Abstract: The synthesis of CuFe2O4 spinel powders by an
optimized combustion-like process followed by calcination is
described herein. The samples were characterized using X-ray
diffraction (XRD), differential thermal analysis (TG/DTA), scanning
electron microscopy (SEM), dilatometry and 4-probe DC methods.
Different glycine to nitrate (G/N) ratios of 1 (fuel-deficient), 1.48
(stoichiometric) and 2 (fuel-rich) were employed. Calcining the asprepared
powders at 800 and 1000°C for 5 hours showed that the G/N
ratio of 2 results in the formation of the desired copper spinel single
phase at both calcination temperatures. For G/N=1, formation of
CuFe2O4 takes place in three steps. First, iron and copper nitrates
decompose to iron oxide and pure copper. Then, copper transforms to
copper oxide and finally, copper and iron oxides react with each other
to form a copper ferrite spinel phase. The electrical conductivity and
the coefficient of thermal expansion of the sintered pelletized
samples were 2 S.cm-1 (800°C) and 11×10-6 °C-1 (25-800°C),
respectively.
Abstract: In recent research copper and manganese systems
were found to be the most active in CO and organic compounds
oxidation among the base catalysts. The mixed copper manganese
oxide has been widely studied in oxidation reactions because of their
higher activity at low temperatures in comparison with single oxide
catalysts. The results showed that the formation of spinel
CuxMn3−xO4 in the oxidized catalyst is responsible for the activity
even at room temperature. That is why the most of the investigations
are focused on the hopcalite catalyst (CuMn2O4) as the best coppermanganese
catalyst. Now it’s known that this is true only for CO
oxidation, but not for mixture of CO and VOCs. The purpose of this
study is to investigate the alumina supported copper-manganese
catalysts with different Cu/Mn molar ratio in terms of oxidation of
CO, methanol and dimethyl ether. The catalysts were prepared by impregnation of γ-Al2O3 with
copper and manganese nitrates and the catalytic activity
measurements were carried out in two stage continuous flow
equipment with an adiabatic reactor for simultaneous oxidation of all
compounds under the conditions closest possible to the industrial. Gas
mixtures on the input and output of the reactor were analyzed with a
gas chromatograph, equipped with FID and TCD detectors. The
texture characteristics were determined by low-temperature (- 196oС)
nitrogen adsorption in a Quantachrome Instruments NOVA 1200e
(USA) specific surface area & pore analyzer. Thermal, XRD and
TPR analyses were performed. It was established that the active component of the mixed Cu-
Mn/γ–alumina catalysts strongly depends on the Cu/Mn molar ratio.
Highly active alumina supported Cu-Mn catalysts for CO, methanol
and DME oxidation were synthesized. While the hopcalite is the best
catalyst for CO oxidation, the best compromise for simultaneous
oxidation of all components is the catalyst with Cu/Mn molar ratio
1:5.
Abstract: Obesity and osteoporosis are the two diseases whose
increasing prevalence and high impact on the global morbidity and
mortality, during the two recent decades, have gained a status of
major health threats worldwide. Obesity purports to affect the bone
metabolism through complex mechanisms. Debated data on the
connection between the bone mineral density and fracture prevalence
in the obese patients are widely presented in literature. There is
evidence that the correlation of weight and fracture risk is sitespecific.
This study is aimed at determining the connection between
the bone mineral density (BMD) and trabecular bone score (TBS)
parameters in Ukrainian women suffering from obesity. We
examined 1025 40-89-year-old women, divided them into the groups
according to their body mass index: Group A included 360 women
with obesity whose BMI was ≥30 kg/m2, and Group B – 665 women
with no obesity and BMI of
Abstract: It is well known that in recent years magnetic
materials have received increased attention due to their properties.
For this reason a significant number of patents that were published
during the last decade are oriented towards synthesis and study of
such materials. The aim of this work is to create and study ferrite
nanocrystalline materials with spinel structure, using sol-gel
technology with participation of auto-combustion. This method is
perspective in that it is a cheap and low-temperature technique that
allows for the fine control on the product’s chemical composition.
Abstract: The pullout strength had an effect on the stability of
plate screw fixation when inserted in the cervical spine. Nine
different titanium alloy bone screws were used to test the pullout
strength through finite element analysis. The result showed that the
Moss Miami I can bear the highest pullout force at 1,075 N, which
causes the maximum von Mises stress at 858.87 MPa, a value over
the yield strength of titanium. The bone screw should have large
outer diameter, core diameter and proximal root radius to increase the
pullout strength.
Abstract: The aim of this study is to develop an anterior lumbar
interbody fusion (ALIF) PEEK cage suitable for Korean people. In this
study, CT images were obtained from Korean male (173cm, 71kg) and
3D Korean lumbar models were reconstructed based on the CT images
to investigate anatomical characteristics. Major design parameters of
anterior lumbar interbody fusion (ALIF) PEEK Cage were selected
using the morphological measurement information of the Korean
Lumbar models. Through finite element analysis and mechanical tests,
the developed ALIFPEEK Cage prototype was compared with the
Fidji Cage (Zimmer. Inc, USA) and it was found that the ALIF
prototype showed similar and/or superior mechanical performance
compared to the FidJi Cage. Also, clinical validation for the ALIF
PEEK Cage prototype was carried out to check predictable troubles in
surgical operations. Finally, it is considered that the convenience and
stability of the prototype was clinically verified.
Abstract: A novel hybrid model of the lumbar spine, allowing
fast static and dynamic simulations of the disc pressure
and the spine mobility, is introduced in this work. Our
contribution is to combine rigid bodies, deformable finite
elements, articular constraints, and springs into a unique model
of the spine. Each vertebra is represented by a rigid body
controlling a surface mesh to model contacts on the facet
joints and the spinous process. The discs are modeled using
a heterogeneous tetrahedral finite element model. The facet
joints are represented as elastic joints with six degrees of
freedom, while the ligaments are modeled using non-linear
one-dimensional elastic elements. The challenge we tackle
is to make these different models efficiently interact while
respecting the principles of Anatomy and Mechanics.
The mobility, the intradiscal pressure, the facet joint force and
the instantaneous center of rotation of the lumbar spine are
validated against the experimental and theoretical results of
the literature on flexion, extension, lateral bending as well as
axial rotation.
Our hybrid model greatly simplifies the modeling task and
dramatically accelerates the simulation of pressure within the
discs, as well as the evaluation of the range of motion and the
instantaneous centers of rotation, without penalizing precision.
These results suggest that for some types of biomechanical
simulations, simplified models allow far easier modeling and
faster simulations compared to usual full-FEM approaches
without any loss of accuracy.
Abstract: This article presents summary on preparation and
characterization of zinc, copper, cadmium and cobalt chromite
nanocrystals, embedded in an amorphous silica matrix. The
ZnCr2O4/SiO2, CuCr2O4/SiO2, CdCr2O4/SiO2 and CoCr2O4/SiO2
nanocomposites were prepared by a conventional sol-gel method
under acid catalysis. Final heat treatment of the samples was carried
out at temperatures in the range of 900−1200 ◦C to adjust the
phase composition and the crystallite size, respectively. The resulting
samples were characterized by Powder X-ray diffraction (PXRD),
High Resolution Transmission Electron Microscopy (HRTEM),
Raman/FTIR spectroscopy and magnetic measurements. Formation
of the spinel phase was confirmed in all samples. The average size of
the nanocrystals was determined from the PXRD data and by direct
particle size observation on HRTEM; both results were correlated.
The mean particle size (reviewed by HRTEM) was in the range from
∼4 to 46 nm. The results showed that the sol-gel method can be
effectively used for preparation of the spinel chromite nanoparticles
embedded in the silica matrix and the particle size is driven by the
type of the cation A2+ in the spinel structure and the temperature
of the final heat treatment. Magnetic properties of the nanocrystals
were found to be just moderately modified in comparison to the bulk
phases.
Abstract: Nowadays spinal deformities are very frequent
problems among teenagers. Scheuermann disease is a one
dimensional deformity of the spine, but it has prevalence over 11% of
the children. A traditional technology, the moiré method was used by
us for screening and diagnosing this type of spinal deformity. A
LabVIEW program has been developed to evaluate the moiré pictures
of patients with Scheuermann disease. Two different solutions were
tested in this computer program, the extreme and the inflexion point
calculation methods. Effects using these methods were compared and
according to the results both solutions seemed to be appropriate.
Statistical results showed better efficiency in case of the extreme
search method where the average difference was only 6,09⁰.
Abstract: It is known that a left C-wrpp semigroup can
be described as curler structure of a left band and a C-wrpp
semigroup. In this paper, we introduce the class of weakly left
C-wrpp semigroups which includes the class of weakly left C-rpp
semigroups as a subclass. We shall particularly show that the spined
product of a left C-wrpp semigroup and a right normal band is a
weakly left C-wrpp semifroup. Some equivalent characterizations of
weakly left C-wrpp semigroups are obtained. Our results extend that
of left C-wrpp semigroups.
Abstract: This study was designed for assessment of 3 types of Cysteine protease inhibitors (CPIs) fluromethylketone (FMK), vinyl sulfone (VS) and sodium nitro prussid (SNP), to define which of them is the best for curing S. mansoni infection in mice? In vitro, treated S. mansoni adult worms recorded a mortality rate after 1 hr of exposure to 500 ppm of FMK, VS and SNP as 75, 70 and 60%, respectively. FMK+PZQ treatment recorded the maximum reduction in worm burden (97.2% at 5 wk PI). VS treatment alone or combined with PZQ increases IgM, total IgG, IgG2 and IgG4 levels. In EM study, the completely implanted spines were reported in the degenerated tegument of adult worms in all groups treated with CPIs. VS+PZQ Treatment increased Igs levels but, its effect was different on worm reduction. So, it is not enough to eliminate the infection and FMK+PZQ considered the antischistosomicidal drug of choice.
Abstract: Medical image modalities such as computed
tomography (CT), magnetic resonance imaging (MRI), ultrasound
(US), X-ray are adapted to diagnose disease. These modalities
provide flexible means of reviewing anatomical cross-sections and
physiological state in different parts of the human body. The raw
medical images have a huge file size and need large storage
requirements. So it should be such a way to reduce the size of those
image files to be valid for telemedicine applications. Thus the image
compression is a key factor to reduce the bit rate for transmission or
storage while maintaining an acceptable reproduction quality, but it is
natural to rise the question of how much an image can be compressed
and still preserve sufficient information for a given clinical
application. Many techniques for achieving data compression have
been introduced. In this study, three different MRI modalities which
are Brain, Spine and Knee have been compressed and reconstructed
using wavelet transform. Subjective and objective evaluation has
been done to investigate the clinical information quality of the
compressed images. For the objective evaluation, the results show
that the PSNR which indicates the quality of the reconstructed image
is ranging from (21.95 dB to 30.80 dB, 27.25 dB to 35.75 dB, and
26.93 dB to 34.93 dB) for Brain, Spine, and Knee respectively. For
the subjective evaluation test, the results show that the compression
ratio of 40:1 was acceptable for brain image, whereas for spine and
knee images 50:1 was acceptable.
Abstract: In this paper, the construction of a detailed spine
model is presented using the LifeMOD Biomechanics Modeler. The
detailed spine model is obtained by refining spine segments in
cervical, thoracic and lumbar regions into individual vertebra
segments, using bushing elements representing the intervertebral
discs, and building various ligamentous soft tissues between
vertebrae. In the sagittal plane of the spine, constant force will be
applied from the posterior to anterior during simulation to determine
dynamic characteristics of the spine. The force magnitude is
gradually increased in subsequent simulations. Based on these
recorded dynamic properties, graphs of displacement-force
relationships will be established in terms of polynomial functions by
using the least-squares method and imported into a haptic integrated
graphic environment. A thoracolumbar spine model with complex
geometry of vertebrae, which is digitized from a resin spine
prototype, will be utilized in this environment. By using the haptic
technique, surgeons can touch as well as apply forces to the spine
model through haptic devices to observe the locomotion of the spine
which is computed from the displacement-force relationship graphs.
This current study provides a preliminary picture of our ongoing
work towards building and simulating bio-fidelity scoliotic spine
models in a haptic integrated graphic environment whose dynamic
properties are obtained from LifeMOD. These models can be helpful
for surgeons to examine kinematic behaviors of scoliotic spines and
to propose possible surgical plans before spine correction operations.
Abstract: In this paper, the class of weakly left C-wrpp
semigroups which includes the class of weakly left C-rpp semigroups
as a subclass is introduced. To particularly show that the spined
product of a left C-wrpp semigroup and a right normal band which is a
weakly left C-wrpp semifroup by virtue of left C-full Ehremann cyber
groups recently obtained by authors Li-Shum, results obtained by
Tang and Du-Shum are extended and strengthened.
Abstract: Hysitron TriboIndenterTM TI 950 system has been
used for studying the local viscoelastic properties of porcine
intervertebral disc end plate by means of nanoscale mechanical
dynamic analysis. The specimen of an endplate was cut from fresh
porcine vertebra dissected from 16 month animal. The lumbar spine
motion segments were dissected and 5 millimeter thick plates of
vertebral body, endplate and annulus fibrosus were prepared for
nanoindentation. The surface of the sample was kept in physiological
solution during nanoindentation experiment. We obtained mechanical
characteristics of different areas of native endplate (endplate middle
and vertebra and annulus fibrosus boundary).
Abstract: The mineral having chemical compositional formula MgAl2O4 is called “spinel". The ferrites crystallize in spinel structure are known as spinel-ferrites or ferro-spinels. The spinel structure has a fcc cage of oxygen ions and the metallic cations are distributed among tetrahedral (A) and octahedral (B) interstitial voids (sites). The X-ray diffraction (XRD) intensity of each Bragg plane is sensitive to the distribution of cations in the interstitial voids of the spinel lattice. This leads to the method of determination of distribution of cations in the spinel oxides through XRD intensity analysis. The computer program for XRD intensity analysis has been developed in C language and also tested for the real experimental situation by synthesizing the spinel ferrite materials Mg0.6Zn0.4AlxFe2- xO4 and characterized them by X-ray diffractometry. The compositions of Mg0.6Zn0.4AlxFe2-xO4(x = 0.0 to 0.6) ferrites have been prepared by ceramic method and powder X-ray diffraction patterns were recorded. Thus, the authenticity of the program is checked by comparing the theoretically calculated data using computer simulation with the experimental ones. Further, the deduced cation distributions were used to fit the magnetization data using Localized canting of spins approach to explain the “recovery" of collinear spin structure due to Al3+ - substitution in Mg-Zn ferrites which is the case if A-site magnetic dilution and non-collinear spin structure. Since the distribution of cations in the spinel ferrites plays a very important role with regard to their electrical and magnetic properties, it is essential to determine the cation distribution in spinel lattice.
Abstract: The aim of present experiment was to evaluate the
influence of cultivar to quality parameters of dried potato chips and
sticks produced in microwave-vacuum drier. The potatoes before
drying were blanched in oil and water at 180ºC and at 85ºC
respectively. The moisture content, crispiness, the colour (CIE
L*a*b*), the content of ascorbic acid, total carotenoids and total fat
content of dried potato chips and sticks was determined The highest
ascorbic acid content, high content of carotenoids, low total fat
content, low acrylamide content and good crispiness (low breaking
force) especially for sticks was determined in the samples of Gundega
cultivar.
Abstract: In quality control of freeze-dried durian, crispiness is
a key quality index of the product. Generally, crispy testing has to be
done by a destructive method. A nondestructive testing of the
crispiness is required because the samples can be reused for other
kinds of testing. This paper proposed a crispiness classification
method of freeze-dried durians using fuzzy logic for decision
making. The physical changes of a freeze-dried durian include the
pores appearing in the images. Three physical features including (1)
the diameters of pores, (2) the ratio of the pore area and the
remaining area, and (3) the distribution of the pores are considered to
contribute to the crispiness. The fuzzy logic is applied for making the
decision. The experimental results comparing with food expert
opinion showed that the accuracy of the proposed classification
method is 83.33 percent.
Abstract: The paper relates to a catalyst, comprising copperchromium
spinel, coated on carrier γ-Al2O3. The effect of preparation
conditions on the active component composition and activity
behavior of the catalysts is discussed. It was found that the activity of
carbon monoxide, DME, formaldehyde and methanol oxidation
reaches a maximum at an active component content of 20 – 30 wt. %.
Temperature calcination at 500oC seems to be optimal for the γ–
alumina supported CuO-Cr2O3 catalysts for CO, DME, formaldehyde
and methanol oxidation. A three months industrial experiment was
carried out to elucidate the changes in the catalyst composition
during industrial exploitation of the catalyst and the main reasons for
catalyst deactivation.
It was concluded that the CuO–Cr2O3/γ–alumina supported
catalysts have enhanced activity toward CO, DME, formaldehyde
and methanol oxidation and that these catalysts are suitable for
industrial application. The main reason for catalyst deactivation
seems to be the deposition of iron and molybdenum, coming from the
main reactor, on the active component surface.
Abstract: For maintenance of a spine stability during the
postoperative period a transpedicular fixing of its elements is often
used. Usually the transpedicular systems are formed of rods which as
a result form a design of the frame type, fastening by screws to
vertebras. Such design should be rigid and perceive loadings
operating from the spine without essential deformations. From the
perfection point of view of known designs their stress
whole, and each of elements, in particular is of interest. In this study
the modeling of the transpedicular screw is performed and
estimation of its deformations taking into account interaction with a
vertebra body having variable structure is made.