Abstract: Batch adsorption of recalcitrant melanoidin using the abundantly available coal fly ash was carried out. It had low specific surface area (SBET) of 1.7287 m2/g and pore volume of 0.002245 cm3/g while qualitative evaluation of the predominant phases in it was done by XRD analysis. Colour removal efficiency was found to be dependent on various factors studied. Maximum colour removal was achieved around pH 6, whereas increasing sorbent mass from 10g/L to 200 g/L enhanced colour reduction from 25% to 86% at 298 K. Spontaneity of the process was suggested by negative Gibbs free energy while positive values for enthalpy change showed endothermic nature of the process. Non-linear optimization of error functions resulted in Freundlich and Redlich-Peterson isotherms describing sorption equilibrium data best. The coal fly ash had maximum sorption capacity of 53 mg/g and could thus be used as a low cost adsorbent in melanoidin removal.
Abstract: The present paper was concerned primarily with the
analysis, simulation of the air flow and thermal patterns in a lecture
room. The paper is devoted to numerically investigate the influence
of location and number of ventilation and air conditioning supply and
extracts openings on air flow properties in a lecture room. The work
focuses on air flow patterns, thermal behaviour in lecture room where
large number of students. The effectiveness of an air flow system is
commonly assessed by the successful removal of sensible and latent
loads from occupants with additional of attaining air pollutant at a
prescribed level to attain the human thermal comfort conditions and
to improve the indoor air quality; this is the main target during the
present paper. The study is carried out using computational fluid
dynamics (CFD) simulation techniques as embedded in the
commercially available CFD code (FLUENT 6.2). The CFD
modelling techniques solved the continuity, momentum and energy
conservation equations in addition to standard k – ε model equations
for turbulence closure.
Throughout the investigations, numerical validation is carried out by
way of comparisons of numerical and experimental results. Good
agreement is found among both predictions.
Abstract: This paper presents a robust method to detect obstacles in stereo images using shadow removal technique and color information. Stereo vision based obstacle detection is an algorithm that aims to detect and compute obstacle depth using stereo matching and disparity map. The proposed advanced method is divided into three phases, the first phase is detecting obstacles and removing shadows, the second one is matching and the last phase is depth computing. We propose a robust method for detecting obstacles in stereo images using a shadow removal technique based on color information in HIS space, at the first phase. In this paper we use Normalized Cross Correlation (NCC) function matching with a 5 × 5 window and prepare an empty matching table τ and start growing disparity components by drawing a seed s from S which is computed using canny edge detector, and adding it to τ. In this way we achieve higher performance than the previous works [2,17]. A fast stereo matching algorithm is proposed that visits only a small fraction of disparity space in order to find a semi-dense disparity map. It works by growing from a small set of correspondence seeds. The obstacle identified in phase one which appears in the disparity map of phase two enters to the third phase of depth computing. Finally, experimental results are presented to show the effectiveness of the proposed method.
Abstract: This study aimed to present the mechanical
performance evaluation of the dynamic hip screw (DHS) for
trochanteric fracture by means of finite element method. The
analyses were performed based on stainless steel and titanium
implant material definitions at various stages of bone healing and
including implant removal. The assessment of the mechanical
performance used two parameters, von Mises stress to evaluate the
strength of bone and implant and elastic strain to evaluate fracture
stability. The results show several critical aspects of dynamic hip
screw for trochanteric fracture stabilization. In the initial stage of
bone healing process, partial weight bearing should be applied to
avoid the implant failure. In the late stage of bone healing, stainless
steel implant should be removed.
Abstract: Magnesium is used implant material potentially for
non-toxicity to the human body. Due to the excellent
bio-compatibility, Mg alloys is applied to implants avoiding removal
second surgery. However, it is found commercial magnesium alloys
including aluminum has low corrosion resistance, resulting
subcutaneous gas bubbles and consequently the approach as
permanent bio-materials. Generally, Aluminum is known to pollution
substance, and it raises toxicity to nervous system. Therefore
especially Mg-35Zn-3Ca alloy is prepared for new biodegradable
materials in this study. And the pulsed power is used in
constant-current mode of DC power kinds of anodization. Based on
the aforementioned study, it examines corrosion resistance and
biocompatibility by effect of current and frequency variation. The
surface properties and thickness were compared using scanning
electronic microscopy. Corrosion resistance was assessed via
potentiodynamic polarization and the effect of oxide layer on the body
was assessed cell viability. Anodized Mg-35Zn-3Ca alloy has good
biocompatibility in vitro by current and frequency variation.
Abstract: Microcirculation is essential for the proper supply of
oxygen and nutritive substances to the biological tissue and the
removal of waste products of metabolism. The determination of
blood flow in the capillaries is therefore of great interest to clinicians.
A comparison has been carried out using the developed non-invasive,
non-contact and whole field laser speckle contrast imaging (LSCI)
based technique and as well as a commercially available laser
Doppler blood flowmeter (LDF) to evaluate blood flow at the finger
tip and elbow and is presented here. The LSCI technique gives more
quantitative information on the velocity of blood when compared to
the perfusion values obtained using the LDF. Measurement of blood
flow in capillaries can be of great interest to clinicians in the
diagnosis of vascular diseases of the upper extremities.
Abstract: This paper demonstrates the results when either
Shiftrows stage or Mixcolumns stage and when both the stages are
omitted in the well known block cipher Advanced Encryption
Standard(AES) and its modified version AES with Key Dependent
S-box(AES-KDS), using avalanche criterion and other tests namely
encryption quality, correlation coefficient, histogram analysis and
key sensitivity tests.
Abstract: The ElectroEncephaloGram (EEG) is useful for
clinical diagnosis and biomedical research. EEG signals often
contain strong ElectroOculoGram (EOG) artifacts produced
by eye movements and eye blinks especially in EEG recorded
from frontal channels. These artifacts obscure the underlying
brain activity, making its visual or automated inspection
difficult. The goal of ocular artifact removal is to remove
ocular artifacts from the recorded EEG, leaving the underlying
background signals due to brain activity. In recent times,
Independent Component Analysis (ICA) algorithms have
demonstrated superior potential in obtaining the least
dependent source components. In this paper, the independent
components are obtained by using the JADE algorithm (best
separating algorithm) and are classified into either artifact
component or neural component. Neural Network is used for
the classification of the obtained independent components.
Neural Network requires input features that exactly represent
the true character of the input signals so that the neural
network could classify the signals based on those key
characters that differentiate between various signals. In this
work, Auto Regressive (AR) coefficients are used as the input
features for classification. Two neural network approaches
are used to learn classification rules from EEG data. First, a
Polynomial Neural Network (PNN) trained by GMDH (Group
Method of Data Handling) algorithm is used and secondly,
feed-forward neural network classifier trained by a standard
back-propagation algorithm is used for classification and the
results show that JADE-FNN performs better than JADEPNN.
Abstract: In a nuclear reactor Loss of Coolant accident (LOCA)
considers wide range of postulated damage or rupture of pipe in the
heat transport piping system. In the case of LOCA with/without
failure of emergency core cooling system in a Pressurised Heavy
water Reactor, the Pressure Tube (PT) temperature could rise
significantly due to fuel heat up and gross mismatch of the heat
generation and heat removal in the affected channel. The extent and
nature of deformation is important from reactor safety point of view.
Experimental set-ups have been designed and fabricated to simulate
ballooning (radial deformation) of PT for 220 MWe IPHWRs.
Experiments have been conducted by covering the CT by ceramic
fibers and then by submerging CT in water of voided PTs. In both
the experiments, it is observed that ballooning initiates at a
temperature around 665´┐¢C and complete contact between PT and
Caldaria Tube (CT) occurs at around 700´┐¢C approximately. The
strain rate is found to be 0.116% per second. The structural integrity
of PT is retained (no breach) for all the experiments. The PT heatup
is found to be arrested after the contact between PT and CT, thus
establishing moderator acting as an efficient heat sink for IPHWRs.
Abstract: “Garbage enzyme", a fermentation product of kitchen waste, water and brown sugar, is claimed in the media as a multipurpose solution for household and agricultural uses. This study assesses the effects of dilutions (5% to 75%) of garbage enzyme in reducing pollutants in domestic wastewater. The pH of the garbage enzyme was found to be 3.5, BOD concentration about 150 mg/L. Test results showed that the garbage enzyme raised the wastewater-s BOD in proportion to its dilution due to its high organic content. For mixtures with more than 10% garbage enzyme, its pH remained acidic after the 5-day digestion period. However, it seems that ammonia nitrogen and phosphorus could be removed by the addition of the garbage enzyme. The most economic solution for removal of ammonia nitrogen and phosphorus was found to be 9%. Further tests are required to understand the removal mechanisms of the ammonia nitrogen and phosphorus.
Abstract: The hydrogen peroxide treatment was able to
remediate chlorophenols, polycyclic aromatic hydrocarbons, diesel
and transformer oil contaminated soil. Chemical treatment of
contaminants adsorbed in peat resulted in lower contaminants-
removal and required higher addition of chemicals than the treatment
of contaminants in sand. The hydrogen peroxide treatment was found
to be feasible for soil remediation at natural soil pH. Contaminants in
soil could degrade with the addition of hydrogen peroxide only
indicating the ability of transition metals ions and minerals of these
metals presented in soil to catalyse the reaction of hydrogen peroxide
decomposition.
Abstract: This paper deals optimized model to investigate the
effects of peak current, pulse on time and pulse off time in EDM performance on material removal rate of titanium alloy utilizing copper tungsten as electrode and positive polarity of the electrode. The experiments are carried out on Ti6Al4V. Experiments were
conducted by varying the peak current, pulse on time and pulse off time. A mathematical model is developed to correlate the influences of these variables and material removal rate of workpiece. Design of
experiments (DOE) method and response surface methodology
(RSM) techniques are implemented. The validity test of the fit and adequacy of the proposed models has been carried out through
analysis of variance (ANOVA). The obtained results evidence that as
the material removal rate increases as peak current and pulse on time
increases. The effect of pulse off time on MRR changes with peak ampere. The optimum machining conditions in favor of material removal rate are verified and compared. The optimum machining
conditions in favor of material removal rate are estimated and verified with proposed optimized results. It is observed that the developed model is within the limits of the agreeable error (about
4%) when compared to experimental results. This result leads to desirable material removal rate and economical industrial machining to optimize the input parameters.
Abstract: Electrical Discharge Machine (EDM) is especially
used for the manufacturing of 3-D complex geometry and hard
material parts that are extremely difficult-to-machine by conventional
machining processes. In this paper authors review the research work
carried out in the development of die-sinking EDM within the past
decades for the improvement of machining characteristics such as
Material Removal Rate, Surface Roughness and Tool Wear Ratio. In
this review various techniques reported by EDM researchers for
improving the machining characteristics have been categorized as
process parameters optimization, multi spark technique, powder
mixed EDM, servo control system and pulse discriminating. At the
end, flexible machine controller is suggested for Die Sinking EDM to
enhance the machining characteristics and to achieve high-level
automation. Thus, die sinking EDM can be integrated with Computer
Integrated Manufacturing environment as a need of agile
manufacturing systems.
Abstract: In this paper, a Biochemical Methane Potential (BMP)
test provides a measure of the energy production potential from codigestion
between the frozen seafood wastewater and the decanter
cake. The experiments were conducted in laboratory-scale. The
suitable ratio of the frozen seafood wastewater and the decanter cake
was observed in the BMP test. The ratio of the co-digestion between
the frozen seafood wastewater and the decanter cake has impacts on
the biogas production and energy production potential. The best
performance for energy production potential using BMP test
observed from the 180 ml of the frozen seafood wastewater and 10 g
of the decanter cake ratio. This ratio provided the maximum methane
production at 0.351 l CH4/g TCODremoval. The removal efficiencies
are 76.18%, 83.55%, 43.16% and 56.76% at TCOD, SCOD, TS and
VS, respectively. The result can be concluded that the decanter cake
can improve the energy production potential of the frozen seafood
wastewater. The energy provides from co-digestion between frozen
seafood wastewater and decanter cake approximately 19x109
MJ/year in Thailand.
Abstract: This study was to investigate the performance of
hybrid solvents blended between primary, secondary, or tertiary
amines and piperazine (PZ) for CO2 removal from flue gas in terms
of CO2 absorption capacity and regeneration efficiency at 90 oC.
Alkanolamines used in this work were monoethanolamine (MEA),
diethanolamine (DEA), and triethanolamine (TEA). The CO2
absorption was experimentally examined under atmospheric pressure
and room temperature. The results show that MEA blend with PZ
provided the maximum CO2 absorption capacity of 0.50 mol
CO2/mol amine while TEA provided the minimum CO2 absorption
capacity of 0.30 mol CO2/mol amine. TEA was easier to regenerate
for both first cycle and second cycle with less loss of absorption
capacity. The regeneration efficiency of TEA was 95.09 and 92.89 %,
for the first and second generation cycles, respectively.
Abstract: One of the main research directions in CAD/CAM
machining area is the reducing of machining time.
The feedrate scheduling is one of the advanced techniques that
allows keeping constant the uncut chip area and as sequel to keep
constant the main cutting force. They are two main ways for feedrate
optimization. The first consists in the cutting force monitoring, which
presumes to use complex equipment for the force measurement and
after this, to set the feedrate regarding the cutting force variation. The
second way is to optimize the feedrate by keeping constant the
material removal rate regarding the cutting conditions.
In this paper there is proposed a new approach using an extended
database that replaces the system model.
The feedrate scheduling is determined based on the identification
of the reconfigurable machine tool, and the feed value determination
regarding the uncut chip section area, the contact length between tool
and blank and also regarding the geometrical roughness.
The first stage consists in the blank and tool monitoring for the
determination of actual profiles. The next stage is the determination
of programmed tool path that allows obtaining the piece target
profile.
The graphic representation environment models the tool and blank
regions and, after this, the tool model is positioned regarding the
blank model according to the programmed tool path. For each of
these positions the geometrical roughness value, the uncut chip area
and the contact length between tool and blank are calculated. Each of
these parameters are compared with the admissible values and
according to the result the feed value is established.
We can consider that this approach has the following advantages:
in case of complex cutting processes the prediction of cutting force is
possible; there is considered the real cutting profile which has
deviations from the theoretical profile; the blank-tool contact length
limitation is possible; it is possible to correct the programmed tool
path so that the target profile can be obtained.
Applying this method, there are obtained data sets which allow the
feedrate scheduling so that the uncut chip area is constant and, as a
result, the cutting force is constant, which allows to use more
efficiently the machine tool and to obtain the reduction of machining
time.
Abstract: Abrasive Jet Machining is an Unconventional
machining process in which the metal is removed from brittle and
hard material in the form of micro-chips. With increase in need of
materials like ceramics, composites, in manufacturing of various
Mechanical & Electronic components, AJM has become a useful
technique for micro machining. The present study highlights the
influence of different parameters like Pressure, SOD, Time, Abrasive
grain size, nozzle diameter on the Metal removal of FRP (Fiber
Reinforced Polymer) composite by Abrasive jet machining. The
results of the Experiments conducted were analyzed and optimized
with TAGUCHI method of Optimization and ANOVA for Optimal
Value.
Abstract: Research results and optimal parameters investigation
of laser cut and profiling of diamond and quartz substrates by
femtosecond laser pulses are presented. Profiles 10 μm in width, ~25
μm in depth and several millimeters long were made. Investigation of
boundaries quality has been carried out with the use of AFM
«Vecco». Possibility of technological formation of profiles and
micro-holes in diamond and quartz substrates with nanometer-scale
boundaries is shown. Experimental results of multilayer dielectric
cover treatment are also presented. Possibility of precise upper layer
(thickness of 70–140 nm) removal is demonstrated. Processes of thin
metal film (60 nm and 350 nm thick) treatment are considered.
Isolation tracks (conductance ~ 10-11 S) 1.6–2.5 μm in width in
conductive metal layers are formed.
Abstract: Wireless capsule Endoscopy (WCE) has rapidly
shown its wide applications in medical domain last ten years
thanks to its noninvasiveness for patients and support for thorough
inspection through a patient-s entire digestive system including
small intestine. However, one of the main barriers to efficient
clinical inspection procedure is that it requires large amount of
effort for clinicians to inspect huge data collected during the
examination, i.e., over 55,000 frames in video. In this paper, we
propose a method to compute meaningful motion changes of
WCE by analyzing the obtained video frames based on regional
optical flow estimations. The computed motion vectors are used to
remove duplicate video frames caused by WCE-s imaging nature,
such as repetitive forward-backward motions from peristaltic
movements. The motion vectors are derived by calculating
directional component vectors in four local regions. Our
experiments are performed on small intestine area, which is of
main interest to clinical experts when using WCEs, and our
experimental results show significant frame reductions comparing
with a simple frame-to-frame similarity-based image reduction
method.
Abstract: One of the main challenges for one phase anaerobic digestion processes is the high concentration of NH4+ and PO4 3- ions
in the digested sludge supernatant. This project focuses on enhancing the removal of nutrients during the anaerobic digestion process through fixing both NH4+ and PO4 3- ions in the form of struvite (magnesium ammonium phosphate, MAP, MgNH4PO4.6H2O) within the anaerobic sludge. Batch anaerobic digestion tests showed that Mg2+ concentration in the range 279 – 812 mg/L had insignificant effect on CGP but incurred a slight increase in COD removal. The reactor that had soluble Mg2+:NH4+:PO43- at a molar ratio of 1.28:1:00:1:00 achieved the best performance enhancement of 8% increase in COD removal and 32% reduction in NH4+ in the reactor supernatant. Overall, the results show that there is a potential to optimise conventional anaerobic digestion such that supernatant lean in P and N, and sludge rich in nutrients are obtained.