Abstract: Lebanon electricity crisis continues to escalate. Rationing hours still apply across the country but with different rates. The capital Beirut is subjected to 3 hours cut while other cities, town and villages may endure 9 to 14 hours of power shortage. To mitigate this situation, private diesel generators distributed illegally all over the country are being used to bridge the gap in power supply. Almost each building in large cities has its own generator and individual villages may have more than one generator supplying their loads. These generators together with their private networks form incomplete and ill-designed and managed microgrids (MG) but can be further developed to become renewable energy-based MG operating in island- or grid-connected modes. This paper will analyze the potential of introducing MG to help resolve the energy crisis in Lebanon. It will investigate the usefulness of developing MG under the prevailing situation of existing private power supply service providers and in light of the developed national energy policy that supports renewable energy development. A case study on a distribution feeder in a rural area will be analyzed using HOMER software to demonstrate the usefulness of introducing photovoltaic (PV) arrays along the existing diesel generators for all the stakeholders; namely, the developers, the customers, the utility and the community at large. Policy recommendations regarding MG development in Lebanon will be presented on the basis of the accumulated experience in private generation and the privatization and public-private partnership laws.
Abstract: This paper presents state estimation with Phasor Measurement Unit (PMU) allocation to obtain complete observability of network. A matrix is designed with modeling of zero injection constraints to minimize PMU allocations. State estimation algorithm is developed with optimal allocation of PMUs to find accurate states of network. The incorporation of PMU into traditional state estimation process improves accuracy and computational performance for large power systems. The nonlinearity integrated with zero injection (ZI) constraints is remodeled to linear frame to optimize number of PMUs. The problem of optimal PMU allocation is regarded with modeling of ZI constraints, PMU loss or line outage, cost factor and redundant measurements. The proposed state estimation with optimal PMU allocation has been compared with traditional state estimation process to show its importance. MATLAB programming on IEEE 14, 30, 57, and 118 bus networks is implemented out by Binary Integer Programming (BIP) method and compared with other methods to show its effectiveness.
Abstract: This study presents a precise relative navigational method for satellites flying in formation using laser-based intermittent measurement data. The measurement data for the relative navigation between two satellites consist of a relative distance measured by a laser instrument and relative attitude angles measured by attitude determination. The relative navigation solutions are estimated by both the Extended Kalman filter (EKF) and unscented Kalman filter (UKF). The solutions estimated by the EKF may become inaccurate or even diverge as measurement outage time gets longer because the EKF utilizes a linearization approach. However, this study shows that the UKF with the appropriate scaling parameters provides a stable and accurate relative navigation solutions despite the long measurement outage time and large initial error as compared to the relative navigation solutions of the EKF. Various navigation results have been analyzed by adjusting the scaling parameters of the UKF.
Abstract: Power system security analysis is the most time demanding process due to large number of possible contingencies that need to be analyzed. In a power system, any contingency resulting in security violation such as line overload or low voltage may occur for a number of reasons at any time. To efficiently rank a contingency, both probability and the extent of security violation must be considered so as not to underestimate the risk associated with the contingency. This paper proposed a contingency ranking method that take into account the probabilistic nature of power system and the severity of contingency by using a newly developed method based on risk factor. The proposed technique is implemented on IEEE 24-bus system.
Abstract: In this paper, we consider the MU-MISO downlink scenario, under imperfect channel state information (CSI). The main issue in imperfect CSI is to keep the probability of each user achievable outage rate below the given threshold level. Such a rate outage constraints present significant and analytical challenges. There are many probabilistic methods are used to minimize the transmit optimization problem under imperfect CSI. Here, decomposition based large deviation inequality and Bernstein type inequality convex restriction methods are used to perform the optimization problem under imperfect CSI. These methods are used for achieving improved output quality and lower complexity. They provide a safe tractable approximation of the original rate outage constraints. Based on these method implementations, performance has been evaluated in the terms of feasible rate and average transmission power. The simulation results are shown that all the two methods offer significantly improved outage quality and lower computational complexity.
Abstract: In this paper, we consider a non-identically independently distributed (non-i.i.d.) Hoyt fading single-input multiple-out put (SIMO) channel, where the transmitter sends some confidential information to the legitimate receiver in presence of an eavesdropper. We formulated the probability of non-zero secrecy mutual information; secure outage probability and average secrecy mutual information (SMI) for the SIMO wireless communication system. The calculation has been carried out using small limit argument approximation (SLAA) on zeroth-order modified Bessel function of first kind. In our proposed model, an eavesdropper observes transmissions of information through another Hoyt fading channel. First, we derived the analytical expression for non-zero secrecy mutual information. Then, we find the secure outage probability to investigate the outage behavior of the proposed model. Finally, we find the average secrecy mutual information. We consider that the channel state information (CSI) is known to legitimate receiver.
Abstract: Although there has been a growing interest in the
hybrid free-space optical link and radio frequency FSO/RF
communication system, the current literature is limited to results
obtained in moderate or cold environment. In this paper, using a soft
switching approach, we investigate the effect of weather
inhomogeneities on the strength of turbulence hence the channel
refractive index under Qatar harsh environment and their influence
on the hybrid FSO/RF availability. In this approach, either FSO/RF
or simultaneous or none of them can be active. Based on soft
switching approach and a finite state Markov Chain (FSMC) process,
we model the channel fading for the two links and derive a
mathematical expression for the outage probability of the hybrid
system. Then, we evaluate the behavior of the hybrid FSO/RF under
hazy and harsh weather. Results show that the FSO/RF soft switching
renders the system outage probability less than that of each link
individually. A soft switching algorithm is being implemented on
FPGAs using Raptor code interfaced to the two terminals of a
1Gbps/100 Mbps FSO/RF hybrid system, the first being implemented
in the region. Experimental results are compared to the above
simulation results.
Abstract: In this paper, we consider a cognitive relay network
(CRN) in which the primary receiver (PR) is protected by peak
transmit power ¯PST and/or peak interference power Q constraints.
In addition, the interference effect from the primary transmitter (PT)
is considered to show its impact on the performance of the CRN. We
investigate the outage probability (OP) and outage capacity (OC) of
the CRN by deriving closed-form expressions over Rayleigh fading
channel. Results show that both the OP and OC improve by increasing
the cooperative relay nodes as well as when the PT is far away from
the SR.
Abstract: At present, the evaluation of voltage stability
assessment experiences sizeable anxiety in the safe operation of
power systems. This is due to the complications of a strain power
system. With the snowballing of power demand by the consumers
and also the restricted amount of power sources, therefore, the system
has to perform at its maximum proficiency. Consequently, the
noteworthy to discover the maximum ability boundary prior to
voltage collapse should be undertaken. A preliminary warning can be
perceived to evade the interruption of power system’s capacity. The
effectiveness of line voltage stability indices (LVSI) is differentiated
in this paper. The main purpose of the indices used is to predict the
proximity of voltage instability of the electric power system. On the
other hand, the indices are also able to decide the weakest load buses
which are close to voltage collapse in the power system. The line
stability indices are assessed using the IEEE 14 bus test system to
validate its practicability. Results demonstrated that the implemented
indices are practically relevant in predicting the manifestation of
voltage collapse in the system. Therefore, essential actions can be
taken to dodge the incident from arising.
Abstract: Electricity spot prices are highly volatile under
optimal generation capacity scenarios due to factors such as nonstorability
of electricity, peak demand at certain periods, generator
outages, fuel uncertainty for renewable energy generators, huge
investments and time needed for generation capacity expansion etc.
As a result market participants are exposed to price and volume risk,
which has led to the development of risk management practices. This
paper provides an overview of risk management practices by market
participants in electricity markets using financial derivatives.
Abstract: Uncertainty of system operating conditions is one of the causative reasons which may render to the instability of a transmission system. For that reason, accurate assessment of transmission reliability margin (TRM) is essential to ensure effective power transfer between areas during the occurrence of system uncertainties. The power transfer is also called as the available transfer capability (ATC) which is the information required by the utilities and marketers to instigate selling and buying the electric energy. This paper proposes a computationally effective approach to estimate TRM and ATC by considering the uncertainties of system cascading collapse and transmission line outages. In accordance to the results that have been obtained, the proposed method is essential for the transmission providers which could help the power marketers and planning sectors in the operation and reserving transmission services based on the ATC calculated.
Abstract: Various studies have showed that about 90% of single line to ground faults occurred on High voltage transmission lines have transient nature. This type of faults is cleared by temporary outage (by the single phase auto-reclosure). The interval between opening and reclosing of the faulted phase circuit breakers is named “Dead Time” that is varying about several hundred milliseconds. For adjustment of traditional single phase auto-reclosures that usually are not intelligent, it is necessary to calculate the dead time in the off-line condition precisely. If the dead time used in adjustment of single phase auto-reclosure is less than the real dead time, the reclosing of circuit breakers threats the power systems seriously. So in this paper a novel approach for precise calculation of dead time in power transmission lines based on the network equivalencing in time domain is presented. This approach has extremely higher precision in comparison with the traditional method based on Thevenin equivalent circuit. For comparison between the proposed approach in this paper and the traditional method, a comprehensive simulation by EMTP-ATP is performed on an extensive power network.
Abstract: This paper presents a novel Global Navigation Satellite System (GNSS) Avionics Based Integrity Augmentation (ABIA) system architecture suitable for civil and military air platforms, including Unmanned Aircraft Systems (UAS). Taking the move from previous research on high-accuracy Differential GNSS (DGNSS) systems design, integration and experimental flight test activities conducted at the Italian Air Force Flight Test Centre (CSV-RSV), our research focused on the development of a novel approach to the problem of GNSS ABIA for mission- and safety-critical air vehicle applications and for multi-sensor avionics architectures based on GNSS. Detailed mathematical models were developed to describe the main causes of GNSS signal outages and degradation in flight, namely: antenna obscuration, multipath, fading due to adverse geometry and Doppler shift. Adopting these models in association with suitable integrity thresholds and guidance algorithms, the ABIA system is able to generate integrity cautions (predictive flags) and warnings (reactive flags), as well as providing steering information to the pilot and electronic commands to the aircraft/UAS flight control systems. These features allow real-time avoidance of safety-critical flight conditions and fast recovery of the required navigation performance in case of GNSS data losses. In other words, this novel ABIA system addresses all three cornerstones of GNSS integrity augmentation in mission- and safety-critical applications: prediction (caution flags), reaction (warning flags) and correction (alternate flight path computation).
Abstract: This paper discusses aspects of outages in the electric transmission network in the Kosovo Power System caused by the atmospheric discharges.
Frequency and location of the atmospheric discharges in Kosovo territory will be provided by a lightning location system ALARM (Automated Lightning Alert and Risk Management) and from the data from the Meteorological Department in Prishtina International Airport. These data will be used to make comparisons with the actual outages registered in the Kosovo Power System from the Kosovo Transmission, systems and market operator (KOSTT) during a specific time period.
The lines with the worst performance determined, regarding the atmospheric discharges, will be choose for further discussions in terms of over voltages caused by the direct or indirect lightning strokes.
Recommendations for protection in terms of insulator coordination and surge arresters will be given at the end and in this stage dynamic simulation will take part.
Abstract: An electric utility-s main concern is to plan, design, operate and maintain its power supply to provide an acceptable level of reliability to its users. This clearly requires that standards of reliability be specified and used in all three sectors of the power system, i.e., generation, transmission and distribution. That is why reliability of a power system is always a major concern to power system planners. This paper presents the reliability analysis of Bangladesh Power System (BPS). Reliability index, loss of load probability (LOLP) of BPS is evaluated using recursive algorithm and considering no de-rated states of generators. BPS has sixty one generators and a total installed capacity of 5275 MW. The maximum demand of BPS is about 5000 MW. The relevant data of the generators and hourly load profiles are collected from the National Load Dispatch Center (NLDC) of Bangladesh and reliability index 'LOLP' is assessed for the period of last ten years.
Abstract: Cooperative diversity (CD) has been adopted in many communication systems because it helps in improving performance of the wireless communication systems with the help of the relays that emulate the multiple antenna terminals. This work aims to provide the derivation of the performance analysis expressions of the multiuser diversity (MUD) in the two-hop cooperative multi-relay wireless networks (TCMRNs). Considering the work analysis, we provide analytically the derivation of a closed form expression of the two most commonly used performance metrics namely, the outage probability and the symbol error probability (SEP) for the fixed decode-and-forward (FDF) protocol with MUD.
Abstract: Diagnostic goal of transformers in service is to detect the winding or the core in fault. Transformers are valuable equipment which makes a major contribution to the supply security of a power system. Consequently, it is of great importance to minimize the frequency and duration of unwanted outages of power transformers. So, Frequency Response Analysis (FRA) is found to be a useful tool for reliable detection of incipient mechanical fault in a transformer, by finding winding or core defects. The authors propose as first part of this article, the coupled circuits method, because, it gives most possible exhaustive modelling of transformers. And as second part of this work, the application of FRA in low frequency in order to improve and simplify the response reading. This study can be useful as a base data for the other transformers of the same categories intended for distribution grid.
Abstract: This paper proposes a Wavelength Division
Multiplexing (WDM) technology based Storage Area Network
(SAN) for all type of Disaster recovery operation. It considers
recovery when all paths failure in the network as well as the main
SAN site failure also the all backup sites failure by the effect of
natural disasters such as earthquakes, fires and floods, power outage,
and terrorist attacks, as initially SAN were designed to work within
distance limited environments[2]. Paper also presents a NEW PATH
algorithm when path failure occurs. The simulation result and
analysis is presented for the proposed architecture with performance
consideration.
Abstract: Most integrated inertial navigation systems (INS) and
global positioning systems (GPS) have been implemented using the
Kalman filtering technique with its drawbacks related to the need for
predefined INS error model and observability of at least four
satellites. Most recently, a method using a hybrid-adaptive network
based fuzzy inference system (ANFIS) has been proposed which is
trained during the availability of GPS signal to map the error
between the GPS and the INS. Then it will be used to predict the
error of the INS position components during GPS signal blockage.
This paper introduces a genetic optimization algorithm that is used to
update the ANFIS parameters with respect to the INS/GPS error
function used as the objective function to be minimized. The results
demonstrate the advantages of the genetically optimized ANFIS for
INS/GPS integration in comparison with conventional ANFIS
specially in the cases of satellites- outages. Coping with this problem
plays an important role in assessment of the fusion approach in land
navigation.
Abstract: In this paper, a Gaussian multiple input multiple output multiple eavesdropper (MIMOME) channel is considered where a transmitter communicates to a receiver in the presence of an eavesdropper. We present a technique for determining the secrecy capacity of the multiple input multiple output (MIMO) channel under Gaussian noise. We transform the degraded MIMOME channel into multiple single input multiple output (SIMO) Gaussian wire-tap channels and then use scalar approach to convert it into two equivalent multiple input single output (MISO) channels. The secrecy capacity model is then developed for the condition where the channel state information (CSI) for main channel only is known to the transmitter. The results show that the secret communication is possible when the eavesdropper channel noise is greater than a cutoff noise level. The outage probability is also analyzed of secrecy capacity is also analyzed. The effect of fading and outage probability is also analyzed.