Abstract: Metal thin-walled members have been widely used in
building industry. Usually they are utilized as purlins, girts or ceiling
beams. Due to slenderness of thin-walled cross-sections these
structural members are prone to stability problems (e.g. flexural
buckling, lateral torsional buckling). If buckling is not
constructionally prevented their resistance is limited by buckling
strength. In practice planar members of roof or wall cladding can be
attached to thin-walled members. These elements reduce
displacement of thin-walled members and therefore increase their
buckling strength. If this effect is taken into static assessment more
economical sections of thin-walled members might be utilized and
certain savings of material might be achieved. This paper focuses on
problem of determination of critical load of steel thin-walled beams
with lateral continuous restraint which is crucial for lateral torsional
buckling assessment.
Abstract: The paper deals with the diagnostics of steel roof
structure of the winter sports halls built in 1970 year. The necessity
of the diagnostics has been given by the requirement to the evaluation
design of this structure, which has been caused by the new situation
in the field of the loadings given by the validity of the European
Standards in the Czech Republic from 2010 year. Due to these
changes in the normative rules, in practice existing structures are
gradually subjected to the evaluation design and depending on its
results to the strengthening or reconstruction, respectively. Steel roof
is composed of plane truss main girders, purlins and bracings and the
roof structure is supported by two arch main girders with the span of
L = 84 m. The in situ diagnostics of the roof structure was oriented to
the following parts: (i) determination and evaluation of the actual
material properties of used steel and (ii) verification of the actual
dimensions of the structural members. For the solution the nondestructive
methods have been used for in situ measurement. For the
indicative determination of steel strengths the modified method based
on the determination of Rockwell’s hardness has been used. For the
verification of the member’s dimensions (thickness of hollow
sections) the ultrasound method has been used. This paper presents
the results obtained using these testing methods and their evaluation,
from the viewpoint of the usage for the subsequent static assessment
and design evaluation of the existing structure. For the comparison,
the examples of the similar evaluations realized for steel structures of
the stadiums in Olomouc and Jihlava cities are briefly illustrated, too.
Abstract: Steel thin-walled beams have been widely used in civil engineering as purlins, ceiling beams or wall substructure beams. There are often planar members such as trapezoidal sheeting or sandwich panels used as roof or wall cladding fastened to the steel beams. The planar members also serve as stabilization of thin-walled beams against buckling due to loss of stability. This paper focuses on problem of stabilization of steel monosymmetric thin-walled beams by trapezoidal sheeting. Some factors having influence on overall behavior of this structural system are investigated using numerical analysis. Thin-walled beams in bending stabilized by trapezoidal sheeting are of primarily interest of this study.