Abstract: In this paper, we demonstrated a 1 × 4 silicon photonic cascaded arrayed waveguide grating, which is fabricated on a SOI wafer with a 220 nm top Si layer and a 2µm buried oxide layer. The measured on-chip transmission loss of this cascaded arrayed waveguide grating is ~ 5.6 dB, including the fiber-to-waveguide coupling loss. The adjacent crosstalk is 33.2 dB. Compared to the normal single silicon photonic arrayed waveguide grating with a crosstalk of ~ 12.5 dB, the crosstalk of this device has been dramatically increased.
Abstract: This paper presents the experimental results of 11 kV
and 33 kV silicon composite insulators under artificial salt and urea
polluted conditions. The tests were carried out under different
seasons like summer, winter, and monsoon. The artificial pollution is
prepared by properly dissolving the salt and urea in the water. The
prepared salt and urea pollutions are sprayed on the insulators and
dried up for sufficiently large time. The process is continued until a
uniform layer is formed on the surface of insulator. For each insulator
rating, four samples were tested. The maximum leakage current and
breakdown voltage were measured. From experimental data,
performance of test specimen is evaluated by comparing breakdown
voltage and leakage current during different seasons when exposed to
salt and urea polluted conditions. From these results the performance
of the insulators can be predicted when they are installed in
industrial, agricultural, and coastal areas. The experimental tests were
carried out in the High Voltage laboratory using two stage cascade
transformer having the rating of 1000 kVA, 500 kV.
Abstract: Cochlear Implantation (CI) which became a routine
procedure for the last decades is an electronic device that provides a
sense of sound for patients who are severely and profoundly deaf.
The optimal success of this implantation depends on the electrode
technology and deep insertion techniques. However, this manual
insertion procedure may cause mechanical trauma which can lead to
severe destruction of the delicate intracochlear structure.
Accordingly, future improvement of the cochlear electrode implant
insertion needs reduction of the excessive force application during
the cochlear implantation which causes tissue damage and trauma.
This study is examined tool-tissue interaction of large prototype scale
digit embedded with distributive tactile sensor based upon cochlear
electrode and large prototype scale cochlea phantom for simulating
the human cochlear which could lead to small scale digit
requirements. The digit, distributive tactile sensors embedded with
silicon-substrate was inserted into the cochlea phantom to measure
any digit/phantom interaction and position of the digit in order to
minimize tissue and trauma damage during the electrode cochlear
insertion. The digit have provided tactile information from the digitphantom
insertion interaction such as contact status, tip penetration,
obstacles, relative shape and location, contact orientation and
multiple contacts. The tests demonstrated that even devices of such a
relative simple design with low cost have potential to improve
cochlear implant surgery and other lumen mapping applications by
providing tactile sensory feedback information and thus controlling
the insertion through sensing and control of the tip of the implant
during the insertion. In that approach, the surgeon could minimize the
tissue damage and potential damage to the delicate structures within
the cochlear caused by current manual electrode insertion of the
cochlear implantation. This approach also can be applied to other
minimally invasive surgery applications as well as diagnosis and path
navigation procedures.
Abstract: This paper sets out a behavioral macro-model of a
Merged PiN and Schottky (MPS) diode based on silicon carbide
(SiC). This model holds good for both static and dynamic electrothermal
simulations for industrial applications. Its parameters have
been worked out from datasheets curves by drawing on the
optimization method: Simulated Annealing (SA) for the SiC MPS
diodes made available in the industry. The model also adopts the
Analog Behavioral Model (ABM) of PSPICE in which it has been
implemented. The thermal behavior of the devices was also taken
into consideration by making use of Foster’ canonical network as
figured out from electro-thermal measurement provided by the
manufacturer of the device.
Abstract: The photovoltaic and the semiconductor industries are
in growth and it is necessary to supply a large amount of silicon to
maintain this growth. Since silicon is still the best material for the
manufacturing of solar cells and semiconductor components so the
pure silicon like solar grade and semiconductor grade materials are
demanded. There are two main routes for silicon production:
metallurgical and chemical. In this article, we reviewed the
electrotecnological installations and systems for semiconductor
manufacturing. The main task is to design the installation which can
produce SOG Silicon from river sand by one work unit.
Abstract: The laser-ultrasonic method is realized for
quantifying the influence of porosity on the local Young’s
modulus of isotropic composite materials. The method is based on
a laser thermooptical method of ultrasound generation combined
with measurement of the phase velocity of longitudinal and shear
acoustic waves in samples. The main advantage of this method
compared with traditional ultrasonic research methods is the
efficient generation of short and powerful probing acoustic pulses
required for reliable testing of ultrasound absorbing and
scattering heterogeneous materials. Using as an example samples
of a metal matrix composite with reinforcing microparticles of
silicon carbide in various concentrations, it is shown that to
provide an effective increase in Young’s modulus with increasing
concentration of microparticles, the porosity of the final sample
should not exceed 2%.
Abstract: Processing of high-silicon bauxite on the base of the
traditional clinkering method is related to high power consumption
and capital investments, which makes production of alumina from
those ores non-competitive in terms of basic economic showings. For
these reasons, development of technological solutions enabling to
process bauxites with various chemical and mineralogical structures
efficiently with low level of thermal power consumption is important.
Flow sheet of the studies on washability of ores from the Timanskoe
and the Severo-Onezhskoe deposits is on the base of the flotation
method.
Abstract: Calcium Phosphate Cement (CPC) due to its high bioactivity and optimum bioresorbability shows excellent bone regeneration capability. Despite it has limited applications as bone implant due to its macro-porous microstructure causing its poor mechanical strength. The reinforcement of apatitic CPCs with biocompatible fibre glass phase is an attractive area of research to improve upon its mechanical strength. Here, we study the setting behaviour of Si-doped and un-doped α tri calcium phosphate (α - TCP) based CPC and its reinforcement with addition of E-glass fibre. Alpha Tri calcium phosphate powders were prepared by solid state sintering of CaCO3 , CaHPO4 and Tetra Ethyl Ortho Silicate (TEOS) was used as silicon source to synthesize Si doped α-TCP powders. Both initial and final setting time of the developed cement was delayed because of Si addition. Crystalline phases of HA (JCPDS 9- 432), α-TCP (JCPDS 29-359) and β-TCP (JCPDS 9-169) were detected in the X-ray diffraction (XRD) pattern after immersion of CPC in simulated body fluid (SBF) for 0 hours to 10 days. As Si incorporation in the crystal lattice stabilized the TCP phase, Si doped CPC showed little slower rate of conversion into HA phase as compared to un-doped CPC. The SEM image of the microstructure of hardened CPC showed lower grain size of HA in un-doped CPC because of premature setting and faster hydrolysis of un-doped CPC in SBF as compared that in Si-doped CPC. Premature setting caused generation of micro and macro porosity in un-doped CPC structure which resulted in its lower mechanical strength as compared to that in Si-doped CPC. It was found that addition of 10 wt% of E-glass fibre into Si-doped α-TCP increased the average DTS of CPC from 8 MPa to 15 MPa as the fibres could resists the propagation of crack by deflecting the crack tip. Our study shows that biocompatible E-glass fibre in optimum proportion in CPC matrix can enhance the mechanical strength of CPC without affecting its biocompatibility.
Abstract: A new design of aerostatic thrust bearing is proposed
for high static stiffness. The bearing body, which is mead of polymer
covered with metallic membrane, is held by a circular ring. Such a
support helps form a concave air gap to grasp the air pressure. The
polymer body, which can be made rapidly by either injection or
molding is able to provide extra damping under dynamic loading. The
smooth membrane not only serves as the bearing surface but also
protects the polymer body. The restrictor is a capillary inside a silicone
tube. It can passively compensate the variation of load by expanding
the capillary diameter for more air flux. In the present example, the
stiffness soars from 15.85 N/μm of typical bearing to 349.85 N/μm at
bearing elevation 9.5 μm; meanwhile the load capacity also enhances
from 346.86 N to 704.18 N.
Abstract: As the Silicon oxide scaled down in MOSFET
technology to few nanometers, gate Direct Tunneling (DT) in
Floating gate (FGMOSFET) devices has become a major concern for
analog designers. FGMOSFET has been used in many low-voltage
and low-power applications, however, there is no accurate model that
account for DT gate leakage in nano-scale. This paper studied and
analyzed different simulation models for FGMOSFET using TSMC
90-nm technology. The simulation results for FGMOSFET cascade
current mirror shows the impact of DT on circuit performance in
terms of current and voltage without the need for fabrication. This
works shows the significance of using an accurate model for
FGMOSFET in nan-scale technologies.
Abstract: This paper presents thermal annealing de-wetting
technique for the preparation of porous metal membrane for Thin
Film Encapsulation (TFE) application. Thermal annealing de-wetting
experimental results reveal that pore size formation in porous metal
membrane depend upon i.e. 1. The substrate at which metal is
deposited, 2. Melting point of metal used for porous metal cap layer
membrane formation, 3. Thickness of metal used for cap layer, 4.
Temperature used for formation of porous metal membrane. In order
to demonstrate this technique, Silver (Ag) was used as a metal for
preparation of porous metal membrane on amorphous silicon (a-Si)
and silicon oxide. The annealing of the silver thin film of various
thicknesses was performed at different temperature. Pores in porous
silver film were analyzed using Scanning Electron Microscope
(SEM). In order to check the usefulness of porous metal film for TFE
application, the porous silver film prepared on amorphous silicon (a-
Si) and silicon oxide was released using XeF2 and VHF, respectively.
Finally, guide line and structures are suggested to use this porous
membrane for robust TFE application.
Abstract: In this paper, we proposed a novel SCR (Silicon Controlled
Rectifier) - based ESD (Electrostatic Discharge) protection device for I/O
and power clamp. The proposed device has a higher holding voltage
characteristic than conventional SCR. These characteristics enable to have
latch-up immunity under normal operating conditions as well as superior full
chip ESD protection. The proposed device was analyzed to figure out
electrical characteristics and tolerance robustness in term of individual
design parameters (D1, D2, D3). They are investigated by using the
Synopsys TCAD simulator. As a result of simulation, holding voltage
increased with different design parameters. The holding voltage of the
proposed device changes from 3.3V to 7.9V. Also, N-Stack structure ESD
device with the high holding voltage is proposed. In the simulation results,
2-stack has holding voltage of 6.8V and 3-stack has holding voltage of
10.5V. The simulation results show that holding voltage of stacking
structure can be larger than the operation voltage of high-voltage
application.
Abstract: To explore how the brain may recognise objects in its
general,accurate and energy-efficient manner, this paper proposes the
use of a neuromorphic hardware system formed from a Dynamic
Video Sensor (DVS) silicon retina in concert with the SpiNNaker
real-time Spiking Neural Network (SNN) simulator. As a first step
in the exploration on this platform a recognition system for dynamic
hand postures is developed, enabling the study of the methods used
in the visual pathways of the brain. Inspired by the behaviours of
the primary visual cortex, Convolutional Neural Networks (CNNs)
are modelled using both linear perceptrons and spiking Leaky
Integrate-and-Fire (LIF) neurons.
In this study’s largest configuration using these approaches, a
network of 74,210 neurons and 15,216,512 synapses is created and
operated in real-time using 290 SpiNNaker processor cores in parallel
and with 93.0% accuracy. A smaller network using only 1/10th of the
resources is also created, again operating in real-time, and it is able
to recognise the postures with an accuracy of around 86.4% - only
6.6% lower than the much larger system. The recognition rate of the
smaller network developed on this neuromorphic system is sufficient
for a successful hand posture recognition system, and demonstrates
a much improved cost to performance trade-off in its approach.
Abstract: Aluminium matrix composites with alumina
reinforcements give superior mechanical & physical properties. Their
applications in several fields like automobile, aerospace, defense,
sports, electronics, bio-medical and other industrial purposes are
becoming essential for the last several decades. In the present work,
fabrication of hybrid composite was done by Stir casting technique
using Al 6061 as a matrix with alumina and silicon carbide (SiC) as
reinforcement materials. The weight percentage of alumina is varied
from 2 to 4% and the silicon carbide weight percentage is maintained
constant at 2%. Hardness and wear tests are performed in the as cast
and heat treated conditions. Age hardening treatment was performed
on the specimen with solutionizing at 550°C, aging at two
temperatures (150 and 200°C) for different time durations. Hardness
distribution curves are drawn and peak hardness values are recorded.
Hardness increase was very sensitive with respect to the decrease in
aging temperature. There was an improvement in wear resistance of
the peak aged material when aged at lower temperature. Also
increase in weight percent of alumina, increases wear resistance at
lower temperature but opposite behavior was seen when aged at
higher temperature.
Abstract: The nanoindentation behaviour and phase
transformation of annealed single-crystal silicon wafers are examined.
The silicon specimens are annealed at temperatures of 250, 350 and
450ºC, respectively, for 15 minutes and are then indented to maximum
loads of 30, 50 and 70 mN. The phase changes induced in the indented
specimens are observed using transmission electron microscopy
(TEM) and micro-Raman scattering spectroscopy (RSS). For all
annealing temperatures, an elbow feature is observed in the unloading
curve following indentation to a maximum load of 30 mN. Under
higher loads of 50 mN and 70 mN, respectively, the elbow feature is
replaced by a pop-out event. The elbow feature reveals a complete
amorphous phase transformation within the indented zone, whereas
the pop-out event indicates the formation of Si XII and Si III phases.
The experimental results show that the formation of these crystalline
silicon phases increases with an increasing annealing temperature and
indentation load. The hardness and Young’s modulus both decrease as
the annealing temperature and indentation load are increased.
Abstract: This paper deals with the study of reflection and
transmission characteristics of acoustic waves at the interface of a
semiconductor half-space and elastic solid. The amplitude ratios
(reflection and transmission coefficients) of reflected and transmitted
waves to that of incident wave varying with the incident angles have
been examined for the case of quasi-longitudinal wave. The special
cases of normal and grazing incidence have also been derived with
the help of Gauss elimination method. The mathematical model
consisting of governing partial differential equations of motion and
charge carriers’ diffusion of n-type semiconductors and elastic solid
has been solved both analytically and numerically in the study. The
numerical computations of reflection and transmission coefficients
has been carried out by using MATLAB programming software for
silicon (Si) semiconductor and copper elastic solid. The computer
simulated results have been plotted graphically for Si
semiconductors. The study may be useful in semiconductors,
geology, and seismology in addition to surface acoustic wave (SAW)
devices.
Abstract: Al6061 alloy base matrix, reinforced with particles of
silicon carbide (10 wt %) and Graphite powder (1wt%), known as
hybrid composites have been fabricated by liquid metallurgy route
(stir casting technique) and optimized at different parameters like
applied load, sliding speed and sliding distance by taguchi method. A
plan of experiment generated through taguchi technique was used to
perform experiments based on L27 orthogonal array. The developed
ANOVA and regression equations are used to find the optimum
coefficient of friction and wear under the influence of applied load,
sliding speed and sliding distance. On the basis of “smaller the best”
the dry sliding wear resistance was analysed and finally confirmation
tests were carried out to verify the experimental results.
Abstract: The article presents a plasma chemical technology for
processing solid fuels, using examples of bituminous and brown
coals. Thermodynamic and experimental investigation of the
technology was made. The technology allows producing synthesis
gas from the coal organic mass and valuable components (technical
silicon, ferrosilicon, aluminum, and carbon silicon, as well as
microelements of rare metals, such as uranium, molybdenum,
vanadium, etc.) from the mineral mass. The thusly produced highcalorific
synthesis gas can be used for synthesis of methanol, as a
high-calorific reducing gas instead of blast-furnace coke as well as
power gas for thermal power plants.
Abstract: Coal fly ash is formed as a solid waste product from
the combustion of coal in coal fired power stations. Huge amounts of
fly ash are produced globally every year and are predicted to
increase. Nowadays, less than half of the fly ash is used as a raw
material for cement manufacturing, construction and the rest of it is
disposed as a waste causing yet another environmental concern. For
this reason, the recycling of this kind of slurries into useful materials
is quite important in terms of economical and environmental aspects.
The purpose of this study is to evaluate the Orhaneli and
Tuncbilek coal fly ashes for utilization in some industrial
applications. Therefore the mineralogical and chemical compositions
of these fly ashes were analyzed by X-ray fluorescence spectroscopy,
ourier-transform infrared spectrometer, and X-ray diffraction. The
silicon (Si) and aluminum (Al) in the fly ashes were activated by
alkali fusion technique with sodium hydroxide. The obtained extracts
were analyzed for Si and Al content by inductively coupled plasma
optical emission spectrometry.
Abstract: Early diagnosis of infection like Hep-B virus in blood
is important for low cost medical treatment. For this purpose, it is
desirable to develop a point of care device which should be able to
detect trace quantities of the target molecule in blood. In this paper,
we report a nanoporous silicon oxide sensor which is capable of
detecting down to 1fM concentration of Hep-B surface antigen in
blood without the requirement of any centrifuge or pre-concentration.
This has been made possible by the presence of resonant peak in the
sensitivity characteristics. This peak is observed to be dependent only
on the concentration of the specific antigen and not on the interfering
species in blood serum. The occurrence of opposite impedance
change within the pores and at the bottom of the pore is responsible
for this effect. An electronic interface has also been designed to
provide a display of the virus concentration.