Abstract: Series compensators have been used for many years,
to increase the stability and load ability of transmission line. They
compensate retarded or advanced volt drop of transmission lines
by placing advanced or retarded voltage in series with them to
compensate the effective reactance, which cause to increase load
ability of transmission lines. In this paper, two method of fuzzy
controller, based on power reference tracking and impedance
reference tracking have been developed on TCSC controller in
order to increase load ability and improving power oscillation
damping of system. In these methods, fire angle of thyristors are
determined directly through the special Rule-bases with the error
and change of error as the inputs. The simulation results of two
area four- machines power system show the good performance of
power oscillation damping in system. Comparison of this method
with classical PI controller shows the increasing speed of system
response in power oscillation damping.
Abstract: In this paper, we study the oscillation of a class of second-order nonlinear neutral damped variable delay dynamic equations on time scales. By using a generalized Riccati transformation technique, we obtain some sufficient conditions for the oscillation of the equations. The results of this paper improve and extend some known results. We also illustrate our main results with some examples.
Abstract: This paper presents optimal based damping controllers of Unified Power Flow Controller (UPFC) for improving the damping power system oscillations. The design problem of UPFC damping controller and system configurations is formulated as an optimization with time domain-based objective function by means of Adaptive Tabu Search (ATS) technique. The UPFC is installed in Single Machine Infinite Bus (SMIB) for the performance analysis of the power system and simulated using MATLAB-s simulink. The simulation results of these studies showed that designed controller has an tremendous capability in damping power system oscillations.
Abstract: In order to upgrade the seismic resistibility of structures and enhance the functionality of an isolator, a new base isolator called the multiple trench friction pendulum system (MTFPS) is proposed in this study. The proposed MTFPS isolator is composed of a trench concave surface and several intermediate sliding plates in two orthogonal directions. Mathematical formulations have been derived to examine the characteristics of the proposed MTFPS isolator possessing multiple intermediate sliding plates. By means of mathematical formulations, it can be inferred that the natural period and damping effect of the MTFPS isolator with several intermediate sliding plates can be altered continually and controllably during earthquakes. Furthermore, results obtained from shaking table tests demonstrate that the proposed isolator provides good protection to structures for prevention of damage from strong earthquakes.
Abstract: In this paper, investigation of subsynchronous
resonance (SSR) characteristics of a hybrid series compensated
system and the design of voltage controller for three level 24-pulse
Voltage Source Converter based Static Synchronous Series
Compensator (SSSC) is presented. Hybrid compensation consists of
series fixed capacitor and SSSC which is a active series FACTS
controller. The design of voltage controller for SSSC is based on
damping torque analysis, and Genetic Algorithm (GA) is adopted for
tuning the controller parameters. The SSR Characteristics of SSSC
with constant reactive voltage control modes has been investigated.
The results show that the constant reactive voltage control of SSSC
has the effect of reducing the electrical resonance frequency, which
detunes the SSR.The analysis of SSR with SSSC is carried out based
on frequency domain method, eigenvalue analysis and transient
simulation. While the eigenvalue and damping torque analysis are
based on D-Q model of SSSC, the transient simulation considers both
D-Q and detailed three phase nonlinear system model using
switching functions.
Abstract: This paper describes dynamic analysis using proposed
fast finite element method for a shock absorbing structure including a
sponge. The structure is supported by nonlinear concentrated springs.
The restoring force of the spring has cubic nonlinearity and linear
hysteresis damping. To calculate damping properties for the structures
including elastic body and porous body, displacement vectors as
common unknown variable are solved under coupled condition. Under
small amplitude, we apply asymptotic method to complex eigenvalue
problem of this system to obtain modal parameters. And then
expressions of modal loss factor are derived approximately. This
approach was proposed by one of the authors previously. We call this
method as Modal Strain and Kinetic Energy Method (MSKE method).
Further, using the modal loss factors, the discretized equations in
physical coordinate are transformed into the nonlinear ordinary
coupled equations using normal coordinate corresponding to linear
natural modes. This transformation yields computation efficiency. As
a numerical example of a shock absorbing structures, we adopt double
skins with a sponge. The double skins are supported by nonlinear
concentrated springs. We clarify influences of amplitude of the input
force on nonlinear and chaotic responses.
Abstract: This paper describes vibration analysis using the finite
element method for a small earphone, especially for the diaphragm
shape with a low-rigidity. The viscoelastic diaphragm is supported by
multiple nonlinear concentrated springs with linear hysteresis
damping. The restoring forces of the nonlinear springs have cubic
nonlinearity. The finite elements for the nonlinear springs with
hysteresis are expressed and are connected to the diaphragm that is
modeled by linear solid finite elements in consideration of a complex
modulus of elasticity. Further, the discretized equations in physical
coordinates are transformed into the nonlinear ordinary coupled
equations using normal coordinates corresponding to the linear natural
modes. We computed the nonlinear stationary and non-stationary
responses due to the internal resonance between modes with large
amplitude in the nonlinear springs and elastic modes in the diaphragm.
The non-stationary motions are confirmed as the chaos due to the
maximum Lyapunov exponents with a positive number. From the time
histories of the deformation distribution in the chaotic vibration, we
identified nonlinear modal couplings.
Abstract: To compute dynamic characteristics of nonlinear viscoelastic springs with elastic structures having huge degree-of-freedom, Yamaguchi proposed a new fast numerical method using finite element method [1]-[2]. In this method, restoring forces of the springs are expressed using power series of their elongation. In the expression, nonlinear hysteresis damping is introduced. In this expression, nonlinear complex spring constants are introduced. Finite element for the nonlinear spring having complex coefficients is expressed and is connected to the elastic structures modeled by linear solid finite element. Further, to save computational time, the discrete equations in physical coordinate are transformed into the nonlinear ordinary coupled equations using normal coordinate corresponding to linear natural modes. In this report, the proposed method is applied to simulation for impact responses of a viscoelastic shock absorber with an elastic structure (an S-shaped structure) by colliding with a concentrated mass. The concentrated mass has initial velocities and collides with the shock absorber. Accelerations of the elastic structure and the concentrated mass are measured using Levitation Mass Method proposed by Fujii [3]. The calculated accelerations from the proposed FEM, corresponds to the experimental ones. Moreover, using this method, we also investigate dynamic errors of the S-shaped force transducer due to elastic mode in the S-shaped structure.
Abstract: The proper selection of the AC-side passive filter
interconnecting the voltage source converter to the power supply is
essential to obtain satisfactory performances of an active power filter
system. The use of the LCL-type filter has the advantage of
eliminating the high frequency switching harmonics in the current
injected into the power supply. This paper is mainly focused on
analyzing the influence of the interface filter parameters on the active
filtering performances. Some design aspects are pointed out. Thus,
the design of the AC interface filter starts from transfer functions by
imposing the filter performance which refers to the significant current
attenuation of the switching harmonics without affecting the
harmonics to be compensated. A Matlab/Simulink model of the entire
active filtering system including a concrete nonlinear load has been
developed to examine the system performances. It is shown that a
gamma LC filter could accomplish the attenuation requirement of the
current provided by converter. Moreover, the existence of an optimal
value of the grid-side inductance which minimizes the total harmonic
distortion factor of the power supply current is pointed out.
Nevertheless, a small converter-side inductance and a damping
resistance in series with the filter capacitance are absolutely needed
in order to keep the ripple and oscillations of the current at the
converter side within acceptable limits. The effect of change in the
LCL-filter parameters is evaluated. It is concluded that good active
filtering performances can be achieved with small values of the
capacitance and converter-side inductance.
Abstract: A seismic isolation pad produced by utilizing the scrap
tire rubber which contains interleaved steel reinforcing cords has been
proposed. The steel cords are expected to function similar to the steel
plates used in conventional laminated rubber bearings. The scrap tire
rubber pad (STRP) isolator is intended to be used in low rise
residential buildings of highly seismic areas of the developing
countries. Experimental investigation was conducted on unbonded
STRP isolators, and test results provided useful information including
stiffness, damping values and an eventual instability of the isolation
unit. Finite element analysis (FE analysis) of STRP isolator was
carried out on properly bonded samples. These types of isolators
provide positive incremental force resisting capacity up to shear strain
level of 155%. This paper briefly discusses the force deformation
behavior of bonded STRP isolators including stability of the isolation
unit.
Abstract: In this paper, genetic algorithm (GA) opmization technique is applied to design Flexible AC Transmission System (FACTS)-based damping controllers. Two types of controller structures, namely a proportional-integral (PI) and a lead-lag (LL) are considered. The design problem of the proposed controllers is formulated as an optimization problem and GA is employed to search for optimal controller parameters. By minimizing the time-domain based objective function, in which the deviation in the oscillatory rotor speed of the generator is involved; stability performance of the system is improved. The proposed controllers are tested on a weakly connected power system subjected to different disturbances. The non-linear simulation results are presented to show the effectiveness of the proposed controller and their ability to provide efficient damping of low frequency oscillations. It is also observed that the proposed SSSC-based controllers improve greatly the voltage profile of the system under severe disturbances. Further, the dynamic performances of both the PI and LL structured FACTS-controller are analyzed at different loading conditions and under various disturbance condition as well as under unbalanced fault conditions..
Abstract: This paper presents a systematic approach for
designing Static Synchronous Series Compensator (SSSC) based
supplementary damping controllers for damping low frequency
oscillations in a single-machine infinite-bus power system. The
design problem of the proposed controller is formulated as an
optimization problem and RCGA is employed to search for optimal
controller parameters. By minimizing the time-domain based
objective function, in which the deviation in the oscillatory rotor
speed of the generator is involved; stability performance of the
system is improved. Simulation results are presented and compared
with a conventional method of tuning the damping controller
parameters to show the effectiveness and robustness of the proposed
design approach.
Abstract: This paper presents Simulation and experimental
study aimed at investigating the effectiveness of an adaptive artificial
neural network stabilizer on enhancing the damping torque of a
synchronous generator. For this purpose, a power system comprising
a synchronous generator feeding a large power system through a
short tie line is considered. The proposed adaptive neuro-control
system consists of two multi-layered feed forward neural networks,
which work as a plant model identifier and a controller. It generates
supplementary control signals to be utilized by conventional
controllers. The details of the interfacing circuits, sensors and
transducers, which have been designed and built for use in tests, are
presented. The synchronous generator is tested to investigate the
effect of tuning a Power System Stabilizer (PSS) on its dynamic
stability. The obtained simulation and experimental results verify the
basic theoretical concepts.
Abstract: This paper investigates and compares performance of
various conventional and fuzzy logic based controllers at generator
locations for oscillation damping. Performance of combination of
conventional and fuzzy logic based controllers also studied by
comparing overshoot on the active power deviation response for a
small disturbance and damping ratio of the critical mode. Fuzzy logic
based controllers can not be modeled in the state space form to get
the eigenvalues and corresponding damping ratios of various modes
of generators and controllers. Hence, a new method based on tracing
envelop of time domain waveform is also presented and used in the
paper for comparing performance of controllers. The paper also
shows that if the fuzzy based controllers designed separately
combining them could not lead to a better performance.
Abstract: Design of a fixed parameter robust STATCOM controller for a multi-machine power system through an H-? based loop-shaping procedure is presented. The trial and error part of the graphical loop-shaping procedure has been eliminated by embedding a particle swarm optimization (PSO) technique in the design loop. Robust controllers were designed considering the detailed dynamics of the multi-machine system and results were compared with reduced order models. The robust strategy employing loop-shaping and PSO algorithms was observed to provide very good damping profile for a wide range of operation and for various disturbance conditions.
Abstract: Dynamic characteristics of a four-lobe journal bearing
of micropolar fluids are presented. Lubricating oil containing
additives and contaminants is modelled as micropolar fluid. The
modified Reynolds equation is obtained using the micropolar
lubrication theory and solving it by using finite difference technique.
The dynamic characteristics in terms of stiffness, damping
coefficients, the critical mass and whirl ratio are determined for
various values of size of material characteristic length and the
coupling number. The results show compared with Newtonian fluids,
that micropolar fluid exhibits better stability.
Abstract: Fast delay estimation methods, as opposed to
simulation techniques, are needed for incremental performance
driven layout synthesis. On-chip inductive effects are becoming
predominant in deep submicron interconnects due to increasing clock
speed and circuit complexity. Inductance causes noise in signal
waveforms, which can adversely affect the performance of the circuit
and signal integrity. Several approaches have been put forward which
consider the inductance for on-chip interconnect modelling. But for
even much higher frequency, of the order of few GHz, the shunt
dielectric lossy component has become comparable to that of other
electrical parameters for high speed VLSI design. In order to cope up
with this effect, on-chip interconnect has to be modelled as
distributed RLCG line. Elmore delay based methods, although
efficient, cannot accurately estimate the delay for RLCG interconnect
line. In this paper, an accurate analytical delay model has been
derived, based on first and second moments of RLCG
interconnection lines. The proposed model considers both the effect
of inductance and conductance matrices. We have performed the
simulation in 0.18μm technology node and an error of as low as less
as 5% has been achieved with the proposed model when compared to
SPICE. The importance of the conductance matrices in interconnect
modelling has also been discussed and it is shown that if G is
neglected for interconnect line modelling, then it will result an delay
error of as high as 6% when compared to SPICE.