case. The effect of dynamic eccentricity is demonstrating via comparing the current spectrums related to dynamic eccentricity cases with the full symmetry one. The paper includes one case study, refers to dynamic eccentricity, to present the spectrum of the measured current and demonstrate the existence of the harmonics related to dynamic eccentricity. The zooms of current spectrums around the main slot harmonic zone are included to simplify the comparison and prove the existence of the dynamic eccentricity harmonics in both calculated and measured current spectrums.
Abstract: Graphene-metal contact resistance limits the performance of graphene-based electrical devices. In this work, we have fabricated both graphene field-effect transistors (GFET) and transfer length measurement (TLM) test devices with titanium contacts. The purpose of this work is to compare the contact resistances that can be numerically extracted from the GFETs and measured from the TLM structures. We also provide a brief review of the work done in the field to solve the contact resistance problem.
Abstract: In this paper, we have examined the effect of process
parameter variation on the electrical characteristics of an LDMOS
device. The rate of change in the electrical parameters such as cut off
frequency, breakdown voltage and drain saturation current as a
function of the process parameters is investigated