Abstract: Installations of solar photovoltaic systems have increased considerably in the last decade. Therefore, it has been noticed that monitoring of meteorological data (solar irradiance, air temperature, wind velocity, etc.) is important to predict the potential of a given geographical area in solar energy production. In this sense, the present work compares two computational tools that are capable of estimating the energy generation of a photovoltaic system through correlation analyzes of solar radiation data: PVsyst software and an algorithm based on the PVlib package implemented in MATLAB. In order to achieve the objective, it was necessary to obtain solar radiation data (measured and from a solarimetric database), analyze the decomposition of global solar irradiance in direct normal and horizontal diffuse components, as well as analyze the modeling of the devices of a photovoltaic system (solar modules and inverters) for energy production calculations. Simulated results were compared with experimental data in order to evaluate the performance of the studied methods. Errors in estimation of energy production were less than 30% for the MATLAB algorithm and less than 20% for the PVsyst software.
Abstract: The present paper aims to the techno-economic feasibility of enhancing low-cost parabolic trough collectors in the light of developing the use of solar energy in under-developed regions where expensive high-tech solar devices cannot be afforded. Moreover, the collector is aimed to produce steam so that its performance is based on heat which can be discovered. In this regard, the manufacturing process and the detailed design models in Solidworks software are elaborated. Furthermore, the colletor’s material is chosen in a way to minimize the costs. Finally, to assess the performance of the built collector, it is installed in the site of Shahid Beheshti University, Tehran, and the values of the effective peripheral parameters, such as temperature, wind speed, and most importantly, solar irradiance, are recorded simultaneously in June. According to the results obtained, the manufactured collector with the aperture area of 2 m2 (1×2 m) is capable of producing 350 ml.h-1 steam. Also, the wind influence is comprehensively investigated in this paper. As a case in point, it was measured that as the wind speed maximized to 9.77 km/h, the amount of steam outlet is minimized to 580 ml.
Abstract: In photovoltaic (PV) cells, most of the absorbed solar radiation cannot be converted into electricity. A large amount of solar radiation is converted to heat, which should be dissipated by any cooling techniques. In the present study, the cooling is achieved by inserting triangular ribs in the duct. A comprehensive two-dimensional thermo-fluid model for the effective cooling of PV cells has been developed. It has been first carefully validated against experimental and numerical results available in the literature. A parametric analysis was then carried out about the influence of the number and size of the ribs, wind speed, solar irradiance and inlet fluid velocity on the average solar cell and outlet air temperatures as well as the thermal and electrical efficiencies of the module. Results indicated that the use of triangular ribbed channels is a very effective cooling technique, which significantly reduces the average temperature of the PV cell, especially when increasing the number of ribs.
Abstract: Replacing of complex solar concentrating unit, this paper designs a solar heat-concentrating medium-temperature steam-generating system. Solar radiation is collected by using a large solar collecting and heat concentrating plate and is converged to the metal evaporating pipe with high efficient heat transfer. In the meantime, the heat loss is reduced by employing a double-glazed cover and other heat insulating structures. Thus, a high temperature is reached in the metal evaporating pipe. The influences of the system's structure parameters on system performance are analyzed. The steam production rate and the steam production under different solar irradiance, solar collecting and heat concentrating plate area, solar collecting and heat concentrating plate temperature and heat loss are obtained. The results show that when solar irradiance is higher than 600 W/m2, the effective heat collecting area is 7.6 m2 and the double-glazing cover is adopted, the system heat loss amount is lower than the solar irradiance value. The stable steam is produced in the metal evaporating pipe at 100 ℃, 110 ℃, and 120 ℃, respectively. When the average solar irradiance is about 896 W/m2, and the steaming cumulative time is about 5 hours, the daily steam production of the system is about 6.174 kg. In a single day, the solar irradiance is larger at noon, thus the steam production rate is large at that time. Before 9:00 and after 16:00, the solar irradiance is smaller, and the steam production rate is almost 0.
Abstract: Solar photovoltaic (SPV) power systems can be
employed as electrical power sources to meet the daily residential
energy needs of rural areas that have no access to grid systems.
In view of this, a standalone SPV powered air cooling system is
proposed in this paper, which constitutes a dc-dc boost converter,
two voltage source inverters (VSI) connected to two brushless dc
(BLDC) motors which are coupled to a centrifugal water pump and
a fan blower. A simple and efficient Maximum Power Point Tracking
(MPPT) technique based on Silver Mean Method (SMM) is utilized
in this paper. The air cooling system is developed and simulated using
the MATLAB / Simulink environment considering the dynamic and
steady state variation in the solar irradiance.
Abstract: More PV systems have been connected to the electrical network each year. As the number of PV systems increases, some issues affecting grid operations have been identified. This paper studied the impacts related to changes in solar irradiance on a distribution/sub-transmission network, considering variations due to moving clouds and daily cycles. Using MATLAB/Simulink software, a solar farm of 30 MWp was built and then implemented to a test network. From simulations, it has been determined that irradiance changes can have a significant impact on the grid by causing voltage fluctuations outside the allowable thresholds. This work discussed some local control strategies and grid reinforcements to mitigate the negative effects of the irradiance changes on the grid.
Abstract: In this study, we proposed two techniques to track the
maximum power point (MPPT) of a photovoltaic system. The first is
an intelligent control technique, and the second is robust used for
variable structure system. In fact the characteristics I-V and P–V of
the photovoltaic generator depends on the solar irradiance and
temperature. These climate changes cause the fluctuation of
maximum power point; a maximum power point tracking technique
(MPPT) is required to maximize the output power. For this we have
adopted a control by fuzzy logic (FLC) famous for its stability and
robustness. And a Siding Mode Control (SMC) widely used for
variable structure system. The system comprises a photovoltaic panel
(PV), a DC-DC converter, which is considered as an adaptation stage
between the PV and the load. The modelling and simulation of the
system is developed using MATLAB/Simulink. SMC technique
provides a good tracking speed in fast changing irradiation and when
the irradiation changes slowly or it is constant the panel power of
FLC technique presents a much smoother signal with less
fluctuations.
Abstract: This study investigates how AlGaAs/GaAs thin film
solar cells perform under varying global solar spectrum due to the
changes of environmental parameters such as the air mass and the
atmospheric turbidity. The solar irradiance striking the solar cell is
simulated using the spectral irradiance model SMARTS2 (Simple
Model of the Atmospheric Radiative Transfer of Sunshine) for clear
skies on the site of Setif (Algeria). The results show a reduction in the
short circuit current due to increasing atmospheric turbidity, it is
63.09% under global radiation. However increasing air mass leads to
a reduction in the short circuit current of 81.73%. The efficiency
decreases with increasing atmospheric turbidity and air mass.
Abstract: In this paper, the optimum design for renewable energy system powered an aquaculture pond was determined. Hybrid Optimization Model for Electric Renewable (HOMER) software program, which is developed by U.S National Renewable Energy Laboratory (NREL), is used for analyzing the feasibility of the stand alone and hybrid system in this study. HOMER program determines whether renewable energy resources satisfy hourly electric demand or not. The program calculates energy balance for every 8760 hours in a year to simulate operation of the system. This optimization compares the demand for the electrical energy for each hour of the year with the energy supplied by the system for that hour and calculates the relevant energy flow for each component in the model. The essential principle is to minimize the total system cost while HOMER ensures control of the system. Moreover the feasibility analysis of the energy system is also studied. Wind speed, solar irradiance, interest rate and capacity shortage are the parameters which are taken into consideration. The simulation results indicate that the hybrid system is the best choice in this study, yielding lower net present cost. Thus, it provides higher system performance than PV or wind stand alone systems.
Abstract: The work presented in this study is related to an
energy system analysis based on passive cooling system for
dwellings. It consists to solar chimney energy performances
determination versus geometrical and environmental considerations
as the size and inlet width conditions of the chimney. Adrar site
located in the southern region of Algeria is chosen for this study
according to ambient temperature and solar irradiance technical data
availability. Obtained results are related to the glazing temperature
distributions, the chimney air flow and internal wall temperatures.
The air room change per hour (ACH) parameter, the outlet air
velocity and mass air flow rate are also determined. It is shown that
the chimney width has a significant effect on energy performances
compared to its entry size. A good agreement is observed between
these results and those obtained by others from the literature.
Abstract: The objectif of the present work is to determinate the
potential of the solar parabolic trough collector (PTC) for use in the
design of a solar thermal power plant in Algeria. The study is based
on a mathematical modeling of the PTC. Heat balance has been
established respectively on the heat transfer fluid (HTF), the absorber
tube and the glass envelop using the principle of energy conservation
at each surface of the HCE cross-sectionn. The modified Euler
method is used to solve the obtained differential equations. At first
the results for typical days of two seasons the thermal behavior of the
HTF, the absorber and the envelope are obtained. Then to determine
the thermal performances of the heat transfer fluid, different oils are
considered and their temperature and heat gain evolutions compared.
Abstract: This paper presents the exergy analysis of a
desalination unit using humidification-dehumidification process.
Here, this unit is considered as a thermal system with three main
components, which are the heating unit by using a solar collector, the
evaporator or the humidifier, and the condenser or the dehumidifier.
In these components the exergy is a measure of the quality or grade
of energy and it can be destroyed in them. According to the second
law of thermodynamics this destroyed part is due to irreversibilities
which must be determined to obtain the exergetic efficiency of the
system.
In the current paper a computer program has been developed using
visual basic to determine the exergy destruction and the exergetic
efficiencies of the components of the desalination unit at variable
operation conditions such as feed water temperature, outlet air
temperature, air to feed water mass ratio and salinity, in addition to
cooling water mass flow rate and inlet temperature, as well as
quantity of solar irradiance.
The results obtained indicate that the exergy efficiency of the
humidifier increases by increasing the mass ratio and decreasing the
outlet air temperature. In the other hand the exergy efficiency of the
condenser increases with the increase of this ratio and also with the
increase of the outlet air temperature.
Abstract: A novel typical day prediction model have been built and validated by the measured data of a grid-connected solar photovoltaic (PV) system in Macau. Unlike conventional statistical method used by previous study on PV systems which get results by averaging nearby continuous points, the present typical day statistical method obtain the value at every minute in a typical day by averaging discontinuous points at the same minute in different days. This typical day statistical method based on discontinuous point averaging makes it possible for us to obtain the Gaussian shape dynamical distributions for solar irradiance and output power in a yearly or monthly typical day. Based on the yearly typical day statistical analysis results, the maximum possible accumulated output energy in a year with on site climate conditions and the corresponding optimal PV system running time are obtained. Periodic Gaussian shape prediction models for solar irradiance, output energy and system energy efficiency have been built and their coefficients have been determined based on the yearly, maximum and minimum monthly typical day Gaussian distribution parameters, which are obtained from iterations for minimum Root Mean Squared Deviation (RMSD). With the present model, the dynamical effects due to time difference in a day are kept and the day to day uncertainty due to weather changing are smoothed but still included. The periodic Gaussian shape correlations for solar irradiance, output power and system energy efficiency have been compared favorably with data of the PV system in Macau and proved to be an improvement than previous models.