Abstract: High moisture content in fruits generates post-harvest
problems such as mechanical, biochemical, microbial and physical
losses. Dehydration, which is based on the reduction of water activity
of the fruit, is a common option for overcoming such losses.
However, regular hot air drying could affect negatively the quality
properties of the fruit due to the long residence time at high
temperature. Power ultrasound (US) application during the
convective drying has been used as a novel method able to enhance
drying rate and, consequently, to decrease drying time. In the present
study, a new approach was tested to evaluate the effect of US on the
drying time, the final antioxidant activity (AA) and the total
polyphenol content (TPC) of banana slices (BS), mango slices (MS)
and guava slices (GS). There were also studied the drying kinetics
with nine different models from which water effective diffusivities
(Deff) (with or without shrinkage corrections) were calculated.
Compared with the corresponding control tests, US assisted drying
for fruit slices showed reductions in drying time between 16.23 and
30.19%, 11.34 and 32.73%, and 19.25 and 47.51% for the MS, BS
and GS respectively. Considering shrinkage effects, Deff calculated
values ranged from 1.67*10-10 to 3.18*10-10 m2/s, 3.96*10-10 and
5.57*10-10 m2/s and 4.61*10-10 to 8.16*10-10 m2/s for the BS, MS and
GS samples respectively. Reductions of TPC and AA (as DPPH)
were observed compared with the original content in fresh fruit data
in all kinds of drying assays.
Abstract: Nonlinear evolution of broadband ultrasonic pulses
passed through the rock specimens is studied using the apparatus
“GEOSCAN-02M”. Ultrasonic pulses are excited by the pulses of Qswitched
Nd:YAG laser with the time duration of 10 ns and with the
energy of 260 mJ. This energy can be reduced to 20 mJ by some light
filters. The laser beam radius did not exceed 5 mm. As a result of the
absorption of the laser pulse in the special material – the optoacoustic
generator–the pulses of longitudinal ultrasonic waves are excited with
the time duration of 100 ns and with the maximum pressure
amplitude of 10 MPa. The immersion technique is used to measure
the parameters of these ultrasonic pulses passed through a specimen,
the immersion liquid is distilled water. The reference pulse passed
through the cell with water has the compression and the rarefaction
phases. The amplitude of the rarefaction phase is five times lower
than that of the compression phase. The spectral range of the
reference pulse reaches 10 MHz. The cubic-shaped specimens of the
Karelian gabbro are studied with the rib length 3 cm. The ultimate
strength of the specimens by the uniaxial compression is (300±10)
MPa. As the reference pulse passes through the area of the specimen
without cracks the compression phase decreases and the rarefaction
one increases due to diffraction and scattering of ultrasound, so the
ratio of these phases becomes 2.3:1. After preloading some horizontal
cracks appear in the specimens. Their location is found by one-sided
scanning of the specimen using the backward mode detection of the
ultrasonic pulses reflected from the structure defects. Using the
computer processing of these signals the images are obtained of the
cross-sections of the specimens with cracks. By the increase of the
reference pulse amplitude from 0.1 MPa to 5 MPa the nonlinear
transformation of the ultrasonic pulse passed through the specimen
with horizontal cracks results in the decrease by 2.5 times of the
amplitude of the rarefaction phase and in the increase of its duration
by 2.1 times. By the increase of the reference pulse amplitude from 5
MPa to 10 MPa the time splitting of the phases is observed for the
bipolar pulse passed through the specimen. The compression and
rarefaction phases propagate with different velocities. These features
of the powerful broadband ultrasonic pulses passed through the rock
specimens can be described by the hysteresis model of Preisach-
Mayergoyz and can be used for the location of cracks in the optically
opaque materials.
Abstract: In this paper, we present a new segmentation approach
for focal liver lesions in contrast enhanced ultrasound imaging. This
approach, based on a two-cluster Fuzzy C-Means methodology,
considers type-II fuzzy sets to handle uncertainty due to the image
modality (presence of speckle noise, low contrast, etc.), and to
calculate the optimum inter-cluster threshold. Fine boundaries are
detected by a local recursive merging of ambiguous pixels. The
method has been tested on a representative database. Compared to
both Otsu and type-I Fuzzy C-Means techniques, the proposed
method significantly reduces the segmentation errors.
Abstract: Background: Muscle Energy Techniques (MET) have
been widely used by manual therapists over the past years, but still
limited research validated its use and there was limited evidence to
substantiate the theories used to explain its effects. Objective: To
investigate the effect of Muscle Energy Technique (MET) on anterior
pelvic tilt in patients with lumbar spondylosis. Design: Randomized
controlled trial. Subjects: Thirty patients with anterior pelvic tilt from
both sexes were involved, aged between 35 to 50 years old and they
were divided into MET and control groups with 15 patients in each.
Methods: All patients received 3sessions/week for 4 weeks where the
study group received MET, Ultrasound and Infrared, and the control
group received U.S and I.R only. Pelvic angle was measured by
palpation meter, pain severity by the visual analogue scale and
functional disabilities by the Oswestry disability index. Results: Both
groups showed significant improvement in all measured variables.
The MET group was significantly better than the control group in
pelvic angle, pain severity, and functional disability as p-value were
(0.001, 0.0001, 0.0001) respectively. Conclusion and implication: the
study group fulfilled greater improvement in all measured variables
than the control group which implies that application of MET in
combination with U.S and I.R were more effective in improving
pelvic tilting angle, pain severity and functional disabilities than
using electrotherapy only.
Abstract: We present a gas-liquid microfluidic system as a
reactor to obtain magnetite nanoparticles with an excellent degree of
control regarding their crystalline phase, shape and size. Several
types of microflow approaches were selected to prevent nanomaterial
aggregation and to promote homogenous size distribution. The
selected reactor consists of a mixer stage aided by ultrasound waves
and a reaction stage using a N2-liquid segmented flow to prevent
magnetite oxidation to non-magnetic phases. A milli-fluidic reactor
was developed to increase the production rate where a magnetite
throughput close to 450 mg/h in a continuous fashion was obtained.
Abstract: The paper presents a novel screening method to
indicate congenital heart diseases (CHD), which otherwise could
remain undetected because of their low level. Therefore, not
belonging to the high-risk population, the pregnancies are not subject
to the regular fetal monitoring with ultrasound echocardiography.
Based on the fact that CHD is a morphological defect of the heart
causing turbulent blood flow, the turbulence appears as a murmur,
which can be detected by fetal phonocardiography (fPCG). The
proposed method applies measurements on the maternal abdomen
and from the recorded sound signal a sophisticated processing
determines the fetal heart murmur. The paper describes the problems
and the additional advantages of the fPCG method including the
possibility of measurements at home and its combination with the
prescribed regular cardiotocographic (CTG) monitoring. The
proposed screening process implemented on a telemedicine system
provides an enhanced safety against hidden cardiac diseases.
Abstract: Non contact evaluation of the thickness of paint
coatings can be attempted by different destructive and nondestructive
methods such as cross-section microscopy, gravimetric mass
measurement, magnetic gauges, Eddy current, ultrasound or
terahertz. Infrared thermography is a nondestructive and non-invasive
method that can be envisaged as a useful tool to measure the surface
thickness variations by analyzing the temperature response. In this
paper, the thermal quadrupole method for two layered samples heated
up with a pulsed excitation is firstly used. By analyzing the thermal
responses as a function of thermal properties and thicknesses of both
layers, optimal parameters for the excitation source can be identified.
Simulations show that a pulsed excitation with duration of ten
milliseconds allows obtaining a substrate-independent thermal
response. Based on this result, an experimental setup consisting of a
near-infrared laser diode and an Infrared camera was next used to
evaluate the variation of paint coating thickness between 60 μm and
130 μm on two samples. Results show that the parameters extracted
for thermal images are correlated with the estimated thicknesses by
the Eddy current methods. The laser pulsed thermography is thus an
interesting alternative nondestructive method that can be moreover
used for nonconductive substrates.
Abstract: The ultrasound imaging is very popular to diagnosis
the disease because of its non-invasive nature. The ultrasound
imaging slowly produces low quality images due to the presence of
spackle noise and wave interferences. There are several algorithms to
be proposed for the segmentation of ultrasound carotid artery images
but it requires a certain limit of user interaction. The pixel in an
image is highly correlated so the spatial information of surrounding
pixels may be considered in the process of image segmentation which
improves the results further. When data is highly correlated, one pixel
may belong to more than one cluster with different degree of
membership. There is an important step to computerize the evaluation
of arterial disease severity using segmentation of carotid artery lumen
in 2D and 3D ultrasonography and in finding vulnerable
atherosclerotic plaques susceptible to rupture which can cause stroke.
Abstract: The paper deals with the diagnostics of steel roof
structure of the winter sports halls built in 1970 year. The necessity
of the diagnostics has been given by the requirement to the evaluation
design of this structure, which has been caused by the new situation
in the field of the loadings given by the validity of the European
Standards in the Czech Republic from 2010 year. Due to these
changes in the normative rules, in practice existing structures are
gradually subjected to the evaluation design and depending on its
results to the strengthening or reconstruction, respectively. Steel roof
is composed of plane truss main girders, purlins and bracings and the
roof structure is supported by two arch main girders with the span of
L = 84 m. The in situ diagnostics of the roof structure was oriented to
the following parts: (i) determination and evaluation of the actual
material properties of used steel and (ii) verification of the actual
dimensions of the structural members. For the solution the nondestructive
methods have been used for in situ measurement. For the
indicative determination of steel strengths the modified method based
on the determination of Rockwell’s hardness has been used. For the
verification of the member’s dimensions (thickness of hollow
sections) the ultrasound method has been used. This paper presents
the results obtained using these testing methods and their evaluation,
from the viewpoint of the usage for the subsequent static assessment
and design evaluation of the existing structure. For the comparison,
the examples of the similar evaluations realized for steel structures of
the stadiums in Olomouc and Jihlava cities are briefly illustrated, too.
Abstract: In this study, composites were fabricated from oil
palm empty fruit bunch fiber and poly(lactic) acid by extrusion
followed by injection moulding. Surface of the fiber was pre-treated
by ultrasound in an alkali medium and treatment efficiency was
investigated by scanning electron microscopy (SEM) analysis and
Fourier transforms infrared spectrometer (FTIR). Effect of fiber
treatment on composite was characterized by tensile strength (TS),
tensile modulus (TM) and impact strength (IS). Furthermore,
biostrong impact modifier was incorporated into the treated fiber
composite to improve its impact properties. Mechanical testing
showed an improvement of up to 23.5% and 33.6% respectively for
TS and TM of treated fiber composite above untreated fiber
composite. On the other hand incorporation of impact modifier led to
enhancement of about 20% above the initial IS of the treated fiber
composite.
Abstract: Risperidone (RISP) is an antipsychotic agent and has
low water solubility and nontargeted delivery results in numerous
side effects. Hence, an attempt was made to develop SLNs hydrogel
for intranasal delivery of RISP to achieve maximum bioavailability
and reduction of side effects. RISP loaded SLNs composed of 1.65%
(w/v) lipid mass were produced by high shear homogenization (HSH)
coupled ultrasound (US) method using glycerylmonostearate (GMS)
or Imwitor 900K (solid lipid). The particles were loaded with 0.2%
(w/v) of the RISP & surface-tailored with a 2.02% (w/v) non-ionic
surfactant Tween® 80. Optimization was done using 32 factorial
design using Design Expert® software. The prepared SLNs
dispersion incorporated into Polycarbophil AA1 hydrogel (0.5%
w/v). The final gel formulation was evaluated for entrapment
efficiency, particle size, rheological properties, X ray diffraction, in
vitro diffusion, ex vivo permeation using sheep nasal mucosa and
histopathological studies for nasocilliary toxicity. The entrapment
efficiency of optimized SLNs was found to be 76 ± 2%,
polydispersity index
Abstract: The thyroid gland is the largest classic endocrine
organ that effects many organs of the body and plays a significant
role in the process of Metabolism in animals. The aim of this study
was to investigate the prevalence of thyroid disorders diagnosed by
ultrasound and microscopic Lesions of the thyroid during the
slaughter of apparently healthy One Humped Camels (Camelus
dromedarius) in Iran. Randomly, 520 male camels (With an age
range of 4 to 8 years), were studied in 2012 to 2013. The Camels’
thyroid glands were evaluated by sonographic examination. In both
longitudinal and transverse view and then tissue sections were
provide and stained with H & E and finally examined by light
microscopy. The results obtained indicated the following:
hyperplastic goiter (21%), degenerative changes (12%), follicular
cysts (8%), follicular atrophy (4%), nodular hyperplasia (3%),
adenoma (1%), carcinoma (1%) and simple goiter colloid (1%).
Ultrasound evaluation of thyroid gland in adenoma and carcinoma
showed enlargement and irregular of the gland, decreased
echogenicity, and the heterogeneous thyroid parenchyma. Also, in
follicular cysts were observed in the enlarged gland with no echo
structures of different sizes and decreased echogenicity as a local or
general. In nodular hyperplasia, increase echogenicity and
heterogeneous parenchymal were seen. These findings suggest the
use of sonography and pathology as a screening test in the diagnosis
of complications of thyroid disorders.
Abstract: Periventricular Leukomalacia (PVL) is a White Matter
Injury (WMI) of preterm neonatal brain. Objectives of the study were
to assess the neuro-developmental outcome at one year of age and to
determine a good protocol of cranial ultrasonography to detect PVL.
Two hundred and sixty four preterm neonates were included in the
study. Series of cranial ultrasound scans were done by using a
dedicated neonatal head probe 4-10 MHz of Logic e portable
ultrasound scanner. Clinical history of seizures, abnormal head
growth (hydrocephalus or microcephaly) and developmental
milestones were assessed and neurological examinations were done
until one year of age. Among live neonates, 57% who had cystic PVL
(Grades 2 and 3) manifested as cerebral palsy. In conclusion cystic
PVL has permanent neurological disabilities like cerebral palsy.
Good protocol of real time cranial ultrasonography to detect PVL is
to perform scans at least once a week until one month and at term (40
weeks of gestation).
Abstract: Cavitation in cryogenic liquids is widely present in
contemporary science. In the current study, we re-examine a
previously validated acoustic cavitation model which was developed
for a gas bubble in liquid water. Furthermore, simulations of
cryogenic fluids including the thermal effect, the effect of acoustic
pressure amplitude and the frequency of sound field on the bubble
dynamics are presented. A gas bubble (Helium) in liquids Nitrogen,
Oxygen and Hydrogen in an acoustic field at ambient pressure and
low temperature is investigated numerically. The results reveal that
the oscillation of the bubble in liquid Hydrogen fluctuates more than
in liquids Oxygen and Nitrogen. The oscillation of the bubble in
liquids Oxygen and Nitrogen is approximately similar.
Abstract: The phased-array ultrasound transducer types are
utilities for medical ultrasonography as well as optical imaging.
However, their discontinuity characteristic limits the applications due
to the artifacts contaminated into the reconstructed images. Because
of the effects of the ultrasound pressure field pattern to the echo
ultrasonic waves as well as the optical modulated signal, the side
lobes of the focused ultrasound beam induced by discontinuity of the
phased-array ultrasound transducer might the reason of the artifacts.
In this paper, a simple method in approach of numerical simulation
was used to investigate the limitation of discontinuity of the elements
in phased-array ultrasound transducer and their effects to the
ultrasound pressure field. Take into account the change of ultrasound
pressure field patterns in the conditions of variation of the pitches
between elements of the phased-array ultrasound transducer, the
appropriated parameters for phased-array ultrasound transducer
design were asserted quantitatively.
Abstract: Medical imaging technology has experienced a
dramatic change in the last few years. Medical imaging refers to the
techniques and processes used to create images of the human body
(or parts thereof) for various clinical purposes such as medical
procedures and diagnosis or medical science including the study of
normal anatomy and function. With the growth of computers and
image technology, medical imaging has greatly influenced the
medical field. The diagnosis of a health problem is now highly
dependent on the quality and the credibility of the image analysis.
This paper deals with the various aspects and types of medical
imaging.
Abstract: The aim of this work is to present a theoretical analysis of a 2D ultrasound transducer comprised of crossed arrays of metal strips placed on both sides of thin piezoelectric layer (a). Such a structure is capable of electronic beam-steering of generated wavebeam both in elevation and azimuth. In this paper a semi-analytical model of the considered transducer is developed. It is based on generalization of the well-known BIS-expansion method. Specifically, applying the electrostatic approximation, the electric field components on the surface of the layer are expanded into fast converging series of double periodic spatial harmonics with corresponding amplitudes represented by the properly chosen Legendre polynomials. The problem is reduced to numerical solving of certain system of linear equations for unknown expansion coefficients.
Abstract: Photoacoustic imaging (PAI) is a non-invasive and
non-ionizing imaging modality that combines the absorption contrast
of light with ultrasound resolution. Laser is used to deposit optical
energy into a target (i.e., optical fluence). Consequently, the target
temperature rises, and then thermal expansion occurs that leads to
generating a PA signal. In general, most image reconstruction
algorithms for PAI assume uniform fluence within an imaging object.
However, it is known that optical fluence distribution within the
object is non-uniform. This could affect the reconstruction of PA
images. In this study, we have investigated the influence of optical
fluence distribution on PA back-propagation imaging using finite
element method. The uniform fluence was simulated as a triangular
waveform within the object of interest. The non-uniform fluence
distribution was estimated by solving light propagation within a
tissue model via Monte Carlo method. The results show that the PA
signal in the case of non-uniform fluence is wider than the uniform
case by 23%. The frequency spectrum of the PA signal due to the
non-uniform fluence has missed some high frequency components in
comparison to the uniform case. Consequently, the reconstructed
image with the non-uniform fluence exhibits a strong smoothing
effect.
Abstract: The centre of rotation of the hip joint is needed for an
accurate simulation of the joint performance in many applications
such as pre-operative planning simulation, human gait analysis, and
hip joint disorders. In human movement analysis, the hip joint center
can be estimated using a functional method based on the relative
motion of the femur to pelvis measured using reflective markers
attached to the skin surface. The principal source of errors in
estimation of hip joint centre location using functional methods is
soft tissue artefacts due to the relative motion between the markers
and bone. One of the main objectives in human movement analysis is
the assessment of soft tissue artefact as the accuracy of functional
methods depends upon it. Various studies have described the
movement of soft tissue artefact invasively, such as intra-cortical
pins, external fixators, percutaneous skeletal trackers, and Roentgen
photogrammetry. The goal of this study is to present a non-invasive
method to assess the displacements of the markers relative to the
underlying bone using optical motion capture data and tissue
thickness from ultrasound measurements during flexion, extension,
and abduction (all with knee extended) of the hip joint. Results show
that the artefact skin marker displacements are non-linear and larger
in areas closer to the hip joint. Also marker displacements are
dependent on the movement type and relatively larger in abduction
movement. The quantification of soft tissue artefacts can be used as a
basis for a correction procedure for hip joint kinematics.
Abstract: Implementing significant advantages in the supply of self-compacting concrete (SCC) is necessary because of the, negative features of SCC. Examples of these features are the ductility problem along with the very high cost of its constituted materials. Silica fume with steel fiber can fix this matter by improving the ductility and decreasing the total cost of SCC by varying the cement ingredients. Many different researchers have found that there have not been enough research carried out on the steel fiber-reinforced self-compacting concrete (SFRSCC) produced with silica fume. This paper inspects both the fresh and the mechanical properties of SFRSCC with silica fume, the fresh qualities where slump flow, slump T50 and V- funnel. While, the mechanical characteristics were the compressive strength, ultrasound pulse velocity (UPV) and elastic modulus of the concrete samples. The experimental results have proven that steel fiber can enhance the mechanical features. In addition, the silica fume within the entire hybrid mix may possibly adapt the fiber dispersion and strengthen deficits due to the fibers. It could also improve the strength plus the bond between the fiber and the matrix with a dense calcium silicate-hydrate gel in SFRSCC. The concluded result was predicted using linear mathematical models and was found to be in great agreement with the experimental results.