Abstract: The pullout strength had an effect on the stability of
plate screw fixation when inserted in the cervical spine. Nine
different titanium alloy bone screws were used to test the pullout
strength through finite element analysis. The result showed that the
Moss Miami I can bear the highest pullout force at 1,075 N, which
causes the maximum von Mises stress at 858.87 MPa, a value over
the yield strength of titanium. The bone screw should have large
outer diameter, core diameter and proximal root radius to increase the
pullout strength.
Abstract: The aim of this study is to develop an anterior lumbar
interbody fusion (ALIF) PEEK cage suitable for Korean people. In this
study, CT images were obtained from Korean male (173cm, 71kg) and
3D Korean lumbar models were reconstructed based on the CT images
to investigate anatomical characteristics. Major design parameters of
anterior lumbar interbody fusion (ALIF) PEEK Cage were selected
using the morphological measurement information of the Korean
Lumbar models. Through finite element analysis and mechanical tests,
the developed ALIFPEEK Cage prototype was compared with the
Fidji Cage (Zimmer. Inc, USA) and it was found that the ALIF
prototype showed similar and/or superior mechanical performance
compared to the FidJi Cage. Also, clinical validation for the ALIF
PEEK Cage prototype was carried out to check predictable troubles in
surgical operations. Finally, it is considered that the convenience and
stability of the prototype was clinically verified.
Abstract: A novel hybrid model of the lumbar spine, allowing
fast static and dynamic simulations of the disc pressure
and the spine mobility, is introduced in this work. Our
contribution is to combine rigid bodies, deformable finite
elements, articular constraints, and springs into a unique model
of the spine. Each vertebra is represented by a rigid body
controlling a surface mesh to model contacts on the facet
joints and the spinous process. The discs are modeled using
a heterogeneous tetrahedral finite element model. The facet
joints are represented as elastic joints with six degrees of
freedom, while the ligaments are modeled using non-linear
one-dimensional elastic elements. The challenge we tackle
is to make these different models efficiently interact while
respecting the principles of Anatomy and Mechanics.
The mobility, the intradiscal pressure, the facet joint force and
the instantaneous center of rotation of the lumbar spine are
validated against the experimental and theoretical results of
the literature on flexion, extension, lateral bending as well as
axial rotation.
Our hybrid model greatly simplifies the modeling task and
dramatically accelerates the simulation of pressure within the
discs, as well as the evaluation of the range of motion and the
instantaneous centers of rotation, without penalizing precision.
These results suggest that for some types of biomechanical
simulations, simplified models allow far easier modeling and
faster simulations compared to usual full-FEM approaches
without any loss of accuracy.
Abstract: In this paper, the construction of a detailed spine
model is presented using the LifeMOD Biomechanics Modeler. The
detailed spine model is obtained by refining spine segments in
cervical, thoracic and lumbar regions into individual vertebra
segments, using bushing elements representing the intervertebral
discs, and building various ligamentous soft tissues between
vertebrae. In the sagittal plane of the spine, constant force will be
applied from the posterior to anterior during simulation to determine
dynamic characteristics of the spine. The force magnitude is
gradually increased in subsequent simulations. Based on these
recorded dynamic properties, graphs of displacement-force
relationships will be established in terms of polynomial functions by
using the least-squares method and imported into a haptic integrated
graphic environment. A thoracolumbar spine model with complex
geometry of vertebrae, which is digitized from a resin spine
prototype, will be utilized in this environment. By using the haptic
technique, surgeons can touch as well as apply forces to the spine
model through haptic devices to observe the locomotion of the spine
which is computed from the displacement-force relationship graphs.
This current study provides a preliminary picture of our ongoing
work towards building and simulating bio-fidelity scoliotic spine
models in a haptic integrated graphic environment whose dynamic
properties are obtained from LifeMOD. These models can be helpful
for surgeons to examine kinematic behaviors of scoliotic spines and
to propose possible surgical plans before spine correction operations.
Abstract: The overall penumbra is usually defined as the
distance, p20–80, separating the 20% and 80% of the dose on the beam axis at the depth of interest. This overall penumbra accounts
also for the fact that some photons emitted by the distal parts of the source are only partially attenuated by the collimator. Medulloblastoma is the most common type of childhood brain tumor
and often spreads to the spine. Current guidelines call for surgery to remove as much of the tumor as possible, followed by radiation of the brain and spinal cord, and finally treatment with chemotherapy.
The purpose of this paper was to present results on an Uniformity of dose distribution in radiation fields surrounding the spine using film