Analysis and Performance Evaluation of Noise-Reduction Transformer

The present paper deals with the analysis and development of noise-reduction transformer that has a filter function for conductive noise transmission. Two types of prototype noise-reduction transformers with two different output voltages are proposed. To determine an optimum design for the noise-reduction transformer, noise attenuation characteristics are discussed based on the experiments and the equivalent circuit analysis. The analysis gives a relation between the circuit parameters and the noise attenuation. High performance step-down noise-reduction transformer for direct power supply to electronics equipment is developed. The input voltage of the transformer is 100 V and the output voltage is 5 V. Frequency characteristics of noise attenuation are discussed, and prevention of pulse noise transmission is demonstrated. Normal mode noise attenuation of this transformer is –80 dB, and common mode exceeds –90 dB. The step-down noise-reduction transformer eliminates pulse noise efficiently.





References:
[1] C. R. Paul, Introduction to Electromagnetic Compatibility, John Wiley & Sons, New York, 1992.
[2] C. R. Paul, Introduction to Electromagnetic Compatibility, 2nd ed., John Wiley & Sons, New York, 2006.
[3] K. R. Fowler, EMC and EMI, John Wiley & Sons, New York, 2006.
[4] C. R. Paul and K. B. Hardin, "Diagnosis and reduction of conducted noise
emissions," IEEE Trans Electromagn. Compat., vol. 30, pp. 553-560, 1988.
[5] H. W. Otto, Electromagnetic Compatibility Engineering, John Wiley &
Sons, New York, 2009.
[6] S. D. Wanless, "The Paraformer," IEEE WESCON Tech. Papers., vol. 12,
Part 2, 1968.
[7] W. Z. Fam and R. P. Verma, "Theory and performance of parametric
transformers," IEEE Trans. Power App. Syst., vol. PAS-91, pp. 2494-2504, 1972.
[8] A. Sato, S. Yamada and K. Bessho, "Theory and analysis of the constant voltage regulator with bridge-connected reactor circuit," IEEE Trans. Magn., vol. MAG-12, pp. 839-841, 1976.
[9] A. Yagasaki, Proc. 1994 Int. Symp. on Electromagn. Compat., p. 791,
1994.
[10] A. Yagasaki, "Highly improved performance of a noise isolation
transformer by a thin-film short-circuit ring," IEEE Trans. Electromagn.
Compat., vol. 41, pp. 246-250, 1999.
[11] A. Yagasaki, "Characteristics of a special-isolation transformer capable of
protecting from high-voltage surges and its performance," IEEE Trans.
Electromagn. Compat., vol. 43, pp. 340-347, 2001.
[12] M. Sugisaki and H. Saotome, "Some trials for improving the performance
of noise cutout transformer," The Paper of Technical Meeting on
Magnetics, IEE Japan, MAG-03-118, 2003.