Abstract: A smart grid is an emerging technology in the power delivery system which provides an intelligent, self-recovery and homeostatic grid in delivering power to the users. Smart grid communication network provides transmission capacity for information transformation within the connected nodes in the network, in favor of functional and operational needs. In the electric grids communication network delay is based on choosing the appropriate technology and the types of devices enforced. In distinction, the combination of IEEE 802.16 based WiMAX and IEEE 802.11 based WiFi technologies provides improved coverage and gives low delay performances to meet the smart grid needs. By incorporating this method in Wide Area Monitoring System (WAMS) and Advanced Metering Infrastructure (AMI) the performance of the smart grid will be considerably improved. This work deals with the implementation of WiMAX-WLAN integrated network architecture for WAMS and AMI in the smart grid.
Abstract: More than half of the urban population in Romania lives today in residential buildings made out of large prefabricated reinforced concrete panels. Since their initial design was made in the 1960’s, these housing units are now being technically and morally outdated, consuming large amounts of energy for heating, cooling, ventilation and lighting, while failing to meet the needs of the contemporary life-style. Due to their widespread use, the design of a system that improves their energy efficiency would have a real impact, not only on the energy consumption of the residential sector, but also on the quality of life that it offers. Furthermore, with the transition of today’s existing power grid to a “smart grid”, buildings could become an active element for future electricity networks by contributing in micro-generation and energy storage. One of the most addressed issues today is to find locally adapted strategies that can be applied considering the 20-20-20 EU policy criteria and to offer sustainable and innovative solutions for the cost-optimal energy performance of buildings adapted on the existing local market. This paper presents a possible adaptive design scenario towards sustainable retrofitting of these housing units. The apartments are transformed in order to meet the current living requirements and additional extensions are placed on top of the building, replacing the unused roof space, acting not only as housing units, but as active solar energy collection systems. An adaptive building envelope is ensured in order to achieve overall air-tightness and an elevator system is introduced to facilitate access to the upper levels.
Abstract: This paper presents hierarchical operation strategies which are minimizing operation error between day ahead operation plan and real time operation. Operating power systems between centralized and decentralized approaches can be represented as hierarchical control scheme, featured as primary control, secondary control and tertiary control. Primary control is known as local control, featuring fast response. Secondary control is referred to as microgrid Energy Management System (EMS). Tertiary control is responsible of coordinating the operations of multi-microgrids. In this paper, we formulated 3 stage microgrid operation strategies which are similar to hierarchical control scheme. First stage is to set a day ahead scheduled output power of Battery Energy Storage System (BESS) which is only controllable source in microgrid and it is optimized to minimize cost of exchanged power with main grid using Particle Swarm Optimization (PSO) method. Second stage is to control the active and reactive power of BESS to be operated in day ahead scheduled plan in case that State of Charge (SOC) error occurs between real time and scheduled plan. The third is rescheduling the system when the predicted error is over the limited value. The first stage can be compared with the secondary control in that it adjusts the active power. The second stage is comparable to the primary control in that it controls the error in local manner. The third stage is compared with the secondary control in that it manages power balancing. The proposed strategies will be applied to one of the buildings in Electronics and Telecommunication Research Institute (ETRI). The building microgrid is composed of Photovoltaic (PV) generation, BESS and load and it will be interconnected with the main grid. Main purpose of that is minimizing operation cost and to be operated in scheduled plan. Simulation results support validation of proposed strategies.
Abstract: The advancement of hybrid energy resources such as solar and wind power leading to the emergence of customer owned grid. It provides an opportunity to regulars to obtain low energy costs as well as enabling the power supplier to regulate the utility grid. There is a need to develop smart systems that will automatically submit energy demand schedule and monitors energy price signals in real-time without the prompt of customers. In this paper, a demand side energy management for a grid connected household and also smart preparation of electrical appliance have been presented. It also reduces electricity bill for the consumers in the grid. In addition to this, when production is high, the surplus energy fashioned in the customer owned grid is given to main grid or neighboring micro grids. The simulation of the entire system is presented using LabVIEW software.
Abstract: The issue of unintentional islanding detection of grid connected synchronous distributed generation (SDG) remains the most challenging task faced by the distributed generation (DG) industry as SDG is highly capable of prolonging an island. This paper gives an insight of anti-islanding detection techniques mainly applied for SDG. Different techniques conclude that it is challenging to point out a generic method for a distinct purpose as the application of particular practice depends on nature of the end use and system dependent elements. Also, the setup and operational cost affect the selection of anti-islanding technique to achieve minimal compromising between cost and system quality. A test bench is created in the MATLAB/Simulink® to demonstrate the results of a 33 kV system. The results are highly satisfactory and they are according to the current practices.
Abstract: In this paper, we present a high order group explicit method in solving the two dimensional Helmholtz equation. The presented method is derived from a nine-point fourth order finite difference approximation formula obtained from a 45-degree rotation of the standard grid which makes it possible for the construction of iterative procedure with reduced complexity. The developed method will be compared with the existing group iterative schemes available in literature in terms of computational time, iteration counts, and computational complexity. The comparative performances of the methods will be discussed and reported.
Abstract: More PV systems have been connected to the electrical network each year. As the number of PV systems increases, some issues affecting grid operations have been identified. This paper studied the impacts related to changes in solar irradiance on a distribution/sub-transmission network, considering variations due to moving clouds and daily cycles. Using MATLAB/Simulink software, a solar farm of 30 MWp was built and then implemented to a test network. From simulations, it has been determined that irradiance changes can have a significant impact on the grid by causing voltage fluctuations outside the allowable thresholds. This work discussed some local control strategies and grid reinforcements to mitigate the negative effects of the irradiance changes on the grid.
Abstract: The present study aimed to know the role of verbal bullying in the lives of obese teenagers exposed to it. The study employed a qualitative design specifically the phenomenological approach that focuses on the obese teenagers’ verbal bullying experiences. The study also used the social constructivism approach wherein it described the obese teenagers’ verbal bullying experiences as they interact with the social world. Through purposive and referral sampling technique, the researchers were able to choose twelve (12) respondents from different schools around the City of Manila, enrolled in the School Year 2015-2016, ages 16-21 years old, has experienced verbal bullying for the last ten (10) years and with the Body Mass Index (BMI) of equal to or greater than 30. Upon the consent of the respondents, ethical considerations were ensured. In-depth one (1) hour interviews were guided by the researchers’ aide memoir. The recorded interviews were transcribed into a field text and the responses were thoroughly analyzed through Thematic Analysis and Kelly’s Repertory Grid. It was found that the role of verbal bullying in the lives of obese teenagers exposed to it is a process and is best described through a syringe, or the 5S Responses of Obese Teenagers in Bullying, with five conceptual themes which also signify the experiences and the process that obese teenagers have gone through after experiencing verbal bullying. The themes conceptualized were: Suffering, self-doubt, suppression, self-acceptance and sanguineness. This paper may serve as a basis for a counseling program to help the obese teenagers cope with their bullying experiences.
Abstract: In designing a low-energy-consuming buildings, the heat transfer through a large glass or wall becomes critical. Multiple layers of the window glasses and walls are employed for the high insulation. The gravity driven air flow between window glasses or wall layers is a natural heat convection phenomenon being a key of the heat transfer. For the first step of the natural heat transfer analysis, in this study the development and application of a finite volume method for the numerical computation of viscous incompressible flows is presented. It will become a part of the natural convection analysis with high-order scheme, multi-grid method, and dual-time step in the future. A finite volume method based on a fully-implicit second-order is used to discretize and solve the fluid flow on unstructured grids composed of arbitrary-shaped cells. The integrations of the governing equation are discretised in the finite volume manner using a collocated arrangement of variables. The convergence of the SIMPLE segregated algorithm for the solution of the coupled nonlinear algebraic equations is accelerated by using a sparse matrix solver such as BiCGSTAB. The method used in the present study is verified by applying it to some flows for which either the numerical solution is known or the solution can be obtained using another numerical technique available in the other researches. The accuracy of the method is assessed through the grid refinement.
Abstract: The stability is an important topic to plan and manage the energy in the microgrids as the same as the conventional power systems. The voltage and frequency stability is one of the most important issues recently studied in microgrids. The objectives of this paper are the modelling and designing of the components and optimal controllers for the voltage and frequency control of the AC/DC hybrid microgrid under the different disturbances. Since the PI controllers have the advantages of simple structure and easy implementation, so they are designed and modeled in this paper. The harmony search (HS) algorithm is used to optimize the controllers’ parameters. According to the achieved results, the PI controllers have a good performance in voltage and frequency control of the microgrid.
Abstract: In the standards of IEC 60076-2 and IEC 60076-7, three different hot-spot temperature estimation methods are suggested. In this study, the algorithms which used in hot-spot temperature calculations are analyzed by comparing the algorithms with the results of an experimental set-up made by a Transformer Monitoring System (TMS) in use. In tested system, TMS uses only top oil temperature and load ratio for hot-spot temperature calculation. And also, it uses some constants from standards which are on agreed statements tables. During the tests, it came out that hot-spot temperature calculation method is just making a simple calculation and not uses significant all other variables that could affect the hot-spot temperature.
Abstract: This paper investigates the effects of breaks in bonds,
breaks in the earthing system and breaks in earth wire on the rise of
the earth potential (EPR) in a substation and at the transmission tower
bases using various models of an L6 tower. Different approaches
were adopted to examine the integrity of the earthing system and the
terminal towers. These effects were investigated to see the associated
difference in the EPR magnitudes with respect to a healthy system at
various locations. Comparisons of the computed EPR magnitudes
were then made between the healthy and unhealthy system to detect
any difference. The studies were conducted at power frequency for a
uniform soil with different soil resistivities. It was found that full
breaks in the double bond of the terminal towers increase the EPR
significantly at the fault location, while they reduce EPR at the
terminal tower bases. A fault on the isolated section of the grid can
result in EPR values up to 8 times of those on a healthy system at
higher soil resistivities, provided that the extended earthing system
stays connected to the grid.
Abstract: Smart metering and demand response are gaining
ground in industrial and residential applications. Smart Appliances
have been given concern towards achieving Smart home. The success
of Smart grid development relies on the successful implementation of
Information and Communication Technology (ICT) in power sector.
Smart Appliances have been the technology under development and
many new contributions to its realization have been reported in the
last few years. The role of ICT here is to capture data in real time,
thereby allowing bi-directional flow of information/data between
producing and utilization point; that lead a way for the attainment of
Smart appliances where home appliances can communicate between
themselves and provide a self-control (switch on and off) using the
signal (information) obtained from the grid. This paper depicts the
background on ICT for smart appliances paying a particular attention
to the current technology and identifying the future ICT trends for
load monitoring through which smart appliances can be achieved to
facilitate an efficient smart home system which promote demand
response program. This paper grouped and reviewed the recent
contributions, in order to establish the current state of the art and
trends of the technology, so that the reader can be provided with a
comprehensive and insightful review of where ICT for smart
appliances stands and is heading to. The paper also presents a brief
overview of communication types, and then narrowed the discussion
to the load monitoring (Non-intrusive Appliances Load Monitoring
‘NALM’). Finally, some future trends and challenges in the further
development of the ICT framework are discussed to motivate future
contributions that address open problems and explore new
possibilities.
Abstract: The application of ESS (Energy Storage Systems) in
the future grids has been the solution of the microgrid. However, high
investment costs necessitate accurate modeling and control strategy of
ESS to justify its economic viability and further underutilization.
Therefore, the reasonable control strategy for ESS which is subjected
to generator and usage helps to curtail the cost of investment and
operation costs. The rated frequency in power system is decreased
when the load is increasing unexpectedly; hence the thermal power is
operated at the capacity of only its 95% for the Governor Free (GF) to
adjust the frequency as reserve (5%) in practice. The ESS can be
utilized with governor at the same time for the frequency response due
to characteristic of its fast response speed and moreover, the cost of
ESS is declined rapidly to the reasonable price. This paper presents the
ESS control strategy to extend usage of the ESS taken account into
governor’s ramp rate and reduce the governor’s intervention as well.
All results in this paper are simulated by MATLAB.
Abstract: The photovoltaic (PV) panel with no galvanic
isolation system is well known technique in the world which is
effective and delivers power with enhanced efficiency. The PV
generation presented here is for stand-alone system installed in
remote areas when as the resulting power gets connected to electronic
load installation instead of being tied to the grid. Though very small,
even then transformer-less topology is shown to be with leakage in
pico-ampere range. By using PWM technique PWM, leakage current
in different situations is shown. The results shown in this paper show
how the pico-ampere current is reduced to femto-ampere through use
of inductors and capacitors of suitable values of inductor and
capacitors with the load.
Abstract: There are a number of Distributed Generations (DGs)
installed in microgrid, which may have diverse path and direction of
power flow or fault current. The overcurrent protection scheme for the
traditional radial type distribution system will no longer meet the
needs of microgrid protection. Integrating the Intelligent Electronic
Device (IED) and a Supervisory Control and Data Acquisition
(SCADA) with IEC 61850 communication protocol, the paper
proposes a Microgrid Protection Management System (MPMS) to
protect power system from the fault. In the proposed method, the
MPMS performs logic programming of each IED to coordinate their
tripping sequence. The GOOSE message defined in IEC 61850 is used
as the transmission information medium among IEDs. Moreover, to
cope with the difference in fault current of microgrid between
grid-connected mode and islanded mode, the proposed MPMS applies
the group setting feature of IED to protect system and robust
adaptability. Once the microgrid topology varies, the MPMS will
recalculate the fault current and update the group setting of IED.
Provided there is a fault, IEDs will isolate the fault at once. Finally, the
Matlab/Simulink and Elipse Power Studio software are used to
simulate and demonstrate the feasibility of the proposed method.
Abstract: This paper introduces a method to optimal design of a
hybrid Wind/Photovoltaic/Fuel cell generation system for a typical
domestic load that is not located near the electricity grid. In this
configuration the combination of a battery, an electrolyser, and a
hydrogen storage tank are used as the energy storage system. The aim
of this design is minimization of overall cost of generation scheme
over 20 years of operation. The Matlab/Simulink is applied for
choosing the appropriate structure and the optimization of system
sizing. A teaching learning based optimization is used to optimize the
cost function. An overall power management strategy is designed for
the proposed system to manage power flows among the different
energy sources and the storage unit in the system. The results have
been analyzed in terms of technical and economic. The simulation
results indicate that the proposed hybrid system would be a feasible
solution for stand-alone applications at remote locations.
Abstract: This paper presents a power control for a Doubly Fed
Induction Generator (DFIG) using in Wind Energy Conversion
System (WECS) connected to the grid. The proposed control strategy
employs two nonlinear controllers, Backstipping (BSC) and slidingmode
controller (SMC) scheme to directly calculate the required
rotor control voltage so as to eliminate the instantaneous errors of
active and reactive powers. In this paper the advantages of BSC and
SMC are presented, the performance and robustness of this two
controller’s strategy are compared between them. First, we present a
model of wind turbine and DFIG machine, then a synthesis of the
controllers and their application in the DFIG power control.
Simulation results on a 1.5MW grid-connected DFIG system are
provided by MATLAB/Simulink.
Abstract: Spacer grid assembly supporting the nuclear fuel rods
is an important concern in the design of structural components of a
Pressurized Water Reactor (PWR). The spacer grid is composed by
springs and dimples which are formed from a strip sheet by means of
blanking and stamping processes. In this paper, the blanking process
and tooling parameters are evaluated by means of a 2D plane-strain
finite element model in order to evaluate the punch load and quality
of the sheared edges of Inconel 718 strips used for nuclear spacer
grids. A 3D finite element model is also proposed to predict the
tooling loads resulting from the stamping process of a preformed
Inconel 718 strip and to analyse the residual stress effects upon the
spring and dimple design geometries of a nuclear spacer grid.
Abstract: This paper presents dynamic models of distributed
generators (DG) and investigates dynamic behavior of the DG units
in the micro grid system. The DG units include photovoltaic and fuel
cell sources. The voltage source inverter is adopted since the
electronic interface which can be equipped with its controller to keep
stability of the micro grid during small signal dynamics. This paper
also introduces power management strategies and implements the DG
load sharing concept to keep the micro grid operation in gridconnected
and islanding modes of operation. The results demonstrate
the operation and performance of the photovoltaic and fuel cell as
distributed generators in a micro grid. The entire control system in
the micro grid is developed by combining the benefits of the power
control and the voltage control strategies. Simulation results are all
reported, confirming the validity of the proposed control technique.