Abstract: It is known that if harmonic spectra are decreased, then
acoustic noise also decreased. Hence, this paper deals with a new
random switching strategy using DSP TMS320F2812 to decrease the
harmonics spectra of single phase switched reluctance motor. The
proposed method which combines random turn-on, turn-off angle
technique and random pulse width modulation technique is shown. A
harmonic spread factor (HSF) is used to evaluate the random
modulation scheme. In order to confirm the effectiveness of the new
method, the experimental results show that the harmonic intensity of
output voltage for the proposed method is better than that for
conventional methods.
Abstract: Versatile dual-mode class-AB CMOS four-quadrant
analog multiplier circuit is presented. The dual translinear loops and
current mirrors are the basic building blocks in realization scheme.
This technique provides; wide dynamic range, wide-bandwidth response
and low power consumption. The major advantages of this
approach are; its has single ended inputs; since its input is dual translinear
loop operate in class-AB mode which make this multiplier
configuration interesting for low-power applications; current multiplying,
voltage multiplying, or current and voltage multiplying can
be obtainable with balanced input. The simulation results of versatile
analog multiplier demonstrate a linearity error of 1.2 %, a -3dB bandwidth
of about 19MHz, a maximum power consumption of 0.46mW,
and temperature compensated. Operation of versatile analog multiplier
was also confirmed through an experiment using CMOS transistor
array.
Abstract: The purpose of this study was to evaluate and
compare new indices based on the discrete wavelet transform
with another spectral parameters proposed in the literature as
mean average voltage, median frequency and ratios between
spectral moments applied to estimate acute exercise-induced
changes in power output, i.e., to assess peripheral muscle
fatigue during a dynamic fatiguing protocol. 15 trained
subjects performed 5 sets consisting of 10 leg press, with 2
minutes rest between sets. Surface electromyography was
recorded from vastus medialis (VM) muscle. Several surface
electromyographic parameters were compared to detect
peripheral muscle fatigue. These were: mean average voltage
(MAV), median spectral frequency (Fmed), Dimitrov spectral
index of muscle fatigue (FInsm5), as well as other five
parameters obtained from the discrete wavelet transform
(DWT) as ratios between different scales. The new wavelet
indices achieved the best results in Pearson correlation
coefficients with power output changes during acute dynamic
contractions. Their regressions were significantly different
from MAV and Fmed. On the other hand, they showed the
highest robustness in presence of additive white gaussian
noise for different signal to noise ratios (SNRs). Therefore,
peripheral impairments assessed by sEMG wavelet indices
may be a relevant factor involved in the loss of power output
after dynamic high-loading fatiguing task.
Abstract: This paper investigates and compares performance of
various conventional and fuzzy logic based controllers at generator
locations for oscillation damping. Performance of combination of
conventional and fuzzy logic based controllers also studied by
comparing overshoot on the active power deviation response for a
small disturbance and damping ratio of the critical mode. Fuzzy logic
based controllers can not be modeled in the state space form to get
the eigenvalues and corresponding damping ratios of various modes
of generators and controllers. Hence, a new method based on tracing
envelop of time domain waveform is also presented and used in the
paper for comparing performance of controllers. The paper also
shows that if the fuzzy based controllers designed separately
combining them could not lead to a better performance.
Abstract: Installation of power compensation equipment in
some cases places additional buses into the system. Therefore, a total
number of power flow equations and voltage unknowns increase due
to additional locations of installed devices. In this circumstance, power flow calculation is more complicated. It may result in a
computational convergence problem. This paper presents a power flow calculation by using Newton-Raphson iterative method together
with the proposed load transfer technique. This concept is to eliminate additional buses by transferring installed loads at the new buses to existing two adjacent buses. Thus, the total number of power
flow equations is not changed. The overall computational speed is
expectedly shorter than that of solving the problem without applying the load transfer technique. A 15-bus test system is employed for test
to evaluate the effectiveness of the proposed load transfer technique. As a result, the total number of iteration required and execution time
is significantly reduced.
Abstract: We demonstrate a 1×4 coarse wavelength
division-multiplexing (CWDM) planar concave grating
multiplexer/demultiplexer and its application in re-configurable
optical add/drop multiplexer (ROADM) system in silicon-on-insulator
substrate. The wavelengths of the demonstrated concave grating
multiplexer align well with the ITU-T standard. We demonstrate a
prototype of ROADM comprising two such concave gratings and four
wide-band thermo-optical MZI switches. Undercut technology which
removes the underneath silicon substrate is adopted in optical switches
in order to minimize the operation power. For all the thermal heaters,
the operation voltage is smaller than 1.5 V, and the switch power is
~2.4 mW. High throughput pseudorandom binary sequence (PRBS)
data transmission with up to 100 Gb/s is demonstrated, showing the
high-performance ROADM functionality.
Abstract: When a high DC voltage is applied to a capacitor with
strongly asymmetrical electrodes, it generates a mechanical force that
affects the whole capacitor. This is caused by the motion of ions generated around the smaller of the two electrodes and their subsequent interaction with the surrounding medium. If one of the electrodes is heated, it changes the conditions around the capacitor
and influences the process of ionisation, thus changing the value of the generated force. This paper describes these changes and gives
reasons behind them. Further the experimental results are given as proof of the ionic mechanism of the phenomenon.
Abstract: This article presents a voltage-mode universal
biquadratic filter performing simultaneous 3 standard functions: lowpass,
high-pass and band-pass functions, employing differential
different current conveyor (DDCC) and current controlled current
conveyor (CCCII) as active element. The features of the circuit are
that: the quality factor and pole frequency can be tuned independently
via the input bias currents: the circuit description is very simple,
consisting of 1 DDCC, 2 CCCIIs, 2 electronic resistors and 2
grounded capacitors. Without requiring component matching
conditions, the proposed circuit is very appropriate to further develop
into an integrated circuit. The PSPICE simulation results are
depicted. The given results agree well with the theoretical
anticipation.
Abstract: The prologue of new High Voltage (HV) transmission
mains into the community necessitates earthing design to ensure
safety compliance of the system. Conductive structures such as steel
or concrete poles are widely used in HV transmission mains. The
earth potential rise (EPR) generated by a fault on these structures
could result to an unsafe condition. This paper discusses information
on the input impedance of the over head earth wire (OHEW) system
for finite and infinite transmission mains. The definition of finite and
infinite system is discussed, maximum EPR due to pole fault. The
simplified equations for EPR assessments are introduced and
discussed for the finite and infinite conditions. A case study is also
shown.
Abstract: This paper presents a fast and efficient on-line technique for estimating impedance of unbalanced loads in power systems. The proposed technique is an application of a discrete timedynamic filter based on stochastic estimation theory which is suitable for estimating parameters in noisy environment. The algorithm uses sets of digital samples of the distorted voltage and current waveforms of the non-linear load to estimate the harmonic contents of these two signal. The non-linear load impedance is then calculated from these contents. The method is tested using practical data. Results are reported and compared with those obtained using the conventional least error squares technique. In addition to the very accurate results obtained, the method can detect and reject bad measurements. This can be considered as a very important advantage over the conventional static estimation methods such as the least error square method.
Abstract: A current mirror (CM) based on self cascode MOSFETs low voltage analog and mixed mode structures has been proposed. The proposed CM has high output impedance and can operate at 0.5 V. P-Spice simulations confirm the high performance of this CM with a bandwidth of 6.0 GHz at input current of 100 μA.
Abstract: As new challenges emerge in power electrical
workplace safety, it is the responsibility of the systems designer to
seek out new approaches and solutions that address them. Design
decisions made today will impact cost, safety and serviceability of
the installed systems for 40 or 50 years during the useful life for the
owner. Studies have shown that this cost is an order of magnitude of
7 to 10 times the installed cost of the power distribution equipment.
This paper reviews some aspects of earthing system design in power
substation surrounded by residential houses. The electrical potential
rise and split factors are discussed and a few recommendations are
provided to achieve a safety voltage in the area beyond the boundary
of the substation.
Abstract: In this paper, the application of GRNN in
modeling of SOFC fuel cells were studied. The parameters
are of interested as voltage and power value and the current
changes are investigated. In addition, the comparison between
GRNN neural network application and conventional method
was made. The error value showed the superlative results.
Abstract: This paper presents a novel control strategy of a threephase
four-wire Unified Power Quality (UPQC) for an improvement
in power quality. The UPQC is realized by integration of series and
shunt active power filters (APFs) sharing a common dc bus capacitor.
The shunt APF is realized using a thee-phase, four leg voltage source
inverter (VSI) and the series APF is realized using a three-phase,
three leg VSI. A control technique based on unit vector template
technique (UTT) is used to get the reference signals for series APF,
while instantaneous sequence component theory (ISCT) is used for
the control of Shunt APF. The performance of the implemented
control algorithm is evaluated in terms of power-factor correction,
load balancing, neutral source current mitigation and mitigation of
voltage and current harmonics, voltage sag and swell in a three-phase
four-wire distribution system for different combination of linear and
non-linear loads. In this proposed control scheme of UPQC, the
current/voltage control is applied over the fundamental supply
currents/voltages instead of fast changing APFs currents/voltages,
there by reducing the computational delay and the required sensors.
MATLAB/Simulink based simulations are obtained, which support
the functionality of the UPQC. MATLAB/Simulink based
simulations are obtained, which support the functionality of the
UPQC.
Abstract: In this paper, a modified CCCII is presented. We have used a current mirror with low supply voltage. This circuit is operated at low supply voltage of ±1V. Tspice simulations for TSMC 0.18μm CMOS Technology has shown that the current and voltage bandwidth are respectively 3.34GHz and 4.37GHz, and parasitic resistance at port X has a value of 169.320 for a control current of 120μA. In order to realize this circuit, we have implemented in this first step a universal current mode filter where the frequency can reach the 134.58MHz. In the second step, we have implemented two simulated inductors: one floating and the other grounded. These two inductors are operated in high frequency and variable depending on bias current I0. Finally, we have used the two last inductors respectively to implement two sinusoidal oscillators domains of frequencies respectively: [470MHz, 692MHz], and [358MHz, 572MHz] for bias currents I0 [80μA, 350μA].