Abstract: Geological and tectonic framework indicates that
Bangladesh is one of the most seismically active regions in the world.
The Bengal Basin is at the junction of three major interacting plates:
the Indian, Eurasian, and Burma Plates. Besides there are many
active faults within the region, e.g. the large Dauki fault in the north.
The country has experienced a number of destructive earthquakes due
to the movement of these active faults. Current seismic provisions of
Bangladesh are mostly based on earthquake data prior to the 1990.
Given the record of earthquakes post 1990, there is a need to revisit
the design provisions of the code. This paper compares the base shear
demand of three major cities in Bangladesh: Dhaka (the capital city),
Sylhet, and Chittagong for earthquake scenarios of magnitudes
7.0MW, 7.5MW, 8.0MW, and 8.5MW using a stochastic model. In
particular, the stochastic model allows the flexibility to input region
specific parameters such as shear wave velocity profile (that were
developed from Global Crustal Model CRUST2.0) and include the
effects of attenuation as individual components. Effects of soil
amplification were analysed using the Extended Component
Attenuation Model (ECAM). Results show that the estimated base
shear demand is higher in comparison with code provisions leading to
the suggestion of additional seismic design consideration in the study
regions.
Abstract: In this study, the time-dependent behavior of damaged
reinforced concrete shear wall structures strengthened with composite
plates having variable fibers spacing was investigated to analyze their
seismic response. In the analytical formulation, the adherent and the
adhesive layers are all modeled as shear walls, using the mixed Finite
Element Method (FEM). The anisotropic damage model is adopted to
describe the damage extent of the Reinforced Concrete shear walls.
The phenomenon of creep and shrinkage of concrete has been
determined by Eurocode 2. Large earthquakes recorded in Algeria
(El-Asnam and Boumerdes) have been tested to demonstrate the
accuracy of the proposed method. Numerical results are obtained for non-uniform distributions of
carbon fibers in epoxy matrices. The effects of damage extent and the
delay mechanism creep and shrinkage of concrete are highlighted.
Prospects are being studied.
Abstract: The understanding of geotechnical characteristics of
near-surface material and the effects of the groundwater is very
important problem in such as site studies. For showing the relations
between seismic data and groundwater, we selected about 25 km2 as
the study area. It has been presented which is a detailed work of
seismic data and groundwater depths of Gokpinar Damp area.
Seismic waves velocity (Vp and Vs) are very important parameters
showing the soil properties. The seismic records were used the
method of the multichannel analysis of surface waves near area of
Gokpinar Damp area. Sixty sites in this area have been investigated
with survey lines about 60 m in length. MASW (Multichannel
analysis of surface wave) method has been used to generate onedimensional
shear wave velocity profile at locations. These shear
wave velocities are used to estimate equivalent shear wave velocity in
the study area at every 2 and 5 m intervals up to a depth of 45 m.
Levels of equivalent shear wave velocity of soil are used the
classified of the study area. After the results of the study, it must be
considered as components of urban planning and building design of
Gokpinar Damp area, Denizli and the application and use of these
results should be required and enforced by municipal authorities.
Abstract: The purposes of hydraulic gate are to maintain the
functions of storing and draining water. It bears long-term hydraulic
pressure and earthquake force and is very important for reservoir and
waterpower plant. The high tensile strength of steel plate is used as
constructional material of hydraulic gate. The cracks and rusts,
induced by the defects of material, bad construction and seismic
excitation and under water respectively, thus, the mechanics
phenomena of gate with crack are probing into the cause of stress
concentration, induced high crack increase rate, affect the safety and
usage of hydroelectric power plant. Stress distribution analysis is a
very important and essential surveying technique to analyze
bi-material and singular point problems. The finite difference
infinitely small element method has been demonstrated, suitable for
analyzing the buckling phenomena of welding seam and steel plate
with crack. Especially, this method can easily analyze the singularity
of kink crack. Nevertheless, the construction form and deformation
shape of some gates are three-dimensional system. Therefore, the
three-dimensional Digital Image Correlation (DIC) has been
developed and applied to analyze the strain variation of steel plate with
crack at weld joint. The proposed Digital image correlation (DIC)
technique is an only non-contact method for measuring the variation of
test object. According to rapid development of digital camera, the cost
of this digital image correlation technique has been reduced.
Otherwise, this DIC method provides with the advantages of widely
practical application of indoor test and field test without the restriction
on the size of test object. Thus, the research purpose of this research is
to develop and apply this technique to monitor mechanics crack
variations of weld steel hydraulic gate and its conformation under
action of loading. The imagines can be picked from real time
monitoring process to analyze the strain change of each loading stage.
The proposed 3-Dimensional digital image correlation method,
developed in the study, is applied to analyze the post-buckling
phenomenon and buckling tendency of welded steel plate with crack.
Then, the stress intensity of 3-dimensional analysis of different
materials and enhanced materials in steel plate has been analyzed in
this paper. The test results show that this proposed three-dimensional
DIC method can precisely detect the crack variation of welded steel
plate under different loading stages. Especially, this proposed DIC
method can detect and identify the crack position and the other flaws
of the welded steel plate that the traditional test methods hardly detect
these kind phenomena. Therefore, this proposed three-dimensional
DIC method can apply to observe the mechanics phenomena of
composite materials subjected to loading and operating.
Abstract: Non-linear dynamic time history analysis is
considered as the most advanced and comprehensive analytical
method for evaluating the seismic response and performance of
multi-degree-of-freedom building structures under the influence of
earthquake ground motions. However, effective and accurate
application of the method requires the implementation of advanced
hysteretic constitutive models of the various structural components
including masonry infill panels. Sophisticated computational research
tools that incorporate realistic hysteresis models for non-linear
dynamic time-history analysis are not popular among the professional
engineers as they are not only difficult to access but also complex and
time-consuming to use. In addition, commercial computer programs
for structural analysis and design that are acceptable to practicing
engineers do not generally integrate advanced hysteretic models
which can accurately simulate the hysteresis behavior of structural
elements with a realistic representation of strength degradation,
stiffness deterioration, energy dissipation and ‘pinching’ under cyclic
load reversals in the inelastic range of behavior. In this scenario,
push-over or non-linear static analysis methods have gained
significant popularity, as they can be employed to assess the seismic
performance of building structures while avoiding the complexities
and difficulties associated with non-linear dynamic time-history
analysis. “Push-over” or non-linear static analysis offers a practical
and efficient alternative to non-linear dynamic time-history analysis
for rationally evaluating the seismic demands. The present paper is
based on the analytical investigation of the effect of distribution of
masonry infill panels over the elevation of planar masonry infilled
reinforced concrete [R/C] frames on the seismic demands using the
capacity spectrum procedures implementing nonlinear static analysis
[pushover analysis] in conjunction with the response spectrum
concept. An important objective of the present study is to numerically
evaluate the adequacy of the capacity spectrum method using
pushover analysis for performance based design of masonry infilled
R/C frames for near-field earthquake ground motions.
Abstract: The paper aims at investigating the effect of number
of story on different structural components of reinforced concrete
building due to gravity and lateral loading. For the study, three
building models having same building plan of three, six and nine
stories are analyzed and designed using software package. All the
buildings are residential and are located in Dhaka city of Bangladesh.
Lateral load including wind and earthquake loading are applied to the
building along both longitudinal and transverse direction as per
Bangladesh National Building Code (BNBC, 2006). Equivalent static
force method is followed for the applied seismic loading. The present
study investigates as well as compares mainly total steel requirement
in different structural components for those buildings. It has been
found that total longitudinal steel requirement for beams at each floor
is 48.57% for three storied building, 61.36% for six storied building
when the total percentage is taken as 100% in case of nine storied
building. For an exterior column, the steel ratio is 2.1%, 3.06%,
4.55% for three, six and nine storied building respectively for the first
three floors. In addition, it has been noted that total weight of
longitudinal reinforcement of an interior column is 14.02 % for threestoried
building and 43.12% for six storied building when the total
reinforcement is considered 100% for nine storied building for the
first three floors.
Abstract: The current study focuses on the seismic design of
offshore pipelines against active faults. After an extensive literature
review of the provisions of the seismic norms worldwide and of the
available analytical methods, the study simulates numerically
(through finite-element modeling and strain-based criteria) the
distress of offshore pipelines subjected to PGDs induced by active
normal and reverse seismic faults at the seabed. Factors, such as the
geometrical properties of the fault, the mechanical properties of the
ruptured soil formations, and the pipeline characteristics, are
examined. After some interesting conclusions regarding the seismic
vulnerability of offshore pipelines, potential cost-effective mitigation
measures are proposed taking into account constructability issues.
Abstract: This study, tries to suggest a design method based on
displacement using finite difference numerical modeling in
reinforcing soil retaining wall with steel strip. In this case, dynamic
loading characteristics such as duration, frequency, peak ground
acceleration, geometrical characteristics of reinforced soil structure
and type of the site are considered to correct the pseudo static method
and finally introduce the pseudo static coefficient as a function of
seismic performance level and peak ground acceleration. For this
purpose, the influence of dynamic loading characteristics,
reinforcement length, height of reinforced system and type of the site
are investigated on seismic behavior of reinforcing soil retaining wall
with steel strip. Numerical results illustrate that the seismic response
of this type of wall is highly dependent to cumulative absolute
velocity, maximum acceleration, and height and reinforcement length
so that the reinforcement length can be introduced as the main factor
in shape of failure. Considering the loading parameters, geometric parameters of the
wall and type of the site showed that the used method in this study
leads to efficient designs in comparison with other methods, which
are usually based on limit-equilibrium concept. The outputs show the
over-estimation of equilibrium design methods in comparison with
proposed displacement based methods here.
Abstract: This paper presents the influence of the vertical
seismic component on the non-linear dynamics analysis of three
different structures. The subject structures were analyzed and
designed according to recent codes. This paper considers three types
of buildings: 5-, 10-, and 15-story buildings. The non-linear
dynamics analysis of the structures with assuming elastic-perfectlyplastic
behavior was performed using RAM PERFORM-3D software;
the horizontal component was taken into consideration with and
without the incorporation of the corresponding vertical component.
Dynamic responses obtained for the horizontal component acting
alone were compared with those obtained from the simultaneous
application of both seismic components. The results show that the
effect of the vertical component of ground motion may increase the
axial load significantly in the interior columns and, consequently, the
stories. The plastic mechanisms would be changed. The P-Delta
effect is expected to increase. The punching base plate shear of the
columns should be considered. Moreover, the vertical component
increases the input energy when the structures exhibit inelastic
behavior and are taller.
Abstract: Environmental and functional conditions, sometimes,
necessitate the architectural plan of the building to be asymmetric,
and this result in an asymmetric structure. In such cases finding an
optimal pattern for locating the components of lateral load bearing
system, including shear walls, in the building’s plan is desired. In
case of shear wall in addition to the location the shape of the wall
cross-section is also an effective factor. Various types of shear walls
and their proper layout might come effective in better stiffness
distribution and more appropriate seismic response of the building.
Several studies have been conducted in the context of analysis and
design of shear walls; however, few studies have been performed on
making decisions for the location and form of shear walls in multistory
buildings, especially those with irregular plan. In this study, an
attempt has been made to obtain the most reliable seismic behavior of
multi-story reinforced concrete vertically chamfered buildings by
using more appropriate shear walls form and arrangement in 7-, 10-,
12-, and 15-stoy buildings. The considered forms and arrangements
include common rectangular walls and L-, T-, U- and Z-shaped plan,
located as the core or in the outer frames of the building structure.
Comparison of seismic behaviors of the buildings, including
maximum roof displacement and particularly formation of plastic
hinges and their distribution in the buildings’ structures, have been
done based on the results of a series of nonlinear time history
analyses, by using a set of selected earthquake records. Results show
that shear walls with U-shaped cross-section, placed as the building
central core, and also walls with Z-shaped cross-section, placed at the
corners give the building more reliable seismic behavior.
Abstract: The seriously damaged structures during earthquakes
show the need and importance of design of reinforced concrete
structures with high ductility. Reinforced concrete beam-column
joints have an important function in all structures. Under seismic
excitation, the beam column joint region is subjected to horizontal
and vertical shear forces whose magnitude is many times higher than
the adjacent beam and column. Strength and ductility of structures
depends mainly on proper detailing of the reinforcement in beamcolumn
joints and the old structures were found ductility deficient.
DSP materials are obtained by using high quantities of super
plasticizers and high volumes of micro silica. In the case of High
Performance Densified Small Particle Concrete (HPDSPC), since
concrete is dense even at the micro-structure level, tensile strain
would be much higher than that of the conventional SFRC, SIFCON
& SIMCON. This in turn will improve cracking behaviour, ductility
and energy absorption capacity of composites in addition to
durability. The fine fibers used in our mix are 0.3mm diameter and 10
mm which can be easily placed with high percentage. These fibers
easily transfer stresses and act as a composite concrete unit to take up
extremely high loads with high compressive strength. HPDSPC
placed in the beam column joints helps in safety of human life due to
prolonged failure.
Abstract: Hollow section for bridge columns has some
advantages. However, current seismic design codes do not provide
design regulations for hollow bridge piers. There have been many
experimental studied for hollow reinforced concrete piers in the world.
But, Study for hollow section for bridge piers in Korea has been begun
with approximately 2000s. There has been conducted experimental
study for hollow piers of flexural controlled sections by Yeungnam
University, Sung kyunkwan University, Korea Expressway
Corporation in 2009. This study concluded that flexural controlled
sections for hollow piers showed the similar behavior to solid sections.
And there have been conducted experimental study for hollow piers of
compression controlled sections by Yeungnam University, Korea
Institute of Construction Technology in 2012. This study concluded
that compression controlled sections for hollow piers showed
compression fracture of concrete in inside wall face. Samsung
Construction & Trading Corporation has been conducted study with
Yeungnam University for reduce the quantity of reinforcement details
about hollow piers. Reduce the quantity of reinforcement details are
triangular cross tie. This study concluded that triangular reinforcement
details showed the similar behavior as compared with existing
reinforcement details.
Abstract: Nowadays, energy dissipation devices are commonly
used in structures. High rate of energy absorption during earthquakes
is the benefit of using such devices, which results in damage
reduction of structural elements, specifically columns. The hysteretic
damping capacity of energy dissipation devices is the key point that it
may adversely make analysis and design process complicated. This
effect may be generally represented by Equivalent Viscous Damping
(EVD). The equivalent viscous damping might be obtained from the
expected hysteretic behavior regarding to the design or maximum
considered displacement of a structure. In this paper, the hysteretic
damping coefficient of a steel Moment Resisting Frame (MRF),
which its performance is enhanced by a Buckling Restrained Brace
(BRB) system has been evaluated. Having foresight of damping
fraction between BRB and MRF is inevitable for seismic design
procedures like Direct Displacement-Based Design (DDBD) method.
This paper presents an approach to calculate the damping fraction for
such systems by carrying out the dynamic nonlinear time history
analysis (NTHA) under harmonic loading, which is tuned to the
natural system frequency. Two MRF structures, one equipped with
BRB and the other without BRB are simultaneously studied.
Extensive analysis shows that proportion of each system damping
fraction may be calculated by its shear story portion. In this way,
contribution of each BRB in the floors and their general contribution
in the structural performance may be clearly recognized, in advance.
Abstract: This paper presents the influence of the vertical
seismic component on the non-linear dynamics analysis of three
different structures. The subject structures were analyzed and
designed according to recent codes. This paper considers three types
of buildings: 5-, 10-, and 15-story buildings. The non-linear dynamics
analysis of the structures with assuming elastic-perfectly-plastic
behavior was performed using RAM PERFORM-3D software; the
horizontal component was taken into consideration with and without
the incorporation of the corresponding vertical component. Dynamic
responses obtained for the horizontal component acting alone were
compared with those obtained from the simultaneous application of
both seismic components. The results show that the effect of the
vertical component of ground motion may increase the axial load
significantly in the interior columns and, consequently, the stories.
The plastic mechanisms would be changed. The P-Delta effect is
expected to increase. The punching base plate shear of the columns
should be considered. Moreover, the vertical component increases the
input energy when the structures exhibit inelastic behavior and are
taller.
Abstract: Passive control methods can be utilized to build
earthquake resistant structures, and also to strengthen the vulnerable
ones. In this paper, we studied the effect of this system in increasing
the ductility and energy dissipation and also modeled the behavior of
this type of eccentric bracing, and compared the hysteresis diagram
of the modeled samples with the laboratory samples. We studied
several samples of frames with vertical shear-links in order to assess
the behavior of this type of eccentric bracing. Each of these samples
was modeled in finite element software ANSYS 9.0, and was
analyzed under the static cyclic loading. It was found that vertical
shear-links have a more stable hysteresis loops. Another analysis
showed that using honeycomb beams as the horizontal beam along
with steel reinforcement has no negative effect on the hysteresis
behavior of the sample.
Abstract: In addition to the advantages of light weight, resistant
corrosion and ease of processing, aluminum is also applied to the
long-span spatial structures. However, the elastic modulus of
aluminum is lower than that of the steel. This paper combines the
high performance aluminum honeycomb panel with the aluminum
latticed shell, forming a new panel-and-rod composite shell structure.
Through comparative analysis between the static and dynamic
performance, the conclusion that the structure of composite shell is
noticeably superior to the structure combined before.
Abstract: Currently there are many use of threaded reinforcing
bars in construction fields because those do not need additional screw
processing when connecting reinforcing bar by threaded coupler. In
this study, reinforced concrete bridge piers using threaded rebar
coupler system at the plastic hinge area were tested to evaluate seismic
performance. The test results showed that threads of the threaded rebar
coupler system could be loosened while under tension-compression
cyclic loading because tolerance and rib face angle of a threaded rebar
coupler system are greater than that of a conventional ribbed rebar
coupler system. As a result, cracks were concentrated just outside of
the mechanical coupler and stiffness of reinforced concrete bridge pier
decreased. Therefore, it is recommended that connection ratio of
mechanical couplers in one section shall be below 50% in order that
cracks are not concentrated just outside of the mechanical coupler.
Also, reduced stiffness of the specimen should be considered when
using the threaded rebar coupler system.
Abstract: The Composite Shear Walls (CSW) with steel encased
profiles can be used as lateral-load resisting systems for buildings
that require considerable large lateral-load capacity. The aim of this
work is to propose the experimental work conducted on CSW having
L section folded plate (L shape steel made-up sections) as
longitudinal reinforcement in boundary regions. The study in this
paper present the experimental test conducted on CSW having L
section folded plate as longitudinal reinforcement in boundary
regions. The tested 1/3 geometric scaled CSW has aspect ratio of 3.2.
L-shape structural steel materials with 2L-19x57x7mm dimensions
were placed in shear wall boundary zones. The seismic behavior of
CSW test specimen was investigated by evaluating and interpreting
the hysteresis curves, envelope curves, rigidity and consumed energy
graphs of this tested element. In addition to this, the experimental
results, deformation and cracking patterns were evaluated, interpreted
and suggestions of the design recommendations were proposed.
Abstract: This study aims to evaluate the effective size, section
and structural characteristics of circular hollow steel (CHS) damper.
CHS damper is among steel dampers which are used widely for
seismic energy dissipation because they are easy to install, maintain
and are inexpensive. CHS damper dissipates seismic energy through
metallic deformation due to the geometrical elasticity of circular shape
and fatigue resistance around connection part. After calculating the
effective size, which is found to be height to diameter ratio of √3,
nonlinear FE analyses were carried out to evaluate the structural
characteristics and effective section (diameter-to-ratio).
Abstract: The goal of the paper is to highlight the effect of the
building design and epicentral distance on the storey lateral
displacements, for several reinforced concrete buildings (6, 9 and 12
stories). These structures are subjected to seismic accelerations from
the Boumerdes earthquake (Algeria, May 21st, Mw = 6.8). Using the
response spectrum method (modal spectral approach), the analysis is
performed in both longitudinal and transverse directions. The
building design is expressed through the fundamental period and
epicentral distance is used to represent the earthquake effect variation
on storey lateral displacements and interstory drift for the considered
buildings.