Abstract: In this paper the Laplace Decomposition method is developed to solve linear and nonlinear fractional integro- differential equations of Volterra type.The fractional derivative is described in the Caputo sense.The Laplace decomposition method is found to be fast and accurate.Illustrative examples are included to demonstrate the validity and applicability of presented technique and comparasion is made with exacting results.
Abstract: Nowadays, quasi-continuous wave diode lasers are
used in a widespread variety of applications. Temperature effects in
these lasers can strongly influence their performance. In this paper,
the effects of temperature have been experimentally investigated on
different features of a 60W-QCW diode laser. The obtained results
indicate that the conversion efficiency and operation voltage of diode
laser decrease with the augmentation of the working temperature
associated with a redshift in the laser peak wavelength. Experimental
results show the emission peak wavelength of laser shifts 0.26 nm
and the conversion efficiency decreases 1.76 % with the increase of
temperature from 40 to 50 ̊C. Present study also shows the slope
efficiency decreases gradually at low temperatures and rapidly at
higher temperatures. Regarding the close dependence of the
mentioned parameters to the operating temperature, it is of great
importance to carefully control the working temperature of diode
laser, particularly for medical applications.
Abstract: In this paper, the test purpose will be to assess
whether or not the accelerated model proposed by Eyring will be able
to translate results for the shape and scale parameters of an
underlying Weibull model, obtained under two accelerating using
conditions, to expected normal using condition results for these
parameters. The product being analyzed is a new type of insulate
fluid, and the accelerating factor is the voltage stresses applied to the
fluid at two different levels (30KV and 40KV). The normal operating
voltage is 25KV. In this case, it was possible to test the insulate fluid
at normal voltage using condition. Both results for the two
parameters of the Weibull model, obtained under normal using
condition and translated from accelerated using conditions to normal
conditions, will be compared to each other to assess the accuracy of
the Eyring model when the accelerating factor is only the voltage
stress.
Abstract: In this paper, the computation of the electrical field distribution around AC high-voltage lines is demonstrated. The advantages and disadvantages of two different methods are described to evaluate the electrical field quantity. The first method is a seminumerical method using the laws of electrostatic techniques to simulate the two-dimensional electric field under the high-voltage overhead line. The second method which will be discussed is the finite element method (FEM) using specific boundary conditions to compute the two- dimensional electric field distributions in an efficient way.
Abstract: This paper presents the experimental results on effect of applied voltage stress frequency to the occurrence of electrical treeing in 22 kV cross linked polyethylene (XLPE) insulated cable.Hallow disk of XLPE insulating material with thickness 5 mm taken from unused high voltage cable was used as the specimen in this study. Stainless steel needle was inserted gradually into the specimen to give a tip to earth plane electrode separation of 2.50.2 mm at elevated temperature 105-110°C. The specimen was then annealed for 5 minute to minimize any mechanical stress build up around the needle-plane region before it was cooled down to room temperature. Each specimen were subjected to the same applied voltage stress level at 8 kV AC rms, with various frequency, 50, 100, 500, 1000 and 2000 Hz. Initiation time, propagation speed and pattern of electrical treeing were examined in order to study the effect of applied voltage stress frequency. By the experimental results, initial time of visible treeing decreases with increasing in applied voltage frequency. Also, obviously, propagation speed of electrical treeing increases with increasing in applied voltage frequency.Furthermore, two types of electrical treeing, bush-like and branch-like treeing were observed.The experimental results confirmed the effect of voltage stress frequency as well.
Abstract: This paper presents features that characterize power
quality disturbances from recorded voltage waveforms using wavelet
transform. The discrete wavelet transform has been used to detect
and analyze power quality disturbances. The disturbances of interest
include sag, swell, outage and transient. A power system network has
been simulated by Electromagnetic Transients Program. Voltage
waveforms at strategic points have been obtained for analysis, which
includes different power quality disturbances. Then wavelet has been
chosen to perform feature extraction. The outputs of the feature
extraction are the wavelet coefficients representing the power quality
disturbance signal. Wavelet coefficients at different levels reveal the
time localizing information about the variation of the signal.
Abstract: This paper presented a MATLAB-based system named Smart Access Network Testing, Analyzing and Database (SANTAD), purposely for in-service transmission surveillance and self restoration against fiber fault in fiber-to-the-home (FTTH) access network. The developed program will be installed with optical line terminal (OLT) at central office (CO) to monitor the status and detect any fiber fault that occurs in FTTH downwardly from CO towards residential customer locations. SANTAD is interfaced with optical time domain reflectometer (OTDR) to accumulate every network testing result to be displayed on a single computer screen for further analysis. This program will identify and present the parameters of each optical fiber line such as the line's status either in working or nonworking condition, magnitude of decreasing at each point, failure location, and other details as shown in the OTDR's screen. The failure status will be delivered to field engineers for promptly actions, meanwhile the failure line will be diverted to protection line to ensure the traffic flow continuously. This approach has a bright prospect to improve the survivability and reliability as well as increase the efficiency and monitoring capabilities in FTTH.
Abstract: Solar energy has a major role in renewable energy
resources. Solar Cell as a basement of solar system has attracted lots
of research. To conduct a study about solar energy system, an
authenticated model is required. Diode base PV models are widely
used by researchers. These models are classified based on the number
of diodes used in them. Single and two-diode models are well
studied. Single-diode models may have two, three or four elements.
In this study, these solar cell models are examined and the simulation
results are compared to each other. All PV models are re-designed in
the Matlab/Simulink software and they examined by certain test
conditions and parameters. This paper provides comparative studies
of these models and it tries to compare the simulation results with
manufacturer-s data sheet to investigate model validity and accuracy.
The results show a four- element single-diode model is accurate and
has moderate complexity in contrast to the two-diode model with
higher complexity and accuracy
Abstract: In this paper, a heuristic method for simultaneous
rescue robot path-planning and mission scheduling is introduced
based on project management techniques, multi criteria decision
making and artificial potential fields path-planning. Groups of
injured people are trapped in a disastrous situation. These people are
categorized into several groups based on the severity of their
situation. A rescue robot, whose ultimate objective is reaching
injured groups and providing preliminary aid for them through a path
with minimum risk, has to perform certain tasks on its way towards
targets before the arrival of rescue team. A decision value is assigned
to each target based on the whole degree of satisfaction of the criteria
and duties of the robot toward the target and the importance of
rescuing each target based on their category and the number of
injured people. The resulted decision value defines the strength of the
attractive potential field of each target. Dangerous environmental
parameters are defined as obstacles whose risk determines the
strength of the repulsive potential field of each obstacle. Moreover,
negative and positive energies are assigned to the targets and
obstacles, which are variable with respects to the factors involved.
The simulation results show that the generated path for two cases
studies with certain differences in environmental conditions and
other risk factors differ considerably.
Abstract: In this paper, a novel wave equation for electromagnetic
waves in a medium having anisotropic permittivity has been derived
with the help of Maxwell-s curl equations. The x and y components
of the Maxwell-s equations are written with the permittivity () being
a 3 × 3 symmetric matrix. These equations are solved for Ex , Ey,
Hx, Hy in terms of Ez, Hz, and the partial derivatives. The Z
components of the Maxwell-s curl are then used to arrive to the
generalized Helmholtz equations for Ez and Hz.
Abstract: In this paper the fatigue crack initiation location of double shear lap joints, treated by interference fit and bolt clamping, have been investigated both experimentally and numerically. To do so, using the fracture section of available fatigue tested specimens of interference fitted and torque tightened Aluminum 2024-T3 plates, the crack initiation location was determined. The stress distribution attained from the finite element analysis was used to help explain the results observed in the experimental tests. The results showed that the fatigue crack initiation location changes from top and mid plane at the hole edge to somewhere far from the hole edge (stress concentration region) in different combination of clamping force, interference fit size and applied cyclic load ranges. It is worth mentioning that the fatigue crack initiation location affects the fatigue life of the specimens too.
Abstract: Multi-energy systems will enhance the system
reliability and power quality. This paper presents an integrated
approach for the design and operation of distributed energy resources
(DER) systems, based on energy hub modeling. A multi-objective
optimization model is developed by considering an integrated view of
electricity and natural gas network to analyze the optimal design and
operating condition of DER systems, by considering two conflicting
objectives, namely, minimization of total cost and the minimization
of environmental impact which is assessed in terms of CO2
emissions. The mathematical model considers energy demands of the
site, local climate data, and utility tariff structure, as well as technical
and financial characteristics of the candidate DER technologies. To
provide energy demands, energy systems including photovoltaic, and
co-generation systems, boiler, central power grid are considered. As
an illustrative example, a hotel in Iran demonstrates potential
applications of the proposed method. The results prove that
increasing the satisfaction degree of environmental objective leads to
increased total cost.
Abstract: The purpose of this paper is to improve electromagnetic characteristics on grounding grid by applying the conductive concrete. The conductive concrete in this study is under an extra high voltage (EHV, 345kV) system located in a high-tech industrial park or science park. Instead of surrounding soil of grounding grid, the application of conductive concrete can reduce equipment damage and body damage caused by switching surges. The focus of the two cases on the EHV distribution system in a high-tech industrial park is presented to analyze four soil material styles. By comparing several soil material styles, the study results have shown that the conductive concrete can effectively reduce the negative damages caused by electromagnetic transient. The adoption of the style of grounding grid located 1.0 (m) underground and conductive concrete located from the ground surface to 1.25 (m) underground can obviously improve the electromagnetic characteristics so as to advance protective efficiency.
Abstract: In this paper we propose the study of a centrifugal pump control system driven by a three-phase induction motor, which is supplied by a PhotoVoltaic PV generator. The system includes solar panel, a DC / DC converter equipped with its MPPT control, a voltage inverter to three-phase Pulse Width Modulation - PWM and a centrifugal pump driven by a three phase induction motor. In order to control the flow of the centrifugal pump, a Direct Torque Control - DTC of the induction machine is used. To illustrate the performances of the control, simulation results are carried out using Matlab/Simulink.
Abstract: This research aims to create a model for analysis of student motivation behavior on e-Learning based on association rule mining techniques in case of the Information Technology for Communication and Learning Course at Suan Sunandha Rajabhat University. The model was created under association rules, one of the data mining techniques with minimum confidence. The results showed that the student motivation behavior model by using association rule technique can indicate the important variables that influence the student motivation behavior on e-Learning.
Abstract: This study describes analysis of tower grounding
resistance effected the back flashover voltage across insulator string
in a transmission system. This paper studies the 500 kV transmission
lines from Mae Moh, Lampang to Nong Chok, Bangkok, Thailand,
which is double circuit in the same steel tower with two overhead
ground wires. The factor of this study includes magnitude of
lightning stroke, and front time of lightning stroke. Steel tower uses
multistory tower model. The assumption of studies based on the
return stroke current ranged 1-200 kA, front time of lightning stroke
between 1 μs to 3 μs. The simulations study the effect of varying
tower grounding resistance that affect the lightning current.
Simulation results are analyzed lightning over voltage that causes
back flashover at insulator strings. This study helps to know causes
of problems of back flashover the transmission line system, and also
be as a guideline solving the problem for 500 kV transmission line
systems, as well.
Abstract: Static synchronous compensator (STATCOM) is a shunt connected voltage source converter (VSC), which can affect rapid control of reactive flow in the transmission line by controlling the generated a.c. voltage. The main aim of the paper is to design a power system installed with a Static synchronous compensator (STATCOM) and demonstrates the application of the linearised Phillips-heffron model in analyzing the damping effect of the STATCOM to improve power system oscillation stability. The proposed PI controller is designed to coordinate two control inputs: Voltage of the injection bus and capacitor voltage of the STATCOM, to improve the Dynamic stability of a SMIB system .The power oscillations damping (POD) control and power system stabilizer (PSS) and their coordinated action with proposed controllers are tested. The simulation result shows that the proposed damping controllers provide satisfactory performance in terms of improvements of dynamic stability of the system.
Abstract: Worldwide many electrical equipment insulation
failures have been reported caused by switching operations, while
those equipments had previously passed all the standard tests and
complied with all quality requirements. The problem is mostly
associated with high-frequency overvoltages generated during
opening or closing of a switching device. The transients generated
during switching operations in a Gas Insulated Substation (GIS) are
associated with high frequency components in the order of few tens
of MHz.
The frequency spectrum of the VFTO generated in the 220/66 kV
Wadi-Hoff GIS is analyzed using Fast Fourier Transform technique.
The main frequency with high voltage amplitude due to the operation
of disconnector (DS5) is 5 to 10 MHz, with the highest amplitude at 9
MHz. The main frequency with high voltage amplitude due to the
operation of circuit breaker (CB5) is 1 to 25 MHz, with the highest
amplitude at 2 MHz.
Mitigating techniques damped the oscillating frequencies
effectively. The using of cable terminal reduced the frequency
oscillation effectively than that of OHTL terminal. The using of a
shunt capacitance results in vanishing the high frequency
components. Ferrite rings reduces the high frequency components
effectively especially in the range 2 to 7 MHz. The using of RC and
RL filters results in vanishing the high frequency components.
Abstract: Individually Network reconfiguration or Capacitor control
perform well in minimizing power loss and improving voltage
profile of the distribution system. But for heavy reactive power loads
network reconfiguration and for heavy active power loads capacitor
placement can not effectively reduce power loss and enhance
voltage profiles in the system. In this paper, an hybrid approach
that combine network reconfiguration and capacitor placement using
Harmony Search Algorithm (HSA) is proposed to minimize power
loss reduction and improve voltage profile. The proposed approach
is tested on standard IEEE 33 and 16 bus systems. Computational
results show that the proposed hybrid approach can minimize losses
more efficiently than Network reconfiguration or Capacitor control.
The results of proposed method are also compared with results
obtained by Simulated Annealing (SA). The proposed method has
outperformed in terms of the quality of solution compared to SA.
Abstract: This paper presented a new approach for centralized
monitoring and self-protected against fiber fault in fiber-to-the-home
(FTTH) access network by using Smart Access Network Testing,
Analyzing and Database (SANTAD). SANTAD will be installed
with optical line terminal (OLT) at central office (CO) for in-service
transmission surveillance and fiber fault localization within FTTH
with point-to-multipoint (P2MP) configuration downwardly from CO
towards customer residential locations based on the graphical user
interface (GUI) processing capabilities of MATLAB software.
SANTAD is able to detect any fiber fault as well as identify the
failure location in the network system. SANTAD enable the status of
each optical network unit (ONU) connected line is displayed onto
one screen with capability to configure the attenuation and detect the
failure simultaneously. The analysis results and information will be
delivered to the field engineer for promptly actions, meanwhile the
failure line will be diverted to protection line to ensure the traffic
flow continuously. This approach has a bright prospect to improve
the survivability and reliability as well as increase the efficiency and
monitoring capabilities in FTTH.