Abstract: Present study focused on the utilization of solar
energy by the help of photovoltaic greenhouse solar dryer under
forced mode. A single slope photovoltaic greenhouse solar dryer has
been proposed and thermal modelling has been developed. Various
parameters have been calculated by thermal modelling such as
greenhouse room temperature, cell temperature, crop temperature and
air temperature at exit of greenhouse. Further cell efficiency, thermal
efficiency, and overall thermal efficiency have been calculated for a
typical day of May and November. It was found that system can
generate equivalent thermal energy up to 7.65 kW and 6.66 kW per
day for clear day of May and November respectively.
Abstract: The Flexible AC Transmission System (FACTS)
technology is a new advanced solution that increases the reliability
and provides more flexibility, controllability, and stability of a power
system. The Unified Power Flow Controller (UPFC), as the most
versatile FACTS device for regulating power flow, is able to control
respectively transmission line real power, reactive power, and node
voltage. The main purpose of this paper is to analyze the effect of the
UPFC on the load flow, the power losses, and the voltage stability
using NEPLAN software modules, Newton-Raphson load flow is
used for the power flow analysis and the modal analysis is used for
the study of the voltage stability. The simulation was carried out on
the IEEE 14-bus test system.
Abstract: The power buck converter is the most widely used
DC/DC converter topology. They have a very large application area
such as DC motor drives, photovoltaic power system which require
fast transient responses and high efficiency over a wide range of load
current. This work proposes, the modelling of DC/DC power buck
converter using state-space averaging method and the current-mode
control using a proportional-integral controller. The efficiency of the
proposed model and control loop are evaluated with operating point
changes. The simulation results proved the effectiveness of the linear
model of DC/DC power buck converter.
Abstract: The layered structure LiNi1/3Co1/3Mn1/3-xAlxO2 (x = 0 ~
0.04) series cathode materials were synthesized by a carbonate
co-precipitation method, followed by a high temperature calcination
process. The influence of Al substitution on the microstructure and
electrochemical performances of the prepared materials was
investigated by X-Ray diffraction (XRD), scanning electron
microscopy (SEM), and galvanostatic charge/discharge test. The
results show that the LiNi1/3Co1/3Mn1/3-xAlxO2 has a well-ordered
hexagonal α-NaFeO2 structure. Although the discharge capacity of
Al-doped samples decreases as x increases,
LiNi1/3Co1/3Mn1/3-0.02Al0.02O2 exhibits superior capacity retention at
high voltage (4.6 V). Therefore, LiNi1/3Co1/3Mn1/3-0.02Al0.02O2 is a
promising material for “green” vehicles.
Abstract: Centrifugal-casting machine is used in manufacturing
special machine components like multi-layer journal bearing used in
all internal combustion engine, steam, gas turbine and air craft turboengine
where isotropic properties and high precisions are desired.
Moreover, this machine can be used in manufacturing thin wall hightech
machine components like cylinder liners and piston rings of IC
engine and other machine parts like sleeves, and bushes. Heavy-duty
machine component like railway wheel can also be prepared by
centrifugal casting. A lot of technological developments are required
in casting process for production of good casted machine body and
machine parts. Usually defects like blowholes, surface roughness,
chilled surface etc. are found in sand casted machine parts. But these
can be removed by centrifugal casting machine using rotating
metallic die. Moreover, die rotation, its temperature control, and good
pouring practice can contribute to the quality of casting because of
the fact that the soundness of a casting in large part depends upon
how the metal enters into the mold or dies and solidifies. Poor
pouring practice leads to variety of casting defects such as
temperature loss, low quality casting, excessive turbulence, over
pouring etc. Besides these, handling of molten metal is very
unsecured and dangerous for the workers. In order to get rid of all
these problems, the need of an automatic pouring device arises. In
this research work, a robot assisted pouring device and a centrifugal
casting machine are designed, developed constructed and tested
experimentally which are found to work satisfactorily. The robot
assisted pouring device is further modified and developed for using it
in actual metal casting process. Lot of settings and tests are required
to control the system and ultimately it can be used in automation of
centrifugal casting machine to produce high-tech machine parts with
desired precision.
Abstract: Voltage level must be raised in order to deliver the
produced energy to the consumption zones with less loss and less
cost. Power transformers used to raise or lower voltage are important
parts of the energy transmission system. Power transformers used in
switchgear and power generation plants stay in human's intensive
habitat zones as a result of expanding cities. Accordingly, noise
levels produced by power transformers have begun more and more
important and they have established itself as one of the research field.
In this research, the noise cause on transformers has been
investigated, it's causes has been examined and noise measurement
techniques have been introduced. Examples of transformer noise test
results are submitted and precautions to be taken were discussed for
the purpose of decreasing of the noise which will occurred by
transformers.
Abstract: This paper describes two methods for the reduction of
the peak input current during the boosting of Dickson charge pumps.
Both methods are implemented in the fully integrated Dickson charge
pumps of a high-voltage display driver chip for smart-card
applications. Experimental results reveal good correspondence with
Spice simulations and show a reduction of the peak input current by a
factor of 6 during boosting.
Abstract: Dan C. Lortie’s Schoolteacher: A sociological study is
one of the best works on the sociology of teaching since W. Waller’s
classic study. It is a book worthy of review. Following the tradition of
symbolic interactionists, Lortie demonstrated the qualities who studied
the occupation of teaching. Using several methods to gather effective
data, Lortie has portrayed the ethos of the teaching profession.
Therefore, the work is an important book on the teaching profession
and teacher culture. Though outstanding, Lortie’s work is also flawed
in that his perspectives and methodology were adopted largely from
symbolic interactionism. First, Lortie in his work analyzed many
points regarding teacher culture; for example, he was interested in
exploring “sentiment,” “cathexis,” and “ethos.” Thus, he was more a
psychologist than a sociologist. Second, symbolic interactionism led
him to discern the teacher culture from a micro view, thereby missing
the structural aspects. For example, he did not fully discuss the issue of
gender and he ignored the issue of race. Finally, following the
qualitative sociological tradition, Lortie employed many qualitative
methods to gather data but only foucused on obtaining and presenting
interview data. Moreover, he used measurement methods that were too
simplistic for analyzing quantitative data fully.
Abstract: While the feature sizes of recent Complementary Metal
Oxid Semiconductor (CMOS) devices decrease the influence of static
power prevails their energy consumption. Thus, power savings that
benefit from Dynamic Frequency and Voltage Scaling (DVFS) are
diminishing and temporal shutdown of cores or other microchip
components become more worthwhile. A consequence of powering off unused parts of a chip is that the
relative difference between idle and fully loaded power consumption
is increased. That means, future chips and whole server systems gain
more power saving potential through power-aware load balancing,
whereas in former times this power saving approach had only
limited effect, and thus, was not widely adopted. While powering
off complete servers was used to save energy, it will be superfluous
in many cases when cores can be powered down. An important
advantage that comes with that is a largely reduced time to respond
to increased computational demand. We include the above developments in a server power model
and quantify the advantage. Our conclusion is that strategies from
datacenters when to power off server systems might be used in the
future on core level, while load balancing mechanisms previously
used at core level might be used in the future at server level.
Abstract: With 40% of total world energy consumption,
building systems are developing into technically complex large
energy consumers suitable for application of sophisticated power
management approaches to largely increase the energy efficiency
and even make them active energy market participants. Centralized
control system of building heating and cooling managed by
economically-optimal model predictive control shows promising
results with estimated 30% of energy efficiency increase. The research
is focused on implementation of such a method on a case study
performed on two floors of our faculty building with corresponding
sensors wireless data acquisition, remote heating/cooling units and
central climate controller. Building walls are mathematically modeled
with corresponding material types, surface shapes and sizes. Models
are then exploited to predict thermal characteristics and changes in
different building zones. Exterior influences such as environmental
conditions and weather forecast, people behavior and comfort
demands are all taken into account for deriving price-optimal climate
control. Finally, a DC microgrid with photovoltaics, wind turbine,
supercapacitor, batteries and fuel cell stacks is added to make the
building a unit capable of active participation in a price-varying
energy market. Computational burden of applying model predictive
control on such a complex system is relaxed through a hierarchical
decomposition of the microgrid and climate control, where the
former is designed as higher hierarchical level with pre-calculated
price-optimal power flows control, and latter is designed as lower
level control responsible to ensure thermal comfort and exploit
the optimal supply conditions enabled by microgrid energy flows
management. Such an approach is expected to enable the inclusion
of more complex building subsystems into consideration in order to
further increase the energy efficiency.
Abstract: This paper presents the experimental results of 11 kV
and 33 kV silicon composite insulators under artificial salt and urea
polluted conditions. The tests were carried out under different
seasons like summer, winter, and monsoon. The artificial pollution is
prepared by properly dissolving the salt and urea in the water. The
prepared salt and urea pollutions are sprayed on the insulators and
dried up for sufficiently large time. The process is continued until a
uniform layer is formed on the surface of insulator. For each insulator
rating, four samples were tested. The maximum leakage current and
breakdown voltage were measured. From experimental data,
performance of test specimen is evaluated by comparing breakdown
voltage and leakage current during different seasons when exposed to
salt and urea polluted conditions. From these results the performance
of the insulators can be predicted when they are installed in
industrial, agricultural, and coastal areas. The experimental tests were
carried out in the High Voltage laboratory using two stage cascade
transformer having the rating of 1000 kVA, 500 kV.
Abstract: This paper aims to analysis the behavior of DC corona
discharge in wire-to-plate electrostatic precipitators (ESP). Currentvoltage
curves are particularly analyzed. Experimental results show
that discharge current is strongly affected by the applied voltage. The proposed method of current identification is to use the method
of least squares. Least squares problems that of into two categories:
linear or ordinary least squares and non-linear least squares,
depending on whether or not the residuals are linear in all unknowns.
The linear least-squares problem occurs in statistical regression
analysis; it has a closed-form solution. A closed-form solution (or
closed form expression) is any formula that can be evaluated in a
finite number of standard operations. The non-linear problem has no
closed-form solution and is usually solved by iterative.
Abstract: This paper focuses on the study of DC-to-DC
converters, which are suitable for low-voltage high-power
applications. The output voltages generated by renewable energy
sources such as photovoltaic arrays and fuel cell stacks are
generally low and required to be increased to high voltage levels.
Development of DC-to-DC converters, which provide high step-up
voltage conversion ratios with high efficiencies and low voltage
stresses, is one of the main issues in the development of renewable
energy systems. A procedure for three converters−conventional
DC-to-DC converter, interleaved boost converter, and isolated flyback
based converter, is illustrated for a given set of specifications. The
selection among the converters for the given application is based on
the voltage conversion ratio, efficiency, and voltage stresses.
Abstract: This first-attempt study revealed that decolorized
intermediates of azo dyes could act as redox mediators to assist
wastewater (WW) decolorization due to enhancement of
electron-transport phenomena. Electrochemical impedance spectra
indicated that hydroxyl and amino-substituent(s) were functional
group(s) as redox-mediator(s). As azo dyes are usually multiple
benzene-rings structured, their derived decolorized intermediates are
likely to play roles of electron shuttles due to lower barrier of energy
gap for electron shuttling. According to cyclic voltammetric profiles,
redox mediating characteristics of decolorized intermediates of azo
dyes (e.g., RBu171, RR198, RR141, RBk5) were clearly disclosed.
With supplementation of biodecolorized metabolites of RR141 and
198, decolorization performance of could be evidently augmented.
This study also suggested the optimal modes of microbial fuel cell
(MFC)-assisted WW decolorization would be plug-flow or batch
mode of operation with no mix. Single chamber-MFCs would be more
favourable than double chamber MFCs due to non-mixing contacting
reactor scheme for operation.
Abstract: Fluctuations of Schottky diode parameters in a
structure of the mixer are investigated. These fluctuations are
manifested in two ways. At the first, they lead to fluctuations in the
transfer factor that is lead to the amplitude fluctuations in the signal
of intermediate frequency. On the basis of the measurement data of
1/f noise of the diode at forward current, the estimation of a spectrum
of relative fluctuations in transfer factor of the mixer is executed.
Current dependence of the spectrum of relative fluctuations in
transfer factor of the mixer and dependence of the spectrum of
relative fluctuations in transfer factor of the mixer on the amplitude
of the heterodyne signal are investigated. At the second, fluctuations
in parameters of the diode lead to occurrence of 1/f noise in the
output signal of the mixer. This noise limits the sensitivity of the
mixer to the value of received signal.
Abstract: Green and renewable energy is getting extraordinary
consideration today, because of ecological concerns made by blazing
of fossil powers. Photovoltaic and wind power generation are the
basic decisions for delivering power in this respects. Producing
power by the sun based photovoltaic systems is known to the world,
yet control makers may get confounded to pick between on-grid and
off-grid systems. In this exploration work, an endeavor is made to
compare the off-grid (stand-alone) and on-grid (grid-connected)
frameworks. The work presents relative examination, between two
distinctive PV frameworks situated at V.V.P. Engineering College,
Rajkot. The first framework is 100 kW remain solitary and the
second is 60 kW network joined. The real-time parameters compared
are; output voltage, load current, power in-flow, power output,
performance ratio, yield factor, and capacity factor. The voltage
changes and the power variances in both frameworks are given
exceptional consideration and the examination is made between the
two frameworks to judge the focal points and confinements of both
the frameworks.
Abstract: Brushless DC motors (BLDC) are widely used in
industrial areas. The BLDC motors are driven either by indirect ACAC
converters or by direct AC-AC converters. Direct AC-AC
converters i.e. matrix converters are used in this paper to drive the
three phase BLDC motor and it eliminates the bulky DC link energy
storage element. A matrix converter converts the AC power supply to
an AC voltage of variable amplitude and variable frequency. A
control technique is designed to generate the switching pulses for the
three phase matrix converter. For the control of speed of the BLDC
motor a separate PI controller and Fuzzy Logic Controller (FLC) are
designed and a hysteresis current controller is also designed for the
control of motor torque. The control schemes are designed and tested
separately. The simulation results of both the schemes are compared
and contrasted in this paper. The results show that the fuzzy logic
control scheme outperforms the PI control scheme in terms of
dynamic performance of the BLDC motor. Simulation results are
validated with the experimental results.
Abstract: The increase in electric power demand in face of
environmental issues has intensified the participation of renewable
energy sources such as photovoltaics, in the energy matrix of various
countries. Due to their operational characteristics, they can generate
time-varying harmonic and inter-harmonic distortions. For this
reason, the application of methods of measurement based on
traditional Fourier analysis, as proposed by IEC 61000-4-7, can
provide inaccurate results. Considering the aspects mentioned herein,
came the idea of the development of this work which aims to present
the results of a comparative evaluation between a methodology
arising from the combination of the Prony method with the Kalman
filter and another method based on the IEC 61000-4-30 and IEC
61000-4-7 standards. Employed in this study were synthetic signals
and data acquired through measurements in a 50kWp photovoltaic
installation.
Abstract: Hydrogen produced by means of polymer electrolyte
membrane electrolyzer (PEME) is one of the most promising
methods due to clean and renewable energy source. In the process,
some energy loss due to mass transfer through a PEM is caused by
diffusion, electro-osmotic drag, and the pressure difference between
the cathode channel and anode channel. In PEME, water molecules
and ionic particles transferred between the electrodes from anode to
cathode, Extensive mixing of the hydrogen and oxygen at anode
channel due to gases cross-over must be avoided. In recent times the
consciousness of safety issue in high pressure PEME where the
oxygen mix with hydrogen at anode channel could create, explosive
conditions have generated a lot of concern. In this paper, the steady
state and simulation analysis of gases crossover in PEME on the
temperature and pressure effect are presented. The simulations have
been analysis in MATLAB based on the well-known Fick’s Law of
molecular diffusion. The simulation results indicated that as
temperature increases, there is a significant decrease in operating
voltage.
Abstract: Microcantilevers are the basic MEMS devices, which
can be used as sensors, actuators and electronics can be easily built
into them. The detection principle of microcantilever sensors is based
on the measurement of change in cantilever deflection or change in its
resonance frequency. The objective of this work is to explore the
analogies between mechanical and electrical equivalent of
microcantilever beams. Normally scientists and engineers working in
MEMS use expensive software like CoventorWare, IntelliSuite,
ANSYS/Multiphysics etc. This paper indicates the need of developing
electrical equivalent of the MEMS structure and with that, one can
have a better insight on important parameters, and their interrelation of
the MEMS structure. In this work, considering the mechanical model
of microcantilever, equivalent electrical circuit is drawn and using
force-voltage analogy, it is analyzed with circuit simulation software.
By doing so, one can gain access to powerful set of intellectual tools
that have been developed for understanding electrical circuits Later
the analysis is performed using ANSYS/Multiphysics - software based
on finite element method (FEM). It is observed that both mechanical
and electrical domain results for a rectangular microcantlevers are in
agreement with each other.