Abstract: Triangular trihedral corner reflector (CR) has been widely used as point target for synthetic aperture radar (SAR) calibration and image quality assessment. The additional “tip” of the triangular plate does not contribute to the reflector’s theoretical RCS and if it interacts with a perfectly reflecting ground plane, it will yield an increase of RCS at the radar bore-sight and decrease the accuracy of SAR calibration and image quality assessment. Regarding this problem, two types of CRs were manufactured. One was the hexagonal trihedral CR. It is a self-illuminating CR with relatively small plate edge length, while large edge length usually introduces unexpected edge diffraction error. The other was the triangular trihedral CR with extended bottom plate which considers the effect of ‘tip’ into the total RCS. In order to assess the performance of the two types of new CRs, flight campaign over the National Calibration and Validation Site for High Resolution Remote Sensors was carried out. Six hexagonal trihedral CRs and two bottom-extended trihedral CRs, as well as several traditional triangular trihedral CRs, were deployed. KOMPSAT-5 X-band SAR image was acquired for the performance analysis of the hexagonal trihedral CRs. C-band airborne SAR images were acquired for the performance analysis of the bottom-extended trihedral CRs. The analysis results showed that the impulse response function of both the hexagonal trihedral CRs and bottom-extended trihedral CRs were much closer to the ideal sinc-function than the traditional triangular trihedral CRs. The flight campaign results validated the advantages of new types of CRs and they might be useful in the future SAR calibration mission.
Abstract: The selection of diffractive events in the ALICE experiment during the first data taking period (RUN-I) of the Large Hadron Collider (LHC) was limited by the range over which rapidity gaps occur. It would be possible to achieve better measurements by expanding the range in which the production of particles can be detected. For this purpose, the ALICE Diffractive (AD0) detector has been installed and commissioned for the second phase (RUN-II). Any new detector should be able to take the data synchronously with all other detectors and be operated through the ALICE central systems. One of the key elements that must be developed for the AD0 detector is the Detector Control System (DCS). The DCS must be designed to operate safely and correctly this detector. Furthermore, the DCS must also provide optimum operating conditions for the acquisition and storage of physics data and ensure these are of the highest quality. The operation of AD0 implies the configuration of about 200 parameters, from electronics settings and power supply levels to the archiving of operating conditions data and the generation of safety alerts. It also includes the automation of procedures to get the AD0 detector ready for taking data in the appropriate conditions for the different run types in ALICE. The performance of AD0 detector depends on a certain number of parameters such as the nominal voltages for each photomultiplier tube (PMT), their threshold levels to accept or reject the incoming pulses, the definition of triggers, etc. All these parameters define the efficiency of AD0 and they have to be monitored and controlled through AD0 DCS. Finally, AD0 DCS provides the operator with multiple interfaces to execute these tasks. They are realized as operating panels and scripts running in the background. These features are implemented on a SCADA software platform as a distributed control system which integrates to the global control system of the ALICE experiment.
Abstract: We present a family of data-reusing and affine
projection algorithms. For identification of a noisy linear finite
impulse response channel, a partial knowledge of a channel,
especially noise, can be used to improve the performance of
the adaptive filter. Motivated by this fact, the proposed scheme
incorporates an estimate of a knowledge of noise. A constraint, called
the adaptive noise constraint, estimates an unknown information of
noise. By imposing this constraint on a cost function of data-reusing
and affine projection algorithms, a cost function based on the adaptive
noise constraint and Lagrange multiplier is defined. Minimizing the
new cost function leads to the adaptive noise constrained (ANC)
data-reusing and affine projection algorithms. Experimental results
comparing the proposed schemes to standard data-reusing and affine
projection algorithms clearly indicate their superior performance.
Abstract: Ultrasonic pulse velocity (UPV) method has been shown for some time to provide a reliable means of estimating properties and offers a unique opportunity for direct, quick and safe control of building damaged by earthquake, fatigue, conflagration and catastrophic scenarios. On this investigation hybrid reinforced concrete has been investigated by UPV method. Hooked end steel fiber of length 50 and 30 mm was added to concrete in different proportion 0, 0.25, 0.5, and 1 % by the volume of concrete. On the other hand, polypropylene fiber of length 12, 6, 3 mm was added to concrete of 0.1, 0.2, and 0.4 % by the volume of concrete. Fifteen different mixture has been prepared to investigate the relation between compressive strength and UPV values and also to investigate on the effect of volume and type of fiber on UPV values.
Abstract: The present work is devoted to thermographic studies of curved composite panels (unidirectional GFRP) with subsurface defects. Various artificial defects, created by inserting PTFE stripe between individual layers of a laminate during manufacturing stage are studied. The analysis is conducted both with the use finite element method and experiments. To simulate transient heat transfer in 3D model with embedded various defect sizes, the ANSYS package is used. Pulsed Thermography combined with optical excitation source provides good results for flat surfaces. Composite structures are mostly used in complex components, e.g., pipes, corners and stiffeners. Local decrease of mechanical properties in these regions can have significant influence on strength decrease of the entire structure. Application of active procedures of thermography to defect detection and evaluation in this type of elements seems to be more appropriate that other NDT techniques. Nevertheless, there are various uncertainties connected with correct interpretation of acquired data. In this paper, important factors concerning Infrared Thermography measurements of curved surfaces in the form of cylindrical panels are considered. In addition, temperature effects on the surface resulting from complex geometry and embedded and real defect are also presented.
Abstract: This paper describes the design of a pulse generator based on the Programmable System-on-Chip (PSoC) module. In this module, using programmable logic is possible to implement different pulses which are required for ultrasonic applications, either in a single channel or multiple channels. This module can operate with programmable frequencies from 3-74 MHz; its programming may be versatile covering a wide range of ultrasonic applications. It is ideal for low-power ultrasonic applications where PZT or PVDF transducers are used.
Abstract: In recent years, non-invasive Focused Ultrasound (FU) has been utilized for generating bubbles (cavities) to ablate target tissue by mechanical fractionation. Intensities >10 kW/cm2 are required to generate the inertial cavities. The generation, rapid growth, and collapse of these inertial cavities cause tissue fractionation and the process is called Histotripsy. The ability to fractionate tissue from outside the body has many clinical applications including the destruction of the tumor mass. The process of tissue fractionation leaves a void at the treated site, where all the affected tissue is liquefied to particles at sub-micron size. The liquefied tissue will eventually be absorbed by the body. Histotripsy is a promising non-invasive treatment modality. This paper presents a technique for generating inertial cavities at lower intensities (< 1 kW/cm2). The technique (patent pending) is based on amplitude modulation (AM), whereby a low frequency signal modulates the amplitude of a higher frequency FU wave. Cavitation threshold is lower at low frequencies; the intensity required to generate cavitation in water at 10 kHz is two orders of magnitude lower than the intensity at 1 MHz. The Amplitude Modulation technique can operate in both continuous wave (CW) and pulse wave (PW) modes, and the percentage modulation (modulation index) can be varied from 0 % (thermal effect) to 100 % (cavitation effect), thus allowing a range of ablating effects from Hyperthermia to Histotripsy. Furthermore, changing the frequency of the modulating signal allows controlling the size of the generated cavities. Results from in vitro work demonstrate the efficacy of the new technique in fractionating soft tissue and solid calcium carbonate (Chalk) material. The technique, when combined with MR or Ultrasound imaging, will present a precise treatment modality for ablating diseased tissue without affecting the surrounding healthy tissue.
Abstract: This paper presents a subband adaptive filter (SAF)
for a system identification where an impulse response is sparse
and disturbed with an impulsive noise. Benefiting from the uses
of l1-norm optimization and l0-norm penalty of the weight vector
in the cost function, the proposed l0-norm sign SAF (l0-SSAF)
achieves both robustness against impulsive noise and much improved
convergence behavior than the classical adaptive filters. Simulation
results in the system identification scenario confirm that the proposed
l0-norm SSAF is not only more robust but also faster and more
accurate than its counterparts in the sparse system identification in
the presence of impulsive noise.
Abstract: This paper presents a digital non-linear pulse-width modulation (PWM) controller in a high-voltage (HV) buck-boost DC-DC converter for the piezoelectric transducer of the down-hole acoustic telemetry system. The proposed design controls the generation of output signal with voltage higher than the supply voltage and is targeted to work under high temperature. To minimize the power consumption and silicon area, a simple and efficient design scheme is employed to develop the PWM controller. The proposed PWM controller consists of serial to parallel (S2P) converter, data assign block, a mode and duty cycle controller (MDC), linearly PWM (LPWM) and noise shaper, pulse generator and clock generator. To improve the reliability of circuit operation at higher temperature, this design is fabricated with the 1.0-μm silicon-on-insulator (SOI) CMOS process. The implementation results validated that the proposed design has the advantages of smaller size, lower power consumption and robust thermal stability.
Abstract: Carrier-based methods have been used widely for switching of multilevel inverters due to their simplicity, flexibility and reduced computational requirements compared to space vector modulation (SVM). This paper focuses on Multicarrier Sinusoidal Pulse Width Modulation (MCSPWM) strategy for the three phase Five-Level Flying Capacitor Inverter (5LFCI). The inverter is simulated for Induction Motor (IM) load and Total Harmonic Distortion (THD) for output waveforms is observed for different controlling schemes.
Abstract: We present a new framework of the data-reusing (DR)
adaptive algorithms by incorporating a constraint on noise, referred
to as a noise constraint. The motivation behind this work is that the
use of the statistical knowledge of the channel noise can contribute
toward improving the convergence performance of an adaptive filter
in identifying a noisy linear finite impulse response (FIR) channel.
By incorporating the noise constraint into the cost function of the
DR adaptive algorithms, the noise constrained DR (NC-DR) adaptive
algorithms are derived. Experimental results clearly indicate their
superior performance over the conventional DR ones.
Abstract: In this study, the butt welding of the commercial AZ31 magnesium alloy sheets have been carried out by using Tungsten Inert Gas (TIG) welding process with alternative and pulsed current. Welded samples were examined with regards to hardness and microstructure. Despite some recent developments in welding of magnesium alloys, they have some problems such as porosity, hot cracking, oxide formation and so on. Samples of the welded parts have undergone metallographic and mechanical examination. Porosities and homogeneous micron grain oxides were rarely observed. Orientations of the weld microstructure in terms of heat transfer also were rarely observed and equiaxed grain morphology was dominant grain structure as in the base metal. As results, fusion zone and few locations of the HAZ of the welded samples have shown twin’s grains. Hot cracking was not observed for any samples. Weld bead geometry of the welded samples were evaluated as normal according to welding parameters. In the results, conditions of alternative and pulsed current and the samples were compared to each other with regards to microstructure and hardness.
Abstract: Measurement of the ultrasonic pulse velocity (UPV) is an important tool in diagnostic examination of concrete. In this method piezoelectric transducers are normally held in direct contact with the concrete surface. The current study aims to test the hypothesis that a preferential coupling effect might exist i.e. that the speed of sound measured depends on the couplant used. In this study, different coupling media of varying acoustic impedance were placed between the transducers and concrete samples made with constant aggregate content but with different compressive strengths. The preliminary results show that using coupling materials (both solid and a range of liquid substances) has an effect on the pulse velocity measured in a given concrete. The effect varies depending on the material used. The UPV measurements with solid coupling were higher than these from the liquid coupling at all strength levels. The tests using couplants generally recorded lower UPV values than the conventional test, except when carbon fiber composite was used, which retuned higher values. Analysis of variances (ANOVA) was performed to confirm that there are statistically significant differences between the measurements recorded using a conventional system and a coupled system.
Abstract: In this paper, an improved active snubber cell is proposed on account of soft switching (SS) family of pulse width modulation (PWM) DC-DC converters. The improved snubber cell provides zero-voltage transition (ZVT) turn on and zero-current transition (ZCT) turn off for main switch. The snubber cell decreases EMI noise and operates with SS in a wide range of line and load voltages. Besides, all of the semiconductor devices in the converter operate with SS. There is no additional voltage and current stress on the main devices. Additionally, extra voltage stress does not occur on the auxiliary switch and its current stress is acceptable value. The improved converter has a low cost and simple structure. The theoretical analysis of converter is clarified and the operating states are given in detail. The experimental results of converter are obtained by prototype of 500 W and 100 kHz. It is observed that the experimental results and theoretical analysis of converter are suitable with each other perfectly.
Abstract: To focus on the vibration mode of a cone loudspeaker,
which acts as an electroacoustic transducer, excitation experiments
were performed using two types of loudspeaker units: one employing
an impulse hammer and the other a sweep signal. The on-axis sound
pressure frequency properties of the loudspeaker were evaluated, and
the characteristic properties of the loudspeakers were successfully
determined in both excitation experiments. Moreover, under
conditions identical to the experiment conditions, a coupled analysis of
the vibration-acoustics of the cone loudspeaker was performed using
an acoustic analysis software program that considers the impact of
damping caused by air viscosity. The result of sound pressure
frequency properties with the numerical analysis are the most closely
match that measured in the excitation experiments over a wide range
of frequency bands.
Abstract: An experiment to verify the relationships between
physiological indexes of an e-learner and the presence or absence of an
operation during e-learning is described. Electroencephalogram
(EEG), hemoencephalography (HEG), skin conductance (SC), and
blood volume pulse (BVP) values were measured while participants
performed experimental learning tasks. The results show that there are
significant differences between the SC values when reading with
clicking on learning materials and the SC values when reading without
clicking, and between the HEG ratio when reading (with and without
clicking) and the HEG ratio when resting for four of five participants.
We conclude that the SC signals can be used to estimate whether or not
a learner is performing an active task and that the HEG ratios can be
used to estimate whether a learner is learning.
Abstract: In general, it is desirable to finish the weld quickly,
before a large volume of surrounding metal heats up and expands.
The welding process used, type, welding current and speed of travel,
thus, affect the degree of shrinkage and distortion of a weldment. The
use of mechanized welding equipment reduces welding time, metal
affected zone and consequently distortion. This article helps to define
what weld distortion is and then provide a practical understanding of
the causes of distortion, effects of shrinkage in butt joint welded
assemblies using TI6AL4VA and Aluminium AA2024 alloy sheet.
The beam offset position to the joint interface towards titanium and
aluminium side. The factors affecting distortion during welding is
also given. Test results reveal that welding speed is the significant
parameter to decide the extent of distortion. Also welding from Al
side reduces the distortion while Ti side increases the distortion.
Abstract: Interaction between mixing and crystallization is often
ignored despite the fact that it affects almost every aspect of the
operation including nucleation, growth, and maintenance of the
crystal slurry. This is especially pronounced in multiple impeller
systems where flow complexity is increased. By choosing proper
mixing parameters, what closely depends on the knowledge of the
hydrodynamics in a mixing vessel, the process of batch cooling
crystallization may considerably be improved. The values that render
useful information when making this choice are mixing time and
power consumption. The predominant motivation for this work was
to investigate the extent to which radial dual impeller configuration
influences mixing time, power consumption and consequently the
values of metastable zone width and nucleation rate. In this research,
crystallization of borax was conducted in a 15 dm3 baffled batch
cooling crystallizer with an aspect ratio (H/T) of 1.3. Mixing was
performed using two straight blade turbines (4-SBT) mounted on the
same shaft that generated radial fluid flow. Experiments were
conducted at different values of N/NJS ratio (impeller speed/
minimum impeller speed for complete suspension), D/T ratio
(impeller diameter/crystallizer diameter), c/D ratio (lower impeller
off-bottom clearance/impeller diameter), and s/D ratio (spacing
between impellers/impeller diameter). Mother liquor was saturated at
30°C and was cooled at the rate of 6°C/h. Its concentration was
monitored in line by Na-ion selective electrode. From the values of
supersaturation that was monitored continuously over process time, it
was possible to determine the metastable zone width and
subsequently the nucleation rate using the Mersmann’s nucleation
criterion. For all applied dual impeller configurations, the mixing
time was determined by potentiometric method using a pulse
technique, while the power consumption was determined using a
torque meter produced by Himmelstein & Co. Results obtained in
this investigation show that dual impeller configuration significantly
influences the values of mixing time, power consumption as well as
the metastable zone width and nucleation rate. A special attention
should be addressed to the impeller spacing considering the flow
interaction that could be more or less pronounced depending on the
spacing value.
Abstract: In this paper, an Infinite Impulse Response (IIR) filter
has been designed and simulated on an Field Programmable Gate
Arrays (FPGA). The implementation is based on Multiply Add and
Accumulate (MAC) algorithm which uses multiply operations for
design implementation. Parallel Pipelined structure is used to
implement the proposed IIR Filter taking optimal advantage of the
look up table of target device. The designed filter has been
synthesized on Digital Signal Processor (DSP) slice based FPGA to
perform multiplier function of MAC unit. The DSP slices are useful
to enhance the speed performance. The proposed design is simulated
with Matlab, synthesized with Xilinx Synthesis Tool, and
implemented on FPGA devices. The Virtex 5 FPGA based design can
operate at an estimated frequency of 81.5 MHz as compared to 40.5
MHz in case of Spartan 3 ADSP based design. The Virtex 5 based
implementation also consumes less slices and slice flip flops of target
FPGA in comparison to Spartan 3 ADSP based implementation to
provide cost effective solution for signal processing applications.
Abstract: Brushless DC motors (BLDC) are widely used in
industrial areas. The BLDC motors are driven either by indirect ACAC
converters or by direct AC-AC converters. Direct AC-AC
converters i.e. matrix converters are used in this paper to drive the
three phase BLDC motor and it eliminates the bulky DC link energy
storage element. A matrix converter converts the AC power supply to
an AC voltage of variable amplitude and variable frequency. A
control technique is designed to generate the switching pulses for the
three phase matrix converter. For the control of speed of the BLDC
motor a separate PI controller and Fuzzy Logic Controller (FLC) are
designed and a hysteresis current controller is also designed for the
control of motor torque. The control schemes are designed and tested
separately. The simulation results of both the schemes are compared
and contrasted in this paper. The results show that the fuzzy logic
control scheme outperforms the PI control scheme in terms of
dynamic performance of the BLDC motor. Simulation results are
validated with the experimental results.