Abstract: Bond graph models of an electrical transformer
including the nonlinear saturation are presented. These models
determine the relation between self and mutual inductances, and
the leakage and magnetizing inductances of power transformers
with two and three windings using the properties of a bond
graph. The modelling and analysis using this methodology to
three phase power transformers or transformers with internal
incipient faults can be extended.
Abstract: A new approach for protection of power transformer is
presented using a time-frequency transform known as Wavelet transform.
Different operating conditions such as inrush, Normal, load,
External fault and internal fault current are sampled and processed
to obtain wavelet coefficients. Different Operating conditions provide
variation in wavelet coefficients. Features like energy and Standard
deviation are calculated using Parsevals theorem. These features
are used as inputs to PNN (Probabilistic neural network) for fault
classification. The proposed algorithm provides more accurate results
even in the presence of noise inputs and accurately identifies inrush
and fault currents. Overall classification accuracy of the proposed
method is found to be 96.45%. Simulation of the fault (with and
without noise) was done using MATLAB AND SIMULINK software
taking 2 cycles of data window (40 m sec) containing 800 samples.
The algorithm was evaluated by using 10 % Gaussian white noise.
Abstract: Under the limitation of investment budget, a utility
company is required to maximize the utilization of their existing
assets during their life cycle satisfying both engineering and financial
requirements. However, utility does not have knowledge about the
status of each asset in the portfolio neither in terms of technical nor
financial values. This paper presents a knowledge based model for
the utility companies in order to make an optimal decision on power
transformer with their utilization. CommonKADS methodology, a
structured development for knowledge and expertise representation,
is utilized for designing and developing knowledge based model. A
case study of One MVA power transformer of Nepal Electricity
Authority is presented. The results show that the reusable knowledge
can be categorized, modeled and utilized within the utility company
using the proposed methodologies. Moreover, the results depict that
utility company can achieve both engineering and financial benefits
from its utilization.
Abstract: The present paper deals with the analysis and development of noise-reduction transformer that has a filter function for conductive noise transmission. Two types of prototype noise-reduction transformers with two different output voltages are proposed. To determine an optimum design for the noise-reduction transformer, noise attenuation characteristics are discussed based on the experiments and the equivalent circuit analysis. The analysis gives a relation between the circuit parameters and the noise attenuation. High performance step-down noise-reduction transformer for direct power supply to electronics equipment is developed. The input voltage of the transformer is 100 V and the output voltage is 5 V. Frequency characteristics of noise attenuation are discussed, and prevention of pulse noise transmission is demonstrated. Normal mode noise attenuation of this transformer is –80 dB, and common mode exceeds –90 dB. The step-down noise-reduction transformer eliminates pulse noise efficiently.
Abstract: Based on the component approach, three kinds of
dynamic load models, including a single –motor model, a two-motor
model and composite load model have been developed for the
stability studies of Khuzestan power system. The study results are
presented in this paper. Voltage instability is a dynamic phenomenon
and therefore requires dynamic representation of the power system
components. Industrial loads contain a large fraction of induction
machines. Several models of different complexity are available for
the description investigations. This study evaluates the dynamic
performances of several dynamic load models in combination with
the dynamics of a load changing transformer. Case study is steel
industrial substation in Khuzestan power systems.
Abstract: This paper present an efficient and reliable technique of optimization which combined fuel cost economic optimization and emission dispatch using the Sigmoid Decreasing Inertia Weight Particle Swarm Optimization algorithm (PSO) to reduce the cost of fuel and pollutants resulting from fuel combustion by keeping the output of generators, bus voltages, shunt capacitors and transformer tap settings within the security boundary. The performance of the proposed algorithm has been demonstrated on IEEE 30-bus system with six generating units. The results clearly show that the proposed algorithm gives better and faster speed convergence then linearly decreasing inertia weight.
Abstract: A methodology to design a nonlinear observer in a
bond graph approach is proposed. The class of nonlinear observer
with multivariable nonlinearities is considered. A junction structure
of the bond graph observer is proposed. The proposed methodology
to an electrical transformer and a DC motor including the nonlinear
saturation is applied. Nonlinear observers for the transformer and DC
motor based on multivariable circle criterion in the physical domain
are proposed. In order to show the saturation effects on the
transformer and DC motor, simulation results are obtained. Finally,
the paper describes that convergence of the estimates to the true
states is achieved.
Abstract: Design of Converter transformer insulation is a major
challenge. The insulation of these transformers is stressed by both
AC and DC voltages. Particle contamination is one of the major
problems in insulation structures, as they generate partial discharges
leading it to major failure of insulation. Similarly corona discharges
occur in transformer insulation. This partial discharge due to particle
movement / corona formation in insulation structure under different
voltage wave shapes, are different. In the present study, UHF
technique is adopted to understand the discharge activity and could
be realized that the characteristics of UHF signal generated under
low and high fields are different. In the case of corona generated
signal, the frequency content of the UHF sensor output lies in the
range 0.3-1.2 GHz and is not much varied except for its increase in
magnitude of discharge with the increase in applied voltage. It is
realized that the current signal injected due to partial
discharges/corona is about 4ns duration measured for first one half
cycle. Wavelet technique is adopted in the present study. It allows
one to identify the frequency content present in the signal at different
instant of time. The STD-MRA analysis helps one to identify the
frequency band in which the energy content of the UHF signal is
maximum.
Abstract: This paper proposes a set of quasi-static mathematical
model of magnetic fields caused by high voltage conductors of
distribution transformer by using a set of second-order partial
differential equation. The modification for complex magnetic field
analysis and time-harmonic simulation are also utilized. In this
research, transformers were study in both balanced and unbalanced
loading conditions. Computer-based simulation utilizing the threedimensional
finite element method (3-D FEM) is exploited as a tool
for visualizing magnetic fields distribution volume a distribution
transformer. Finite Element Method (FEM) is one among popular
numerical methods that is able to handle problem complexity in
various forms. At present, the FEM has been widely applied in most
engineering fields. Even for problems of magnetic field distribution,
the FEM is able to estimate solutions of Maxwell-s equations
governing the power transmission systems. The computer simulation
based on the use of the FEM has been developed in MATLAB
programming environment.
Abstract: Model Predictive Control (MPC) is increasingly being
proposed for real time applications and embedded systems. However
comparing to PID controller, the implementation of the MPC in
miniaturized devices like Field Programmable Gate Arrays (FPGA)
and microcontrollers has historically been very small scale due to its
complexity in implementation and its computation time requirement.
At the same time, such embedded technologies have become an
enabler for future manufacturing enterprises as well as a transformer
of organizations and markets. Recently, advances in microelectronics
and software allow such technique to be implemented in embedded
systems. In this work, we take advantage of these recent advances
in this area in the deployment of one of the most studied and
applied control technique in the industrial engineering. In fact in
this paper, we propose an efficient framework for implementation
of Generalized Predictive Control (GPC) in the performed STM32
microcontroller. The STM32 keil starter kit based on a JTAG interface
and the STM32 board was used to implement the proposed GPC
firmware. Besides the GPC, the PID anti windup algorithm was
also implemented using Keil development tools designed for ARM
processor-based microcontroller devices and working with C/Cµ
langage. A performances comparison study was done between both
firmwares. This performances study show good execution speed and
low computational burden. These results encourage to develop simple
predictive algorithms to be programmed in industrial standard hardware.
The main features of the proposed framework are illustrated
through two examples and compared with the anti windup PID
controller.
Abstract: The application of a simple microcontroller to deal
with a three variable input and a single output fuzzy logic controller,
with Proportional – Integral – Derivative (PID) response control
built-in has been tested for an automatic voltage regulator. The
fuzzifiers are based on fixed range of the variables of output voltage.
The control output is used to control the wiper motor of the auto
transformer to adjust the voltage, using fuzzy logic principles, so that
the voltage is stabilized. In this report, the author will demonstrate
how fuzzy logic might provide elegant and efficient solutions in the
design of multivariable control based on experimental results rather
than on mathematical models.
Abstract: The condition of lightning surge causes the traveling waves and the temporary increase in voltage in the transmission line system. Lightning is the most harmful for destroying the transmission line and setting devices so it is necessary to study and analyze the temporary increase in voltage for designing and setting the surge arrester. This analysis describes the figure of the lightning wave in transmission line with 115 kV voltage level in Thailand by using ATP/EMTP program to create the model of the transmission line and lightning surge. Because of the limit of this program, it must be calculated for the geometry of the transmission line and surge parameter and calculation in the manual book for the closest value of the parameter. On the other hand, for the effects on surge protector when the lightning comes, the surge arrester model must be right and standardized as metropolitan electrical authority's standard. The candidate compared the real information to the result from calculation, also. The results of the analysis show that the temporary increase in voltage value will be rise to 326.59 kV at the line which is done by lightning when the surge arrester is not set in the system. On the other hand, the temporary increase in voltage value will be 182.83 kV at the line which is done by lightning when the surge arrester is set in the system and the period of the traveling wave is reduced, also. The distance for setting the surge arrester must be as near to the transformer as possible. Moreover, it is necessary to know the right distance for setting the surge arrester and the size of the surge arrester for preventing the temporary increase in voltage, effectively.
Abstract: One way for optimum loading of overdimensioning
conveyers is speed (capacity) decrement, with attention for
production capabilities and demands. At conveyers which drives with
three phase slip-ring induction motor, technically reasonable solution
for conveyer (driving motors) speed regulation is using constant
torque subsynchronous cascade with static semiconductor converter
and transformer for energy reversion to the power network. In the
paper is described mathematical model for parameter calculation of
two-motors 6 kV subsynchronous cascade. It is also demonstrated
that applying of this cascade gave several good properties, foremost
in electrical energy saving, also in improving of other energy
indexes, and finally that results in cost reduction of complete
electrical motor drive.
Abstract: The hydrogen peroxide treatment was able to
remediate chlorophenols, polycyclic aromatic hydrocarbons, diesel
and transformer oil contaminated soil. Chemical treatment of
contaminants adsorbed in peat resulted in lower contaminants-
removal and required higher addition of chemicals than the treatment
of contaminants in sand. The hydrogen peroxide treatment was found
to be feasible for soil remediation at natural soil pH. Contaminants in
soil could degrade with the addition of hydrogen peroxide only
indicating the ability of transition metals ions and minerals of these
metals presented in soil to catalyse the reaction of hydrogen peroxide
decomposition.
Abstract: Electrical distribution systems are incurring large losses as the loads are wide spread, inadequate reactive power compensation facilities and their improper control. A comprehensive static VAR compensator consisting of capacitor bank in five binary sequential steps in conjunction with a thyristor controlled reactor of smallest step size is employed in the investigative work. The work deals with the performance evaluation through analytical studies and practical implementation on an existing system. A fast acting error adaptive controller is developed suitable both for contactor and thyristor switched capacitors. The switching operations achieved are transient free, practically no need to provide inrush current limiting reactors, TCR size minimum providing small percentages of nontriplen harmonics, facilitates stepless variation of reactive power depending on load requirement so as maintain power factor near unity always. It is elegant, closed loop microcontroller system having the features of self regulation in adaptive mode for automatic adjustment. It is successfully tested on a distribution transformer of three phase 50 Hz, Dy11, 11KV/440V, 125 KVA capacity and the functional feasibility and technical soundness are established. The controller developed is new, adaptable to both LT & HT systems and practically established to be giving reliable performance.
Abstract: This paper proposes an active soft-switching circuit for
bridge converters aiming to improve the power conversion efficiency.
The proposed circuit achieves loss-less switching for both main and
auxiliary switches without increasing the main switch current/voltage
rating. A winding coupled to the primary of power transformer
ensures ZCS for the auxiliary switches during their turn-off. A 350 W,
100 kHz phase shifted full bridge (PSFB) converter is built to validate
the analysis and design. Theoretical loss calculations for proposed
circuit is presented. The proposed circuit is compared with passive
soft switched PSFB in terms of efficiency and loss in duty cycle.
Abstract: The deficit of power for electricity demand reaches
almost 30% for consumers in the last few years. This reflects with
continually increasing the price of electricity, and today the price for
small industry is almost 110Euro/MWh. The high price is additional
problem for the owners in the economy crisis which is reflected with
higher price of the goods.
The paper gives analyses of the energy needs for real agro
complex in Macedonia, private vinery with capacity of over 2 million
liters in a year and with self grapes and fruits fields. The existing
power supply is from grid with 10/04 kV transformer. The
geographical and meteorological condition of the vinery location
gives opportunity for including renewable as a power supply option
for the vinery complex.
After observation of the monthly energy needs for the vinery, the
base scenario is the existing power supply from the distribution grid.
The electricity bill in small industry has three factors: electricity in
high and low tariffs in kWh and the power engaged for the
technological process of production in kW. These three factors make
the total electricity bill and it is over 110 Euro/MWh which is the
price near competitive for renewable option. On the other side
investments in renewable (especially photovoltaic (PV)) has tendency
of decreasing with price of near 1,5 Euro/W. This means that
renewable with PV can be real option for power supply for small
industry capacities (under 500kW installed power).
Therefore, the other scenarios give the option with PV and the last
one includes wind option. The paper presents some scenarios for
power supply of the vinery as the followings:
• Base scenario of existing conventional power supply from the
grid
• Scenario with implementation of renewable of Photovoltaic
• Scenario with implementation of renewable of Photovoltaic and
Wind power
The total power installed in a vinery is near 570 kW, but the
maximum needs are around 250kW. At the end of the full paper some
of the results from scenarios will be presented. The paper also
includes the environmental impacts of the renewable scenarios, as
well as financial needs for investments and revenues from renewable.
Abstract: At present, the tendency to implement the conditionbased
maintenance (CBM), which allows the optimization of the
expenses for equipment monitoring, is more and more evident; also,
the transformer substations with remote monitoring are increasingly
used. This paper reviews all the advantages of the on-line monitoring
and presents an equipment for on-line monitoring of bushings, which
is the own contribution of specialists who are the authors of this
paper. The paper presents a study of the temperature field, using the
finite element method. For carrying out this study, the 3D modelling
of the above mentioned bushing was performed. The analysis study is
done taking into account the extreme thermal stresses, focusing at the
level of the first cooling wing section of the ceramic insulator. This
fact enables to justify the tanδ variation in time, depending on the
transformer loading and the environmental conditions. With a view
to reducing the variation of dielectric losses in bushing insulation, the
use of ferrofuids instead of mineral oils is proposed.
Abstract: The behavior of three phase five leg transformer under voltage sag is studied in this paper. This paper proposes a simple, practical model of a three phase-five leg, saturated transformer with accurate performance. Transformer saturation is produced when the voltage sag is recovered and it causes inrush current in transformer. Effects of voltage sag depth, duration and initial point on wave have been analyzed in this paper. Initial point on wave can produce maximum inrush current in five leg transformers while comparing with three leg transformers. The magnetic circuit symmetry of five leg transformer produces the more symmetrical shape of inrush current curves versus initial point on wave and sag duration than three leg transformer. The simulations show that current peak has a periodical dependence on sag duration and linear dependence on sag depth. Inrush current that is produced in three phase five leg transformer is higher than three phase three leg transformer.
Abstract: Power transformer consists of components which are
under consistent thermal and electrical stresses. The major
component which degrades under these stresses is the paper
insulation of the power transformer. At site, lightning impulses and
cable faults may cause the winding deformation. In addition, the
winding may deform due to impact during transportation. A
deformed winding will excite more stress to its insulating paper thus
will degrade it. Insulation degradation will shorten the life-span of
the transformer. Currently there are two methods of detecting the
winding deformation which are Sweep Frequency Response
Analysis (SFRA) and Low Voltage Impulse Test (LVI). The latter
injects current pulses to the winding and capture the admittance
plot. In this paper, a transformer which experienced overheating and
arcing was identified, and both SFRA and LVI were performed.
Next, the transformer was brought to the factory for untanking. The
untanking results revealed that the LVI is more accurate than the
SFRA method for this case study.