Abstract: The purpose of this study is to compare Self
Compacting Concrete (SCC) and Conventional Concrete (CC) in
terms of their capillary water absorption. During the comparison of
SCC and CC, the effects of two different factors were also
investigated: concrete strength class and curing condition. In the
study, both SCC and CC were produced in three different concrete
classes (C25, C50 and C70) and the other parameter (i.e. curing
condition) was determined as two levels: moisture and air curing. It
was observed that, for both curing environments and all strength
classes of concrete, SCCs had lower capillary water absorption values
than that of CCs. It was also detected that, for both SCC and CC,
capillary water absorption values of samples kept in moisture curing
were significantly lower than that of samples stored in air curing.
Additionally, it was determined that capillary water absorption values
for both SCC and CC decrease with increasing strength class of
concrete for both curing environments.
Abstract: At highly congested reinforcement regions, which is common at beam-column joint area, clear spacing between parallel bars becomes less than maximum normal aggregate size (20mm) which has not been addressed in any design code and specifications. Limited clear spacing between parallel bars (herein after thin cover) is one of the causes which affect anchorage performance. In this study, an experimental investigation was carried out to understand anchorage performance of reinforcement in Self-Compacting Concrete (SCC) and Normal Concrete (NC) at highly congested regions under uni-axial tensile loading. Column bar was pullout whereas; beam bars were offset from column reinforcement creating thin cover as per site condition. Two different sizes of coarse aggregate were used for NC (20mm and 10mm). Strain gauges were also installed along the bar in some specimens to understand the internal stress mechanism. Test results reveal that anchorage performance is affected at highly congested reinforcement region in NC with maximum aggregate size 20mm whereas; SCC and Small Aggregate (10mm) gives better structural performance.