Investigation of the Effect of Impulse Voltage to Flashover by Using Water Jet

The main function of the insulators used in high voltage (HV) transmission lines is to insulate the energized conductor from the pole and hence from the ground. However, when the insulators fail to perform this insulation function due to various effects, failures occur. The deterioration of the insulation results either from breakdown or surface flashover. The surface flashover is caused by the layer of pollution that forms conductivity on the surface of the insulator, such as salt, carbonaceous compounds, rain, moisture, fog, dew, industrial pollution and desert dust. The source of the majority of failures and interruptions in HV lines is surface flashover. This threatens the continuity of supply and causes significant economic losses. Pollution flashover in HV insulators is still a serious problem that has not been fully resolved. In this study, a water jet test system has been established in order to investigate the behavior of insulators under dirty conditions and to determine their flashover performance. Flashover behavior of the insulators is examined by applying impulse voltages in the test system. This study aims to investigate the insulator behaviour under high impulse voltages. For this purpose, a water jet test system was installed and experimental results were obtained over a real system and analyzed. By using the water jet test system instead of the actual insulator, the damage to the insulator as a result of the flashover that would occur under impulse voltage was prevented. The results of the test system performed an important role in determining the insulator behavior and provided predictability.

Mechanical, Thermal and Biodegradable Properties of Bioplast-Spruce Green Wood Polymer Composites

Environmental and sustainability concerns push the industries to manufacture alternative materials having less environmental impact. The Wood Plastic Composites (WPCs) produced by blending the biopolymers and natural fillers permit not only to tailor the desired properties of materials but also are the solution to meet the environmental and sustainability requirements. This work presents the elaboration and characterization of the fully green WPCs prepared by blending a biopolymer, BIOPLAST® GS 2189 and spruce sawdust used as filler with different amounts. Since both components are bio-based, the resulting material is entirely environmentally friendly. The mechanical, thermal, structural properties of these WPCs were characterized by different analytical methods like tensile, flexural and impact tests, Thermogravimetric Analysis (TGA), Differential Scanning Calorimetry (DSC) and X-ray Diffraction (XRD). Their water absorption properties and resistance to the termite and fungal attacks were determined in relation with different wood filler content. The tensile and flexural moduli of WPCs increased with increasing amount of wood fillers into the biopolymer, but WPCs became more brittle compared to the neat polymer. Incorporation of spruce sawdust modified the thermal properties of polymer: The degradation, cold crystallization, and melting temperatures shifted to higher temperatures when spruce sawdust was added into polymer. The termite, fungal and water absorption resistance of WPCs decreased with increasing wood amount in WPCs, but remained in durability class 1 (durable) concerning fungal resistance and quoted 1 (attempted attack) in visual rating regarding to the termites resistance except that the WPC with the highest wood content (30 wt%) rated 2 (slight attack) indicating a long term durability. All the results showed the possibility to elaborate the easy injectable composite materials with adjustable properties by incorporation of BIOPLAST® GS 2189 and spruce sawdust. Therefore, lightweight WPCs allow both to recycle wood industry byproducts and to produce a full ecologic material.

Air Classification of Dust from Steel Converter Secondary De-dusting for Zinc Enrichment

The off-gas from the basic oxygen furnace (BOF), where pig iron is converted into steel, is treated in the primary ventilation system. This system is in full operation only during oxygen-blowing when the BOF converter vessel is in a vertical position. When pig iron and scrap are charged into the BOF and when slag or steel are tapped, the vessel is tilted. The generated emissions during charging and tapping cannot be captured by the primary off-gas system. To capture these emissions, a secondary ventilation system is usually installed. The emissions are captured by a canopy hood installed just above the converter mouth in tilted position. The aim of this study was to investigate the dependence of Zn and other components on the particle size of BOF secondary ventilation dust. Because of the high temperature of the BOF process it can be expected that Zn will be enriched in the fine dust fractions. If Zn is enriched in the fine fractions, classification could be applied to split the dust into two size fractions with a different content of Zn. For this air classification experiments with dust from the secondary ventilation system of a BOF were performed. The results show that Zn and Pb are highly enriched in the finest dust fraction. For Cd, Cu and Sb the enrichment is less. In contrast, the non-volatile metals Al, Fe, Mn and Ti were depleted in the fine fractions. Thus, air classification could be considered for the treatment of dust from secondary BOF off-gas cleaning.

Dynamical Characteristics of Interaction between Water Droplet and Aerosol Particle in Dedusting Technology

With the rapid development of national modern industry, people begin to pay attention to environmental pollution and harm caused by industrial dust. Based on above, a numerical study on the dedusting technology of industrial environment was conducted. The dynamic models of multicomponent particles collision and coagulation, breakage and deposition are developed, and the interaction of water droplet and aerosol particle in 2-Dimension flow field was researched by Eulerian-Lagrangian method and Multi-Monte Carlo method. The effects of the droplet scale, movement speed of droplet and the flow field structure on scavenging efficiency were analyzed. The results show that under the certain condition, 30μm of droplet has the best scavenging efficiency. At the initial speed 1m/s of droplets, droplets and aerosol particles have more time to interact, so it has a better scavenging efficiency for the particle.

The Effects of Wood Ash on Ignition Point of Wood

The effects of wood ash from five common tropical woods on the ignition point of four common tropical woods in Nigeria were investigated. The ash and moisture contents of the wood sawdust from Mahogany (Khaya ivorensis), Opepe (Sarcocephalus latifolius), Abura (Mitragyna ciliata), Rubber (Heavea brasilensis) and Poroporo (Sorghum bicolour) used, were determined using a furnace (Vecstar furnaces, model ECF2, serial no. f3077) and oven (Genlab laboratory oven, model MINO/040) respectively. The metal contents of the five wood sawdust ash samples were determined using a Perkin Elmer optima 3000 dv atomic absorption spectrometer while the ignition points were determined using Vecstar furnaces model ECF2. Poroporo had the highest ash content, 2.263g while rubber had the least, 0.710g. The results for the moisture content range from 2.971g to 0.903g. Magnesium metal had the highest concentration of all the metals, in all the wood ash samples; with mahogany ash having the highest concentration, 9.196ppm while rubber ash had the least concentration of magnesium metal, 2.196 ppm. The ignition point results showed that the wood ashes from mahogany and opepe increased the ignition points of the test wood samples, Danta (Nesogordonia papaverifera), Ekpaya, Akomu (Pycnanthus angolensis) and Oleku when coated on them while the ashes from poroporo, rubber and abura decreased the ignition points of the test wood samples when coated on them. However, Opepe saw dust ash decreased the ignition point in one of the test wood samples, suggesting that the metal content of the test wood sample was more than that of the Opepe saw dust ash. Therefore, Mahogany and Opepe saw dust ashes could be used in the surface treatment of wood to enhance their fire resistance or retardancy. However, the caution to be exercised in this application is that the metal content of the test wood samples should be evaluated as well.

A Comparison of Air Quality in Arid and Temperate Climatic Conditions – A Case Study of Leeds and Makkah

In this paper air quality conditions in Makkah and Leeds are compared. These two cities have totally different climatic conditions. Makkah climate is characterised as hot and dry (arid) whereas that of Leeds is characterised as cold and wet (temperate). This study uses air quality data from 2012 collected in Makkah, Saudi Arabia and Leeds, UK. The concentrations of all pollutants, except NO are higher in Makkah. Most notable, the concentrations of PM10 are much higher in Makkah than in Leeds. This is probably due to the arid nature of climatic conditions in Makkah and not solely due to anthropogenic emission sources, otherwise like PM10 some of the other pollutants, such as CO, NO, and SO2 would have shown much greater difference between Leeds and Makkah. Correlation analysis is performed between different pollutants at the same site and the same pollutants at different sites. In Leeds the correlation between PM10 and other pollutants is significantly stronger than in Makkah. Weaker correlation in Makkah is probably due to the fact that in Makkah most of the gaseous pollutants are emitted by combustion processes, whereas most of the PM10 is generated by other sources, such as windblown dust, re-suspension, and construction activities. This is in contrast to Leeds where all pollutants including PM10 are predominantly emitted by combustions, such as road traffic. Furthermore, in Leeds frequent rains wash out most of the atmospheric particulate matter and suppress re-suspension of dust. Temporal trends of various pollutants are compared and discussed. This study emphasises the role of climatic conditions in managing air quality, and hence the need for region-specific controlling strategies according to the local climatic and meteorological conditions.

Annoyance Caused by Air Pollution: A Comparative Study of Two Industrialized Regions

Although there had been a many studies that shows the impact of air pollution on physical health, comparatively less was known of human behavioral responses and annoyance impacts. Annoyance caused by air pollution is a public health problem because it can be an ambient stressor causing stress and disease and can affect quality of life. The objective of this work is to evaluate the annoyance caused by air pollution in two different industrialized urban areas, Dunkirk (France) and Vitoria (Brazil). The populations of these cities often report feeling annoyed by dust. Surveys were conducted, and the collected data were analyzed using statistical analyses. The results show that sociodemographic variables, importance of air quality, perceived industrial risk, perceived air pollution and occurrence of health problems play important roles in the perceived annoyance. These results show the existence of a common problem in geographically distant areas and allow stakeholders to develop prevention strategies.

Variability of Metal Composition and Concentrations in Road Dust in the Urban Environment

Urban road dust comprises of a range of potentially  toxic metal elements and plays a critical role in degrading urban  receiving water quality. Hence, assessing the metal composition and  concentration in urban road dust is a high priority. This study  investigated the variability of metal composition and concentrations  in road dust in 4 different urban land uses in Gold Coast, Australia.  Samples from 16 road sites were collected and tested for selected 12  metal species. The data set was analyzed using both univariate and  multivariate techniques. Outcomes of the data analysis revealed that  the metal concentrations inroad dust differs considerably within and  between different land uses. Iron, aluminum, magnesium and zinc are  the most abundant in urban land uses. It was also noted that metal  species such as titanium, nickel, copper and zinc have the highest  concentrations in industrial land use. The study outcomes revealed  that soil and traffic related sources as key sources of metals deposited  on road surfaces.  

Thermo-Elastic Properties of Artificial Limestone Bricks with Wood Sawdust

In this study, artificial limestone brick samples are produced by using wood sawdust wastes (WSW) having different grades of sizes and limestone powder waste (LPW). The thermo-elastic properties of produced brick samples in various WSW amounts are investigated. At 30% WSW replacement with LPW in the brick sample the thermal conductivity value is effectively reduced and the reduction in the thermal conductivity value of brick sample at 30% WSW replacement with LPW is about 38.9% as compared with control sample. The energy conservation in buildings by using LPW and WSW in masonry brick material production having low thermal conductivity reduces energy requirements. A strong relationship is also found among the thermal conductivity, unit weight and ultrasonic pulse velocity values of brick samples produced. It shows a potential to be used for walls, wooden board substitute, alternative to the concrete blocks, ceiling panels, sound barrier panels, absorption materials etc.

Influence of Heterogeneous Traffic on the Roadside Fine (PM2.5 and PM1) and Coarse(PM10) Particulate Matter Concentrations in Chennai City, India

In this paper the influence of heterogeneous traffic on the temporal variation of ambient PM10, PM2.5 and PM1 concentrations at a busy arterial route (Sardar Patel Road) in the Chennai city has been analyzed. The hourly PM concentration, traffic counts and average speed of the vehicles have been monitored at the study site for one week (19th-25th January 2009). Results indicated that the concentrations of coarse (PM10) and fine PM (PM2.5 and PM1) concentrations at SP road are having similar trend during peak and non-peak hours, irrespective of the days. The PM concentrations showed daily two peaks corresponding to morning (8 to 10 am) and evening (7 to 9 pm) peak hour traffic flow. The PM10 concentration is dominated by fine particles (53% of PM2.5 and 45% of PM1). The high PM2.5/PM10 ratio indicates that the majority of PM10 particles originate from re-suspension of road dust. The analysis of traffic flow at the study site showed that 2W, 3W and 4W are having similar diurnal trend as PM concentrations. This confirms that the 2W, 3W and 4W are the main emission source contributing to ambient PM concentration at SP road. The speed measurement at SP road showed that the average speed of 2W, 3W, 4W, LCV and HCV are 38, 40, 38, 40 and 38 km/hr and 43, 41, 42, 40 and 41 km/hr respectively for the weekdays and weekdays.

Effect of Adding Sawdust on Mechanical- Physical Properties of Ceramic Bricks to Obtain Lightweight Building Material

This paper studies the application of a variety of sawdust materials in the production of lightweight insulating bricks. First, the mineralogical and chemical composition of clays was determined. Next, ceramic bricks were fabricated with different quantities of materials (3–6 and 9 wt. % for sawdust, 65 wt. % for grey clay, 24–27 and 30 wt. % for yellow clay and 2 wt% of tuff). These bricks were fired at 800 and 950 °C. The effect of adding this sawdust on the technological behaviour of the brick was assessed by drying and firing shrinkage, water absorption, porosity, bulk density and compressive strength. The results have shown that the optimum sintering temperature is 950 °C. Below this temperature, at 950 °C, increased open porosity was observed, which decreased the compressive strength of the bricks. Based on the results obtained, the optimum amounts of waste were 9 wt. % sawdust of eucalyptus, 24 wt. % shaping moisture and 1.6 particle size diameter. These percentages produced bricks whose mechanical properties were suitable for use as secondary raw materials in ceramic brick production.

Dust Acoustic Shock Waves in Coupled Dusty Plasmas with Kappa-Distributed Ions

We have considered an unmagnetized dusty plasma system consisting of ions obeying superthermal distribution and strongly coupled negatively charged dust. We have used reductive perturbation method and derived the Kordeweg-de Vries-Burgers (KdV-Burgers) equation. The behavior of the shock waves in the plasma has been investigated.

The Solar Wall in the Italian Climates

Passive systems were born with the purpose of the greatest exploitation of solar energy in cold climates and high altitudes. They spread themselves until the 80-s all over the world without any attention to the specific climate and the summer behavior; this caused the deactivation of the systems due to a series of problems connected to the summer overheating, the complex management and the rising of the dust. Until today the European regulation limits only the winter consumptions without any attention to the summer behavior but, the recent European EN 15251 underlines the relevance of the indoor comfort, and the necessity of the analytic studies validation by monitoring case studies. In the porpose paper we demonstrate that the solar wall is an efficient system both from thermal comfort and energy saving point of view and it is the most suitable for our temperate climates because it can be used as a passive cooling sistem too. In particular the paper present an experimental and numerical analisys carried out on a case study with nine different solar passive systems in Ancona, Italy. We carried out a detailed study of the lodging provided by the solar wall by the monitoring and the evaluation of the indoor conditions. Analyzing the monitored data, on the base of recognized models of comfort (ISO, ASHRAE, Givoni-s BBCC), is emerged that the solar wall has an optimal behavior in the middle seasons. In winter phase this passive system gives more advantages in terms of energy consumptions than the other systems, because it gives greater heat gain and therefore smaller consumptions. In summer, when outside air temperature return in the mean seasonal value, the indoor comfort is optimal thanks to an efficient transversal ventilation activated from the same wall.

Climatic Change, Drought and Dust Crisis in Iran

Drought is a phenomenon caused by environmental and climatic changes. This phenomenon is affected by shortage of rainfall and temperature. Dust is one of important environmental problems caused by climate change and drought. With recent multi-year drought, many environmental crises caused by dust in Iran and Middle East. Dust in the vast areas of the provinces occurs with high frequency. By dust affecting many problems created in terms of health, social and economic. In this study, we tried to study the most important factors causing dust. In this way we have used the satellite images and meteorological data. Finally, strategies to deal with the dust will be mentioned.

Studying the Effect of Climate Change on the Conditions of Isfahan-s Province Tourism

Tourism is a phenomenon respected by the human communities since a long time ago. It has been evoloving continually based on a variety of social and economic needs and with respect to increasingly development of communication and considerable increase of tourist-s number and resulted exchange income has attained much out come such as employment for the communities. or the purpose of tourism development in this zone suitable times and locations need to be specified in the zone for the tourist-s attendance. One of the most important needs of the tourists is the knowledge of climate conditions and suitable times for sightseeing. In this survey, the climate trend condition has been identified for attending the tourists in Isfahan province using the modified tourism climate index (TCI) as well as SPSS, GIS, excel, surfer softwares. This index evoluates systematically the climate conditions for tourism affairs and activities using the monthly maximum mean parameters of daily temperature, daily mean temperature, minimum relative humidity, daily mean relative humidity, precipitation (mm), total sunny hours, wind speed and dust. The results obtaind using kendal-s correlation test show that the months January, February, March, April, May, June, July, August, September, October, November and December are significant and have an increasing trend that indicates the best condition for attending the tourists. S, P, T mean , T max and dust are estimated from 1976-2005 and do kendal-s correlation test again to see which parameter has been effective. Based on the test, we also observed on the effective parameters that the rate of dust in February, March, April, May, June, July, August, October and November is decreasing and precipitation in September and January is increasing and also the radiation rate in May and August is increasing that indicate a better condition of convenience. Maximum temperature in June is also decreasing. Isfahan province has two spring and fall peaks and the best places for tourism are in the north and western areas.

Beneficial Use of Coal Combustion By-products in the Rehabilitation of Failed Asphalt Pavements

This study demonstrates the use of Class F fly ash in combination with lime or lime kiln dust in the full depth reclamation (FDR) of asphalt pavements. FDR, in the context of this paper, is a process of pulverizing a predetermined amount of flexible pavement that is structurally deficient, blending it with chemical additives and water, and compacting it in place to construct a new stabilized base course. Test sections of two structurally deficient asphalt pavements were reclaimed using Class F fly ash in combination with lime and lime kiln dust. In addition, control sections were constructed using cement, cement and emulsion, lime kiln dust and emulsion, and mill and fill. The service performance and structural behavior of the FDR pavement test sections were monitored to determine how the fly ash sections compared to other more traditional pavement rehabilitation techniques. Service performance and structural behavior were determined with the use of sensors embedded in the road and Falling Weight Deflectometer (FWD) tests. Monitoring results of the FWD tests conducted up to 2 years after reclamation show that the cement, fly ash+LKD, and fly ash+lime sections exhibited two year resilient modulus values comparable to open graded cement stabilized aggregates (more than 750 ksi). The cement treatment resulted in a significant increase in resilient modulus within 3 weeks of construction and beyond this curing time, the stiffness increase was slow. On the other hand, the fly ash+LKD and fly ash+lime test sections indicated slower shorter-term increase in stiffness. The fly ash+LKD and fly ash+lime section average resilient modulus values at two years after construction were in excess of 800 ksi. Additional longer-term testing data will be available from ongoing pavement performance and environmental condition data collection at the two pavement sites.