Abstract: Elastomeric bearings (EB) are used in many applications, such as base isolation of bridges, seismic protection and vibration control of other structures and machinery. Their versatility is due to their particular behavior since they have different stiffness in the vertical and horizontal directions, allowing to sustain vertical loads and at the same time horizontal displacements. Therefore, vertical, horizontal and bending stiffnesses are important parameters to take into account in the design of EB. In order to acquire a proper design methodology of EB all three, theoretical, finite element analysis and experimental, approaches should be taken into account to assess stability due to different loading states, predict their behavior and consequently their effects on the dynamic response of structures, and understand complex behavior and properties of rubber-like materials respectively. In particular, the recent large-displacement theory on the stability of EB formulated by Forcellini and Kelly is validated with both numerical simulations using the finite element method, and experimental results set at the University of Antioquia in Medellin, Colombia. In this regard, this study reproduces the behavior of EB under compression loads and investigates the stability behavior with the three mentioned points of view.
Abstract: The nonlinear time history analysis of seismically base-isolated structures can require a significant computational effort when the behavior of each seismic isolator is predicted by adopting the widely used differential equation Bouc-Wen model. In this paper, a nonlinear exponential model, able to simulate the response of seismic isolation bearings within a relatively large displacements range, is described and adopted in order to reduce the numerical computations and speed up the nonlinear dynamic analysis. Compared to the Bouc-Wen model, the proposed one does not require the numerical solution of a nonlinear differential equation for each time step of the analysis. The seismic response of a 3d base-isolated structure with a lead rubber bearing system subjected to harmonic earthquake excitation is simulated by modeling each isolator using the proposed analytical model. The comparison of the numerical results and computational time with those obtained by modeling the lead rubber bearings using the Bouc-Wen model demonstrates the good accuracy of the proposed model and its capability to reduce significantly the computational effort of the analysis.
Abstract: In order to reduce numerical computations in the
nonlinear dynamic analysis of seismically base-isolated structures, a
Mixed Explicit-Implicit time integration Method (MEIM) has been
proposed. Adopting the explicit conditionally stable central
difference method to compute the nonlinear response of the base
isolation system, and the implicit unconditionally stable Newmark’s
constant average acceleration method to determine the superstructure
linear response, the proposed MEIM, which is conditionally stable
due to the use of the central difference method, allows to avoid the
iterative procedure generally required by conventional monolithic
solution approaches within each time step of the analysis. The main
aim of this paper is to investigate the stability and computational
efficiency of the MEIM when employed to perform the nonlinear
time history analysis of base-isolated structures with sliding bearings.
Indeed, in this case, the critical time step could become smaller than
the one used to define accurately the earthquake excitation due to the
very high initial stiffness values of such devices. The numerical
results obtained from nonlinear dynamic analyses of a base-isolated
structure with a friction pendulum bearing system, performed by
using the proposed MEIM, are compared to those obtained adopting a
conventional monolithic solution approach, i.e. the implicit
unconditionally stable Newmark’s constant acceleration method
employed in conjunction with the iterative pseudo-force procedure.
According to the numerical results, in the presented numerical
application, the MEIM does not have stability problems being the
critical time step larger than the ground acceleration one despite of
the high initial stiffness of the friction pendulum bearings. In
addition, compared to the conventional monolithic solution approach,
the proposed algorithm preserves its computational efficiency even
when it is adopted to perform the nonlinear dynamic analysis using a
smaller time step.
Abstract: In this paper, an advanced Nonlinear Exponential
Model (NEM), able to simulate the uniaxial dynamic behavior of
seismic isolators having a continuously decreasing tangent stiffness
with increasing displacement in the relatively large displacements
range and a hardening or softening behavior at large displacements, is
presented. The mathematical model is validated by comparing the
experimental force-displacement hysteresis loops obtained during
cyclic tests, conducted on a helical wire rope isolator and a recycled
rubber-fiber reinforced bearing, with those predicted analytically.
Good agreement between the experimental and simulated results
shows that the proposed model can be an effective numerical tool to
predict the force-displacement relationship of seismic isolation
devices within the large displacements range. Compared to the
widely used Bouc-Wen model, unable to simulate the response of
seismic isolators at large displacements, the proposed one allows to
avoid the numerical solution of a first order nonlinear ordinary
differential equation for each time step of a nonlinear time history
analysis, thus reducing the computation effort. Furthermore, the
proposed model can simulate the smooth transition of the hysteresis
loops from small to large displacements by adopting only one set of
five parameters determined from the experimental hysteresis loops
having the largest amplitude.
Abstract: In this paper, the results of experimental tests
performed on a Helical Wire Rope Isolator (HWRI) are presented in
order to describe the dynamic and static behavior of the selected
metal device in three different displacements ranges, namely small,
relatively large, and large displacements ranges, without and under
the effect of a vertical load. A testing machine, allowing to apply
horizontal displacement or load histories to the tested bearing with a
constant vertical load, has been adopted to perform the dynamic and
static tests. According to the experimental results, the dynamic
behavior of the tested device depends on the applied displacement
amplitude. Indeed, the HWRI displays a softening and a hardening
stiffness at small and relatively large displacements, respectively, and
a stronger nonlinear stiffening behavior at large displacements.
Furthermore, the experimental tests reveal that the application of a
vertical load allows to have a more flexible device with higher
damping properties and that the applied vertical load affects much
less the dynamic response of the metal device at large displacements.
Finally, a decrease in the static to dynamic effective stiffness ratio
with increasing displacement amplitude has been observed.
Abstract: In this paper, a one-dimensional (1d) Parallel Elasto-
Plastic Model (PEPM), able to simulate the uniaxial dynamic
behavior of seismic isolators having a continuously decreasing
tangent stiffness with increasing displacement, is presented. The
parallel modeling concept is applied to discretize the continuously
decreasing tangent stiffness function, thus allowing to simulate the
dynamic behavior of seismic isolation bearings by putting linear
elastic and nonlinear elastic-perfectly plastic elements in parallel. The
mathematical model has been validated by comparing the
experimental force-displacement hysteresis loops, obtained testing a
helical wire rope isolator and a recycled rubber-fiber reinforced
bearing, with those predicted numerically. Good agreement between
the simulated and experimental results shows that the proposed
model can be an effective numerical tool to predict the forcedisplacement
relationship of seismic isolators within relatively large
displacements. Compared to the widely used Bouc-Wen model, the
proposed one allows to avoid the numerical solution of a first order
ordinary nonlinear differential equation for each time step of a
nonlinear time history analysis, thus reducing the computation effort,
and requires the evaluation of only three model parameters from
experimental tests, namely the initial tangent stiffness, the asymptotic
tangent stiffness, and a parameter defining the transition from the
initial to the asymptotic tangent stiffness.
Abstract: The solution of the nonlinear dynamic equilibrium equations of base-isolated structures adopting a conventional monolithic solution approach, i.e. an implicit single-step time integration method employed with an iteration procedure, and the use of existing nonlinear analytical models, such as differential equation models, to simulate the dynamic behavior of seismic isolators can require a significant computational effort. In order to reduce numerical computations, a partitioned solution method and a one dimensional nonlinear analytical model are presented in this paper. A partitioned solution approach can be easily applied to base-isolated structures in which the base isolation system is much more flexible than the superstructure. Thus, in this work, the explicit conditionally stable central difference method is used to evaluate the base isolation system nonlinear response and the implicit unconditionally stable Newmark’s constant average acceleration method is adopted to predict the superstructure linear response with the benefit in avoiding iterations in each time step of a nonlinear dynamic analysis. The proposed mathematical model is able to simulate the dynamic behavior of seismic isolators without requiring the solution of a nonlinear differential equation, as in the case of widely used differential equation model. The proposed mixed explicit-implicit time integration method and nonlinear exponential model are adopted to analyze a three dimensional seismically isolated structure with a lead rubber bearing system subjected to earthquake excitation. The numerical results show the good accuracy and the significant computational efficiency of the proposed solution approach and analytical model compared to the conventional solution method and mathematical model adopted in this work. Furthermore, the low stiffness value of the base isolation system with lead rubber bearings allows to have a critical time step considerably larger than the imposed ground acceleration time step, thus avoiding stability problems in the proposed mixed method.
Abstract: Use of base isolators in the seismic design of structures has attracted considerable attention in recent years. The major concern in the design of these structures is to have enough lateral stability to resist wind and seismic forces. There are different systems providing such isolation, among them there are friction- pendulum base isolation systems (FPS) which are rather widely applied nowadays involving to both affordable cost and high fundamental periods. These devices are characterised by a stiff resistance against wind loads and to be flexible to the seismic tremors, which make them suitable for different situations. In this paper, a 3D numerical investigation is done considering the seismic response of a twelve-storey steel building retrofitted with a FPS. Fast nonlinear time history analysis (FNA) of Boumerdes earthquake (Algeria, May 2003) is considered for analysis and carried out using SAP2000 software. Comparisons between fixed base, bearing base isolated and braced structures are shown in a tabulated and graphical format. The results of the various alternatives studies to compare the structural response without and with this device of dissipation energy thus obtained were discussed and the conclusions showed the interesting potential of the FPS isolator. This system may to improve the dissipative capacities of the structure without increasing its rigidity in a significant way which contributes to optimize the quantity of steel necessary for its general stability.
Abstract: In this study, control performance of a smart base
isolation system consisting of a friction pendulum system (FPS) and a
magnetorheological (MR) damper has been investigated. A fuzzy
logic controller (FLC) is used to modulate the MR damper so as to
minimize structural acceleration while maintaining acceptable base
displacement levels. To this end, a multi-objective optimization
scheme is used to optimize parameters of membership functions and
find appropriate fuzzy rules. To demonstrate effectiveness of the
proposed multi-objective genetic algorithm for FLC, a numerical
study of a smart base isolation system is conducted using several
historical earthquakes. It is shown that the proposed method can find
optimal fuzzy rules and that the optimized FLC outperforms not only a
passive control strategy but also a human-designed FLC and a
conventional semi-active control algorithm.
Abstract: In order to improve the effect of isolation structure, the
principles and behaviours of the base-isolation system are studied, and
the types and characteristics of the base-isolation are also discussed.
Compared to the traditional aseismatic structures, the base isolation
structures decrease the seismic response obviously: the total structural
aseismatic value decreases to 1/4-1/32 and the seismic shear stress in
the upper structure decreases to 1/14-1/23. In the huge seism, the
structure can have an obvious aseismatic effect.
Abstract: Analytical seismic response of multi-story building
supported on base isolation system is investigated under real
earthquake motion. The superstructure is idealized as a shear type
flexible building with lateral degree-of-freedom at each floor. The
force-deformation behaviour of the isolation system is modelled by
the bi-linear behaviour which can be effectively used to model all
isolation systems in practice. The governing equations of motion of
the isolated structural system are derived. The response of the system
is obtained numerically by step-by-method under three real recorded
earthquake motions and pulse motions associated in the near-fault
earthquake motion. The variation of the top floor acceleration, interstory
drift, base shear and bearing displacement of the isolated
building is studied under different initial stiffness of the bi-linear
isolation system. It was observed that the high initial stiffness of the
isolation system excites higher modes in base-isolated structure and
generate floor accelerations and story drift. Such behaviour of the
base-isolated building especially supported on sliding type of
isolation systems can be detrimental to sensitive equipment installed
in the building. On the other hand, the bearing displacement and base
shear found to reduce marginally with the increase of the initial
stiffness of the initial stiffness of the isolation system. Further, the
above behaviour of the base-isolated building was observed for
different parameters of the bearing (i.e. post-yield stiffness and
characteristic strength) and earthquake motions (i.e. real time history
as well as pulse type motion).
Abstract: In order to upgrade the seismic resistibility of structures and enhance the functionality of an isolator, a new base isolator called the multiple trench friction pendulum system (MTFPS) is proposed in this study. The proposed MTFPS isolator is composed of a trench concave surface and several intermediate sliding plates in two orthogonal directions. Mathematical formulations have been derived to examine the characteristics of the proposed MTFPS isolator possessing multiple intermediate sliding plates. By means of mathematical formulations, it can be inferred that the natural period and damping effect of the MTFPS isolator with several intermediate sliding plates can be altered continually and controllably during earthquakes. Furthermore, results obtained from shaking table tests demonstrate that the proposed isolator provides good protection to structures for prevention of damage from strong earthquakes.
Abstract: A seismic isolation pad produced by utilizing the scrap
tire rubber which contains interleaved steel reinforcing cords has been
proposed. The steel cords are expected to function similar to the steel
plates used in conventional laminated rubber bearings. The scrap tire
rubber pad (STRP) isolator is intended to be used in low rise
residential buildings of highly seismic areas of the developing
countries. Experimental investigation was conducted on unbonded
STRP isolators, and test results provided useful information including
stiffness, damping values and an eventual instability of the isolation
unit. Finite element analysis (FE analysis) of STRP isolator was
carried out on properly bonded samples. These types of isolators
provide positive incremental force resisting capacity up to shear strain
level of 155%. This paper briefly discusses the force deformation
behavior of bonded STRP isolators including stability of the isolation
unit.