Abstract: The seriously damaged structures during earthquakes
show the need and importance of design of reinforced concrete
structures with high ductility. Reinforced concrete beam-column
joints have an important function in all structures. Under seismic
excitation, the beam column joint region is subjected to horizontal
and vertical shear forces whose magnitude is many times higher than
the adjacent beam and column. Strength and ductility of structures
depends mainly on proper detailing of the reinforcement in beamcolumn
joints and the old structures were found ductility deficient.
DSP materials are obtained by using high quantities of super
plasticizers and high volumes of micro silica. In the case of High
Performance Densified Small Particle Concrete (HPDSPC), since
concrete is dense even at the micro-structure level, tensile strain
would be much higher than that of the conventional SFRC, SIFCON
& SIMCON. This in turn will improve cracking behaviour, ductility
and energy absorption capacity of composites in addition to
durability. The fine fibers used in our mix are 0.3mm diameter and 10
mm which can be easily placed with high percentage. These fibers
easily transfer stresses and act as a composite concrete unit to take up
extremely high loads with high compressive strength. HPDSPC
placed in the beam column joints helps in safety of human life due to
prolonged failure.
Abstract: The current study aims to highlight the loading
characteristics impact on the time evolution (focusing particularly on
long term effects) of the deformation of realized reinforced concrete
beams. Namely the tension stiffening code provisions (i.e. within
Eurocode 2) are reviewed with a clear intention to reassess their
operational value and predicting capacity. In what follows the
experimental programme adopted along with some preliminary
findings and numerical modeling attempts are presented. For a range of long slender reinforced concrete simply supported
beams (4200 mm) constant static sustained and repeated cyclic
loadings were applied mapping the time evolution of deformation.
All experiments were carried out at the Heavy Structures Lab of the
University of Leeds. During tests the mid-span deflection, creep
coefficient and shrinkage strains were monitored for duration of 90
days. The obtained results are set against the values predicted by
Eurocode 2 and the tools within an FE commercial package (i.e.
Midas FEA) to yield that existing knowledge and practise is at times
over-conservative.
Abstract: When high strength reinforced concrete is exposed to
high temperature due to a fire, deteriorations occur such as loss in
strength and elastic modulus, cracking and spalling of the concrete.
Therefore, it is important to understand risk of structural safety in
building structures by studying structural behaviors and rehabilitation
of fire damaged high strength concrete structures. This paper aims at
investigating rehabilitation effect on fire damaged high strength
concrete beams using experimental and analytical methods. In the
experiments, flexural specimens with high strength concrete are
exposed to high temperatures according to ISO 834 standard time
temperature curve. From four-point loading test, results show that
maximum loads of the rehabilitated beams are similar to or higher than
those of the non-fire damaged RC beam. In addition, structural
analyses are performed using ABAQUS 6.10-3 with same conditions
as experiments to provide accurate predictions on structural and
mechanical behaviors of rehabilitated RC beams. The parameters are
the fire cover thickness and strengths of repairing mortar. Analytical
results show good rehabilitation effects, when the results predicted
from the rehabilitated models are compared to structural behaviors of
the non-damaged RC beams. In this study, fire damaged high strength concrete beams are
rehabilitated using polymeric cement mortar. The predictions from the
finite element (FE) models show good agreements with the
experimental results and the modeling approaches can be used to
investigate applicability of various rehabilitation methods for further
study.
Abstract: In recent years, fire accidents have been steadily
increased and the amount of property damage caused by the accidents
has gradually raised. Damaging building structure, fire incidents bring
about not only such property damage but also strength degradation and
member deformation. As a result, the building structure undermines its
structural ability. Examining the degradation and the deformation is
very important because reusing the building is more economical than
reconstruction. Therefore, engineers need to investigate the strength
degradation and member deformation well, and make sure that they
apply right rehabilitation methods. This study aims at evaluating
deformation characteristics of fire damaged and rehabilitated normal
strength concrete beams through both experiments and finite element
analyses. For the experiments, control beams, fire damaged beams and
rehabilitated beams are tested to examine deformation characteristics.
Ten test beam specimens with compressive strength of 21MPa are
fabricated and main test variables are selected as cover thickness of
40mm and 50mm and fire exposure time of 1 hour or 2 hours. After
heating, fire damaged beams are air-recurred for 2 months and
rehabilitated beams are repaired with polymeric cement mortar after
being removed the fire damaged concrete cover. All beam specimens
are tested under four points loading. FE analyses are executed to
investigate the effects of main parameters applied to experimental
study. Test results show that both maximum load and stiffness of the
rehabilitated beams are higher than those of the fire damaged beams.
In addition, predicted structural behaviors from the analyses also show
good rehabilitation effect and the predicted load-deflection curves are
similar to the experimental results. For the further, the proposed
analytical method can be used to predict deformation characteristics of
fire damaged and rehabilitated concrete beams without suffering from
time and cost consuming of experimental process.
Abstract: Numerical investigations were conducted to study the
influence of flexural reinforcement ratio on the diagonal cracking
strength and ultimate shear strength of reinforced concrete (RC)
beams without stirrups. Three-dimensional nonlinear finite element
analyses (FEAs) of the beams with flexural reinforcement ratios
ranging from 0.58% to 2.20% subjected to a mid-span concentrated
load were carried out. It is observed that the load-deflection and loadstrain
curves obtained from the numerical analyses agree with those
obtained from the experiments. It is concluded that flexural
reinforcement ratio has a significant effect on the shear strength and
deflection capacity of RC beams without stirrups. The predictions of
diagonal cracking strength and ultimate shear strength of beams
obtained by using the equations defined by a number of codes and
researchers are compared with each other and with the experimental
values.
Abstract: A large amount of blast furnace slag is generated in
China. Most ground granulated blast furnace slag (GGBS) however
ends up in low-grade applications. Blast furnace slag, ground to an
appropriate fineness, can be used as a partial replacement of
cementitious material in concrete. The potential for using GGBS in
structural concrete, e.g. concrete beams and columns is investigated
at Xi’an Jiaotong-Liverpool University (XJTLU). With 50% of CEM
I cement replaced with GGBS, peak hydration temperatures
determined in a suspended concrete slab reduced by 20%. This
beneficiary effect has not been further improved with 70% of CEM I
replaced with GGBS. Partial replacement of CEM I with GGBS has a
retardation effect on the early-age strength of concrete. More GGBS
concrete mixes will be conducted to identify an ‘optimum’
replacement level which will lead to a reduced thermal loading,
without significantly compromising the early-age strength of
concrete.
Abstract: An experimental study was performed to investigate
the behavior and strength of proposed technique to connect
reinforced concrete (RC) beam to steel or composite columns. This
approach can practically be used in several types of building
construction. In this technique, the main beam of the frame consists
of a transfer part (part of beam; Tr.P) and a common reinforcement
concrete beam. The transfer part of the beam is connected to the
column, whereas the rest of the beam is connected to the transfer part
from each side. Four full-scale beam-column connections were tested
under static loading. The test parameters were the length of the
transfer part and the column properties. The test results show that
using of the transfer part technique leads to modify the deformation
capabilities for the RC beam and hence it increases its resistance
against failure. Increase in length of the transfer part did not
necessarily indicate an enhanced behavior. The test results contribute
to the characterization of the connection behavior between RC beam -
steel column and can be used to calibrate numerical models for the
simulation of this type of connection.
Abstract: In this paper, a nonlinear Finite Element Analysis
(FEA) was carried out using ANSYS software to build a model able
of predicting the behavior of Reinforced Concrete (RC) beams with
unbonded reinforcement. The FEA model was compared to existing
experimental data by other researchers. The existing experimental
data consisted of 16 beams that varied from structurally sound beams
to beams with unbonded reinforcement with different unbonded
lengths and reinforcement ratios. The model was able to predict the
ultimate flexural strength, load-deflection curve, and crack pattern of
concrete beams with unbonded reinforcement. It was concluded that
when the when the unbonded length is less than 45% of the span,
there will be no decrease in the ultimate flexural strength due to the
loss of bond between the steel reinforcement and the surrounding
concrete regardless of the reinforcement ratio. Moreover, when the
reinforcement ratio is relatively low, there will be no decrease in
ultimate flexural strength regardless of the length of unbond.
Abstract: The purpose of this study is to compare Self
Compacting Concrete (SCC) and Conventional Concrete (CC) in
terms of their capillary water absorption. During the comparison of
SCC and CC, the effects of two different factors were also
investigated: concrete strength class and curing condition. In the
study, both SCC and CC were produced in three different concrete
classes (C25, C50 and C70) and the other parameter (i.e. curing
condition) was determined as two levels: moisture and air curing. It
was observed that, for both curing environments and all strength
classes of concrete, SCCs had lower capillary water absorption values
than that of CCs. It was also detected that, for both SCC and CC,
capillary water absorption values of samples kept in moisture curing
were significantly lower than that of samples stored in air curing.
Additionally, it was determined that capillary water absorption values
for both SCC and CC decrease with increasing strength class of
concrete for both curing environments.
Abstract: The paper deals with current issues in research of
advanced methods to increase reliability of traditional timber
structural elements. It analyses the issue of strengthening of bent
timber beams, such as ceiling beams in old (historical) buildings with
additional concrete slab in combination with externally bonded fibre -
reinforced polymer. The paper describes experimental testing of
composite timber-concrete beam with FRP reinforcement and
compares results with FEM analysis.
Abstract: Well-designed composite steel and concrete structures
highlight the good material properties and lower the deficiencies of
steel and concrete, in particular they make use of high tensile strength
of steel and high stiffness of concrete. The most common composite
steel and concrete structure is a simply supported beam, which
concrete slab transferring the slab load to a beam is connected to the
steel cross-section. The aim of this paper is to find the most adequate
numerical model of a simply supported composite beam with the
cross-sectional and material parameters based on the results of a
processed parametric study and numerical analysis. The paper also
evaluates the suitability of using compact concrete with the
lightweight aggregates for composite steel and concrete beams. The
most adequate numerical model will be used in the resent future to
compare the results of laboratory tests.
Abstract: Self-Consolidating Concrete (SCC) is considered as a relatively new technology created as an effective solution to problems associated with low quality consolidation. A SCC mix is defined as successful if it flows freely and cohesively without the intervention of mechanical compaction. The construction industry is showing high tendency to use SCC in many contemporary projects to benefit from the various advantages offered by this technology.
At this point, a main question is raised regarding the effect of enhanced fluidity of SCC on the structural behavior of high strength self-consolidating reinforced concrete.
A three phase research program was conducted at the American University of Beirut (AUB) to address this concern. The first two phases consisted of comparative studies conducted on concrete and mortar mixes prepared with second generation Sulphonated Naphtalene-based superplasticizer (SNF) or third generation Polycarboxylate Ethers-based superplasticizer (PCE). The third phase of the research program investigates and compares the structural performance of high strength reinforced concrete beam specimens prepared with two different generations of superplasticizers that formed the unique variable between the concrete mixes. The beams were designed to test and exhibit flexure, shear, or bond splitting failure.
The outcomes of the experimental work revealed comparable resistance of beam specimens cast using self-compacting concrete and conventional vibrated concrete. The dissimilarities in the experimental values between the SCC and the control VC beams were minimal, leading to a conclusion, that the high consistency of SCC has little effect on the flexural, shear and bond strengths of concrete members.
Abstract: The aesthetic qualities and the versatility of reinforced
concrete have made it a popular choice for many architects and
structural engineers. Therefore, the exploration of natural materials
such as gravels and sands as well as lime-stone for cement production
is increasing to produce a concrete material. The exploration must
affect to the environment. Therefore, the using of the concrete
materials should be as efficient as possible. According to its natural
behavior of the concrete material, it is strong in compression and weak
in tension. Therefore the contribution of the tensile stresses of the
concrete to the flexural capacity of the beams is neglected. However,
removing of concrete on tension zone affects to the decreasing of
flexural capacity. Introduce the strut action of truss structures may an
alternative to solve the decreasing of flexural capacity. A series of
specimens were prepared to clarify the effect of the truss structures in
the concrete beams without concrete on the tension zone. Results
indicated that the truss system is necessary for the external reinforced
concrete beams. The truss system of concrete beam without concrete
on tension zone (BR) could develop almost same capacity to the
normal beam (BN). It can be observed also that specimens BR has
lower number of cracks than specimen BN. This may be caused by the
fact that there was no bonding effect on the tensile reinforcement on
specimen BR to distribute the cracks.
Abstract: The aim of this work is to use an environmental, cheap; organic non-traditional admixture to improve the structural behavior of sustainable reinforced concrete beams contains different ratios of recycled concrete aggregate. The used admixture prepared by using wastes from vegetable oil industry. Under and over reinforced concrete beams made from natural aggregate and different ratios of recycled concrete aggregate were tested under static load until failure. Eight beams were tested to investigate the performance and mechanism effect of admixture on improving deformation characteristics, modulus of elasticity and toughness of tested beams. Test results show efficiency of organic admixture on improving flexural behavior of beams contains 20% recycled concrete aggregate more over the other ratios.
Abstract: Many synthetic additives have been using for improve cement mortar and concrete characteristics, but natural additive is a friendly environment option. The quantity of (2% and 4%) seashell powder has been replaced in cement mortar, and compared with plain cement mortar in early age of 7 days. The strain gauges have been installed on beams and cube, for monitoring fluctuation of flexural and compressive strength. Main objective of this paper is to study effect of linear static force on flexural and compressive strength of modified cement mortar. The results have been indicated that the replacement of appropriate proportion of seashell powder enhances cement mortar mechanical properties. The replacement of 2% seashell causes improvement of deflection, time to failure and maximum load to failure on concrete beam and cube, the same occurs for compressive modulus elasticity. Increase replacement of seashell to 4% reduces all flexural strength, compressive strength and strain of cement mortar.
Abstract: The results of an experimental program conducted on seventeen simply supported concrete beams to study the effect of transverse reinforcement on the behavior of lap splice of steel reinforcement in tension zones in high strength concrete beams, are presented. The parameters included in the experimental program were the concrete compressive strength, the lap splice length, the amount of transverse reinforcement provided within the splice region, and the shape of transverse reinforcement around spliced bars. The experimental results showed that the displacement ductility increased and the mode of failure changed from splitting bond failure to flexural failure when the amount of transverse reinforcement in splice region increased, and the compressive strength increased up to 100 MPa. The presence of transverse reinforcement around spliced bars had pronounced effect on increasing the ultimate load, the ultimate deflection, and the displacement ductility. The prediction of maximum steel stresses for spliced bars using ACI 318-05 building code was compared with the experimental results. The comparison showed that the effect of transverse reinforcement around spliced bars has to be considered into the design equations for lap splice length in high strength concrete beams.
Abstract: The paper deals with current issues in research of advanced methods to increase reliability of traditional timber structural elements. It analyses the issue of strengthening of bent timber beams, such as ceiling beams in old (historical) buildings with additional concrete slab in combination with externally bonded fiber - reinforced polymer. The study evaluates deflection of a selected group of timber beams with concrete slab and additional CFRP reinforcement using different calculating methods and observes differences in results from different calculating methods. An elastic (EN 1995) calculation method and evaluation with FEM analysis software were used.
Abstract: Strut-and-Tie Models (STM) for the design of concrete beams, comprising of struts, ties, nodes as the basic tools, is conceptually simple, but its realization for complex concrete structure is not straightforward and depends on flow of internal forces in the structure. STM technique has won wide acceptance for deep member and shear design. STM technique is a unified approach that considers all load effects (bending, axial, shear, and torsion) simultaneously, not just applicable to shear loading only. The present study is to portray Strut-and-Tie Modeling based on Load-Transfer-Mechanisms as a unified method to analyze, design and detailing for deep and slender concrete beams. Three shear span- effective depth ratio (a/ d) are recommended for the modeling of STM elements corresponding to dominant load paths. The study also discusses the research work conduct on effective stress of concrete, tie end anchorage, and transverse reinforcement demand under different load transfer mechanism. It is also highlighted that to make the STM versatile tool for design of beams applicable to all shear spans, the effective stress of concrete and, transverse reinforcement demand, inclined angle of strut, and anchorage requirements of tie bars is required to be correlated with respect to load transfer mechanism. The country code provisions are to be modified and updated to apply for generalized design of concrete deep and slender member using load transfer mechanism based STM technique. Examples available in literature are reanalyzed with refined STM based on load transfer mechanisms and results are compared. It is concluded from the results that proposed approach will require true reinforcement demand depending on dominant force transfer action in concrete beam.
Abstract: The paper discusses the results obtained to predict
reinforcement in singly reinforced beam using Neural Net (NN),
Support Vector Machines (SVM-s) and Tree Based Models. Major
advantage of SVM-s over NN is of minimizing a bound on the
generalization error of model rather than minimizing a bound on
mean square error over the data set as done in NN. Tree Based
approach divides the problem into a small number of sub problems to
reach at a conclusion. Number of data was created for different
parameters of beam to calculate the reinforcement using limit state
method for creation of models and validation. The results from this
study suggest a remarkably good performance of tree based and
SVM-s models. Further, this study found that these two techniques
work well and even better than Neural Network methods. A
comparison of predicted values with actual values suggests a very
good correlation coefficient with all four techniques.
Abstract: This paper presents the Literature Review of carbon fiber reinforced polymer (CFRP) strips to reinforced concrete (RC) as a strengthening solution for T-beams. Although a great deal of research has been carried out on Rectangular beams strengthened with Fibre-Reinforced Polymer composites (FRP), Fiber reinforced polymer (FRP) composites have been increasingly studied for their application in the flexural or shear strengthening of reinforced concrete (RC) members. A detailed discussion of the shearstrengthening repair with FRP is undertaken. This paper will be limited to research of CFRP material externally bonded to the tensile face of concrete beams. In particular, research studying the effect of externally applied CFRP materials on the shear performance of reinforced concrete beams will be reported.