Abstract: This paper presents a low-voltage low-power differential linear transconductor with near rail-to-rail input swing. Based on the current-mirror OTA topology, the proposed transconductor combines the Flipped Voltage Follower (FVF) technique to linearize the transconductor behavior that leads to class- AB linear operation and the virtual transistor technique to lower the effective threshold voltages of the transistors which offers an advantage in terms of low supply requirement. Design of the OTA has been discussed. It operates at supply voltages of about ±0.8V. Simulation results for 0.18μm TSMC CMOS technology show a good input range of 1Vpp with a high DC gain of 81.53dB and a total harmonic distortion of -40dB at 1MHz for an input of 1Vpp. The main aim of this paper is to present and compare new OTA design with high transconductance, which has a potential to be used in low voltage applications.
Abstract: Power Factor (PF) is one of the most important parameters in the electrical systems, especially in the water pumping station. The low power factor value of the water pumping stations causes penalty for the electrical bill. There are many methods use for power factor improvement. Each one of them uses a capacitor on the electrical power network. The position of the capacitors is varied depends on many factors such as; voltage level and capacitors rating. Adding capacitors on the motor terminals increase the supply power factor from 0.8 to more than 0.9 but these capacitors cause some problems for the electrical grid network, such as increasing the harmonic contents of the grid line voltage. In this paper the effects of using capacitors in the water pumping stations to improve the power factor value on the harmonic contents of the electrical grid network are studied. One of large water pumping stations in Kafr El-Shikh Governorate in Egypt was used, as a case study. The effect of capacitors on the line voltage harmonic contents is measured. The station uses capacitors to improve the PF values at the 1 lkv grid network. The power supply harmonics values are measured by a power quality analyzer at different loading conditions. The results showed that; the capacitors improved the power factor value of the feeder and its value increased than 0.9. But the THD values are increased by adding these capacitors. The harmonic analysis showed that; the 13th, 17th, and 19th harmonics orders are increased also by adding the capacitors.
Abstract: This paper describes a 2.4 GHz passive switch mixer
and a 5/2.5 GHz voltage-controlled negative Gm oscillator (VCO)
with an inversion-mode MOS varactor. Both circuits are implemented
using a 1P8M 0.13 μm process. The switch mixer has an input
referred 1 dB compression point of -3.89 dBm and a conversion
gain of -0.96 dB when the local oscillator power is +2.5 dBm.
The VCO consumes only 1.75 mW, while drawing 1.45 mA from a
1.2 V supply voltage. In order to reduce the passives size, the VCO
natural oscillation frequency is 5 GHz. A clocked CMOS divideby-
two circuit is used for frequency division and quadrature phase
generation. The VCO has a -109 dBc/Hz phase noise at 1 MHz
frequency offset and a 2.35-2.5 GHz tuning range (after the frequency
division), thus complying with ZigBee requirements.
Abstract: A measurement system was successfully fabricated to
detect ion concentrations (hydrogen and chlorine) in this study.
PIC18F4520, the microcontroller was used as the control unit in the
measurement system. The measurement system was practically used
to sense the H+ and Cl- in different examples, and the pH and pCl
values were exhibited on real-time LCD display promptly. In the study,
the measurement method is used to judge whether the response voltage
is stable. The change quantity is smaller than 0.01%, that the present
response voltage compares with next response voltage for H+
measurement, and the above condition is established only 6 sec.
Besides, the change quantity is smaller than 0.01%, that the present
response voltage compares with next response voltage for Clmeasurement,
and the above condition is established only 5 sec.
Furthermore, the average error quantities would also be considered,
and they are 0.05 and 0.07 for measurements of pH and pCl values,
respectively.
Abstract: In this paper, a direct torque control - space vector
modulation (DTC-SVM) scheme is presented for a six-phase speed
and voltage sensorless induction motor (IM) drive. The decoupled
torque and stator flux control is achieved based on IM stator flux field orientation. The rotor speed is detected by on-line estimating of
the rotor angular slip speed and stator vector flux speed. In addition, a simple method is introduced to estimate the stator resistance.
Moreover in this control scheme the voltage sensors are eliminated
and actual motor phase voltages are approximated by using PWM
inverter switching times and the dc link voltage. Finally, some simulation and experimental results are presented to verify the
effectiveness and capability of the proposed control scheme.
Abstract: In this paper, we analyze and test a scheme for the
estimation of electrical fundamental frequency signals from the
harmonic load current and voltage signals.
The scheme was based on using two different Multi Layer
Artificial Neural Networks (ML-ANN) one for the current and the
other for the voltage.
This study also analyzes and tests the effect of choosing the
optimum artificial neural networks- sizes which determine the quality
and accuracy of the estimation of electrical fundamental frequency
signals.
The simulink tool box of the Matlab program for the simulation of
the test system and the test of the neural networks has been used.
Abstract: This paper describes the design of a voltage based maximum power point tracker (MPPT) for photovoltaic (PV) applications. Of the various MPPT methods, the voltage based method is considered to be the simplest and cost effective. The major disadvantage of this method is that the PV array is disconnected from the load for the sampling of its open circuit voltage, which inevitably results in power loss. Another disadvantage, in case of rapid irradiance variation, is that if the duration between two successive samplings, called the sampling period, is too long there is a considerable loss. This is because the output voltage of the PV array follows the unchanged reference during one sampling period. Once a maximum power point (MPP) is tracked and a change in irradiation occurs between two successive samplings, then the new MPP is not tracked until the next sampling of the PV array voltage. This paper proposes an MPPT circuit in which the sampling interval of the PV array voltage, and the sampling period have been shortened. The sample and hold circuit has also been simplified. The proposed circuit does not utilize a microcontroller or a digital signal processor and is thus suitable for low cost and low power applications.
Abstract: This paper proposes two types of non-isolated
direct AC-DC converters. First, it shows a buck-boost
converter with an H-bridge, which requires few components
(three switches, two diodes, one inductor and one capacitor) to
convert AC input to DC output directly. This circuit can handle
a wide range of output voltage. Second, a direct AC-DC buck
converter is proposed for lower output voltage applications.
This circuit is analyzed with output voltage of 12V. We
describe circuit topologies, operation principles and simulation
results for both circuits.
Abstract: Design of Converter transformer insulation is a major
challenge. The insulation of these transformers is stressed by both
AC and DC voltages. Particle contamination is one of the major
problems in insulation structures, as they generate partial discharges
leading it to major failure of insulation. Similarly corona discharges
occur in transformer insulation. This partial discharge due to particle
movement / corona formation in insulation structure under different
voltage wave shapes, are different. In the present study, UHF
technique is adopted to understand the discharge activity and could
be realized that the characteristics of UHF signal generated under
low and high fields are different. In the case of corona generated
signal, the frequency content of the UHF sensor output lies in the
range 0.3-1.2 GHz and is not much varied except for its increase in
magnitude of discharge with the increase in applied voltage. It is
realized that the current signal injected due to partial
discharges/corona is about 4ns duration measured for first one half
cycle. Wavelet technique is adopted in the present study. It allows
one to identify the frequency content present in the signal at different
instant of time. The STD-MRA analysis helps one to identify the
frequency band in which the energy content of the UHF signal is
maximum.
Abstract: This paper presents design and implements the
T-DOF PI controller design for a speed control of induction motor.
The voltage source inverter type space vector pulse width modulation
technique is used the drive system. This scheme leads to be able to
adjust the speed of the motor by control the frequency and amplitude
of the input voltage. The ratio of input stator voltage to frequency
should be kept constant. The T-DOF PI controller design by root
locus technique is also introduced to the system for regulates and
tracking speed response. The experimental results in testing the 120
watt induction motor from no-load condition to rated condition show
the effectiveness of the proposed control scheme.
Abstract: The breakdown strength characteristic of Low Density
Polyethylene films (LDPE) under DC voltage application and the
effect of water absorption have been studied. Mainly, our experiment
was investigated under two conditions; dry and heavy water
absorption. Under DC ramp voltage, the result found that the
breakdown strength under heavy water absorption has a lower value
than dry condition. In order to clarify the effect, the temperature rise of
film was observed using non contact thermograph until the occurrence
of the electrical breakdown and the conduction current of the sample
was also measured in correlation with the thermograph measurement.
From the observations, it was shown that under the heavy water
absorption, the hot spot in the samples appeared at lower voltage. At
the same voltage the temperature of the hot spot and conduction
current was higher than that under the dry condition. The measurement
result has a good correlation between the existence of a critical field
for conduction current and thermograph observation. In case of the
heavy water absorption, the occurrence of the threshold field was
earlier than the dry condition as result lead to higher of conduction
current and the temperature rise appears after threshold field was
significantly increased in increasing of field. The higher temperature
rise was caused by the higher current conduction as the result the
insulation leads to breakdown to the lower field application.
Abstract: In this paper, we apply the PQ theory with shunt active power filter in an unbalanced and distorted power system voltage to compensate the perturbations generated by non linear load. The power factor is also improved in the current source. The PLL system is used to extract the fundamental component of the even sequence under conditions mentioned of the power system voltage.
Abstract: This paper presents the DC voltage control design of D-STATCOM when the D-STATCOM is used for load voltage regulation. Although, the DC voltage can be controlled by active current of the D-STATCOM, reactive current still affects the DC voltage. To eliminate this effect, the control strategy with elimination effect of the reactive current is proposed and the results of the control with and without the elimination the effect of the reactive current are compared. For obtaining the proportional and integral gains of the PI controllers, the symmetrical optimum and genetic algorithms methods are applied. The stability margin of these methods are obtained and discussed in detail. In addition, the performance of the DC voltage control based on symmetrical optimum and genetic algorithms methods are compared. Effectiveness of the controllers designed was verified through computer simulation performed by using Power System Tool Block (PSB) in SIMULINK/MATLAB. The simulation results demonstrated that the DC voltage control proposed is effective in regulating DC voltage when the DSTATCOM is used for load voltage regulation.
Abstract: This study investigates a voltage-controllable liquid crystals lens with a Fresnel zone electrode. When applying a proper voltage on the liquid crystal cell, a Fresnel-zone-distributed electric field is induced to direct liquid crystals aligned in a concentric structure. Owing to the concentrically aligned liquid crystals, a Fresnel lens is formed. We probe the Fresnel liquid crystal lens using a polarized incident beam with a wavelength of 632.8 nm, finding that the diffraction efficiency depends on the applying voltage. A remarkable diffraction efficiency of ~39.5 % is measured at the voltage of 0.9V. Additionally, a dual focus lens is fabricated by attaching a plane-convex lens to the Fresnel liquid crystals cell. The Fresnel LC lens and the dual focus lens may be applied for DVD/CD pick-up head, confocal microscopy system, or electrically-controlling optical systems.
Abstract: The application of a simple microcontroller to deal
with a three variable input and a single output fuzzy logic controller,
with Proportional – Integral – Derivative (PID) response control
built-in has been tested for an automatic voltage regulator. The
fuzzifiers are based on fixed range of the variables of output voltage.
The control output is used to control the wiper motor of the auto
transformer to adjust the voltage, using fuzzy logic principles, so that
the voltage is stabilized. In this report, the author will demonstrate
how fuzzy logic might provide elegant and efficient solutions in the
design of multivariable control based on experimental results rather
than on mathematical models.
Abstract: In this paper, we present the design and experimental
evaluation of complementary energy path adiabatic logic (CEPAL)
based 1 bit full adder circuit. A simulative investigation on the
proposed full adder has been done using VIRTUOSO SPECTRE
simulator of cadence in 0.18μm UMC technology and its
performance has been compared with the conventional CMOS full
adder circuit. The CEPAL based full adder circuit exhibits the energy
saving of 70% to the conventional CMOS full adder circuit, at 100
MHz frequency and 1.8V operating voltage.
Abstract: Wastages such as grated coconut meat, spent tea and used sugarcane had contributed negative impacts to the environment. Vermicomposting method is fully utilized to manage the wastes towards a more sustainable approach. The worms that are used in the vermicomposting are Eisenia foetida and Eudrillus euginae. This research shows that the vermicompost of wastages has voltage of electrical energy and is able to light up the Light-Emitting Diode (LED) device. Based on the experiment, the use of replicated and double compartments of the component will produce double of voltage. Hence, for conclusion, this harmless and low cost technology of vermicompost can act as a dry cell in order to reduce the usage of hazardous chemicals that can contaminate the environment.
Abstract: The object of this paper is to design and analyze a
proportional – integral (PI) control for positive output elementary
super lift Luo converter (POESLLC), which is the start-of-the-art
DC-DC converter. The positive output elementary super lift Luo
converter performs the voltage conversion from positive source
voltage to positive load voltage. This paper proposes a
development of PI control capable of providing the good static and
dynamic performance compared to proportional – integralderivative
(PID) controller. Using state space average method
derives the dynamic equations describing the positive output
elementary super lift luo converter and PI control is designed. The
simulation model of the positive output elementary super lift Luo
converter with its control circuit is implemented in
Matlab/Simulink. The PI control for positive output elementary
super lift Luo converter is tested for transient region, line changes,
load changes, steady state region and also for components
variations.
Abstract: The influence of axial magnetic field (B=0.48 T) on
the variation of ionization efficiency coefficient h and secondary
electron emission coefficient g with respect to reduced electric field
E/P is studied at a new range of plane-parallel electrode spacing (0<
d< 20 cm) and different nitrogen working pressure between 0.5-20
Pa. The axial magnetic field is produced from an inductive copper
coil of radius 5.6 cm. The experimental data of breakdown voltage is
adopted to estimate the mean Paschen curves at different working
features. The secondary electron emission coefficient is calculated
from the mean Paschen curve and used to determine the minimum
breakdown voltage. A reduction of discharge voltage of about 25% is
investigated by the applied of axial magnetic field. At high interelectrode
spacing, the effect of axial magnetic field becomes more
significant for the obtained values of h but it was less for the values
of g.
Abstract: with increasing circuits- complexity and demand to
use portable devices, power consumption is one of the most
important parameters these days. Full adders are the basic block of
many circuits. Therefore reducing power consumption in full adders
is very important in low power circuits. One of the most powerconsuming
modules in full adders is XOR/XNOR circuit. This paper
presents two new full adders based on two new logic approaches. The
proposed logic approaches use one XOR or XNOR gate to implement
a full adder cell. Therefore, delay and power will be decreased. Using
two new approaches and two XOR and XNOR gates, two new full
adders have been implemented in this paper. Simulations are carried
out by HSPICE in 0.18μm bulk technology with 1.8V supply voltage.
The results show that the ten-transistors proposed full adder has 12%
less power consumption and is 5% faster in comparison to MB12T
full adder. 9T is more efficient in area and is 24% better than similar
10T full adder in term of power consumption. The main drawback of
the proposed circuits is output threshold loss problem.