Abstract: Passive design responds to improve indoor thermal comfort and minimize the energy consumption. The present research analyzed the how efficiently passive solar technologies generate heating and cooling and provide the system integration for domestic applications. In addition to this, the aim of this study is to increase the efficiency of solar systems system with integration some innovation and optimization. As a result, outputs of the project might start a new sector to provide environmentally friendly and cheap cooling for domestic use.
Abstract: In this paper, an attempt has been made to analyze the effect of wall window orientation on Daylight Illuminance Ratio (DIR) and energy saving in a building known as “SODHA BERS COMPLEX (SBC)” at Varanasi, UP, India. The building has been designed incorporating all passive concepts for thermal comfort as well daylighting concepts to maximize the use of natural daylighting for the occupants in the day to day activities. The annual average DIR and the energy saving has been estimated by using the DIR model for wall window with different orientations under clear sky condition. It has been found that for south oriented window the energy saving per square meter is more compared to the other orientations due to the higher level of solar insolation for the south window in northern hemisphere whereas energy saving potential is minimum for north oriented wall window. The energy saving potential was 26%, 81% and 51% higher for east, south and west oriented window in comparison to north oriented window. The average annual DIR has same trends of variation as the annual energy saving and it is maximum for south oriented window and minimum for north oriented window.
Abstract: With 40% of total world energy consumption,
building systems are developing into technically complex large
energy consumers suitable for application of sophisticated power
management approaches to largely increase the energy efficiency
and even make them active energy market participants. Centralized
control system of building heating and cooling managed by
economically-optimal model predictive control shows promising
results with estimated 30% of energy efficiency increase. The research
is focused on implementation of such a method on a case study
performed on two floors of our faculty building with corresponding
sensors wireless data acquisition, remote heating/cooling units and
central climate controller. Building walls are mathematically modeled
with corresponding material types, surface shapes and sizes. Models
are then exploited to predict thermal characteristics and changes in
different building zones. Exterior influences such as environmental
conditions and weather forecast, people behavior and comfort
demands are all taken into account for deriving price-optimal climate
control. Finally, a DC microgrid with photovoltaics, wind turbine,
supercapacitor, batteries and fuel cell stacks is added to make the
building a unit capable of active participation in a price-varying
energy market. Computational burden of applying model predictive
control on such a complex system is relaxed through a hierarchical
decomposition of the microgrid and climate control, where the
former is designed as higher hierarchical level with pre-calculated
price-optimal power flows control, and latter is designed as lower
level control responsible to ensure thermal comfort and exploit
the optimal supply conditions enabled by microgrid energy flows
management. Such an approach is expected to enable the inclusion
of more complex building subsystems into consideration in order to
further increase the energy efficiency.
Abstract: An analysis of the air tightness level is performed on a representative sample of school classrooms in Southern Spain, which allows knowing the infiltration level of these classrooms, mainly through its envelope, which can affect both energy demand and occupant's thermal comfort. By using a pressurization/depressurization equipment (Blower-Door test), a characterization of 45 multipurpose classrooms have been performed in nine non-university educational institutions of the main climate zones of Southern Spain. In spite of having two doors and a high ratio between glass surface and outer surface, it is possible to see in these classrooms that there is an adequate level of airtightness, since all the n50 values obtained are lower than 9.0 ACH, with an average value around 7.0 ACH.
Abstract: In this paper, the energy saving and human thermal
comfort in a typical office room are investigated. The impact of a
combined system of exhaust inlet air with light slots located at the
ceiling level in a room served by displacement ventilation system is
numerically modelled. Previous experimental data are used to
validate the Computational Fluid Dynamic (CFD) model. A case
study of simulated office room includes two seating occupants, two
computers, two data loggers and four lamps. The combined system is
located at the ceiling level above the heat sources. A new method of
calculation for the cooling coil load in Stratified Air Distribution
(STRAD) system is used in this study. The results show that 47.4%
energy saving of space cooling load can be achieved by combing the
exhaust inlet air with light slots at the ceiling level above the heat
sources.
Abstract: Based on an indoor environmental quality (IEQ) index established by previous work that indicates the overall IEQ acceptance from the prospect of an occupant in residential buildings in terms of four IEQ factors - thermal comfort, indoor air quality, visual and aural comforts, this study develops a user-friendly IEQ calculator for iOS and Android users to calculate the occupant acceptance and compare the relative performance of IEQ in apartments. “IEQ calculator” is easy to use and it preliminarily illustrates the overall indoor environmental quality on the spot. Users simply input indoor parameters such as temperature, number of people and windows are opened or closed for the mobile application to calculate the scores in four areas: the comforts of temperature, brightness, noise and indoor air quality. The calculator allows the prediction of the best IEQ scenario on a quantitative scale. Any indoor environments under the specific IEQ conditions can be benchmarked against the predicted IEQ acceptance range. This calculator can also suggest how to achieve the best IEQ acceptance among a group of residents.
Abstract: The objective of this study is to conduct computational
fluid dynamic (CFD) simulations for evaluating the cooling efficacy
from vegetation implanted in a public park in the Taipei, Taiwan. To
probe the impacts of park renewal by means of adding three pavilions
and supplementary green areas on urban microclimates, the simulated
results have revealed that the park having a higher percentage of green
coverage ratio (GCR) tended to experience a better cooling effect.
These findings can be used to explore the effects of different greening
modifications on urban environments for achieving an effective
thermal comfort in urban public spaces.
Abstract: Part and parcel of building green homes (GHs) with
favorable thermal comfort (TC) is to design and build with reduced
carbon footprint (CF) from embodied energy in the building envelope
and reduced operational CF overall. Together, the environmental
impact of GHs can be reduced significantly. Nevertheless, there is
still a need to identify the base CF value for Malaysian GHs and this
can be done by assessing existing ones which can then be compared
to conventional and vernacular houses which are built differently
with different building materials. This paper underlines the research
design and introduces the case studies. For now, the operational CF
of the case studies is beyond the scope of this study. Findings from
this research could identify the best building material and
construction technique combination to build GHs depending on the
available skills, financial constraints and the condition of the
immediate environment.
Abstract: This paper presents an adaptive thermal comfort
model study in the tropical country of Malaysia. A number of
researchers have been interested in applying the adaptive thermal
comfort model to different climates throughout the world, but so far
no study has been performed in Malaysia. For the use as a thermal
comfort model, which better applies to hot and humid climates, the
adaptive thermal comfort model was developed as part of this
research by using the collected results from a large field study in six
lecture halls with 178 students. The relationship between the
operative temperature and behavioral adaptations was determined. In
the developed adaptive model, the acceptable indoor neutral
temperatures lay within the range of 23.9-26.0C, with outdoor
temperatures ranging between 27.0-34.6C. The most comfortable
temperature for students in lecture hall was 25.7C.
Abstract: Auckland has a temperate climate with comfortable warm, dry summers and mild, wet winters. An Auckland school normally does not need air conditioning for cooling during the summer and only needs heating during the winter. The Auckland school building thermal design should more focus on winter thermal performance and indoor thermal comfort for energy efficiency. This field study of testing indoor and outdoor air temperatures, relative humidity and indoor surface temperatures of three classrooms with different envelopes were carried out in the Avondale College during the winter months in 2013. According to the field study data, this study is to compare and evaluate winter thermal performance and indoor thermal conditions of school buildings with different envelopes.
Abstract: Sustainable tall buildings that provide comfortable,
healthy and efficient indoor environments are clearly desirable as the
densification of living and working space for the world’s increasing
population proceeds. For environmental concerns, these buildings
must also be energy efficient. One component of these tasks is the
provision of indoor air quality and thermal comfort, which can be
enhanced with natural ventilation by the supply of fresh air. Working
spaces can only be naturally ventilated with connections to the
outdoors utilizing operable windows, double facades, ventilation
stacks, balconies, patios, terraces and skygardens. Large amounts of
fresh air can be provided to the indoor spaces without mechanical
air-conditioning systems, which are widely employed in
contemporary tall buildings.
This paper tends to present the concept of natural ventilation for
sustainable tall office buildings in order to achieve healthy and
comfortable working spaces, as well as energy efficient
environments. Initially the historical evolution of ventilation
strategies for tall buildings is presented, beginning with natural
ventilation and continuing with the introduction of mechanical airconditioning
systems. Then the emergence of natural ventilation due
to the health and environmental concerns in tall buildings is handled,
and the strategies for implementing this strategy are revealed. In the
next section, a number of case studies that utilize this strategy are
investigated. Finally, how tall office buildings can benefit from this
strategy is discussed.
Abstract: In order to respond the human needs, all regional, social, and economical factors are available to gain residents’ comfort and ideal architecture. There is no doubt the thermal comfort has to satisfy people not only for daily and physical activities but also creating pleasant area for mental activities and relaxing. It costs energy and increases greenhouse gas emissions.
Reducing energy use in buildings is a critical component of meeting carbon reduction commitments. Hence housing design represents a major opportunity to cut energy use and CO2 emissions.
In terms of energy efficiency, it is vital to propose and research modern design methods for buildings however vernacular architecture techniques are proven empirical existing practices which have to be considered. This research tries to compare two architectural solution were proposed by Persian vernacular architecture, to achieve energy efficiency in hot areas.
The aim of this research is to analyze two forms of traditional Persian architecture in different locations in order to develop a systematic research and sustainable technologies on adaptation to contemporary living standards.
Abstract: A one-dimensional mathematical model was developed in order to analyze and optimize the latent heat storage wall. The governing equations for energy transport were developed by using the enthalpy method and discretized with volume control scheme. The resulting algebraic equations were next solved iteratively by using TDMA algorithm. A series of numerical investigations were conducted in order to examine the effects of the thickness of the PCM layer on the thermal behavior of the proposed heating system. Results are obtained for thermal gain and temperature fluctuation. The charging discharging process was also presented and analyzed.
Abstract: The concern with sustainability brought the need for optimization of the buildings to reduce consumption of natural resources. Almost 1/3 of energy demanded by Brazilian housings is used to provide thermal solutions. AEC sector may contribute applying bioclimatic strategies on building design. The aim of this research is to investigate the viability of applying some alternative solutions in residential buildings. The research was developed with computational simulation on single family social housing, examining envelope type, absorptance, and insolation. The analysis of the thermal performance applied both Brazilian standard NBR 15575 and degree-hour method, in the scenery of Porto Alegre, a southern Brazilian city. We used BIM modeling through Revit/Autodesk and used Energy Plus to thermal simulation. The payback of the investment was calculated comparing energy savings and building costs, in a period of 50 years. The results shown that with the increment of envelope’s insulation there is thermal comfort improvement and energy economy, with a pay-back period of 24 to 36 years, in some cases.
Abstract: Climate considerations are essential dimensions in the assessment of thermal comfort and indoor environments inside Egyptian housing. The primary aim of this paper is to analyze the indoor environment of new housing in the new city of Assiut in the Southern Upper Egypt zone, in order to evaluate its thermal environment and determine the acceptable indoor operative temperatures. The psychrometric charts for ASHRAE Standard 55 and ACS used in this study would facilitate an overall representation of the climate in one of the hottest months in the summer season. This study helps to understand and deal with this problem and work on a passive cooling ventilation strategy in these contexts in future studies. The results that demonstrated the indoor temperature is too high, ranges between 31°C to 40°C in different natural ventilation strategies. This causes the indoor environment to be far from the optimum comfort operative temperature of ACS except when using air conditioners. Finally, this study is considered a base for developing a new system using natural ventilation with passive cooling strategies.
Abstract: Displacement ventilation of a room with an occupant is modeled using CFD. The geometry of manikin is accurately represented in CFD model to minimize potential. Indoor zero equation turbulence model is used to simulate all cases and the effect of the thermal radiation from manikin is taken into account. After validation of the code, predicted mean vote, mean age of air, and ventilation effectiveness are used to predict the thermal comfort zones and indoor air quality. The effect of the inlet velocity and temperature on the thermal comfort and indoor air quality is investigated. The results show that the inlet velocity has great effect on the thermal comfort and indoor air quality and low inlet velocity is sufficient to establish comfortable conditions inside the room. In addition, the displacement ventilation system achieves not only thermal comfort in ventilated rooms, but also energy saving of fan power.
Abstract: Understanding the behavior of airflow in a room is essential for building designers to provide the most efficient design of ventilation system, and having acceptable indoor air quality. This trend is the motive to solve the relationship between airflow parameters and thermal comfort. This paper investigates airflow characteristics, indoor air quality (IAQ), and the thermal comfort (TC) in a ventilated room with a displacement ventilation system using three dimensional CFD code [AirPak 2.0.6]. After validation of the code, a numerical study is executed for a typical room with dimensions of 5m by 3m by 3m height according to a variety of supply air velocities, supply air temperature and supply air relative humidity. The finite volume method and the indoor zero equation turbulence models are employed for solving the governing equations numerically. The temperature field and the mean age of air (MAA) in the modeled room for a displacement ventilation system are determined according to a variety of the above parameters. The variable air volume (VAV) systems with different supply air velocity are applicable to control room air temperature for a displacement ventilation system.
Abstract: This study examines the stack ventilation performance of an office building located in Taipei, Taiwan. Atriums in this building act as stacks that facilitate buoyancy-driven ventilation. Computational Fluid Dynamic (CFD) simulations are used to identify interior airflow patterns, and then used these patterns to assess the building’s heat expulsion efficiency. Ambient temperatures of 20°C were adopted as the typical seasonal spring temperature range in Taipei. Further, “zero-wind” conditions are established to ensure simulation results reflected only the buoyancy effect. After checking results against neutral pressure level (NPL) level, airflow, air velocity, and indoor temperature stratification, the lower stack is modified to reduce the NPL in order to remove heat accumulated on the top floor.
Abstract: The objective of this study is to present the test
results of variable air volume (VAV) air conditioning system
optimized by two objective genetic algorithm (GA). The objective
functions are energy savings and thermal comfort. The optimal set
points for fuzzy logic controller (FLC) are the supply air temperature
(Ts), the supply duct static pressure (Ps), the chilled water
temperature (Tw), and zone temperature (Tz) that is taken as the
problem variables. Supply airflow rate and chilled water flow rate are
considered to be the constraints. The optimal set point values are
obtained from GA process and assigned into fuzzy logic controller
(FLC) in order to conserve energy and maintain thermal comfort in
real time VAV air conditioning system. A VAV air conditioning
system with FLC installed in a software laboratory has been taken for
the purpose of energy analysis. The total energy saving obtained in
VAV GA optimization system with FLC compared with constant air
volume (CAV) system is expected to achieve 31.5%. The optimal
duct static pressure obtained through Genetic fuzzy methodology
attributes to better air distribution by delivering the optimal quantity
of supply air to the conditioned space. This combination enhanced
the advantages of uniform air distribution, thermal comfort and
improved energy savings potential.
Abstract: So much energy is used in high rise buildings to fulfill
the basic needs of users such as lighting and thermal comfort.
Malaysia has hot and humid climate, buildings especially high rise
buildings receive unnecessary solar radiation that cause more solar
heat gain. Energy use specially electricity consumption in high rise
buildings has increased. There have been growing concerns about
energy consumption and its effect on environment. Building, energy
and the environment are important issues that the designers should
consider to them. Self protected form is one of possible ways against
the impact of solar radiation in high rise buildings. The Energy
performance of building envelopes was investigated in term of the
Overall Thermal Transfer Value (OTTV ).In this paper, the amount
of OTTV reduction was calculated through OTTV Equations to
clear the effectiveness of self shading strategy on minimizing energy
consumption for cooling interior spaces in high rise buildings which
has considerable envelope areas against solar radiation. Also increasing
the optimum window area was investigated using self-shading
strategy in designing high rise buildings. As result, the significant
reduction in OTTV was shown based on WWR.In addition slight
increase was demonstrated in WWR that can influence on visible
comfort interior spaces.