Abstract: A mammal-s body can be seen as a blood vessel with
complex tunnels. When heart pumps blood periodically, blood runs
through blood vessels and rebounds from walls of blood vessels.
Blood pressure signals can be measured with complex but periodic
patterns. When an artery is clamped during a surgical operation, the
spectrum of blood pressure signals will be different from that of
normal situation. In this investigation, intestinal artery clamping
operations were conducted to a pig for simulating the situation of
intestinal blocking during a surgical operation. Similarity theory is a
convenient and easy tool to prove that patterns of blood pressure
signals of intestinal artery blocking and unblocking are surely
different. And, the algorithm of Hilbert Huang Transform can be
applied to extract the character parameters of blood pressure pattern.
In conclusion, the patterns of blood pressure signals of two different
situations, intestinal artery blocking and unblocking, can be
distinguished by these character parameters defined in this paper.
Abstract: The events of October 2010, where terrorists managed to get explosive devices onboard of three passenger aircrafts and two air freighters, demonstrated weaknesses of the international air cargo and airmail security. Ever since, postal security has gained interest among policymakers and authorities. This study augments the limited body of academic literature on the topic bydemarcating areas of postal security, identifying relevant stakeholders in each area, and investigating why these stakeholders engage in postal security. Research is based on a case study on Swiss Post’s mail service.
Abstract: Protective effect of ethanolic extract of polyherbal formulation (PHF) was studied on carbon tetrachloride induced liver damage on carbon tetrachloride induced liver damage. Treatment of rats with 250mg /kg body weight of ethanolic extract of PHF protected rats against carbon tetrachloride liver injury by significant lowerering 5’ nucleotidase (5’NT), Gamma Glutamyl transferase (GGT), Glutamate dehdyrogenasse (GDH) and Succinate Dehydrogenase (SDH) levels compared to control. Normalization in these enzyme levels indicates strong hepatoprotective property of PHF extract.
Abstract: The effects of commercial or bovine yeasts on the
performance and blood variables of broiler chickens intoxicated with
aflatoxin were investigated in broilers. Four hundred eighty broilers
(Arbor Acres; 3-wk-old) were randomly assigned to 4 groups. Each
group (120 broiler chickens) was further randomly divided into 6
replicates of 20 chickens. The treatments were control diet without
additives (treatment 1), 250 ppb AFB1 (treatment 2), commercial
yeast, Saccharomyces cerevisiae, (CY 2.5 x 107 CFU/g) + 250 ppb
AFB1 (treatment 3) and bovine yeast, Saccharomyces cerevisiae,
(BY 2.5 x 107 CFU/g + 250 ppb AFB1 (treatment 4). Complete
randomized design (CRD) was used in the experiment. Feed
consumption and body weight were recorded at every five-day
period. On day 42, carcass compositions were determined from 30
birds per treatment. While chicks were sacrificed, 3-4 ml blood
sample was taken and stored frozen at (-20°C) for serum chemical
analysis to determine effects of consumption of diets on blood
chemistry (total protein, albumin, glucose, urea, cholesterol and
triglycerides). There were no significant differences in ADFI among
the treatments(P>0.05). However, BWG, FCR and mortality were
highly significantly different (P
Abstract: Transpedicular screw fixation in spinal fractures,
degenerative changes, or deformities is a well-established procedure.
However, important rate of fixation failure due to screw bending,
loosening, or pullout are still reported particularly in weak bone stock
in osteoporosis. To overcome the problem, mechanism of failure has
to be fully investigated in vitro. Post-mortem human subjects are less
accessible and animal cadavers comprise limitations due to different
geometry and mechanical properties. Therefore, the development of a
synthetic model mimicking the realistic human vertebra is highly
demanded. A bone surrogate, composed of Polyurethane (PU) foam
analogous to cancellous bone porous structure, was tested for 3
different densities in this study. The mechanical properties were
investigated under uniaxial compression test by minimizing the end
artifacts on specimens. The results indicated that PU foam of 0.32
g.cm-3 density has comparable mechanical properties to human
cancellous bone in terms of young-s modulus and yield strength.
Therefore, the obtained information can be considered as primary
step for developing a realistic cancellous bone of human vertebral
body. Further evaluations are also recommended for other density
groups.
Abstract: To achieve accurate and precise results of finite
element analysis (FEA) of bones, it is important to represent the
load/boundary conditions as identical as possible to the human body
such as the bone properties, the type and force of the muscles, the
contact force of the joints, and the location of the muscle attachment.
In this study, the difference in the Von-Mises stress and the total
deformation was compared by classifying them into Case 1, which
shows the actual anatomical form of the muscle attached to the femur
when the same muscle force was applied, and Case 2, which gives a
simplified representation of the attached location. An inverse
dynamical musculoskeletal model was simulated using data from an
actual walking experiment to complement the accuracy of the
muscular force, the input value of FEA. The FEA method using the
results of the muscular force that were calculated through the
simulation showed that the maximum Von-Mises stress and the
maximum total deformation in Case 2 were underestimated by 8.42%
and 6.29%, respectively, compared to Case 1. The torsion energy and
bending moment at each location of the femur occurred via the stress
ingredient. Due to the geometrical/morphological feature of the femur
of having a long bone shape when the stress distribution is wide, as
shown in Case 1, a greater Von-Mises stress and total deformation are
expected from the sum of the stress ingredients. More accurate results
can be achieved only when the muscular strength and the attachment
location in the FEA of the bones and the attachment form are the same
as those in the actual anatomical condition under the various moving
conditions of the human body.
Abstract: The human friendly interaction is the key function of a human-centered system. Over the years, it has received much attention to develop the convenient interaction through intention recognition. Intention recognition processes multimodal inputs including speech, face images, and body gestures. In this paper, we suggest a novel approach of intention recognition using a graph representation called Intention Graph. A concept of valid intention is proposed, as a target of intention recognition. Our approach has two phases: goal recognition phase and intention recognition phase. In the goal recognition phase, we generate an action graph based on the observed actions, and then the candidate goals and their plans are recognized. In the intention recognition phase, the intention is recognized with relevant goals and user profile. We show that the algorithm has polynomial time complexity. The intention graph is applied to a simple briefcase domain to test our model.
Abstract: In this paper, we have proposed a novel FinFET with
extended body under the poly gate, which is called EB-FinFET, and
its characteristic is demonstrated by using three-dimensional (3-D)
numerical simulation. We have analyzed and compared it with
conventional FinFET. The extended body height dependence on the
drain induced barrier lowering (DIBL) and subthreshold swing (S.S)
have been also investigated. According to the 3-D numerical
simulation, the proposed structure has a firm structure, an acceptable
short channel effect (SCE), a reduced series resistance, an increased
on state drain current (I
on) and a large normalized I
DS. Furthermore,
the structure can also improve corner effect and reduce self-heating
effect due to the extended body. Our results show that the EBFinFET
is excellent for nanoscale device.
Abstract: The ability to recognize humans and their activities by computer vision is a very important task, with many potential application. Study of human motion analysis is related to several research areas of computer vision such as the motion capture, detection, tracking and segmentation of people. In this paper, we describe a segmentation method for extracting human body contour in modified HLS color space. To estimate a background, the modified HLS color space is proposed, and the background features are estimated by using the HLS color components. Here, the large amount of human dataset, which was collected from DV cameras, is pre-processed. The human body and its contour is successfully extracted from the image sequences.
Abstract: Medical image modalities such as computed
tomography (CT), magnetic resonance imaging (MRI), ultrasound
(US), X-ray are adapted to diagnose disease. These modalities
provide flexible means of reviewing anatomical cross-sections and
physiological state in different parts of the human body. The raw
medical images have a huge file size and need large storage
requirements. So it should be such a way to reduce the size of those
image files to be valid for telemedicine applications. Thus the image
compression is a key factor to reduce the bit rate for transmission or
storage while maintaining an acceptable reproduction quality, but it is
natural to rise the question of how much an image can be compressed
and still preserve sufficient information for a given clinical
application. Many techniques for achieving data compression have
been introduced. In this study, three different MRI modalities which
are Brain, Spine and Knee have been compressed and reconstructed
using wavelet transform. Subjective and objective evaluation has
been done to investigate the clinical information quality of the
compressed images. For the objective evaluation, the results show
that the PSNR which indicates the quality of the reconstructed image
is ranging from (21.95 dB to 30.80 dB, 27.25 dB to 35.75 dB, and
26.93 dB to 34.93 dB) for Brain, Spine, and Knee respectively. For
the subjective evaluation test, the results show that the compression
ratio of 40:1 was acceptable for brain image, whereas for spine and
knee images 50:1 was acceptable.
Abstract: Photoplethysmography is a simple measurement of the
variation in blood volume in tissue. It detects the pulse signal of heart
beat as well as the low frequency signal of vasoconstriction and
vasodilation. The transmission type measurement is limited to only a
few specific positions for example the index finger that have a short
path length for light. The reflectance type measurement can be
conveniently applied on most parts of the body surface. This study
analyzed the factors that determine the quality of reflectance
photoplethysmograph signal including the emitter-detector distance,
wavelength, light intensity, and optical properties of skin tissue.
Light emitting diodes (LEDs) with four different visible
wavelengths were used as the light emitters. A phototransistor was
used as the light detector. A micro translation stage adjusts the
emitter-detector distance from 2 mm to 15 mm.
The reflective photoplethysmograph signals were measured on
different sites. The optimal emitter-detector distance was chosen to
have a large dynamic range for low frequency drifting without signal
saturation and a high perfusion index. Among these four wavelengths,
a yellowish green (571nm) light with a proper emitter-detection
distance of 2mm is the most suitable for obtaining a steady and reliable
reflectance photoplethysmograph signal
Abstract: This paper numerically investigates the effects of input
speed on the overall dynamic characteristics of a multi-body system
with differently located revolute clearance joints without friction. A
typical planar slider-crank mechanism is used as a demonstration case
in which the effects of the input speed on the dynamic performance
of the mechanism with a revolute clearance joint between the crank
and connecting rod, and between the connecting rod and slider are
separately investigated with comprehensive observations numerically
presented. It is observed that, changing the driving speed of a multibody
system makes the behavior of the system to change from
either periodic to chaotic, or chaotic to periodic depending on which
joint has clearance. The location of the clearance revolute joint and
the operating speed of a multi-body system play a crucial role in
predicting accurately the dynamic responses of the system. Therefore
the dynamic behavior of one clearance revolute joint cannot be used
as a general case for a mechanical system.
Abstract: The current of professional bicycle pedal-s
manufacturing model mostly used casting, forging, die-casting
processing methods, so the paper used 7075 aluminum alloy which is
to produce the bicycle parts most commonly, and employs the
rigid-plastic finite element (FE) DEFORMTM 3D software to simulate
and to analyze the professional bicycle pedal design. First we use Solid
works 2010 3D graphics software to design the professional bicycle
pedal of the mold and appearance, then import finite element (FE)
DEFORMTM 3D software for analysis. The paper used rigid-plastic
model analytical methods, and assuming mode to be rigid body. A
series of simulation analyses in which the variables depend on
different temperature of forging billet, friction factors, forging speed,
mold temperature are reveal to effective stress, effective strain, damage
and die radial load distribution for forging bicycle pedal. The analysis
results hope to provide professional bicycle pedal forming mold
references to identified whether suit with the finite element results for
high-strength design suitability of aluminum alloy.
Abstract: Developing a nation geared by the principle of
sustainable development has been one of the piers in moulding a
greater nation for Malaysia since its independence. This is seen by
the act of joining the United Nations in 1957, just a month after
gaining their independence. The United Nations is an international
organization that aims to unite the nations worldwide based on
justice, human dignity and human well-being. Malaysia has
established a local body called the United Nations Malaysia which
collaborates with the government to accomplish the aim of
supporting sustainable development in Malaysia. Agenda 21 is an
international document produced from the Earth Summit providing
guidelines of implementing sustainable development globally,
nationally and locally. Initiatives of applying Agenda 21 in Malaysia
have been taken by the government and non-profit organizations to
expose issues regarding sustainable development and providing
environmental education to the community to increase awareness
towards environmental protection.
Abstract: The objective of this study is to determine the thermal comfort among worker at Malaysian automotive industry. One critical manual assembly workstation had been chosen as a subject for the study. The human subjects for the study constitute operators at Body Assembly Station of the factory. The environment examined was the Relative Humidity (%), Airflow (m/s), Air Temperature (°C) and Radiant Temperature (°C) of the surrounding workstation area. The environmental factors were measured using Babuc apparatus, which is capable to measure simultaneously those mentioned environmental factors. The time series data of fluctuating level of factors were plotted to identify the significant changes of factors. Then thermal comfort of the workers were assessed by using ISO Standard 7730 Thermal sensation scale by using Predicted Mean Vote (PMV). Further Predicted percentage dissatisfied (PPD) is used to estimate the thermal comfort satisfaction of the occupant. Finally the PPD versus PMV were plotted to present the thermal comfort scenario of workers involved in related workstation. The result of PMV at the related industry is between 1.8 and 2.3, where PPD at that building is between 60% to 84%. The survey result indicated that the temperature more influenced comfort to the occupants
Abstract: Many studies have emphasized the importance of
resistive exercise to maintain a healthy human body, particular in
prevention of weakening of physical strength. Recently, some studies
advocated that an application of vibration as a supplementary means in
a regular training was effective in encouraging physical strength. Aim
of the current study was, therefore, to identify if an application of
vibration in a resistive exercise was effective in encouraging physical
strength as that in a regular training. A 3-dimensional virtual lower
extremity model for a healthy male and virtual leg-press model were
generated and synchronized. Dynamic leg-press exercises on a slide
machine with/without extra load and on a footboard with vibration as
well as on a slide machine with extra load were analyzed. The results
of the current indicated that the application of the vibration on the
dynamic leg-press exercise might be not greatly effective in
encouraging physical strength, compared with the dynamic leg press
exercise with extra load. It was, however, thought that the application
of the vibration might be helpful to elderly individuals because the
reduced maximum muscle strength appeared by the effect of the
vibration may avoid a muscular spasm, which can be driven from a
high muscle strength sometimes produced during the leg-press
exercise with extra load.
Abstract: This study was conducted to investigate the optimum
levels of glutamine (Gln) supplementation in broiler diets. A total of
32 one-day-old male chicks with initial body weight 41.5 g were
segregated into 4 groups (8 chicks per group) and subsequently
distributed to individual cages. Feed and water were provided ad
libitum for 21 days. Four dietary treatments were as follows: control
and supplemented Gln at 1, 2 and 3%, respectively. The results found
that the addition Gln had no negative effects on dry matter, organic
matter, ash digestibility or nitrogen retention. Birds fed with 1% Gln
had significantly higher villi wide and villi height : crypt depth ratio
in duodenum than the control chicks and 2 and 3% Gln chicks. It is
suggested that the addition of Gln at 1% indicated a beneficial effect
on improving small intestinal morphology, in addition Gln may
stimulate immune organ development of broiler chickens.
Abstract: Magnesium alloy has been widely investigated as
biodegradable cardiovascular stent and bone implant. Its application
for biodegradable esophageal stenting remains unexplored. This
paper reports the biodegradation behaviors of AZ31 magnesium alloy
in artificial saliva and various types of beverage in vitro. Results
show that the magnesium ion release rate of AZ31 in artificial saliva
for a stent (2cm diameter, 10cm length at 50% stent surface
coverage) is 43 times lower than the daily allowance of human body
magnesium intakes. The degradation rates of AZ31 in different
beverages could also be significantly different. These results suggest
that the esophagus in nature is a less aggressive chemical
environment for degradation of magnesium alloys. The significant
difference in degradation rates of AZ31 in different beverages opens
new opportunities for development of degradation controllable
esophageal stent through customizing ingested beverages.
Abstract: There are various kinds of medical equipment which
requires relatively accurate positional adjustments for successful
treatment. However, patients tend to move without notice during a
certain span of operations. Therefore, it is common practice that
accompanying operators adjust the focus of the equipment. In this
paper, tracking controllers for medical equipment are suggested to
replace the operators. The tracking controllers use AHRS sensor
information to recognize the movements of patients. Sensor fusion is
applied to reducing the error magnitudes through linear Kalman filters.
The image processing of optical markers is included to adjust the
accumulation errors of gyroscope sensor data especially for yaw
angles.
The tracking controller reduces the positional errors between the
current focus of a device and the target position on the body of a
patient. Since the sensing frequencies of AHRS sensors are very high
compared to the physical movements, the control performance is
satisfactory. The typical applications are, for example, ESWT or
rTMS, which have the error ranges of a few centimeters.