Abstract: The cumulative conformance count (CCC) charts are
widespread in process monitoring of high-yield manufacturing.
Recently, it is found the use of variable sampling interval (VSI)
scheme could further enhance the efficiency of the standard CCC
charts. The average time to signal (ATS) a shift in defect rate has
become traditional measure of efficiency of a chart with the VSI
scheme. Determining the ATS is frequently a difficult and tedious
task. A simple method based on a finite Markov Chain approach for
modeling the ATS is developed. In addition, numerical results are
given.
Abstract: Three-phase induction machines are today a standard
for industrial electrical drives. Cost, reliability, robustness and maintenance free operation are among the reasons these machines are
replacing dc drive systems. The development of power electronics
and signal processing systems has eliminated one of the greatest
disadvantages of such ac systems, which is the issue of control. With
modern techniques of field oriented vector control, the task of
variable speed control of induction machines is no longer a
disadvantage. The need to increase system performance, particularly
when facing limits on the power ratings of power supplies and
semiconductors, motivates the use of phase number other than three,
In this paper a novel scheme of connecting two, three phase
induction motors in parallel fed by two inverters; viz. VSI and CSI
and their vector control is presented.
Abstract: This paper presents a comparison between two Pulse
Width Modulation (PWM) algorithms applied to a three-level Neutral
Point Clamped (NPC) Voltage Source Inverter (VSI). The first
algorithm applied is the triangular-sinusoidal strategy; the second is
the Space Vector Pulse Width Modulation (SVPWM) strategy. In the
first part, we present a topology of three-level NCP VSI. After that,
we develop the two PWM strategies to control this converter. At the
end the experimental results are presented.
Abstract: Active power filter continues to be a powerful tool to control harmonics in power systems thereby enhancing the power quality. This paper presents a fuzzy tuned PID controller based shunt active filter to diminish the harmonics caused by non linear loads like thyristor bridge rectifiers and imbalanced loads. Here Fuzzy controller provides the tuning of PID, based on firing of thyristor bridge rectifiers and variations in input rms current. The shunt APF system is implemented with three phase current controlled Voltage Source Inverter (VSI) and is connected at the point of common coupling for compensating the current harmonics by injecting equal but opposite filter currents. These controllers are capable of controlling dc-side capacitor voltage and estimating reference currents. Hysteresis Current Controller (HCC) is used to generate switching signals for the voltage source inverter. Simulation studies are carried out with non linear loads like thyristor bridge rectifier along with unbalanced loads and the results proved that the APF along with fuzzy tuned PID controller work flawlessly for different firing angles of non linear load.
Abstract: Direct Torque Control is a control technique in AC
drive systems to obtain high performance torque control. The
conventional DTC drive contains a pair of hysteresis comparators.
DTC drives utilizing hysteresis comparators suffer from high torque
ripple and variable switching frequency. The most common solution
to those problems is to use the space vector depends on the reference
torque and flux. In this Paper The space vector modulation technique
(SVPWM) is applied to 2 level inverter control in the proposed
DTC-based induction motor drive system, thereby dramatically
reducing the torque ripple. Then the controller based on space vector
modulation is designed to be applied in the control of Induction
Motor (IM) with a three-level Inverter. This type of Inverter has
several advantages over the standard two-level VSI, such as a greater
number of levels in the output voltage waveforms, Lower dV/dt, less
harmonic distortion in voltage and current waveforms and lower
switching frequencies. This paper proposes a general SVPWM
algorithm for three-level based on standard two-level SVPWM. The
proposed scheme is described clearly and simulation results are
reported to demonstrate its effectiveness. The entire control scheme is
implemented with Matlab/Simulink.
Abstract: Space Vector Modulation (SVM) is an optimum Pulse Width Modulation (PWM) technique for an inverter used in a variable frequency drive applications. It is computationally rigorous and hence limits the inverter switching frequency. Increase in switching frequency can be achieved using Neural Network (NN) based SVM, implemented on application specific chips. This paper proposes a neural network based SVM technique for a Voltage Source Inverter (VSI). The network proposed is independent of switching frequency. Different architectures are investigated keeping the total number of neurons constant. The performance of the inverter is compared for various switching frequencies for different architectures of NN based SVM. From the results obtained, the network with minimum resource and appropriate word length is identified. The bit precision required for this application is identified. The network with 8-bit precision is implemented in the IC XCV 400 and the results are presented. The performance of NN based general purpose SVM with higher bit precision is discussed.
Abstract: Most high-performance ac drives utilize a current
controller. The controller switches a voltage source inverter (VSI)
such that the motor current follows a set of reference current
waveforms. Fixed-band hysteresis (FBH) current control has been
widely used for the PWM inverter. We want to apply the same
controller for the PWM AC chopper. The aims of the controller is to
optimize the harmonic content at both input and output sides, while
maintaining acceptable losses in the ac chopper and to control in
wide range the fundamental output voltage. Fixed band controller has
been simulated and analyzed for a single-phase AC chopper and are
easily extended to three-phase systems. Simulation confirmed the
advantages and the excellent performance of the modulation method
applied for the AC chopper.
Abstract: This paper discusses two observers, which are used
for the estimation of parameters of PMSM. Former one, reduced
order observer, which is used to estimate the inaccessible parameters
of PMSM. Later one, full order observer, which is used to estimate
all the parameters of PMSM even though some of the parameters are
directly available for measurement, so as to meet with the
insensitivity to the parameter variation. However, the state space
model contains some nonlinear terms i.e. the product of different
state variables. The asymptotic state observer, which approximately
reconstructs the state vector for linear systems without uncertainties,
was presented by Luenberger. In this work, a modified form of such
an observer is used by including a non-linear term involving the
speed. So, both the observers are designed in the framework of
nonlinear control; their stability and rate of convergence is discussed.
Abstract: Voltage flicker is a disturbance in electrical power
systems. The reason for this disturbance is mainly the large nonlinear
loads such as electric arc furnaces. Synchronous static
compensator (STATCOM) is considered as a proper technique to
mitigate the voltage flicker. Application of more suitable and precise
power electronic converter leads to a more precise performance of the
compensator. In this paper a three-level 12-pulse voltage source
inverter (VSI) with a 12-terminal transformer connected to the ac
system is studied and the obtained results are compared with the
performance of a STATCOM using a simple two-level VSI and an
optimal and more precise performance of the proposed scheme is
achieved.
Abstract: This paper presents the mathematical model and
control strategy on DQ frame of shunt active power filter. The
structure of the shunt active power filter is the voltage source inverter
(VSI). The pulse width modulation (PWM) with PI controller is used
in the paper. The concept of DQ frame to apply with the shunt active
power filter is described. Moreover, the detail of the PI controller
design for two current loops and one voltage loop are fully explained.
The DQ axis with Fourier (DQF) method is applied to calculate the
reference currents on DQ frame. The simulation results show that the
control strategy and the design method presented in the paper can
provide the good performance of the shunt active power filter.
Moreover, the %THD of the source currents after compensation can
follow the IEEE Std.519-1992.
Abstract: This paper proposes a three-phase four-wire currentcontrolled
Voltage Source Inverter (CC-VSI) for both power quality
improvement and PV energy extraction. For power quality
improvement, the CC-VSI works as a grid current-controlling shunt
active power filter to compensate for harmonic and reactive power of
loads. Then, the PV array is coupled to the DC bus of the CC-VSI
and supplies active power to the grid. The MPPT controller employs
the particle swarm optimization technique. The output of the MPPT
controller is a DC voltage that determines the DC-bus voltage
according to PV maximum power. The PSO method is simple and
effective especially for a partially shaded PV array. From computer
simulation results, it proves that grid currents are sinusoidal and inphase
with grid voltages, while the PV maximum active power is
delivered to loads.
Abstract: This paper present a MATLAB-SIMULINK model of a single phase 2.5 KVA, 240V RMS controlled PV VSI (Photovoltaic Voltage Source Inverter) inverter using IGBTs (Insulated Gate Bipolar Transistor). The behavior of output voltage, output current, and the total harmonic distortion (THD), with the variation in input dc blocking capacitor (Cdc), for linear and non-linear load has been analyzed. The values of Cdc as suggested by the other authors in their papers are not clearly defined and it poses difficulty in selecting the proper value. As the dc power stored in Cdc, (generally placed parallel with battery) is used as input to the VSI inverter. The simulation results shows the variation in the output voltage and current with different values of Cdc for linear and non-linear load connected at the output side of PV VSI inverter and suggest the selection of suitable value of Cdc.
Abstract: This paper presents a novel control strategy of a threephase
four-wire Unified Power Quality (UPQC) for an improvement
in power quality. The UPQC is realized by integration of series and
shunt active power filters (APFs) sharing a common dc bus capacitor.
The shunt APF is realized using a thee-phase, four leg voltage source
inverter (VSI) and the series APF is realized using a three-phase,
three leg VSI. A control technique based on unit vector template
technique (UTT) is used to get the reference signals for series APF,
while instantaneous sequence component theory (ISCT) is used for
the control of Shunt APF. The performance of the implemented
control algorithm is evaluated in terms of power-factor correction,
load balancing, neutral source current mitigation and mitigation of
voltage and current harmonics, voltage sag and swell in a three-phase
four-wire distribution system for different combination of linear and
non-linear loads. In this proposed control scheme of UPQC, the
current/voltage control is applied over the fundamental supply
currents/voltages instead of fast changing APFs currents/voltages,
there by reducing the computational delay and the required sensors.
MATLAB/Simulink based simulations are obtained, which support
the functionality of the UPQC. MATLAB/Simulink based
simulations are obtained, which support the functionality of the
UPQC.