Abstract: The architectural and structural analysis of selected high-rise buildings in Tokyo is presented in this paper. The capital of Japan is the most densely populated city in the world and moreover is located in one of the most active seismic zones. The combination of these factors has resulted in the creation of sophisticated designs and innovative engineering solutions, especially in the field of design and construction of high-rise buildings. The foreign architectural studios (as, for Jean Nouvel, Kohn Pedesen Associates, Skidmore, Owings & Merill) which specialize in the designing of skyscrapers, played a major role in the development of technological ideas and architectural forms for such extraordinary engineering structures. Among the projects completed by them, there are examples of high-rise buildings that set precedents for future development. An essential aspect which influences the design of high-rise buildings is the necessity to take into consideration their dynamic reaction to earthquakes and counteracting wind vortices. The need to control motions of these buildings, induced by the force coming from earthquakes and wind, led to the development of various methods and devices for dissipating energy which occur during such phenomena. Currently, Japan is a global leader in seismic technologies which safeguard seismic influence on high-rise structures. Due to these achievements the most modern skyscrapers in Tokyo are able to withstand earthquakes with a magnitude of over seven degrees at the Richter scale. Damping devices applied are of a passive, which do not require additional power supply or active one which suppresses the reaction with the input of extra energy. In recent years also hybrid dampers were used, with an additional active element to improve the efficiency of passive damping.
Abstract: Generally, different rods in shaft systems can be misaligned based on the mechanical system usages. These rods can be linked together via U-coupling easily. The system is self-stimulated and may cause instabilities due to the inherent behavior of the coupling. In this study, each rod includes an elastic shaft with an angular stiffness and structural damping. Moreover, the mass of shafts is considered via attached solid disks. The impact of the system architecture and shaft mass on the instability of such mechanism are studied. Stability charts are plotted via a method based on Floquet theory. Eventually, the unstable points have been found and analyzed in detail. The results show that stabilizing the driveline is feasible by changing the system characteristics which include shaft mass and architecture.
Abstract: Passive resonant vibration absorbers are among the most widely used dynamic control systems in civil engineering. They typically consist in a single-degree-of-freedom mechanical appendage of the main structure, tuned to one structural target mode through frequency and damping optimization. One classical scheme is the pendulum absorber, whose mass is constrained to move along a curved trajectory and is damped by viscous dashpots. Even though the principle is well known, the search for improved arrangements is still under way. In recent years this investigation inspired a type of bidirectional pendulum absorber (BPA), consisting of a mass constrained to move along an optimal three-dimensional (3D) concave surface. For such a BPA, the surface principal curvatures are designed to ensure a bidirectional tuning of the absorber to both principal modes of the main structure, while damping is produced either by horizontal viscous dashpots or by vertical friction dashpots, connecting the BPA to the main structure. In this paper, a variant of BPA is proposed, where damping originates from the variable tangential friction force which develops between the pendulum mass and the 3D surface as a result of a spatially-varying friction coefficient pattern. Namely, a friction coefficient is proposed that varies along the pendulum surface in proportion to the modulus of the 3D surface gradient. With such an assumption, the dissipative model of the absorber can be proven to be nonlinear homogeneous in the small displacement domain. The resulting homogeneous BPA (HBPA) has a fundamental advantage over conventional friction-type absorbers, because its equivalent damping ratio results independent on the amplitude of oscillations, and therefore its optimal performance does not depend on the excitation level. On the other hand, the HBPA is more compact than viscously damped BPAs because it does not need the installation of dampers. This paper presents the analytical model of the HBPA and an optimal methodology for its design. Numerical simulations of single- and multi-story building structures under wind and earthquake loads are presented to compare the HBPA with classical viscously damped BPAs. It is shown that the HBPA is a promising alternative to existing BPA types and that homogeneous tangential friction is an effective means to realize systems provided with amplitude-independent damping.
Abstract: This study investigates the benefits of implementing the semi-active devices in relation to passive viscous damping in the context of seismically isolated bridge structures. Since the intrinsically nonlinear nature of semi-active devices prevents the direct evaluation of Laplace transforms, frequency response functions are compiled from the computed time history response to sinusoidal and pulse-like seismic excitation. A simple semi-active control policy is used in regard to passive linear viscous damping and an optimal non-causal semi-active control strategy. The control strategy requires optimization. Euler-Lagrange equations are solved numerically during this procedure. The optimal closed-loop performance is evaluated for an idealized controllable dash-pot. A simplified single-degree-of-freedom model of an isolated bridge is used as numerical example. Two bridge cases are investigated. These cases are; bridge deck without the isolation bearing and bridge deck with the isolation bearing. To compare the performances of the passive and semi-active control cases, frequency dependent acceleration, velocity and displacement response transmissibility ratios Ta(w), Tv(w), and Td(w) are defined. To fully investigate the behavior of the structure subjected to the sinusoidal and pulse type excitations, different damping levels are considered. Numerical results showed that, under the effect of external excitation, bridge deck with semi-active control showed better structural performance than the passive bridge deck case.
Abstract: The dynamic performance of a 4-way solenoid operated hydraulic spool valve has been analyzed by means of a one-dimensional modeling approach capturing flow, magnetic and fluid forces, valve inertia forces, fluid compressibility, and damping. Increased model accuracy was achieved by analyzing the detailed three-dimensional electromagnetic behavior of the solenoids and flow behavior through the spool valve body for a set of relevant operating conditions, thereby allowing the accurate mapping of flow and magnetic forces on the moving valve body, in lieu of representing the respective forces by lower-order models or by means of simplistic textbook correlations. The resulting high-fidelity one-dimensional model provided the basis for specific and timely design modification eliminating experimentally observed valve oscillations.
Abstract: This paper presents a numerical investigation on the seismic performance of a benchmark bridge with different optimal isolation systems under near fault ground motion. Usually, very large displacements make seismic isolation an unfeasible solution due to boundary conditions, especially in case of existing bridges or high risk seismic regions. Hence, near-fault ground motions are most likely to affect either structures with long natural period range like isolated structures or structures sensitive to velocity content such as viscously damped structures. The work is aimed at analyzing the seismic performance of a three-span continuous bridge designed with different isolation systems having different levels of damping. The case study was analyzed in different configurations including: (a) simply supported, (b) isolated with lead rubber bearings (LRBs), (c) isolated with rubber isolators and 10% classical damping (HDLRBs), and (d) isolated with rubber isolators and 70% supplemental damping ratio. Case (d) represents an alternative control strategy that combines the effect of seismic isolation with additional supplemental damping trying to take advantages from both solutions. The bridge is modeled in SAP2000 and solved by time history direct-integration analyses under a set of six recorded near-fault ground motions. In addition to this, a set of analysis under Italian code provided seismic action is also conducted, in order to evaluate the effectiveness of the suggested optimal control strategies under far field seismic action. Results of the analysis demonstrated that an isolated bridge equipped with HDLRBs and a total equivalent damping ratio of 70% represents a very effective design solution for both mitigation of displacement demand at the isolation level and base shear reduction in the piers also in case of near fault ground motion.
Abstract: The thermal damping of a dynamic vibrating micromirror is an important factor affecting the design of MEMS based actuator systems. In the development process of new micromirror systems, assessing the extent of energy loss due to thermal damping accurately and predicting the performance of the system is very essential. In this paper, the depth of the thermal penetration layer at different eigenfrequencies and the temperature variation distributions surrounding a vibrating micromirror is analyzed. The thermal penetration depth corresponds to the thermal boundary layer in which energy is lost which is a measure of the thermal damping is found out. The energy is mainly dissipated in the thermal boundary layer and thickness of the layer is an important parameter. The detailed thermoacoustics is used to model the air domain surrounding the micromirror. The thickness of the boundary layer, temperature variations and thermal power dissipation are analyzed for a Si based torsional mode micromirror. It is found that thermal penetration depth decreases with eigenfrequency and hence operating the micromirror at higher frequencies is essential for reducing thermal damping. The temperature variations and thermal power dissipations at different eigenfrequencies are also analyzed. Both frequency-response and eigenfrequency analyses are done using COMSOL Multiphysics software.
Abstract: In this paper, a theoretical investigation on the dynamic characteristics of one degree of freedom vibration system equipped with inerter of variable inertance, is presented. Differential equation of movement was solved under proper initial conditions in the case of free undamped/damped vibration, considered in the absence/presence of the inerter in the mechanical system. Influence of inertance on the amplitude of vibration, phase angle, natural frequency, damping ratio, and logarithmic decrement was clarified. It was mainly found that the inerter decreases the natural frequency of the undamped system and also of the damped system if the damping ratio is below 0.707. On the other hand, the inerter increases the natural frequency of the damped system if the damping ratio exceeds 0.707. Results obtained in this work are useful for the adequate design of inerters.
Abstract: The objective of this article is to improve the passive vibration damping of solar array (SA) used in space structures, by the effective application of numerical optimization. A case study of a SA is used for demonstration. A finite element (FE) model was created and verified by experimental testing. Optimization was then conducted by implementing the FE model with the genetic algorithm, to find the optimal placement of aluminum circular patches, to suppress the first two bending mode shapes. The results were verified using experimental testing. Finally, a parametric study was conducted using the FE model where patch locations, material type, and shape were varied one at a time, and the results were compared with the optimal ones. The results clearly show that through the proper application of FE modeling and numerical optimization, passive vibration damping of space structures has been successfully achieved.
Abstract: One good analysis method in seismic response analysis is direct time integration, which widely adopts Rayleigh damping. An approach is presented for selection of Rayleigh damping coefficients to be used in seismic analyses to produce a response that is consistent with Modal damping response. In the presented approach, the expression of the error of peak response, acquired through complete quadratic combination method, and Rayleigh damping coefficients was set up and then the coefficients were produced by minimizing the error. Two finite element modes of soil layers, excited by 28 seismic waves, were used to demonstrate the feasibility and validity.
Abstract: This article deals with the analysis of active constrained layer damping (ACLD) of smart multiferroic or magneto-electro-elastic doubly curved shells. The kinematics of deformations of the multiferroic doubly curved shell is described by a layer-wise shear deformation theory. A three-dimensional finite element model of multiferroic shells has been developed taking into account the electro-elastic and magneto-elastic couplings. A simple velocity feedback control law is employed to incorporate the active damping. Influence of layer stacking sequence and boundary conditions on the response of the multiferroic doubly curved shell has been studied. In addition, for the different orientation of the fibers of the constraining layer, the performance of the ACLD treatment has been studied.
Abstract: This article presents a method of using the one
dimensional piezo-electric patch on beam model for structural
identification. A hybrid element constituted of one dimensional
beam element and a PZT sensor is used with reduced material
properties. This model is convenient and simple for identification
of beams. Accuracy of this element is first verified against a
corresponding 3D finite element model (FEM). The structural
identification is carried out as an inverse problem whereby
parameters are identified by minimizing the deviation between
the predicted and measured voltage response of the patch, when
subjected to excitation. A non-classical optimization algorithm
Particle Swarm Optimization is used to minimize this objective
function. The signals are polluted with 5% Gaussian noise to
simulate experimental noise. The proposed method is applied on
beam structure and identified parameters are stiffness and damping.
The model is also validated experimentally.
Abstract: In this paper, we discuss the propagation of sound in the narrow pathways of an occluded-ear simulator typically used for the measurement of insert-type earphones. The simulator has a standardized frequency response conforming to the international standard (IEC60318-4). In narrow pathways, the speed and phase of sound waves are modified by viscous air damping. In our previous paper, we proposed a new finite element method (FEM) to consider the effects of air viscosity in this type of audio equipment. In this study, we will compare the results from the ear simulator FEM model, and those from a three dimensional human ear canal FEM model made from computed tomography images, with the measured frequency response data from the ear canals of 18 people.
Abstract: It is known that stationary human occupants act as dynamic mass-spring-damper systems and can change the modal properties of civil engineering structures. This paper describes the full scale measurement to explain the tuned mass damper effects of stationary people on structural damping of footbridge with center span length of 33 m. A human body can be represented by a lumped system consisting of masses, springs, and dashpots. Complex eigenvalue calculation is also conducted by using ISO5982:1981 human model (two degree of freedom system). Based on experimental and analytical results for the footbridge with the stationary people in the standing position, it is demonstrated that stationary people behave as a tuned mass damper and that ISO5982:1981 human model can explain the structural damping characteristics measured in the field.
Abstract: During machining process, chatter is an unavoidable
phenomenon. Boring bars possess the cantilever shape and due to
this, it is subjected to chatter. The adverse effect of chatter includes
the increase in temperature which will leads to excess tool wear. To
overcome these problems, in this investigation, Cartridge brass (Cu –
70% and Zn – 30%) is passively fixed on the boring bar and also
clearance is provided in order to reduce the displacement, tool wear
and cutting temperature. A conventional all geared lathe is attached
with vibrometer and pyrometer is used to measure the displacement
and temperature. The influence of input parameters such as cutting
speed, depth of cut and clearance on temperature, tool wear and
displacement are investigated for various cutting conditions. From
the result, the optimum conditions to obtain better damping in boring
process for chatter reduction is identified.
Abstract: This paper deals with nonlinear vibration analysis
using finite element method for frame structures consisting of elastic
and viscoelastic damping layers supported by multiple nonlinear
concentrated springs with hysteresis damping. The frame is supported
by four nonlinear concentrated springs near the four corners. The
restoring forces of the springs have cubic non-linearity and linear
component of the nonlinear springs has complex quantity to represent
linear hysteresis damping. The damping layer of the frame structures
has complex modulus of elasticity. Further, the discretized equations in
physical coordinate are transformed into the nonlinear ordinary
coupled differential equations using normal coordinate corresponding
to linear natural modes. Comparing shares of strain energy of the
elastic frame, the damping layer and the springs, we evaluate the
influences of the damping couplings on the linear and nonlinear impact
responses. We also investigate influences of damping changed by
stiffness of the elastic frame on the nonlinear coupling in the damped
impact responses.
Abstract: A mathematical model of the additional effects of the
liquid in the hydrodynamic gap is presented in the paper. An
incompressible viscous fluid is considered. Based on computational
modeling are determined the matrices of mass, stiffness and damping.
The mathematical model is experimentally verified.
Abstract: The article presents two mathematical models of the
interaction between a rotating shaft and an incompressible fluid. The
mathematical model includes both the journal bearings and the
axially traversed hydrodynamic sealing gaps of hydraulic machines.
A method is shown for the identification of additional effects of the
fluid acting on the rotor of the machine, both for a linear and a nonlinear
model. The interaction is expressed by matrices of mass,
stiffness and damping.
Abstract: Today’s modern interconnected power system is
highly complex in nature. In this, one of the most important
requirements during the operation of the electric power system is the
reliability and security. Power and frequency oscillation damping
mechanism improve the reliability. Because of power system
stabilizer (PSS) low speed response against of major fault such as
three phase short circuit, FACTs devise that can control the network
condition in very fast time, are becoming popular. But FACTs
capability can be seen in a major fault present when nonlinear models
of FACTs devise and power system equipment are applied. To realize
this aim, the model of multi-machine power system with FACTs
controller is developed in MATLAB/SIMULINK using Sim Power
System (SPS) blockiest. Among the FACTs device, Static
synchronous series compensator (SSSC) due to high speed changes
its reactance characteristic inductive to capacitive, is effective power
flow controller. Tuning process of controller parameter can be
performed using different method. But Genetic Algorithm (GA)
ability tends to use it in controller parameter tuning process. In this
paper firstly POD controller is used to power oscillation damping.
But in this station, frequency oscillation dos not has proper damping
situation. So FOD controller that is tuned using GA is using that
cause to damp out frequency oscillation properly and power
oscillation damping has suitable situation.
Abstract: This paper present the experimental work of double
unit tunnel form building (TFB) subjected to in-plane lateral cyclic
loading. A one third scale of 3-storey double unit of TFB is tested
until its strength degradation. Then, the TFB is repaired and
retrofitted using additional shear wall, steel angle and CFRP sheet.
The crack patterns, lateral strength, stiffness, ductility and equivalent
viscous damping (EVD) were analyzed and compared before and
after repair and retrofit. The result indicates that the lateral strength
increases by 22% in pushing and 27% in pulling direction. Moreover,
the stiffness and ductility obtained before and after retrofit increase
tremendously by 87.87% and 39.66%, respectively. Meanwhile, the
energy absorption measured by equivalent viscous damping obtained
after retrofit increase by 12.34% in pulling direction. It can be
concluded that the proposed retrofit method is capable to increase the
lateral strength capacity, stiffness and energy absorption of double
unit TFB.