Abstract: Alkaline niobate (Na0.5K0.5)NbO3 ceramic system has attracted major attention in view of its potential for replacing the highly toxic but superior lead zirconate titanate (PZT) system for piezoelectric applications. Recently, a more detailed study of this system reveals that the ferroelectric and piezoelectric properties are optimized in the Li- and V-modified system having the composition (K0.485Na0.5Li0.015)(Nb0.98V0.02)O3. In the present work, we further study the pyroelectric behaviour of this composition along with another doped with Mn4+. So, (K0.485Na0.5Li0.015)(Nb0.98V0.02)O3 + x MnO2 (x = 0, and 0.01 wt. %) ceramic compositions were synthesized by conventional ceramic processing route. X-ray diffraction study reveals that both the undoped and Mn4+-doped ceramic samples prepared crystallize into a perovskite structure having orthorhombic symmetry. Dielectric study indicates that Mn4+ doping has little effect on both the Curie temperature (Tc) and tetragonal-orthorhombic phase transition temperature (Tot). The bulk density, room-temperature dielectric constant (εRT), and room-c The room-temperature coercive field (Ec) is observed to be lower in Mn4+ doped sample. The detailed analysis of the P-E hysteresis loops over the range of temperature from about room temperature to Tot points out that enhanced ferroelectric properties exist in this temperature range with better thermal stability for the Mn4+ doped ceramic. The study reveals that small traces of Mn4+ can modify (K0.485Na0.5Li0.015)(Nb0.98V0.02)O3 system so as to improve its ferroelectric properties with good thermal stability over a wide range of temperature.
Abstract: In this paper, an advanced Nonlinear Exponential
Model (NEM), able to simulate the uniaxial dynamic behavior of
seismic isolators having a continuously decreasing tangent stiffness
with increasing displacement in the relatively large displacements
range and a hardening or softening behavior at large displacements, is
presented. The mathematical model is validated by comparing the
experimental force-displacement hysteresis loops obtained during
cyclic tests, conducted on a helical wire rope isolator and a recycled
rubber-fiber reinforced bearing, with those predicted analytically.
Good agreement between the experimental and simulated results
shows that the proposed model can be an effective numerical tool to
predict the force-displacement relationship of seismic isolation
devices within the large displacements range. Compared to the
widely used Bouc-Wen model, unable to simulate the response of
seismic isolators at large displacements, the proposed one allows to
avoid the numerical solution of a first order nonlinear ordinary
differential equation for each time step of a nonlinear time history
analysis, thus reducing the computation effort. Furthermore, the
proposed model can simulate the smooth transition of the hysteresis
loops from small to large displacements by adopting only one set of
five parameters determined from the experimental hysteresis loops
having the largest amplitude.
Abstract: In this paper, the results of experimental tests
performed on a Helical Wire Rope Isolator (HWRI) are presented in
order to describe the dynamic and static behavior of the selected
metal device in three different displacements ranges, namely small,
relatively large, and large displacements ranges, without and under
the effect of a vertical load. A testing machine, allowing to apply
horizontal displacement or load histories to the tested bearing with a
constant vertical load, has been adopted to perform the dynamic and
static tests. According to the experimental results, the dynamic
behavior of the tested device depends on the applied displacement
amplitude. Indeed, the HWRI displays a softening and a hardening
stiffness at small and relatively large displacements, respectively, and
a stronger nonlinear stiffening behavior at large displacements.
Furthermore, the experimental tests reveal that the application of a
vertical load allows to have a more flexible device with higher
damping properties and that the applied vertical load affects much
less the dynamic response of the metal device at large displacements.
Finally, a decrease in the static to dynamic effective stiffness ratio
with increasing displacement amplitude has been observed.
Abstract: In this paper, a one-dimensional (1d) Parallel Elasto-
Plastic Model (PEPM), able to simulate the uniaxial dynamic
behavior of seismic isolators having a continuously decreasing
tangent stiffness with increasing displacement, is presented. The
parallel modeling concept is applied to discretize the continuously
decreasing tangent stiffness function, thus allowing to simulate the
dynamic behavior of seismic isolation bearings by putting linear
elastic and nonlinear elastic-perfectly plastic elements in parallel. The
mathematical model has been validated by comparing the
experimental force-displacement hysteresis loops, obtained testing a
helical wire rope isolator and a recycled rubber-fiber reinforced
bearing, with those predicted numerically. Good agreement between
the simulated and experimental results shows that the proposed
model can be an effective numerical tool to predict the forcedisplacement
relationship of seismic isolators within relatively large
displacements. Compared to the widely used Bouc-Wen model, the
proposed one allows to avoid the numerical solution of a first order
ordinary nonlinear differential equation for each time step of a
nonlinear time history analysis, thus reducing the computation effort,
and requires the evaluation of only three model parameters from
experimental tests, namely the initial tangent stiffness, the asymptotic
tangent stiffness, and a parameter defining the transition from the
initial to the asymptotic tangent stiffness.
Abstract: It has been shown that BaFe12O19 is a perspective room-temperature multiferroic material. A large spontaneous polarization was observed for the BaFe12O19 ceramics revealing a clear ferroelectric hysteresis loop. The maximum polarization was estimated to be approximately 11.8 μC/cm2. The FeO6 octahedron in its perovskite-like hexagonal unit cell and the shift of Fe3+ off the center of octahedron are suggested to be the origin of the polarization in BaFe12O19. The magnetic field induced electric polarization has been also observed in the doped BaFe12-x-δScxMδO19 (δ=0.05) at 10 K and in the BaScxFe12−xO19 and SrScxFe12−xO19 (x = 1.3–1.7) M-type hexaferrites. The investigated BaFe12-xDxO19 (x=0.1, D-Al3+, In3+) samples have been obtained by two-step “topotactic” reactions. The powder neutron investigations of the samples were performed by neutron time of flight method at High Resolution Fourier Diffractometer.
Abstract: Passive control methods can be utilized to build
earthquake resistant structures, and also to strengthen the vulnerable
ones. In this paper, we studied the effect of this system in increasing
the ductility and energy dissipation and also modeled the behavior of
this type of eccentric bracing, and compared the hysteresis diagram
of the modeled samples with the laboratory samples. We studied
several samples of frames with vertical shear-links in order to assess
the behavior of this type of eccentric bracing. Each of these samples
was modeled in finite element software ANSYS 9.0, and was
analyzed under the static cyclic loading. It was found that vertical
shear-links have a more stable hysteresis loops. Another analysis
showed that using honeycomb beams as the horizontal beam along
with steel reinforcement has no negative effect on the hysteresis
behavior of the sample.
Abstract: Precast residential houses are normally constructed in Malaysia using precast shear-key wall panel and this panel is designed using BS8110 where there is no provision for earthquake. However, the safety of this house under moderate and strong earthquake is still questionable. Consequently, the full-scale of residential house are designed, constructed, tested and analyzed under in-plane lateral quasi-static cyclic loading. Hysteresis loops are plotted based on the experimental work and compared with modeling of hysteresis loops using HYSTERES in RUAUMOKO 2D program. Modified Takeda hysteresis model is chosen to behave a similar pattern with experimental work. This program will display the earthquake excitations, spectral displacements, pseudo spectral acceleration, mode shape and deformation of the structure. It can be concluded that this building is suffering severe cracks and damage under moderate and severe earthquake.
Abstract: The unsteady flow field around oscillating OA-209 airfoil at a Reynolds number of 3.5×105 were investigated. Three different reduced frequencies were tested in order to see how it affects the hysteresis loop of an airfoil. At a reduced frequency of 0.05 the deep dynamic stall phenomenon was observed. Lift overshooting was observed as a result of dynamic stall vortex (DSV) shedding. Further investigation was carried out to find out the cause of DSV formation and shedding over airfoil. Particle image velocimetry (PIV) and CFD tools were used and it was found out that dynamic stall separation (DSS), which is separated from leading edge separation (LES) and trailing edge separation (TES), triggered the dynamic stall vortex (DSV).
Abstract: This paper presents the retrofitting of beam-column joint using CFRP (Carbon Fiber Reinforced Polymer) and steel plate. This specimen was tested until failure up to 1.0% drift. This joint suffered severe damages and diagonal cracks at upper crack at upper column before retrofitted. CFRP were wrapped at corbel, bottom and top of the column. Steel plates with bonding were attached to the two beams and the jointing system. This retrofitted specimen is tested again under lateral cyclic loading up 1.75% drift. Visual observations show that the cracks started at joint when 0.5% drift applied at top of column. Damage of retrofitted beam-column joint occurred inside the CFRP and it cannot be seen from outside. Analysis of elastic stiffness, lateral strength, ductility, hysteresis loops and equivalent viscous damping shows that these values are higher than before retrofitting. Therefore, it is recommended to use this type of retrofitting method for beam-column joint with corbel which suffers severe damage after the earthquake.
Abstract: Fatigue behaviors of Lead Zirconate Titanate (PZT)
ceramics under different amplitude of bipolar electrical loads have
been investigated. Fatigue behavior is represented by the change of
hysteresis loops and remnant polarization. Three levels of electrical
load amplitudes (1.00, 1.25 and 1.50 kV /mm) were applied in this
experimental. It was found that the remnant polarization decreased
significantly with the number of loading cycles. The degree of fatigue
degradation depends on the amplitude of electric field. The higher
amplitude exhibits the greater fatigue degradation.
Abstract: The ferroelectric behavior of barium strontium
titanate (BST) in thin film form has been investigated in order to
study the possibility of using BST for ferroelectric gate-field effect
transistor (FeFET) for memory devices application. BST thin films
have been fabricated as Al/BST/Pt/SiO2/Si-gate configuration. The
variation of the dielectric constant (ε) and tan δ with frequency have
been studied to ensure the dielectric quality of the material. The
results show that at low frequencies, ε increases as the Ba content
increases, whereas at high frequencies, it shows the opposite
variation, which is attributed to the dipole dynamics. tan δ shows low
values with a peak at the mid-frequency range. The ferroelectric
behavior of the Al/BST/Pt/SiO2/Si has been investigated using C-V
characteristics. The results show that the strength of the ferroelectric
hysteresis loop increases as the Ba content increases; this is attributed
to the grain size and dipole dynamics effect.
Abstract: Un-doped GaN film of thickness 1.90 mm, grown on
sapphire substrate were uniformly implanted with 325 keV Mn+ ions
for various fluences varying from 1.75 x 1015 - 2.0 x 1016 ions cm-2 at
3500 C substrate temperature. The structural, morphological and
magnetic properties of Mn ion implanted gallium nitride samples
were studied using XRD, AFM and SQUID techniques. XRD of the
sample implanted with various ion fluences showed the presence of
different magnetic phases of Ga3Mn, Ga0.6Mn0.4 and Mn4N.
However, the compositions of these phases were found to be
depended on the ion fluence. AFM images of non-implanted sample
showed micrograph with rms surface roughness 2.17 nm. Whereas
samples implanted with the various fluences showed the presence of
nano clusters on the surface of GaN. The shape, size and density of
the clusters were found to vary with respect to ion fluence. Magnetic
moment versus applied field curves of the samples implanted with
various fluences exhibit the hysteresis loops. The Curie temperature
estimated from zero field cooled and field cooled curves for the
samples implanted with the fluence of 1.75 x 1015, 1.5 x 1016 and 2.0
x 1016 ions cm-2 was found to be 309 K, 342 K and 350 K
respectively.