Abstract: This paper presents a model predictive control (MPC)
of a utility interactive (UI) single phase inverter (SPI) for a
photovoltaic (PV) system at residential/distribution level. The
proposed model uses single-phase phase locked loop (PLL) to
synchronize SPI with the grid and performs MPC control in a dq
reference frame. SPI model consists of boost converter (BC),
maximum power point tracking (MPPT) control, and a full bridge
(FB) voltage source inverter (VSI). No PI regulators to tune and
carrier and modulating waves are required to produce switching
sequence. Instead, the operational model of VSI is used to synthesize
sinusoidal current and track the reference. Model is validated using a
three kW PV system at the input of UI-SPI in Matlab/Simulink.
Implementation and results demonstrate simplicity and accuracy, as
well as reliability of the model.
Abstract: The mathematical analysis on radiation obtained and
the development of the solar photovoltaic (PV) array groundwater
pumping is needed in the rural areas of Thohoyandou for sizing and
power performance subject to the climate conditions within the area.
A simple methodology approach is developed for the directed
coupled solar, controller and submersible ground water pump system.
The system consists of a PV array, pump controller and submerged
pump, battery backup and charger controller. For this reason, the
theoretical solar radiation is obtained for optimal predictions and
system performance in order to achieve different design and
operating parameters. Here the examination of the PV schematic
module in a Direct Current (DC) application is used for obtainable
maximum solar power energy for water pumping. In this paper, a
simple efficient photovoltaic water pumping system is presented with
its theoretical studies and mathematical modeling of photovoltaics
(PV) system.
Abstract: The assessment of the risk posed by a borrower to a
lender is one of the common problems that financial institutions have
to deal with. Consumers vying for a mortgage are generally
compared to each other by the use of a number called the Credit
Score, which is generated by applying a mathematical algorithm to
information in the applicant’s credit report. The higher the credit
score, the lower the risk posed by the candidate, and the better he is
to be taken on by the lender. The objective of the present work is to
use fuzzy logic and linguistic rules to create a model that generates
Credit Scores.
Abstract: This study focuses on the cooling of a photovoltaic
panel (PV). Indeed, the cooling improves the conversion capacity of
this one and maintains, under extreme conditions of air temperature,
the panel temperature at an appreciable level which avoids the
altering. To do this, a fan provides forced circulation of air. Because
the fan is supplied by the panel, it is necessary to determine the
optimum operating point that unites efficiency of the PV with the
consumption of the fan. For this matter, numerical simulations are
performed at varying mass flow rates of air, under two extreme air
temperatures (50°C, 25°C) and a fixed solar radiation (1000W.m2) in
a case of no wind.
Abstract: In development of floating photovoltaic generation
system, finding a suitable place of installation is as important as
development of economically feasible and stable structure. Especially
since floating photovoltaic system has its facility floating on water
surface, it is extremely important to review the effects of weather
conditions such as wind, water flow and floating matters, various
factors (such as fogs) that can reduce generation efficiency, possibility
of connection with power system, and legal restrictions. The method of
investigating suitable area and resource for development of
tracking-type floating photovoltaic generation system was proposed in
this paper, which can be used for development of floating and ocean
photovoltaic system in the future.
Abstract: The relationship between eigenstructure (eigenvalues
and eigenvectors) and latent structure (latent roots and latent vectors)
is established. In control theory eigenstructure is associated with
the state space description of a dynamic multi-variable system and
a latent structure is associated with its matrix fraction description.
Beginning with block controller and block observer state space forms
and moving on to any general state space form, we develop the
identities that relate eigenvectors and latent vectors in either direction.
Numerical examples illustrate this result. A brief discussion of the
potential of these identities in linear control system design follows.
Additionally, we present a consequent result: a quick and easy
method to solve the polynomial eigenvalue problem for regular matrix
polynomials.
Abstract: Analysis of real life problems often results in linear
systems of equations for which solutions are sought. The method to
employ depends, to some extent, on the properties of the coefficient
matrix. It is not always feasible to solve linear systems of equations
by direct methods, as such the need to use an iterative method
becomes imperative. Before an iterative method can be employed
to solve a linear system of equations there must be a guaranty that
the process of solution will converge. This guaranty, which must
be determined apriori, involve the use of some criterion expressible
in terms of the entries of the coefficient matrix. It is, therefore,
logical that the convergence criterion should depend implicitly on the
algebraic structure of such a method. However, in deference to this
view is the practice of conducting convergence analysis for Gauss-
Seidel iteration on a criterion formulated based on the algebraic
structure of Jacobi iteration. To remedy this anomaly, the Gauss-
Seidel iteration was studied for its algebraic structure and contrary
to the usual assumption, it was discovered that some property of the
iteration matrix of Gauss-Seidel method is only diagonally dominant
in its first row while the other rows do not satisfy diagonal dominance.
With the aid of this structure we herein fashion out an improved
version of Gauss-Seidel iteration with the prospect of enhancing
convergence and robustness of the method. A numerical section is
included to demonstrate the validity of the theoretical results obtained
for the improved Gauss-Seidel method.
Abstract: This paper presents the electrical effect of two neighboring distribution substation during the construction phase. The size of auxiliary grounding grid have an effect on entire grounding system. The bigger the size of auxiliary grounding grid, the lower the GPR and maximum touch voltage, with the exception that when the two grids are unconnected, i.e. the bigger the size of auxiliary grounding grid, the higher the maximum step voltage. The results in this paper could be served as design guideline of grounding system, and perhaps remedy of some troublesome grounding grids in power distribution’s system. Modeling and simulation is carried out on the Current Distribution Electromagnetic interference Grounding and Soil structure (CDEGS) program. The simulation results exhibit the design and analysis of power system grounding and perhaps could be set as a standard in grounding system design and modification in distribution substations.
Abstract: Partial shadowing is one of the problems that are always faced in terrestrial applications of solar photovoltaic (PV). The effects of partial shadow on the energy yield of conventional mono-crystalline and multi-crystalline PV modules have been researched for a long time. With deployment of new thin-film solar PV modules in the market, it is important to understand the performance of new PV modules operating under the partial shadow in the tropical zone. This paper addresses the impacts of different partial shadowing on the operating characteristics of four different types of solar PV modules that include multi-crystalline, amorphous thin-film, CdTe thin-film and CIGS thin-film PV modules.
Abstract: Most of the PV systems are designed with transformer for safety purpose with galvanic isolation. However, the transformer is big, heavy and expensive. Also, it reduces the overall frequency of the conversion stage. Generally PV inverter with transformer is having efficiency around 92%–94% only. To overcome these problems, transformerless PV system is introduced. It is smaller, lighter, cheaper and higher in efficiency. However, dangerous leakage current will flow between PV array and the grid due to the stray capacitance. There are different types of configurations available for transformerless inverters like H5, H6, HERIC, oH5, and Dual paralleled buck inverter. But each configuration is suffering from its own disadvantages like high conduction losses, shoot-through issues of switches, dead-time requirements at zero crossing instants of grid voltage to avoid grid shoot-through faults and MOSFET reverse recovery issues. The main objective of the proposed transformerless inverter is to address two key issues: One key issue for a transformerless inverter is that it is necessary to achieve high efficiency compared to other existing inverter topologies. Another key issue is that the inverter configuration should not have any shoot-through issues for higher reliability.
Abstract: Generally, distributed generation units refer to small-scale electric power generators that produce electricity at a site close to the customer or an electric distribution system (in parallel mode). From the customers’ point of view, a potentially lower cost, higher service reliability, high power quality, increased energy efficiency, and energy independence can be the key points of a proper DG unit. Moreover, the use of renewable types of distributed generations such as wind, photovoltaic, geothermal or hydroelectric power can also provide significant environmental benefits. Therefore, it is of crucial importance to study their impacts on the distribution networks. A marked increase in Distributed Generation (DG), associated with medium voltage distribution networks, may be expected. Nowadays, distribution networks are planned for unidirectional power flows that are peculiar to passive systems, and voltage control is carried out exclusively by varying the tap position of the HV/MV transformer. This paper will compare different DG control methods and possible network reconfiguration aimed at assessing their effect on voltage profiles.
Abstract: The coefficient diagram method is primarily an algebraic control design method whose objective is to easily obtain
a good controller with minimum user effort. As a matter of fact, if a
system model, in the form of linear differential equations, is known,
the user only need to define a time-constant and the controller order.
The later can be established regarding the expected disturbance type
via a lookup table first published by Koksal and Hamamci in 2004.
However an inaccuracy in this table was detected and pointed-out in
the present work. Moreover the above mentioned table was expanded
in order to enclose any k order type disturbance.
Abstract: The scope of this paper is to evaluate and compare the potential of LS-PV(Large Scale Photovoltaic Power Plant) power generation systems in the southern region of Libya at Al-Kufra for both stationary and tracking systems. A Microsoft Excel-VBA program has been developed to compute slope radiation, dew-point, sky temperature, and then cell temperature, maximum power output and module efficiency of the system for stationary system and for tracking system. The results for energy production show that the total energy output is 114GWh/year for stationary system and 148GWh/year for tracking system. The average module efficiency for the stationary system is 16.6% and 16.2% for the tracking system.
The values of electricity generation capacity factor (CF) and solar capacity factor (SCF) for stationary system were found to be 26% and 62.5% respectively and 34% and 82% for tracking system. The GCR (Ground Cover Ratio) for a stationary system is 0.7, which corresponds to a tilt angle of 24°. The GCR for tracking system was found to be 0.12. The estimated ground area needed to build a 50MW PV plant amounts to approx. 0.55km2 for a stationary PV field constituted by HIT PV arrays and approx. 91MW/ km2. In case of a tracker PV field, the required ground area amounts approx.2.4km2 and approx. 20.5MW/ km2.
Abstract: We installed solar panels and digital meteorological equipments whose electrical power is supplied using PV on July 13, 2011. Then, the relationship between the electric power generation and the irradiation, air temperature, and wind velocity was investigated on a roof at a university. The electrical power generation, irradiation, air temperature, and wind velocity were monitored over two years. By analyzing the measured meteorological data and electric power generation data using PTC, we calculated the size of the solar panel that is most suitable for this system. We also calculated the wasted power generation using PTC with the measured meteorological data obtained in this study. In conclusion, to reduce the "wasted power generation", a smaller-size solar panel is required for stable operation.
Abstract: In this paper, Semi-orthogonal B-spline scaling
functions and wavelets and their dual functions are presented
to approximate the solutions of integro-differential equations.The
B-spline scaling functions and wavelets, their properties and the
operational matrices of derivative for this function are presented to
reduce the solution of integro-differential equations to the solution of
algebraic equations. Here we compute B-spline scaling functions of
degree 4 and their dual, then we will show that by using them we have
better approximation results for the solution of integro-differential
equations in comparison with less degrees of scaling functions
Abstract: Utilizing solar energy in producing electricity can minimize environmental pollution generated by fossil fuel in producing electricity. Our research was base on the extraction of dye from Roystonea regia fruit by using methanol as solvent. The dye extracts were used as sensitizers in Dye-sensitized solar cell (DSSCs). Study was done on the electrical properties from the extracts of Roystonea regia fruit as Dye-sensitized solar cell (DSSCs). The absorptions of the extracts and extracts with dye were determined at different wavelengths (350-1000nm). Absorption peak was observed at 1.339 at wavelength 400nm. The obtained values for methanol extract Roystonea regia extract are, Imp = 0.015mA, Vmp = 12.0mV, fill factor = 0.763, Isc= 0.018 mA and Voc = 13.1 mV and efficiency of 0.32%. .The phytochemical screening was taken and it was observed that Roystonea regia extract contained less of anthocyanin compared to flavonoids. The nanostructured dye sensitized solar cell (DSSC) will provide economically credible alternative to present day silicon p–n junction photovoltaic.
Abstract: It is well known that photovoltaic (PV) cells are an attractive source of energy. Abundant and ubiquitous, this source is one of the important renewable energy sources that have been increasing worldwide year by year. However, in the V-P characteristic curve of GPV, there is a maximum point called the maximum power point (MPP) which depends closely on the variation of atmospheric conditions and the rotation of the earth. In fact, such characteristics outputs are nonlinear and change with variations of temperature and irradiation, so we need a controller named maximum power point tracker MPPT to extract the maximum power at the terminals of photovoltaic generator. In this context, the authors propose here to study the modeling of a photovoltaic system and to find an appropriate method for optimizing the operation of the PV generator using two intelligent controllers respectively to track this point. The first one is based on artificial neural networks and the second on fuzzy logic. After the conception and the integration of each controller in the global process, the performances are examined and compared through a series of simulation. These two controller have prove by their results good tracking of the MPPT compare with the other method which are proposed up to now.
Abstract: Temperature rising is a negative factor in almost all systems. It could cause by self heating or ambient temperature. In solar photovoltaic cells this temperature rising affects on the behavior of cells. The ability of a PV module to withstand the effects of periodic hot-spot heating that occurs when cells are operated under reverse biased conditions is closely related to the properties of the cell semi-conductor material.
In addition, the thermal effect also influences the estimation of the maximum power point (MPP) and electrical parameters for the PV modules, such as maximum output power, maximum conversion efficiency, internal efficiency, reliability, and lifetime. The cells junction temperature is a critical parameter that significantly affects the electrical characteristics of PV modules. For practical applications of PV modules, it is very important to accurately estimate the junction temperature of PV modules and analyze the thermal characteristics of the PV modules. Once the temperature variation is taken into account, we can then acquire a more accurate MPP for the PV modules, and the maximum utilization efficiency of the PV modules can also be further achieved.
In this paper, the three-Dimensional Transmission Line Matrix (3D-TLM) method was used to map the surface temperature distribution of solar cells while in the reverse bias mode. It was observed that some cells exhibited an inhomogeneity of the surface temperature resulting in localized heating (hot-spot). This hot-spot heating causes irreversible destruction of the solar cell structure. Hot spots can have a deleterious impact on the total solar modules if individual solar cells are heated. So, the results show clearly that the solar cells are capable of self-generating considerable amounts of heat that should be dissipated very quickly to increase PV module's lifetime.
Abstract: Some properties of Intuitionistic Fuzzy (IF) rough relational algebraic operators under an IF rough relational data model are investigated and illustrated using diabetes and heart disease databases. These properties are important and desirable for processing queries in an effective and efficient manner.
Abstract: This paper presents the optimal design and simulation of a grid-connected Photovoltaic (PV) system to supply electric power to meet the energy demand by Electrical Department in University of Tripoli Libya. Solar radiation is the key factor determining electricity produced by photovoltaic (PV) systems. This paper is designed to develop a novel method to calculate the solar photovoltaic generation capacity on the basis of Mean Global Solar Radiation data available for Tripoli Libya and finally develop a system design of possible plant capacity for the available roof area. MatLab/Simulink Programming tools and monthly average solar radiation data are used for this design and simulation. The specifications of equipments are provided based on the availability of the components in the market. Simulation results and analyses are presented to validate the proposed system configuration.