Abstract: This paper treats a design of combined control of a
single phase power factor correction (PFC). The strategy of the
proposed control is based on two parts, the first, for the outer loop
(DC output regulated voltage), and the second govern the input
current of the converter in order to achieve a sinusoidal form in phase
with the grid voltage. Two kinds of regulators are used, Fuzzy
controller for the outer loop and predictive controller for the inner
loop. The controllers are verified and discussed through simulation
under MATLAB/Simulink platform. Also an experimental
confirmation is applied. Results present a high dynamic performance
under various parameters changes.
Abstract: This paper aims to investigate and emphasize the importance of the grid-connected photovoltaic (PV) systems regarding the intermittent nature of renewable generation, and the characterization of PV generation with regard to grid code compliance. The development of Photovoltaic systems and expansion plans relating to the futuristic in worldwide is elaborated. The most important impacts of grid connected photovoltaic systems on distribution networks as well as the Penetration level of PV system was investigated.
Abstract: Due to the higher power loss levels in electronic components, the thermal design of PCBs (Printed Circuit Boards) of an assembled device becomes one of the most important quality factors in electronics. Nonetheless, some of leading causes of the microelectronic component failures are due to higher temperatures, the leakages or thermal-mechanical stress, which is a concern, is the reliability of microelectronic packages. This article presents an experimental approach to measure the junction temperature of exposed pad packages. The implemented solution is in a prototype phase, using a temperature-sensitive parameter (TSP) to measure temperature directly on the die, validating the numeric results provided by the Mechanical APDL (Ansys Parametric Design Language) under same conditions. The physical device-under-test is composed by a Thermal Test Chip (TTC-1002) and assembly in a QFN cavity, soldered to a test-board according to JEDEC Standards. Monitoring the voltage drop across a forward-biased diode, is an indirectly method but accurate to obtain the junction temperature of QFN component with an applied power range between 0,3W to 1.5W. The temperature distributions on the PCB test-board and QFN cavity surface were monitored by an infra-red thermal camera (Goby-384) controlled and images processed by the Xeneth software. The article provides a set-up to monitorize in real-time the junction temperature of ICs, namely devices with the exposed pad package (i.e. QFN). Presenting the PCB layout parameters that the designer should use to improve thermal performance, and evaluate the impact of voids in solder interface in the device junction temperature.
Abstract: This paper presents the modeling and the control of a grid-connected photovoltaic system (PVS). Firstly, the MPPT control of the PVS and its associated DC/DC converter has been analyzed in order to extract the maximum of available power. Secondly, the control system of the grid side converter (GSC) which is a three-phase voltage source inverter (VSI) has been presented. A special attention has been paid to the control algorithms of the GSC converter during grid voltages imbalances. Especially, three different control objectives are to achieve; the mitigation of the grid imbalance adverse effects, at the point of common coupling (PCC), on the injected currents, the elimination of double frequency oscillations in active power flow, and the elimination of double frequency oscillations in reactive power flow. Simulation results of two control strategies have been performed via MATLAB software in order to demonstrate the particularities of each control strategy according to power quality standards.
Abstract: Electrical impedance tomography is a non-invasive medical imaging technique suitable for medical applications. This paper describes an electrical impedance tomography device with the ability to navigate a robotic arm to manipulate a target object. The design of the device includes various hardware and software sections to perform medical imaging and control the robotic arm. In its hardware section an image is formed by 16 electrodes which are located around a container. This image is used to navigate a 3DOF robotic arm to reach the exact location of the target object. The data set to form the impedance imaging is obtained by having repeated current injections and voltage measurements between all electrode pairs. After performing the necessary calculations to obtain the impedance, information is transmitted to the computer. This data is fed and then executed in MATLAB which is interfaced with EIDORS (Electrical Impedance Tomography Reconstruction Software) to reconstruct the image based on the acquired data. In the next step, the coordinates of the center of the target object are calculated by image processing toolbox of MATLAB (IPT). Finally, these coordinates are used to calculate the angles of each joint of the robotic arm. The robotic arm moves to the desired tissue with the user command.
Abstract: This paper presents a digital non-linear pulse-width modulation (PWM) controller in a high-voltage (HV) buck-boost DC-DC converter for the piezoelectric transducer of the down-hole acoustic telemetry system. The proposed design controls the generation of output signal with voltage higher than the supply voltage and is targeted to work under high temperature. To minimize the power consumption and silicon area, a simple and efficient design scheme is employed to develop the PWM controller. The proposed PWM controller consists of serial to parallel (S2P) converter, data assign block, a mode and duty cycle controller (MDC), linearly PWM (LPWM) and noise shaper, pulse generator and clock generator. To improve the reliability of circuit operation at higher temperature, this design is fabricated with the 1.0-μm silicon-on-insulator (SOI) CMOS process. The implementation results validated that the proposed design has the advantages of smaller size, lower power consumption and robust thermal stability.
Abstract: The alternating current is the main power in all industries and other aspects especially for the short and mid distances, but as far as long a distance which exceeds 500 KMs, using the alternating current technically will face many difficulties and more costs because it's difficult to control the current and also other restrictions. Therefore, recently those reasons led to building transmission lines HVDC to transmit power for long distances. This document presents technical comparison and assessments for power transmission system among distances either ways and studying the stability of the system regarding the proportion of losses in the actual power sent and received between both sides in different systems and also categorizing filters used in the HVDC system and its impact and effect on reducing Harmonic in the power transmission. MATLAB /Simulink simulation software is used to simulate both HVAC & HVDC power transmission system topologies.
Abstract: Six peculiar architecture designs from the Frankfurt University will be discussed within this paper and their future potential of the adaptable and solar thin-film sheets implemented facades will be shown acting and reacting on climate/solar changes of their specific sites. The different aspects, as well as limitations with regard to technical and functional restrictions, will be named. The design process for a “multi-purpose building”, a “high-rise building refurbishment” and a “biker’s lodge” on the river Rheine valley, has been critically outlined and developed step by step from an international studentship towards an overall energy strategy, that firstly had to push the design to a plus-energy building and secondly had to incorporate bionic aspects into the building skins design. Both main parameters needed to be reviewed and refined during the whole design process. Various basic bionic approaches have been given [e.g. solar ivy TM, flectofin TM or hygroskin TM, which were to experiment with, regarding the use of bendable photovoltaic thin film elements being parts of a hybrid, kinetic façade system.
Abstract: The objective of this research is to forecast the monthly exchange rate between Thai baht and the US dollar and to compare two forecasting methods. The methods are Box-Jenkins’ method and Holt’s method. Results show that the Box-Jenkins’ method is the most suitable method for the monthly Exchange Rate between Thai Baht and the US Dollar. The suitable forecasting model is ARIMA (1,1,0) without constant and the forecasting equation is Yt = Yt-1 + 0.3691 (Yt-1 - Yt-2) When Yt is the time series data at time t, respectively.
Abstract: Since the heart of the hybrid system is the fuel cell and it has vital impact on efficiency and performance of cycle, in this study, the major modeling of electrochemical reaction within the fuel cell is analyzed. Also, solid oxide fuel cell is integrated with the gas turbine and thermodynamic analysis on different elements of hybrid system is applied. Next, in predefined operational points of hybrid cycle, the simulation results are obtained. Then, different source of irreversibility in fuel cell is modeled and influence of different major parameters on different irreversibility is computed and applied. Then, the effect of important parameters such as thickness and surface of electrolyte fuel cell are simulated in fuel cell and its dependency to these parameters is explained. At the end of the paper, different impact of parameters on fuel cell with a gas turbine and current density and voltage of fuel cell are simulated.
Abstract: The purpose of this paper is to study and compare two maximum power point tracking (MPPT) algorithms in a photovoltaic simulation system and also show a simulation study of maximum power point tracking (MPPT) for photovoltaic systems using perturb and observe algorithm and Incremental conductance algorithm. Maximum power point tracking (MPPT) plays an important role in photovoltaic systems because it maximize the power output from a PV system for a given set of conditions, and therefore maximize the array efficiency and minimize the overall system cost. Since the maximum power point (MPP) varies, based on the irradiation and cell temperature, appropriate algorithms must be utilized to track the (MPP) and maintain the operation of the system in it. MATLAB/Simulink is used to establish a model of photovoltaic system with (MPPT) function. This system is developed by combining the models established of solar PV module and DC-DC Boost converter. The system is simulated under different climate conditions. Simulation results show that the photovoltaic simulation system can track the maximum power point accurately.
Abstract: The article proposes maximum power point tracking without mechanical sensor using Multilayer Perceptron Neural Network (MLPNN). The aim of article is to reduce the cost and complexity but still retain efficiency. The experimental is that duty cycle is generated maximum power, if it has suitable qualification. The measured data from DC generator, voltage (V), current (I), power (P), turnover rate of power (dP), and turnover rate of voltage (dV) are used as input for MLPNN model. The output of this model is duty cycle for driving the converter. The experiment implemented using Arduino Uno board. This diagram is compared to MPPT using MLPNN and P&O control (Perturbation and Observation control). The experimental results show that the proposed MLPNN based approach is more efficiency than P&O algorithm for this application.
Abstract: In present study, an approach is adopted where photovoltaic thermal flat plate collector is integrated with compound parabolic concentrator. Analytical expression of temperature dependent electrical efficiency of N number of partially covered Photovoltaic Thermal (PVT) - Compound Parabolic Concentrator (CPC) water collector connected in series has been derived with the help of basic thermal energy balance equations. Analysis has been carried for winter weather condition at Delhi location, India. Energy and exergy performance of N - partially covered Photovoltaic Thermal (PVT) - Compound Parabolic Concentrator (CPC) Water collector system has been compared for two cases: (i) 25% area of water collector covered by PV module, (ii) 75% area of water collector covered by PV module. It is observed that case (i) has been best suited for thermal performance and case (ii) for electrical energy as well as overall exergy.
Abstract: The increasing demand of electric power is giving an
emphasis on the need for the maximum utilization of renewable
energy sources. On the other hand maintaining power quality to
satisfaction of utility is an essential requirement. In this paper the
design aspects of a Unified Power Quality Conditioner integrated
with photovoltaic system in a distributed generation is presented. The
proposed system consist of series inverter, shunt inverter are
connected back to back on the dc side and share a common dc-link
capacitor with Distributed Generation through a boost converter. The
primary task of UPQC is to minimize grid voltage and load current
disturbances along with reactive and harmonic power compensation.
In addition to primary tasks of UPQC, other functionalities such as
compensation of voltage interruption and active power transfer to the
load and grid in both islanding and interconnected mode have been
addressed. The simulation model is design in MATLAB/ Simulation
environment and the results are in good agreement with the published
work.
Abstract: In recent years, the use of renewable energy resources
instead of pollutant fossil fuels and other forms has increased.
Photovoltaic generation is becoming increasingly important as a
renewable resource since it does not cause in fuel costs, pollution,
maintenance, and emitting noise compared with other alternatives
used in power applications. In this paper, Perturb and Observe and
Incremental Conductance methods are used to improve energy
conversion efficiency under different environmental conditions. PI
controllers are used to control easily DC-link voltage, active and
reactive currents. The whole system is simulated under standard
climatic conditions (1000 W/m2, 250C) in MATLAB and the
irradiance is varied from 1000 W/m2 to 300 W/m2. The use of PI
controller makes it easy to directly control the power of the grid
connected PV system. Finally the validity of the system will be
verified through the simulations in MATLAB/Simulink environment.
Abstract: This work studies the effect of thickness on structural
and electrical properties of CuAlS2 thin films grown by two stage
vacuum thermal evaporation technique. CuAlS2 thin films of
thicknesses 50nm, 100nm and 200nm were deposited on suitably
cleaned corning 7059 glass substrate at room temperature (RT). In
the first stage Cu-Al precursors were grown at room temperature by
thermal evaporation and in the second stage Cu-Al precursors were
converted to CuAlS2 thin films by sulfurisation under sulfur
atmosphere at the temperature of 673K. The structural properties of
the films were examined by X-ray diffraction (XRD) technique while
electrical properties of the specimens were studied using four point
probe method. The XRD studies revealed that the films are of
crystalline in nature having tetragonal structure. The variations of the
micro-structural parameters, such as crystallite size (D), dislocation
density ( ), and micro-strain ( ), with film thickness were
investigated. The results showed that the crystallite sizes increase as
the thickness of the film increases. The dislocation density and
micro-strain decreases as the thickness increases. The resistivity ( )
of CuAlS2 film is found to decrease with increase in film thickness,
which is related to the increase of carrier concentration with film
thickness. Thus thicker films exhibit the lowest resistivity and high
carrier concentration, implying these are the most conductive films.
Low electrical resistivity and high carrier concentration are widely
used as the essential components in various optoelectronic devices
such as light-emitting diode and photovoltaic cells.
Abstract: In this paper, a single phase soft switched Zero Voltage Transition and Zero Current Transition (ZVT-ZCT) Power Factor Correction (PFC) boost converter is proposed. In the proposed PFC converter, the main switch turns on with ZVT and turns off with ZCT without any additional voltage or current stresses. Auxiliary switch turns on and off with zero current switching (ZCS). Also, the main diode turns on with zero voltage switching (ZVS) and turns off with ZCS. The proposed converter has features like low cost, simple control and structure. The output current and voltage are controlled by the proposed PFC converter in wide line and load range. The theoretical analysis of converter is clarified and the operating steps are given in detail. The simulation results of converter are obtained for 500 W and 100 kHz. It is observed that the semiconductor devices operate with soft switching (SS) perfectly. So, the switching power losses are minimum. Also, the proposed converter has 0.99 power factor with sinusoidal current shape.
Abstract: In this paper, an improved active snubber cell is proposed on account of soft switching (SS) family of pulse width modulation (PWM) DC-DC converters. The improved snubber cell provides zero-voltage transition (ZVT) turn on and zero-current transition (ZCT) turn off for main switch. The snubber cell decreases EMI noise and operates with SS in a wide range of line and load voltages. Besides, all of the semiconductor devices in the converter operate with SS. There is no additional voltage and current stress on the main devices. Additionally, extra voltage stress does not occur on the auxiliary switch and its current stress is acceptable value. The improved converter has a low cost and simple structure. The theoretical analysis of converter is clarified and the operating states are given in detail. The experimental results of converter are obtained by prototype of 500 W and 100 kHz. It is observed that the experimental results and theoretical analysis of converter are suitable with each other perfectly.
Abstract: This project aims at building an efficient and
automatic power monitoring SCADA system, which is capable of
monitoring the electrical parameters of high voltage powered devices
in real time for example RMS voltage and current, frequency, energy
consumed, power factor etc. The system uses RS-485 serial
communication interface to transfer data over longer distances.
Embedded C programming is the platform used to develop two
hardware modules namely: RTU and Master Station modules, which
both use the CC2540 BLE 4.0 microcontroller configured in slave /
master mode. The Si8900 galvanic ally isolated microchip is used to
perform ADC externally. The hardware communicates via UART
port and sends data to the user PC using the USB port. Labview
software is used to design a user interface to display current state of
the power loads being monitored as well as logs data to excel
spreadsheet file. An understanding of the Si8900’s auto baud rate
process is key to successful implementation of this project.
Abstract: This paper presents an analysis study on the impacts
of the changes of the capacitor banks, the loss of a transformer, and
the installation of distributed generation on the voltage total harmonic
distortion and harmonic resonance. The study is applied in a real
system in Oman, Sohar Industrial Port–C Substation Network.
Frequency scan method and Fourier series analysis method are used
with the help of EDSA software. Moreover, the results are compared
with limits specified by national Oman distribution code.