Abstract: Charge Simulation Method (CSM) is one of the very widely used numerical field computation technique in High Voltage (HV) engineering. The high voltage fields of varying non uniformities are encountered in practice. CSM programs being case specific, the simulation accuracies heavily depend on the user (programmers) experience. Here is an effort to understand CSM errors and evolve some guidelines to setup accurate CSM models, relating non uniformities with assignment factors. The results are for the six-point-charge model of sphere-plane gap geometry. Using genetic algorithm (GA) as tool, optimum assignment factors at different non uniformity factors for this model have been evaluated and analyzed. It is shown that the symmetrically placed six-point-charge models can be good enough to set up CSM programs with potential errors less than 0.1% when the field non uniformity factor is greater than 2.64 (field utilization factor less than 52.76%).
Abstract: The development of the power electronics has allowed
increasing the precision and reliability of the electrical trainings,
thanks to the adjustable inverters, as the Pulse Wide Modulation
(PWM) five level inverters, which is the object of study in this
article.The authors treat the relation between the law order adopted for
a given system and the oscillations of the electrical and mechanical
parameters of which the tolerance depends on the process with which
they are integrated (paper factory, lifting of the heavy loads,
etc.).Thus the best choice of the regulation indexes allows us to
achieve stability and safety training without investment (management
of existing equipment).
Abstract: In recent years, it has been proposed security
architecture for sensor network.[2][4]. One of these, TinySec by Chris
Kalof, Naveen Sastry, David Wagner had proposed Link layer security
architecture, considering some problems of sensor network. (i.e :
energy, bandwidth, computation capability,etc). The TinySec employs
CBC_mode of encryption and CBC-MAC for authentication based on
SkipJack Block Cipher. Currently, This TinySec is incorporated in the
TinyOS for sensor network security.
This paper introduces TinyHash based on general hash algorithm.
TinyHash is the module in order to replace parts of authentication and
integrity in the TinySec. it implies that apply hash algorithm on
TinySec architecture. For compatibility about TinySec, Components
in TinyHash is constructed as similar structure of TinySec. And
TinyHash implements the HMAC component for authentication and
the Digest component for integrity of messages. Additionally, we
define the some interfaces for service associated with hash algorithm.
Abstract: This paper presents a new Hybrid Fuzzy (HF) PID type controller based on Genetic Algorithms (GA-s) for solution of the Automatic generation Control (AGC) problem in a deregulated electricity environment. In order for a fuzzy rule based control system to perform well, the fuzzy sets must be carefully designed. A major problem plaguing the effective use of this method is the difficulty of accurately constructing the membership functions, because it is a computationally expensive combinatorial optimization problem. On the other hand, GAs is a technique that emulates biological evolutionary theories to solve complex optimization problems by using directed random searches to derive a set of optimal solutions. For this reason, the membership functions are tuned automatically using a modified GA-s based on the hill climbing method. The motivation for using the modified GA-s is to reduce fuzzy system effort and take large parametric uncertainties into account. The global optimum value is guaranteed using the proposed method and the speed of the algorithm-s convergence is extremely improved, too. This newly developed control strategy combines the advantage of GA-s and fuzzy system control techniques and leads to a flexible controller with simple stricture that is easy to implement. The proposed GA based HF (GAHF) controller is tested on a threearea deregulated power system under different operating conditions and contract variations. The results of the proposed GAHF controller are compared with those of Multi Stage Fuzzy (MSF) controller, robust mixed H2/H∞ and classical PID controllers through some performance indices to illustrate its robust performance for a wide range of system parameters and load changes.
Abstract: An acoustic emission (AE) technique is useful for
detection of partial discharges (PDs) at a joint and a terminal section of
a cross-linked polyethylene (XLPE) cable. For AE technique, it is not
difficult to detect a PD using AE sensors. However, it is difficult to
grasp whether the detected AE signal is owing to a single discharge or
not. Additionally, when an AE technique is applied at a terminal
section of a XLPE cable in salt pollution district, for example, there is
possibility of detection of AE signals owing to creeping discharges on
the surface of electric power apparatus. In this study, we evaluated AE
signals in order to grasp what kind of information we can get from
detected AE signals. The results showed that envelop detection of AE
signal and a period which some AE signals were continuously detected
were good indexes for estimating state-of-discharge.
Abstract: This paper presents a new technique of compensation
of the effect of variation parameters in the direct field oriented
control of induction motor. The proposed method uses an adaptive
tuning of the value of synchronous speed to obtain the robustness for
the field oriented control. We show that this adaptive tuning allows
having robustness for direct field oriented control to changes in rotor
resistance, load torque and rotational speed. The effectiveness of the
proposed control scheme is verified by numerical simulations. The
numerical validation results of the proposed scheme have presented
good performances compared to the usual direct-field oriented
control.
Abstract: A robust control approach is proposed for a high speed manipulator using a hybrid computed torque control approach in the state space. The high-speed manipulator is driven by permanent magnet dc motors to track a trajectory in the joint space in the presence of disturbances. Tracking problem is analyzed in the state space where the completed models are considered for actuators. The proposed control approach can guarantee the stability and a satisfactory tracking performance. A two-link elbow manipulator driven by electrical actuators is simulated and results are shown to satisfy conditions under technical specifications.
Abstract: Sonogram images of normal and lymphocyte thyroid tissues have considerable overlap which makes it difficult to interpret and distinguish. Classification from sonogram images of thyroid gland is tackled in semiautomatic way. While making manual diagnosis from images, some relevant information need not to be recognized by human visual system. Quantitative image analysis could be helpful to manual diagnostic process so far done by physician. Two classes are considered: normal tissue and chronic lymphocyte thyroid (Hashimoto's Thyroid). Data structure is analyzed using K-nearest-neighbors classification. This paper is mentioned that unlike the wavelet sub bands' energy, histograms and Haralick features are not appropriate to distinguish between normal tissue and Hashimoto's thyroid.
Abstract: This paper deals with modeling and parameter
identification of nonlinear systems described by Hammerstein model
having Piecewise nonlinear characteristics such as Dead-zone
nonlinearity characteristic. The simultaneous use of both an easy
decomposition technique and the triangular basis functions leads to a
particular form of Hammerstein model. The approximation by using
Triangular basis functions for the description of the static nonlinear
block conducts to a linear regressor model, so that least squares
techniques can be used for the parameter estimation. Singular Values
Decomposition (SVD) technique has been applied to separate the
coupled parameters. The proposed approach has been efficiently
tested on academic examples of simulation.
Abstract: In this treatise we will study the capability of static
compensator for reactive power to stabilize sheen voltage with motor
loading on power networks system. We also explain the structure and main function of STATCOM and the method to control it using STATCOM transformer current to simultaneously predict after
telling about the necessity of FACTS tools to compensate in power networks. Then we study topology and controlling system to stabilize
voltage during start of inductive motor. The outcome of stimulat by MATLAB software supports presented controlling idea and
system in the treatise.
Abstract: A bond graph model of an electrical transformer
including the nonlinear saturation is presented. A nonlinear observer for the transformer based on multivariable circle
criterion in the physical domain is proposed. In order to show the saturation and hysteresis effects on the electrical transformer,
simulation results are obtained. Finally, the paper describes that convergence of the estimates to the true states is achieved.
Abstract: this paper presents an auto-regressive network called the Auto-Regressive Multi-Context Recurrent Neural Network (ARMCRN), which forecasts the daily peak load for two large power plant systems. The auto-regressive network is a combination of both recurrent and non-recurrent networks. Weather component variables are the key elements in forecasting because any change in these variables affects the demand of energy load. So the AR-MCRN is used to learn the relationship between past, previous, and future exogenous and endogenous variables. Experimental results show that using the change in weather components and the change that occurred in past load as inputs to the AR-MCRN, rather than the basic weather parameters and past load itself as inputs to the same network, produce higher accuracy of predicted load. Experimental results also show that using exogenous and endogenous variables as inputs is better than using only the exogenous variables as inputs to the network.
Abstract: This paper deals with stability analysis for synchronous reluctance motors drive. Special attention is paid to the transient performance with variations in motor's parameters such as Ld and Rs. A study of the dynamic control using d-q model is presented first in order to clarify the stability of the motor drive system. Based on the experimental parameters of the synchronous reluctance motor, this paper gives some simulation results using MATLAB/SIMULINK software packages. It is concluded that the motor parameters, especially Ld, affect the estimator stability and hence the whole drive system.
Abstract: German electricity European options on futures using
Lévy processes for the underlying asset are examined. Implied
volatility evolution, under each of the considered models, is
discussed after calibrating for the Merton jump diffusion (MJD),
variance gamma (VG), normal inverse Gaussian (NIG), Carr, Geman,
Madan and Yor (CGMY) and the Black and Scholes (B&S) model.
Implied volatility is examined for the entire sample period, revealing
some curious features about market evolution, where data fitting
performances of the five models are compared. It is shown that
variance gamma processes provide relatively better results and that
implied volatility shows significant differences through time, having
increasingly evolved. Volatility changes for changed uncertainty, or
else, increasing futures prices and there is evidence for the need to
account for seasonality when modelling both electricity spot/futures
prices and volatility.
Abstract: Recently, the Spherical Motion Models (SMM-s) have been introduced [1]. These new models have been developed for 3D local landmark-base Autonomous Navigation (AN). This paper is revealing new arguments and experimental results to support the SMM-s characteristics. The accuracy and the robustness in performing a specific task are the main concerns of the new investigations. To analyze their performances of the SMM-s, the most powerful tools of estimation theory, the extended Kalman filter (EKF) and unscented Kalman filter (UKF), which give the best estimations in noisy environments, have been employed. The Monte Carlo validation implementations used to test the stability and robustness of the models have been employed as well.
Abstract: A new design approach for three-stage operational
amplifiers (op-amps) is proposed. It allows to actually implement a
symmetrical push-pull class-AB amplifier output stage for wellestablished
three-stage amplifiers using a feedforward
transconductance stage. Compared with the conventional design
practice, the proposed approach leads to a significant
improvement of the symmetry between the positive and the
negative op-amp step response, resulting in similar values of the
positive/negative settling time. The new approach proves to be very
useful in order to fully exploit the potentiality allowed by the op-amp
in terms of speed performances. Design examples in a commercial
0.35-μm CMOS prove the effectiveness of theproposed strategy.
Abstract: Operating a device at high power and high frequency
is a major problem because wall losses greatly reduce the efficiency
of the device. In the present communication, authors analytically
analyzed the dependence of ohmic/RF efficiency, the fraction of
output power with respect to the total power generated, of gyrotron
cavity structure on the conductivity of copper for the second
harmonic TE0,6 mode. This study shows a rapid fall in the RF
efficiency as the quality (conductivity) of copper degrades. Starting
with an RF efficiency near 40% at the conductivity of ideal copper
(5.8 x 107 S/m), the RF efficiency decreases (upto 8%) as the copper
quality degrades. Assuming conductivity half that of ideal copper the
RF efficiency as a function of diffractive quality factor, Qdiff, has
been studied. Here the RF efficiency decreases rapidly with
increasing diffractive Q. Ohmic wall losses as a function of
frequency for 460 GHz gyrotron cavity excited in TE0,6 mode has
also been analyzed. For 460 GHz cavity, the extracted power is
reduced to 32% of the generated power due to ohmic losses in the
walls of the cavity.
Abstract: A high-linearity and high-speed current-mode sampleand-
hold circuit is designed and simulated using a 0.25μm CMOS
technology. This circuit design is based on low voltage and it utilizes
a fully differential circuit. Due to the use of only two switches the
switch related noise has been reduced. Signal - dependent -error is
completely eliminated by a new zero voltage switching technique.
The circuit has a linearity error equal to ±0.05μa, i.e. 12-bit
accuracy with a ±160 μa differential output - input signal frequency
of 5MHZ, and sampling frequency of 100 MHZ. Third
harmonic is equal to –78dB.
Abstract: The power system network is becoming more
complex nowadays and it is very difficult to maintain the stability
of the system. Today-s enhancement of technology makes it
possible to include new energy storage devices in the electric
power system. In addition, with the aid of power electronic
devices, it is possible to independently exchange active and
reactive power flow with the utility grid. The main purpose of this
paper proposes a Proportional – Integral (PI) control based 48 –
pulse Inverter based Static Synchronous Series Compensator
(SSSC) with and without Superconducting Magnetic Energy
Storage (SMES) used for enhancing the transient stability and
regulating power flow in automatic mode. Using a test power
system through the dynamic simulation in Matlab/Simulink
platform validates the performance of the proposed SSSC with and
without SMES system.
Abstract: In this study, the performance of a high-frequency arc
welding machine including a two-switch inverter is analyzed. The
control of the system is achieved using two different control
techniques i- fuzzy logic control (FLC) ii- state space averaging
based sliding control. Fuzzy logic control does not need accurate
mathematical model of a plant and can be used in nonlinear
applications. The second method needs the mathematical model of
the system. In this method the state space equations of the system are
derived for two different “on" and “off" states of the switches. The
derived state equations are combined with the sliding control rule
considering the duty-cycle of the converter. The performance of the
system is analyzed by simulating the system using SIMULINK tool
box of MATLAB. The simulation results show that fuzzy logic
controller is more robust and less sensitive to parameter variations.