Abstract: Adjacent Hall microsensors, comprising a silicon
substrate and four contacts, providing simultaneously two supply inputs and two differential outputs, are characterized. The voltage
related sensitivity is in the order of 0.11T-1, and a cancellation method for offset compensation is used, achieving residual offset in
the micro scale which is also compared to a single Hall plate.
Abstract: Recently, the issue of machine condition monitoring
and fault diagnosis as a part of maintenance system became global
due to the potential advantages to be gained from reduced
maintenance costs, improved productivity and increased machine
availability. The aim of this work is to investigate the effectiveness
of a new fault diagnosis method based on power spectral density
(PSD) of vibration signals in combination with decision trees and
fuzzy inference system (FIS). To this end, a series of studies was
conducted on an external gear hydraulic pump. After a test under
normal condition, a number of different machine defect conditions
were introduced for three working levels of pump speed (1000, 1500,
and 2000 rpm), corresponding to (i) Journal-bearing with inner face
wear (BIFW), (ii) Gear with tooth face wear (GTFW), and (iii)
Journal-bearing with inner face wear plus Gear with tooth face wear
(B&GW). The features of PSD values of vibration signal were
extracted using descriptive statistical parameters. J48 algorithm is
used as a feature selection procedure to select pertinent features from
data set. The output of J48 algorithm was employed to produce the
crisp if-then rule and membership function sets. The structure of FIS
classifier was then defined based on the crisp sets. In order to
evaluate the proposed PSD-J48-FIS model, the data sets obtained
from vibration signals of the pump were used. Results showed that
the total classification accuracy for 1000, 1500, and 2000 rpm
conditions were 96.42%, 100%, and 96.42% respectively. The results
indicate that the combined PSD-J48-FIS model has the potential for
fault diagnosis of hydraulic pumps.
Abstract: A study was conducted to formally characterize
notebook computer performance under various environmental and
usage conditions. Software was developed to collect data from the
operating system of the computer. An experiment was conducted to
evaluate the performance parameters- variations, trends, and
correlations, as well as the extreme value they can attain in various
usage and environmental conditions. An automated software script
was written to simulate user activity. The variability of each
performance parameter was addressed by establishing the empirical
relationship between performance parameters. These equations were
presented as baseline estimates for performance parameters, which
can be used to detect system deviations from normal operation and
for prognostic assessment. The effect of environmental factors,
including different power sources, ambient temperatures, humidity,
and usage, on performance parameters of notebooks was studied.
Abstract: Reno-pin contact test is a method that is controlled by
DC motor used to characterize electronic chips. This method is used in
electronic and telecommunication devices. A new electric
performance testing system is developed in which the testing method
is controlled by using Piezoelectric Transducer (PZT) instead of DC
motor which reduces vibration and noise. The vertical displacement of
the Reno-pin is very short in the Reno-pin contact testing system. Now
using a flexible guide in the new Reno-pin contact system, the vertical
movement of the Reno-pin is increased many times of the existing
Reno-pin contact testing method using DC motor. Using the present
electric performance testing system with a flexible hinge and PZT
instead of DC motor, manufacturing of electronic chips are able to
characterize chips with low cost and high speed.
Abstract: Analytically the effect of polarization dependent loss on a high speed fiber optic communication link has been investigated. PDL and the signal's incoming state of polarization (SOP) have a significant co-relation between them and their various combinations produces different effects on the system behavior which has been inspected. Pauli's spin operator and PDL parameters are combined together to observe the attenuation effect induced by PDL in a link containing multiple PDL elements. It is found that in the presence of PDL the Q-factor and BER at the receiver undergoes fluctuation causing the system to be unstable and results show that it is mainly due to optical-signal-to-parallel-noise ratio (OSNItpar) that these parameters fluctuate. Generally the Q-factor, BER deteriorates as the value of average PDL in the link increases except for depolarized light for which the system parameters improves when PDL increases.
Abstract: We developed a vision interface immersive projection system, CAVE in virtual rea using hand gesture recognition with computer vis background image was subtracted from current webcam and we convert the color space of the imag Then we mask skin regions using skin color range t a noise reduction operation. We made blobs fro gestures were recognized using these blobs. Using recognition, we could implement an effective bothering devices for CAVE. e framework for an reality research field vision techniques. ent image frame age into HSV space. e threshold and apply from the image and ing our hand gesture e interface without
Abstract: A biocompatible ferrofluid have been prepared by coprecipitation
of FeCl2.4H2O and FeCl3.6H2O under ultrasonic
irradiation and with NaOH as alkaline agent. Cystein was also used
as capping agent in the solution. Magnetic properties of the produced
ferrofluid were then determined by VSM test and magnetite
nanoparticles were characterized by XRD and TEM techniques. The
effect of surfactant to Fe ion weight ratio was also studied during this
project by using two different amount of Dextran. Results showed the
presence of a biocompatible superparamagnetic ferrofluid including
magnetite nanoparticles with particle size ranging under 20 nm. The
increase in the surfactant content results in the narrowing of the size
distribution and reduction of the particle size and more solution
stability.
Abstract: A novel biologically inspired controller for the autonomous
navigation of a mobile robot in an evasion task is
proposed. The controller takes advantage of the environment by
calculating a measure of danger and subsequently choosing the
parameters of a reinforcement learning based decision process.
Two different reinforcement learning algorithms were used: Qlearning
and Sarsa (λ). Simulations show that selecting dynamic
parameters reduce the time while executing the decision making
process, so the robot can obtain a policy to succeed in an escaping
task in a realistic time.
Abstract: This paper presents the mathematical model and
control strategy on DQ frame of shunt active power filter. The
structure of the shunt active power filter is the voltage source inverter
(VSI). The pulse width modulation (PWM) with PI controller is used
in the paper. The concept of DQ frame to apply with the shunt active
power filter is described. Moreover, the detail of the PI controller
design for two current loops and one voltage loop are fully explained.
The DQ axis with Fourier (DQF) method is applied to calculate the
reference currents on DQ frame. The simulation results show that the
control strategy and the design method presented in the paper can
provide the good performance of the shunt active power filter.
Moreover, the %THD of the source currents after compensation can
follow the IEEE Std.519-1992.
Abstract: The purpose of this research is to increase our
knowledge as regards how Small-and-Medium-Sized Enterprises
(SMEs) tackle ERP implementation projects to achieve successful
adoption and use of these systems within the organization. SMEs
have scare resources to handle these kinds of projects which have
proved to be risky and costly. There are several studies focusing on
ERP implementation in larger companies, however, few studies
report on challenges experienced by SMEs. Our research seeks to
bridge this gap. Through a multiple case study of four companies, we
identified challenges and critical elements within the different phases
(pre-implementation, implementation and post-implementation) of
the ERP life cycle. To interpret our findings, we utilize a well-know
ERP life cycle model and critical success factors developed for larger
companies which are reported in former research literature. We
discuss if these models are relevant for SMEs and suggest additional
critical elements identified in this study to make a framework more
adapted to the SME context.
Abstract: The importance of our country-s communication
system is noticeable when a disaster occurs. The communication
system in our country includes wired and wireless telephone
networks, radio, satellite system and more increasingly internet. Even
though our communication system is most extensive and dependable,
extreme conditions can put a strain on them. Interoperability between
heterogeneous wireless networks can be used to provide efficient
communication for emergency first response. IEEE 802.21 specifies
Media Independent Handover (MIH) services to enhance the mobile
user experience by optimizing handovers between heterogeneous
access networks. This paper presents an algorithm to improve
congestion control in MIH framework. It is analytically shown that
by including time factor in network selection we can optimize
congestion in the network.
Abstract: The present work deals with analyses of the effects
of bearing curvature and non-Newtonian characteristics on the load capacity of an exponential rectangular squeeze film bearing using
Bingham fluids as lubricants. Bingham fluids are characterized by an
yield value and hence the formation of a “rigid" core in the region
between the plates is justified. The flow is confined to the region
between the core and the plates. The shape of the core has been
identified through numerical means. Further, numerical solutions for
the pressure distribution and load carrying capacity of the bearing
for various values of Bingham number and curvature parameter have
been obtained. The effects of bearing curvature and non-Newtonian
characteristics of the lubricant on the bearing performances have been
discussed.
Abstract: This article is focused on the calculation of heat
radiation intensity and its optimization on an aluminum mould
surface. The inside of the mould is sprinkled with a special powder
and its outside is heated by infra heaters located above the mould
surface, up to a temperature of 250°C. By this way artificial leathers
in the car industry are produced (e. g. the artificial leather on a car
dashboard). A mathematical model of heat radiation of infra heaters
on a mould surface is described in this paper. This model allows us to
calculate a heat-intensity radiation on the mould surface for the
concrete location of infra heaters above the mould surface. It is
necessary to ensure approximately the same heat intensity radiation
on the mould surface by finding a suitable location for the infra
heaters, and in this way the same material structure and color of
artificial leather. In the model we have used a genetic algorithm to
optimize the radiation intensity on the mould surface. Experimental
measured values for the heat radiation intensity by a sensor in the
surroundings of an infra heater are used for the calculation
procedures. A computational procedure was programmed in language
Matlab.
Abstract: Distributed Power generation has gained a lot of
attention in recent times due to constraints associated with
conventional power generation and new advancements in DG
technologies .The need to operate the power system economically
and with optimum levels of reliability has further led to an increase
in interest in Distributed Generation. However it is important to place
Distributed Generator on an optimum location so that the purpose of
loss minimization and voltage regulation is dully served on the
feeder. This paper investigates the impact of DG units installation on
electric losses, reliability and voltage profile of distribution networks.
In this paper, our aim would be to find optimal distributed
generation allocation for loss reduction subjected to constraint of
voltage regulation in distribution network. The system is further
analyzed for increased levels of Reliability. Distributed Generator
offers the additional advantage of increase in reliability levels as
suggested by the improvements in various reliability indices such as
SAIDI, CAIDI and AENS. Comparative studies are performed and
related results are addressed. An analytical technique is used in order
to find the optimal location of Distributed Generator. The suggested
technique is programmed under MATLAB software. The results
clearly indicate that DG can reduce the electrical line loss while
simultaneously improving the reliability of the system.
Abstract: The power transformer is the most expensive, indispensable and arguably the most important equipment item in a power system Insulation failure in transformers can cause long term interruption to supply and loss of revenue and the condition assessment of the insulation is thus an important maintenance procedure. Oil-impregnated transformer insulation consists of mainly organic materials including mineral oil and cellulose-base paper and pressboard. The operating life of cellulose-based insulation, as with most organic insulation, depends heavily on its operating temperature rise above ambient. This paper reports results of a laboratory-based experimental investigation of partial discharge (PD) activity at high temperature in oil-impregnated insulation. The experiments reported here are part an on-going programme aimed at investigating the way in which insulation deterioration can be monitored and quantified by use of partial discharge diagnostics. Partial discharge patterns were recorded and analysed during increasing and decreasing phases of the temperature. The effect of ageing of the insulation on the PD patterns in oil and oil-impregnated insulation are also considered.
Abstract: To maximise furnace production it-s necessary to
optimise furnace control, with the objectives of achieving maximum
power input into the melting process, minimum network distortion
and power-off time, without compromise on quality and safety. This
can be achieved with on the one hand by an appropriate electrode
control and on the other hand by a minimum of AC transformer
switching.
Electrical arc is a stochastic process; witch is the principal cause
of power quality problems, including voltages dips, harmonic
distortion, unbalance loads and flicker. So it is difficult to make an
appropriate model for an Electrical Arc Furnace (EAF). The factors
that effect EAF operation are the melting or refining materials,
melting stage, electrode position (arc length), electrode arm control
and short circuit power of the feeder. So arc voltages, current and
power are defined as a nonlinear function of the arc length. In this
article we propose our own empirical function of the EAF and model,
for the mean stages of the melting process, thanks to the
measurements in the steel factory.
Abstract: The range of the output power is a very important and evident limitation of two-level inverters. In order to overcome this disadvantage, multilevel inverters are introduced. Recently, Cascade H-Bridge inverters have emerged as one of the popular converter topologies used in numerous industrial applications. The modulation switching strategies such as phase shifted carrier based Pulse Width Modulation (PWM) technique and Stair case modulation with Selective Harmonic Elimination (SHE) PWM technique are generally used. NR method is used to solve highly non linear transcendental equations which are formed by SHEPWM method. Generally NR method has a drawback of requiring good initial guess but in this paper a new approach is implemented for NR method with any random initial guess. A three phase CHB 11-level inverter is chosen for analysis. MATLAB/SIMULINK programming environment and harmonic profiles are compared. Finally this paper presents a method at fundamental switching frequency with least % THDV.
Abstract: In this study, in order to clarify wind-induced
phenomena, especially vertical mixing of density stratification in a
closed water area with floating-leaved plants, we conducted hydraulic
experiments on wind flow characteristics, wind wave characteristics,
entrainment phenomena and turbulent structure by using a wind tunnel
test tank and simulated floating-leaved plants. From the experimental
results of wind flow and wind wave characteristics, we quantified the
impact of the occupancy rate of the plants on their resistance
characteristics. From the experimental results of entrainment
phenomena, we defined the parameter that could explain the
magnitude of mixing between the density stratifications, and
quantified the impact of the occupancy rate on vertical mixing
between stratifications. From the experimental results of the turbulent
structure of the upper layer, we clarified the differences in small-scale
turbulence components at each occupancy rate and quantified the
impact of the occupancy rate on the turbulence characteristics. For a
summary of this study, we theoretically quantified wind-induced
entrainment phenomena in a closed water area with luxuriant growth
of floating-leaved plants. The results indicated that the impact of
luxuriant growth of floating-leaved plants in a closed water body
could be seen in the difference in small-scale fluid characteristics, and
these characteristics could be expressed using the small-scale
turbulent components.
Abstract: A high performance clarification system has been
discussed for advanced aqueous reprocessing of FBR spent fuel.
Dissolver residue gives the cause of troubles on the plant operation of
reprocessing. In this study, the new clarification system based on the
hybrid of centrifuge and filtration was proposed to get the high
separation ability of the component of whole insoluble sludge. The
clarification tests of simulated solid species were carried out to
evaluate the clarification performance using small-scale test apparatus
of centrifuge and filter unit. The density effect of solid species on the
collection efficiency was mainly evaluated in the centrifugal
clarification test. In the filtration test using ceramic filter with pore
size of 0.2μm, on the other hand, permeability and filtration rate
were evaluated in addition to the filtration efficiency. As results, it was
evaluated that the collection efficiency of solid species on the new
clarification system was estimated as nearly 100%. In conclusion, the
high clarification performance of dissolver liquor can be achieved by
the hybrid of the centrifuge and filtration system.
Abstract: A zero dimensional model has been used to investigate
the combustion performance of a single cylinder direct injection
diesel engine fueled by biofuels with options like supercharging and
exhaust gas recirculation. The numerical simulation was performed at
constant speed. The indicated pressure, temperature diagrams are
plotted and compared for different fuels. The emissions of soot and
nitrous oxide are computed with phenomenological models. The
experimental work was also carried out with biodiesel (palm stearin
methyl ester) diesel blends, ethanol diesel blends to validate
simulation results with experimental results, and observed that the
present model is successful in predicting the engine performance with
biofuels.