Abstract: The purpose of this research is to establish the experimental conditions for removal of Cibacron Brilliant Yellow 3G-P dye (CBY) from aqueous solutions by sorption onto coffee husks as a low-cost sorbent. The effects of various experimental parameters (e.g. initial CBY dye concentration, sorbent mass, pH, temperature) were examined and the optimal experimental conditions were determined. The results indicated that the removal of the dye was pH dependent and at initial pH of 2, the dye was removed effectively. The CBY dye sorption data were fitted to Langmuir, Freundlich, Temkin and Dubinin-Radushkevich equilibrium models. The maximum sorption capacity of CBY dye ions onto coffee husks increased from 24.04 to 35.04 mg g-1 when the temperature was increased from 293 to 313 K. The calculated sorption thermodynamic parameters including ΔG°, ΔH°, and ΔS° indicated that the CBY dye sorption onto coffee husks is a spontaneous, endothermic and mainly physical in nature.
Abstract: Losses reduction initiatives in distribution systems
have been activated due to the increasing cost of supplying
electricity, the shortage in fuel with ever-increasing cost to produce
more power, and the global warming concerns. These initiatives have
been introduced to the utilities in shape of incentives and penalties.
Recently, the electricity distribution companies in Oman have been
incentivized to reduce the distribution technical and non-technical
losses with an equal annual reduction rate for 6 years. In this paper,
different techniques for losses reduction in Mazoon Electricity
Company (MZEC) are addressed. In this company, high numbers of
substation and feeders were found to be non-compliant with the
Distribution System Security Standard (DSSS). Therefore, 33
projects have been suggested to bring non-complying 29 substations
and 28 feeders to meet the planed criteria and to comply with the
DSSS. The largest part of MZEC-s network (South Batinah region)
was modeled by ETAP software package. The model has been
extended to implement the proposed projects and to examine their
effects on losses reduction. Simulation results have shown that the
implementation of these projects leads to a significant improvement
in voltage profile, and reduction in the active and the reactive power
losses. Finally, the economical analysis has revealed that the
implementation of the proposed projects in MZEC leads to an annual
saving of about US$ 5 million.
Abstract: This paper presents an approach for daily optimal operation of distribution networks considering Distributed Generators (DGs). Due to private ownership of DGs, a cost based compensation method is used to encourage DGs in active and reactive power generation. The objective function is summation of electrical energy generated by DGs and substation bus (main bus) in the next day. A genetic algorithm is used to solve the optimal operation problem. The approach is tested on an IEEE34 buses distribution feeder.
Abstract: In this paper, investigation of subsynchronous
resonance (SSR) characteristics of a hybrid series compensated
system and the design of voltage controller for three level 24-pulse
Voltage Source Converter based Static Synchronous Series
Compensator (SSSC) is presented. Hybrid compensation consists of
series fixed capacitor and SSSC which is a active series FACTS
controller. The design of voltage controller for SSSC is based on
damping torque analysis, and Genetic Algorithm (GA) is adopted for
tuning the controller parameters. The SSR Characteristics of SSSC
with constant reactive voltage control modes has been investigated.
The results show that the constant reactive voltage control of SSSC
has the effect of reducing the electrical resonance frequency, which
detunes the SSR.The analysis of SSR with SSSC is carried out based
on frequency domain method, eigenvalue analysis and transient
simulation. While the eigenvalue and damping torque analysis are
based on D-Q model of SSSC, the transient simulation considers both
D-Q and detailed three phase nonlinear system model using
switching functions.
Abstract: This paper discusses coordinated reactive power -
voltage (Q-V) control in a multi machine steam power plant. The
drawbacks of manual Q-V control are briefly listed, and the design
requirements for coordinated Q-V controller are specified.
Theoretical background and mathematical model of the new
controller are presented next followed by validation of developed
Matlab/Simulink model through comparison with recorded
responses in real steam power plant and description of practical
realisation of the controller. Finally, the performance of
commissioned controller is illustrated on several examples of
coordinated Q-V control in real steam power plant and compared
with manual control.
Abstract: Custom power is a technology driven product and
service solution which embraces a family devices such as Dynamic
Voltage Restorer (DVR), Distributed Shunt Compensator
(DSTATCOM), Solid State Breaker (SSB) etc which will provide
power quality functions at distribution voltages. The rapid response
of these devices enables them to operate in real time, providing
continuous and dynamic control of the supply including voltage and
reactive power regulation, harmonic reduction and elimination of
voltage dips. This paper presents the benefits of multilevel inverters
when they are used for DPC based custom power devices. Power
flow control mechanism, salient features, advantages and
disadvantages of direct power control (DPC) using lookup table,
SVM, predictive voltage vector and hybrid DPC strategies are
discussed in this paper. Simulation results of three level inverter
based STATCOM, harmonic analysis of multi level inverters are
presented at the end.
Abstract: As one result of the project “Reactive Construction
Project Scheduling using Real Time Construction Logistic Data and
Simulation”, a procedure for using data about uncertain resource
availability assumptions in reactive scheduling processes has been
developed. Prediction data about resource availability is generated in
a formalized way using real-time monitoring data e.g. from auto-ID
systems on the construction site and in the supply chains. The paper
focusses on the formalization of the procedure for monitoring
construction logistic processes, for the detection of disturbance and
for generating of new and uncertain scheduling assumptions for the
reactive resource constrained simulation procedure that is and will be
further described in other papers.
Abstract: This paper proposes a three-phase four-wire currentcontrolled
Voltage Source Inverter (CC-VSI) for both power quality
improvement and PV energy extraction. For power quality
improvement, the CC-VSI works as a grid current-controlling shunt
active power filter to compensate for harmonic and reactive power of
loads. Then, the PV array is coupled to the DC bus of the CC-VSI
and supplies active power to the grid. The MPPT controller employs
the particle swarm optimization technique. The output of the MPPT
controller is a DC voltage that determines the DC-bus voltage
according to PV maximum power. The PSO method is simple and
effective especially for a partially shaded PV array. From computer
simulation results, it proves that grid currents are sinusoidal and inphase
with grid voltages, while the PV maximum active power is
delivered to loads.
Abstract: High strength concrete has been used in situations
where it may be exposed to elevated temperatures. Numerous authors
have shown the significant contribution of polypropylene fiber to the
spalling resistance of high strength concrete.
When cement-based composite that reinforced by polypropylene
fibers heated up to 170 °C, polypropylene fibers readily melt and
volatilize, creating additional porosity and small channels in to the
matrix that cause the poor structure and low strength.
This investigation develops on the mechanical properties of mortar
incorporating polypropylene fibers exposed to high temperature.
Also effects of different pozzolans on strength behaviour of samples
at elevated temperature have been studied.
To reach this purpose, the specimens were produced by partial
replacement of cement with finely ground glass, silica fume and rice
husk ash as high reactive pozzolans. The amount of this replacement
was 10% by weight of cement to find the effects of pozzolans as a
partial replacement of cement on the mechanical properties of
mortars. In this way, lots of mixtures with 0%, 0.5%, 1% and 1.5% of
polypropylene fibers were cast and tested for compressive and
flexural strength, accordance to ASTM standard. After that
specimens being heated to temperatures of 300, 600 °C, respectively,
the mechanical properties of heated samples were tested.
Mechanical tests showed significant reduction in compressive
strength which could be due to polypropylene fiber melting. Also
pozzolans improve the mechanical properties of sampels.
Abstract: This paper presents the impact study of apparent
reactance injected by series Flexible AC Transmission System
(FACTS) i.e. Thyristor Controlled Series Reactor (TCSR) on the
measured impedance of a 400 kV single electrical transmission line
in the presence of phase to earth fault with fault resistance. The study
deals with an electrical transmission line of Eastern Algerian
transmission networks at Group Sonelgaz (Algerian Company of
Electrical and Gas) compensated by TCSR connected at midpoint of
the line. This compensator used to inject active and reactive powers
is controlled by three TCSR-s. The simulations results investigate the
impacts of the TCSR on the parameters of short circuit calculation
and parameters of measured impedance by distance relay in the
presence of earth fault for three cases study.
Abstract: Equilibrium and rate based models have been applied
in the simulation of methyl tertiary-butyl ether (MTBE) synthesis
through reactive distillation. Temperature and composition profiles
were compared for both the models and found that both the profiles
trends, though qualitatively similar are significantly different
quantitatively. In the rate based method (RBM), multicomponent
mass transfer coefficients have been incorporated to describe
interphase mass transfer. MTBE mole fraction in the bottom stream is
found to be 0.9914 in the Equilibrium Model (EQM) and only 0.9904
for RBM when the same column configuration was preserved. The
individual tray efficiencies were incorporated in the EQM and
simulations were carried out. Dynamic simulation have been also
carried out for the two column configurations and compared.
Abstract: In order to investigate a PROX microreactor
performance, two-dimensional modeling of the reacting flow
between two parallel plates is performed through a finite volume
method using an improved SIMPLE algorithm. A three-step surface
kinetics including hydrogen oxidation, carbon monoxide oxidation
and water-gas shift reaction is applied for a Pt-Fe/γ-Al2O3 catalyst
and operating temperatures of about 100ºC. Flow pattern, pressure
field, temperature distribution, and mole fractions of species are
found in the whole domain for all cases. Also, the required reactive
length for removing carbon monoxide from about 2% to less than 10
ppm is found. Furthermore, effects of hydraulic diameter, wall
temperature, and inlet mole fraction of air and water are investigated
by considering carbon monoxide selectivity and conversion. It is
found that air and water addition may improve the performance of
the microreactor in carbon monoxide removal in such operating
conditions; this is in agreement with the pervious published results.
Abstract: Most electrical distribution systems are incurring large
losses as the loads are wide spread, inadequate reactive power
compensation facilities and their improper control. A typical static
VAR compensator consists of capacitor bank in binary sequential
steps operated in conjunction with a thyristor controlled reactor of the
smallest step size. This SVC facilitates stepless control of reactive
power closely matching with load requirements so as to maintain
power factor nearer to unity. This type of SVC-s requiring a
appropriately controlled TCR. This paper deals with an air cored
reactor suitable for distribution transformer of 3phase, 50Hz, Dy11,
11KV/433V, 125 KVA capacity. Air cored reactors are designed,
built, tested and operated in conjunction with capacitor bank in five
binary sequential steps. It is established how the delta connected TCR
minimizes the harmonic components and the operating range for
various electrical quantities as a function of firing angle is
investigated. In particular firing angle v/s line & phase currents, D.C.
components, THD-s, active and reactive powers, odd and even triplen
harmonics, dominant characteristic harmonics are all investigated and
range of firing angle is fixed for satisfactory operation. The harmonic
spectra for phase and line quantities at specified firing angles are
given. In case the TCR is operated within the bound specified in this
paper established through simulation studies are yielding the best
possible operating condition particularly free from all dominant
harmonics.
Abstract: Performance of a cobalt doped sol-gel derived silica (Co/SiO2) catalyst for Fischer–Tropsch synthesis (FTS) in slurryphase reactor was studied using paraffin wax as initial liquid media. The reactive mixed gas, hydrogen (H2) and carbon monoxide (CO) in a molar ratio of 2:1, was flowed at 50 ml/min. Braunauer-Emmett- Teller (BET) surface area and X-ray diffraction (XRD) techniques were employed to characterize both the specific surface area and crystallinity of the catalyst, respectively. The reduction behavior of Co/SiO2 catalyst was investigated using the Temperature Programmmed Reduction (TPR) method. Operating temperatures were varied from 493 to 533K to find the optimum conditions to maximize liquid fuels production, gasoline and diesel.