Abstract: Different terms of the Statistical Process Control (SPC)
has sketch in the fuzzy environment. However, Measurement System
Analysis (MSA), as a main branch of the SPC, is rarely investigated
in fuzzy area. This procedure assesses the suitability of the data to be
used in later stages or decisions of the SPC. Therefore, this research
focuses on some important measures of MSA and through a new
method introduces the measures in fuzzy environment. In this
method, which works based on Buckley approach, imprecision and
vagueness nature of the real world measurement are considered
simultaneously. To do so, fuzzy version of the gauge capability (Cg
and Cgk) are introduced. The method is also explained through
example clearly.
Abstract: Interstitial free steels possess better formability and
have many applications in automotive industries. Forming limit
diagrams (FLDs) indicate the formability of materials which can be
determined by experimental and finite element (FE) simulations.
FLDs were determined experimentally by LDH test, utilizing optical
strain measurement system for measuring the strains in different
width specimens and by FE simulations in Interstitial Free (IF) and
Interstitial Free High Strength (IFHS) steels. In this study, the
experimental and FE simulated FLDs are compared and also the
stress based FLDs were investigated.
Abstract: Implementation of advanced technologies requires
sophisticated instruments that deal with the operation, control,
restoration and protection of rapidly growing power system network
under normal and abnormal conditions. Presently, the applications of
Phasor Measurement Unit (PMU) are widely found in real time
operation, monitoring, controlling and analysis of power system
network as it eliminates the various limitations of supervisory control
and data acquisition system (SCADA) conventionally used in power
system. The use of PMU data is very rapidly increasing its
importance for online and offline analysis. Wide area measurement
system (WAMS) is developed as new technology by use of multiple
PMUs in power system. The present paper proposes a model of
Matlab based PMU using Discrete Fourier Transform (DFT)
algorithm and evaluation of its operation under different
contingencies. In this paper, PMU based two bus system having
WAMS network is presented as a case study.
Abstract: With a long history, dual-task has become one of the
most intriguing research fields regarding human brain functioning
and cognition. However, findings considering effects of taskinterrelations
are limited (especially, in combined motor and
cognitive tasks). Therefore, we aimed at developing a measurement
system in order to analyse interrelation effects of cognitive and motor
tasks. On the one hand, the present study demonstrates the
applicability of the measurement system and on the other hand first
results regarding a systematisation of different task combinations are
shown. Future investigations should combine imagine technologies
and this developed measurement system.
Abstract: HF Communication system is one of the attractive fields among many researchers since it can be reached long-distance areas with low-cost. This long-distance communication can be achieved by exploiting the ionosphere as a transmission medium for the HF radio wave. However, due to the dynamic nature of ionosphere, the channel characteristic of HF communication has to be investigated in order to gives better performances. Many techniques to characterize HF channel are available in the literature. However, none of those techniques describe the HF channel characteristic in low-latitude regions, especially equatorial areas. Since the ionosphere around equatorial region has an ESF phenomenon, it becomes an important investigation to characterize the wideband HF Channel in low-latitude region. On the other sides, the appearance of software-defined radio attracts the interest of many researchers. Accordingly, in this paper a SDR-based channel measurement system is proposed to be used for characterizing the HF channel in low-latitude region.
Abstract: This article describes an interesting and inexpensive laboratory experiment for undergraduate students of electronics, geography and related disciplines. The objective of the proposed experiment is to improve the students’ exposure on the basic principles of instrumentation and to demonstrate an electronic measurement system. A simple electronic curvy length measurement system is presented here. Such a system can be used to measure curvy lengths e.g. length of a river, road or railway line etc. from topographical map. The proposed system is composed of simple functional blocks which are usually demonstrated in laboratory or in theory course of electronics at the undergraduate level. The experiment is assigned to a group of students and it is found that the experiment can fulfill its objectives with high degree of satisfaction.
Abstract: This work aims to introduce an efficient and to standardize the measuring system analyses for automotive industrial. The study started by literature reviewing about the management and analyses measurement system. The approach of measuring system management, then, was constructed. Such approach was validated by collecting the current measuring system data using the equipments of interest including vernier caliper and micrometer. Their accuracy and precision of measurements were analyzed. Finally, the measuring system was improved and evaluated. The study showed that vernier did not meet its measuring characteristics based on the linearity whereas all equipments were lacking of the measuring precision characteristics. Consequently, the causes of measuring variation via the equipments of interest were declared. After the improvement, it was found that their measuring performance could be accepted as the standard required. Finally, the standardized approach for analyzing the measuring system of automotive was concluded.
Abstract: The knowledge about rock layers thickness,especially above drilled mining pavements is crucial for workers safety. The measuring systems used nowadays are generally imperfect and there is a strong demand for improvement. The application of a new type of a measurement system called Self-excited Acoustical System is presentedin the paper. The system was applied until now to monitor stress changes in metal and concrete constructions. The change in measurement methodology resulted in possibility of measuring the thickness of the rocks above the tunnels as well as thickness of a singular rocklayer. The idea is to find two resonance frequencies of the self-exited system,which consists of a vibration exciter and vibration receiver placed at a distance, which are coupled with a proper power amplifier, and which operate in a closed loop with a positive feedback. The resonance with the higher amplitude determines thickness of the whole rock, whereas the lower amplitude resonance indicates thickness of a singular layer. The results of the laboratory tests conducted on a group of different rock materials are also presented.
Abstract: In this study, a simple 2-D measurement system based on optical design was developed to measure the motion errors of the linear guideway. Compared with the transitional methods about the linear guideway for measuring the motion errors, our proposed 2-D optical measurement system can simultaneously measure horizontal and vertical running straightness errors for the linear guideway.
The performance of the 2-D optical measurement system is verified by experimental results. The standard deviation of the 2-D optical measurement system is about 0.4μm in the measurement range of 100 mm. The maximum measuring speed of the proposed automatic measurement instrument is 1 m/sec.
Abstract: The present paper describes the development of a low cost, highly accurate low capacitance measurement system that can be used over a range of 0 – 400 pF with a resolution of 1 pF. The range of capacitance may be easily altered by a simple resistance or capacitance variation of the measurement circuit. This capacitance measurement system uses quad two-input NAND Schmitt trigger circuit CD4093B with hysteresis for the measurement and this system is integrated with PIC 18F2550 microcontroller for data acquisition purpose. The microcontroller interacts with software developed in the PC end through USB architecture and an attractive graphical user interface (GUI) based system is developed in the PC end to provide the user with real time, online display of capacitance under measurement. The system uses a differential mode of capacitance measurement, with reference to a trimmer capacitance, that effectively compensates lead capacitances, a notorious error encountered in usual low capacitance measurements. The hysteresis provided in the Schmitt-trigger circuits enable reliable operation of the system by greatly minimizing the possibility of false triggering because of stray interferences, usually regarded as another source of significant error. The real life testing of the proposed system showed that our measurements could produce highly accurate capacitance measurements, when compared to cutting edge, high end digital capacitance meters.
Abstract: We propose an unconstrained measurement system for scratching motion based on mathematical model of unconstrained bed sensing method which could measure the bed vibrations due to the motion of the person on the bed. In this paper, we construct mathematical model of the unconstrained bed monitoring system; and we apply the unconstrained bed sensing method to the system for detecting scratching motion. The proposed sensors are placed under the three bed feet. When the person is lying on the bed, the output signals from the sensors are proportional to the magnitude of the vibration due to the scratching motion. Hence, we could detect the subject’s scratching motion from the output signals from ceramic sensors. We evaluated two scratching motions using the proposed system in the validity experiment as follows: 1st experiment is the subject’s scratching the right side cheek with his right hand, and; 2nd experiment is the subject’s scratching the shin with another foot. As the results of the experiment, we recognized the scratching signals that enable the determination when the scratching occurred. Furthermore, the difference among the amplitudes of the output signals enabled us to estimate where the subject scratched.
Abstract: Numbers of software quality measurement system have been implemented over the past few years, but none of them focuses on telecommunication industry. Software quality measurement system for telecommunication industry was a system that could calculate the quality value of the measured software that totally focused in telecommunication industry. Before designing a system, quality factors, quality attributes and quality metrics were identified based on literature review and survey. Then, using the identified quality factors, quality attributes and quality metrics, quality model for telecommunication industry was constructed. Each identified quality metrics had its own formula. Quality value for the system was measured based on the quality metrics and aggregated by referring to the quality model. It would classify the quality level of the software based on Net Satisfaction Index (NSI). The system was designed using object-oriented approach in web-based environment. Thus, existing of software quality measurement system was important to both developers and users in order to produce high quality software product for telecommunication industry.
Abstract: Modern management in most fields is performance based; both planning and implementation of maintenance and operational activities are driven by appropriately defined performance indicators. Continuous real-time data collection for management is becoming feasible due to technological advancements. Outdated and insufficient input data may result in incorrect decisions. When using deterministic models the uncertainty of the object state is not visible thus applying the deterministic models are more likely to give false diagnosis. Constructing structured probabilistic models of the performance indicators taking into consideration the surrounding indicator environment enables to estimate the trustworthiness of the indicator values. It also assists to fill gaps in data to improve the quality of the performance analysis and management decisions. In this paper authors discuss the application of probabilistic graphical models in the road performance measurement and propose a high-level conceptual model that enables analyzing and predicting more precisely future pavement deterioration based on road utilization.
Abstract: Microscopic emission and fuel consumption models
have been widely recognized as an effective method to quantify real
traffic emission and energy consumption when they are applied with
microscopic traffic simulation models. This paper presents a
framework for developing the Microscopic Emission (HC, CO, NOx,
and CO2) and Fuel consumption (MEF) models for light-duty
vehicles. The variable of composite acceleration is introduced into
the MEF model with the purpose of capturing the effects of historical
accelerations interacting with current speed on emission and fuel
consumption. The MEF model is calibrated by multivariate
least-squares method for two types of light-duty vehicle using
on-board data collected in Beijing, China by a Portable Emission
Measurement System (PEMS). The instantaneous validation results
shows the MEF model performs better with lower Mean Absolute
Percentage Error (MAPE) compared to other two models. Moreover,
the aggregate validation results tells the MEF model produces
reasonable estimations compared to actual measurements with
prediction errors within 12%, 10%, 19%, and 9% for HC, CO, NOx
emissions and fuel consumption, respectively.
Abstract: This study aims to discuss the effect of illumination and the color temperature of the lighting source under the office lighting environment on human psychological and physiological responses. In this study, 21 healthy participants were selected, and the Ryodoraku measurement system was utilized to measure their skin resistance change.The findings indicated that the effect of the color temperature of the lighting source on human physiological responses is significant within 90 min after turning the lights on; while after 90 min the effect of illumination on human physiological responses is higher than that of the color temperature. Moreover, the cardiovascular, digestive and endocrine systems are prone to be affected by the indoor lighting environment. During the long-term exposure to high intensity of illumination and high color temperature (2000Lux -6500K), the effect on the psychological responses turned moderate after the human visual system adopted to the lighting environment. However, the effect of the Ryodoraku value on human physiological responses was more significant with the increase of perceptive time. The effect of long time exposure to a lighting environment on the physiological responses is greater than its effect on the psychological responses. This conclusion is different from the traditional public viewpoint that the effect on the psychological responses is greater.
Abstract: This study is concerned with pH solution detection
using 2 × 4 flexible sensor array based on a plastic polyethylene
terephthalate (PET) substrate that is coated a conductive layer and a
ruthenium dioxide (RuO2) sensitive membrane with the technologies
of screen-printing and RF sputtering. For data analysis, we also
prepared a dynamic measurement system for acquiring the response
voltage and analyzing the characteristics of the working electrodes
(WEs), such as sensitivity and linearity. In this condition, an array
measurement system was designed to acquire the original signal from
sensor array, and it is based on the method of digital signal processing
(DSP). The DSP modifies the unstable acquisition data to a direct
current (DC) output using the technique of digital filter. Hence, this
sensor array can obtain a satisfactory yield, 62.5%, through the design
measurement and analysis system in our laboratory.
Abstract: In this paper a computer system for electromagnetic
properties measurements is designed. The system employs Agilent
4294A precision impedance analyzer to measure the amplitude and
the phase of a signal applied over a tested biological tissue sample.
Measured by the developed computer system data could be used for
tissue characterization in wide frequency range from 40Hz to
110MHz. The computer system can interface with output devices
acquiring flexible testing process.
Abstract: The aim of this study was to establish the feasibility of a minute incremental exercise testing protocol in young asthma children. Twenty-two children with clinically diagnosed mild to moderate asthma volunteered to participate. The maximum incremental exercise test was performed using a cycle ergometer with an electromagnetic braking. A warm-up unloaded for 2 minutes then the workload was started at 40 watts for 2 minutes, and then stepwise increments of 8 watts per 2 minutes were applied. The pedaling frequency was set at 50 rpm. Ventilation and gas exchange were measured with a breath-by-breath automatic metabolic measurement system. Results showed that this test was well tolerated by all asthmatic children. Most of the children reached the VO2 plateau and satisfied the criteria for maximal respiratory exchange ratio of ≥ 1. This Study demonstrated that this testing protocol was suitable for young asthmatic children.
Abstract: The growing outsourcing of logistics services
resulting from the ongoing current in firms of costs
reduction/increased efficiency means that it is becoming more and
more important for the companies doing the outsourcing to carry out
a proper evaluation.
The multiple definitions and measures of logistics service
performance found in research on the topic create a certain degree of
confusion and do not clear the way towards the proper measurement
of their performance. Do a model and a specific set of indicators exist
that can be considered appropriate for measuring the performance of
logistics services outsourcing in industrial environments? Are said
indicators in keeping with the objectives pursued by outsourcing? We
aim to answer these and other research questions in the study we have
initiated in the field within the framework of the international High
Performance Manufacturing (HPM) project of which this paper
forms part.
As the first stage of this research, this paper reviews articles
dealing with the topic published in the last 15 years with the aim of
detecting the models most used to make this measurement and
determining which performance indicators are proposed as part of
said models and which are most used. The first steps are also taken in
determining whether these indicators, financial and operational, cover
the aims that are being pursued when outsourcing logistics services.
The findings show there is a wide variety of both models and
indicators used. This would seem to testify to the need to continue
with our research in order to try to propose a model and a set of
indicators for measuring the performance of logistics services
outsourcing in industrial environments.
Abstract: Currently, many types of no-reversible compressed
sound source, represented by MP3 (MPEG Audio Layer-3) are
popular in the world and they are widely used to make the music file
size smaller. The sound data created in this way has less information as
compared to pre-compressed data. The objective of this study is by
analyzing EEG to determine if people can recognize such difference as
differences in sound. A measurement system that can measure and
analyze EEG when a subject listens to music were experimentally
developed. And ten subjects were studied with this system. In this
experiment, a WAVE formatted music data and a MP3 compressed
music data that is made from the WAVE formatted data were
prepared. Each subject was made to hear these music sources at the
same volume. From the results of this experiment, clear differences
were confirmed between two wound sources.