Abstract: Both steady and unsteady turbulent mixed convection
heat transfer in a 3D lid-driven enclosure, which has constant heat
flux on the middle of bottom wall and with isothermal moving
sidewalls, is reported in this paper for working fluid with Prandtl
number Pr = 0.71. The other walls are adiabatic and stationary. The
dimensionless parameters used in this research are Reynolds number,
Re = 5000, 10000 and 15000, and Richardson number, Ri = 1 and 10.
The simulations have been done by using different turbulent methods
such as RANS, URANS, and LES. The effects of using different k-ε
models such as standard, RNG and Realizable k-ε model are
investigated. Interesting behaviours of the thermal and flow fields
with changing the Re or Ri numbers are observed. Isotherm and
turbulent kinetic energy distributions and variation of local Nusselt
number at the hot bottom wall are studied as well. The local Nusselt
number is found increasing with increasing either Re or Ri number.
In addition, the turbulent kinetic energy is discernibly affected by
increasing Re number. Moreover, the LES results have shown good
ability of this method in predicting more detailed flow structures in
the cavity.
Abstract: In this paper, the energy saving and human thermal
comfort in a typical office room are investigated. The impact of a
combined system of exhaust inlet air with light slots located at the
ceiling level in a room served by displacement ventilation system is
numerically modelled. Previous experimental data are used to
validate the Computational Fluid Dynamic (CFD) model. A case
study of simulated office room includes two seating occupants, two
computers, two data loggers and four lamps. The combined system is
located at the ceiling level above the heat sources. A new method of
calculation for the cooling coil load in Stratified Air Distribution
(STRAD) system is used in this study. The results show that 47.4%
energy saving of space cooling load can be achieved by combing the
exhaust inlet air with light slots at the ceiling level above the heat
sources.
Abstract: In this study, a computational fluid dynamics (CFD)
model has been developed for studying the effect of surface
roughness profile on the EHL problem. The cylinders contact
geometry, meshing and calculation of the conservation of mass and
momentum equations are carried out using the commercial software
packages ICEMCFD and ANSYS Fluent. The user defined functions
(UDFs) for density, viscosity and elastic deformation of the cylinders
as the functions of pressure and temperature are defined for the CFD
model. Three different surface roughness profiles are created and
incorporated into the CFD model. It is found that the developed CFD
model can predict the characteristics of fluid flow and heat transfer in
the EHL problem, including the main parameters such as pressure
distribution, minimal film thickness, viscosity, and density changes.
The results obtained show that the pressure profile at the center of the
contact area directly relates to the roughness amplitude. A rough
surface with kurtosis value of more than 3 has greater influence over
the fluctuated shape of pressure distribution than in other cases.
Abstract: Using a scoring system, this paper provides a
comparative assessment of the quality of data between XBRL
formatted financial reports and non-XBRL financial reports. It shows a
major improvement in the quality of data of XBRL formatted financial
reports. Although XBRL formatted financial reports do not show
much advantage in the quality at the beginning, XBRL financial
reports lately display a large improvement in the quality of data in
almost all aspects. With the improved XBRL web data managing,
presentation and analysis applications, XBRL formatted financial
reports have a much better accessibility, are more accurate and better
in timeliness.