Abstract: This paper addresses the design of hospital Intensive
Care Unit windows for the achievement of visual comfort and energy
savings. The aim was to identify the window size and shading system
configurations that could fulfill daylighting adequacy, avoid glare
and reduce energy consumption. The study focused on addressing the
effect of utilizing different shading systems in association with a
range of Window-to-Wall Ratios (WWR) in different orientations
under the desert clear-sky of Cairo, Egypt.
The results of this study demonstrated that solar penetration is a
critical concern affecting the design of ICU windows in desert
locations, as in Cairo, Egypt. Use of shading systems was found to be
essential in providing acceptable daylight performance and energy
saving. Careful positioning of the ICU window towards a proper
orientation can dramatically improve performance. It was observed
that ICU windows facing the north direction enjoyed the widest range
of successful window configuration possibilities at different WWRs.
ICU windows facing south enjoyed a reasonable number of
configuration options as well. By contrast, the ICU windows facing
the east orientation had a very limited number of options that provide
acceptable performance. These require additional local shading
measures at certain times due to glare incidence. Moreover, use of
horizontal sun breakers and solar screens to protect the ICU windows
proved to be more successful than the other alternatives in a wide
range of Window to Wall Ratios. By contrast, the use of light shelves
and vertical shading devices seemed questionable.
Abstract: This paper is concerned with knowledge representation
and extraction of fuzzy if-then rules using Interval Type-2
Context-based Fuzzy C-Means clustering (IT2-CFCM) with the aid of
fuzzy granulation. This proposed clustering algorithm is based on
information granulation in the form of IT2 based Fuzzy C-Means
(IT2-FCM) clustering and estimates the cluster centers by preserving
the homogeneity between the clustered patterns from the IT2 contexts
produced in the output space. Furthermore, we can obtain the
automatic knowledge representation in the design of Radial Basis
Function Networks (RBFN), Linguistic Model (LM), and Adaptive
Neuro-Fuzzy Networks (ANFN) from the numerical input-output data
pairs. We shall focus on a design of ANFN in this paper. The
experimental results on an estimation problem of energy performance
reveal that the proposed method showed a good knowledge
representation and performance in comparison with the previous
works.
Abstract: The building sector is responsible, in many
industrialized countries, for about 40% of the total energy
requirements, so it seems necessary to devote some efforts in this
area in order to achieve a significant reduction of energy
consumption and of greenhouse gases emissions.
The paper presents a study aiming at providing a design
methodology able to identify the best configuration of the system
building/plant, from a technical, economic and environmentally point
of view.
Normally, the classical approach involves a building's energy
loads analysis under steady state conditions, and subsequent selection
of measures aimed at improving the energy performance, based on
previous experience made by architects and engineers in the design
team. Instead, the proposed approach uses a sequence of two wellknown
scientifically validated calculation methods (TRNSYS and
RETScreen), that allow quite a detailed feasibility analysis.
To assess the validity of the calculation model, an existing,
historical building in Central Italy, that will be the object of
restoration and preservative redevelopment, was selected as a casestudy.
The building is made of a basement and three floors, with a
total floor area of about 3,000 square meters.
The first step has been the determination of the heating and
cooling energy loads of the building in a dynamic regime by means,
which allows simulating the real energy needs of the building in
function of its use. Traditional methodologies, based as they are on
steady-state conditions, cannot faithfully reproduce the effects of
varying climatic conditions and of inertial properties of the structure.
With this model is possible to obtain quite accurate and reliable
results that allow identifying effective combinations building-HVAC
system.
The second step has consisted of using output data obtained as
input to the calculation model, which enables to compare different
system configurations from the energy, environmental and financial
point of view, with an analysis of investment, and operation and
maintenance costs, so allowing determining the economic benefit of
possible interventions.
The classical methodology often leads to the choice of
conventional plant systems, while our calculation model provides a
financial-economic assessment for innovative energy systems and
low environmental impact.
Computational analysis can help in the design phase, particularly
in the case of complex structures with centralized plant systems, by
comparing the data returned by the calculation model for different
design options.
Abstract: With an increase in the interest in the energy conservation for buildings, and the emergence of many methods and easily-understandable approaches to it, energy conservation has now become the public’s main interest, as compared to in the past when it was only focused upon by experts. This study aims to help the occupants of a building to understand the energy efficiency and consumption of the building by providing them information on the building’s energy efficiency through a mobile application. The energy performance assessment models are proposed on the basis of the actual energy usage and building characteristics such as the architectural scheme and the building equipment. The university buildings in Korea are used as a case to demonstrate the mobile application.
Abstract: Careful design and selection of daylighting systems can greatly help in reducing not only artificial lighting use, but also decrease cooling energy consumption and, therefore, potential for downsizing air-conditioning systems. This paper aims to evaluate the energy performance of two types of top-light daylighting systems due to the integration of daylight together with artificial lighting in an existing examinaton hall in University Kebangsaan Malaysia, based on a hot and humid climate. Computer simulation models have been created for building case study (base case) and the two types of toplight daylighting designs for building energy performance evaluation using the VisualDOE 4.0 building energy simulation program. The finding revealed that daylighting through top-light systems is a very beneficial design strategy in reducing annual lighting energy consumption and the overall total annual energy consumption.
Abstract: Because nodes are usually battery-powered, the energy
presents a very scarce resource in wireless sensor networks. For this
reason, the design of medium access control had to take energy
efficiency as one of its hottest concerns. Accordingly, in order to
improve the energy performance of MAC schemes in wireless sensor
networks, several ways can be followed. In fact, some researchers try
to limit idle listening while others focus on mitigating overhearing
(i.e. a node can hear a packet which is destined to another node)
or reducing the number of the used control packets. We, in this
paper, propose a new hybrid MAC protocol termed ELE-MAC
(i.e. Energy Latency Efficient MAC). The ELE-MAC major design
goals are energy and latency efficiencies. It adopts less control
packets than SMAC in order to preserve energy. We carried out ns-
2 simulations to evaluate the performance of the proposed protocol.
Thus, our simulation-s results prove the ELE-MAC energy efficiency.
Additionally, our solution performs statistically the same or better
latency characteristic compared to adaptive SMAC.
Abstract: In this paper, the energy performance of a selected
UHDE Ammonia plant is optimized by conducting heat integration through waste heat recovery and the synthesis of a heat exchange
network (HEN). Minimum hot and cold utility requirements were estimated through IChemE spreadsheet. Supporting simulation was
carried out using HYSYS software. The results showed that there is
no need for heating utility while the required cold utility was found to
be around 268,714 kW. Hence a threshold pinch case was faced. Then, the hot and cold streams were matched appropriately. Also,
waste heat recovered resulted with savings in HP and LP steams of
approximately 51.0% and 99.6%, respectively. An economic analysis
on proposed HEN showed very attractive overall payback period not
exceeding 3 years. In general, a net saving approaching 35% was
achieved in implementing heat optimization of current studied UHDE Ammonia process.
Abstract: Solar shading designs are important for reduction of building energy consumption and improvement of indoor thermal environment. This paper carried out a number of building simulations for evaluation of the energy performance of different shading devices based on incremental costs. The results show that movable shading devices lower incremental costs by up to 50% compared with fixed ones for the same building energy efficiency for residential buildings, and wing panel shadings are much more suitable in commercial buildings than baring screen ones and overhangs for commercial buildings.
Abstract: The work presented in this study is related to an
energy system analysis based on passive cooling system for
dwellings. It consists to solar chimney energy performances
determination versus geometrical and environmental considerations
as the size and inlet width conditions of the chimney. Adrar site
located in the southern region of Algeria is chosen for this study
according to ambient temperature and solar irradiance technical data
availability. Obtained results are related to the glazing temperature
distributions, the chimney air flow and internal wall temperatures.
The air room change per hour (ACH) parameter, the outlet air
velocity and mass air flow rate are also determined. It is shown that
the chimney width has a significant effect on energy performances
compared to its entry size. A good agreement is observed between
these results and those obtained by others from the literature.
Abstract: A multiple-option analytical model for the evaluation of the energy performance and distribution of aerodynamic forces acting on a vertical-axis Darrieus wind turbine depending on both rotor architecture and operating conditions is presented. For this purpose, a numerical algorithm, capable of generating the desired rotor conformation depending on design geometric parameters, is coupled to a Single/Double-Disk Multiple-Streamtube Blade Element – Momentum code. Both single and double-disk configurations are analyzed and model predictions are compared to literature experimental data in order to test the capability of the code for predicting rotor performance. Effective airfoil characteristics based on local blade Reynolds number are obtained through interpolation of literature low-Reynolds airfoil databases. Some corrections are introduced inside the original model with the aim of simulating also the effects of blade dynamic stall, rotor streamtube expansion and blade finite aspect ratio, for which a new empirical relationship to better fit the experimental data is proposed. In order to predict also open field rotor operation, a freestream wind shear profile is implemented, reproducing the effect of atmospheric boundary layer.
Abstract: This paper presents a model for the evaluation of
energy performance and aerodynamic forces acting on a three-bladed
small vertical axis Darrieus wind turbine depending on blade chord
curvature with respect to rotor axis.
The adopted survey methodology is based on an analytical code
coupled to a solid modeling software, capable of generating the
desired blade geometry depending on the blade design geometric
parameters, which is linked to a finite volume CFD code for the
calculation of rotor performance.
After describing and validating the model with experimental data,
the results of numerical simulations are proposed on the bases of two
different blade profile architectures, which are respectively
characterized by a straight chord and by a curved one, having a chord
radius equal to rotor external circumference. A CFD campaign of
analysis is completed for three blade-candidate airfoil sections, that is
the recently-developed DU 06-W-200 cambered blade profile, a
classical symmetrical NACA 0021 and its derived cambered airfoil,
characterized by a curved chord, having a chord radius equal to rotor
external circumference.
The effects of blade chord curvature on angle of attack, blade
tangential and normal forces are first investigated and then the
overall rotor torque and power are analyzed as a function of blade
azimuthal position, achieving a numerical quantification of the
influence of blade camber on overall rotor performance.
Abstract: As the data-driven economy is growing faster than
ever and the demand for energy is being spurred, we are facing
unprecedented challenges of improving energy efficiency in data
centers. Effectively maximizing energy efficiency or minimising the
cooling energy demand is becoming pervasive for data centers. This
paper investigates overall energy consumption and the energy
efficiency of cooling system for a data center in Finland as a case
study. The power, cooling and energy consumption characteristics
and operation condition of facilities are examined and analysed.
Potential energy and cooling saving opportunities are identified and
further suggestions for improving the performance of cooling system
are put forward. Results are presented as a comprehensive evaluation
of both the energy performance and good practices of energy
efficient cooling operations for the data center. Utilization of an
energy recovery concept for cooling system is proposed. The
conclusion we can draw is that even though the analysed data center
demonstrated relatively high energy efficiency, based on its power
usage effectiveness value, there is still a significant potential for
energy saving from its cooling systems.
Abstract: This paper presents a model for the evaluation of
energy performance and aerodynamic forces acting on a small
straight-bladed Darrieus-type vertical axis wind turbine depending on
blade geometrical section. It consists of an analytical code coupled to
a solid modeling software, capable of generating the desired blade
geometry based on the desired blade design geometric parameters.
Such module is then linked to a finite volume commercial CFD code
for the calculation of rotor performance by integration of the
aerodynamic forces along the perimeter of each blade for a full period
of revolution.After describing and validating the computational
model with experimental data, the results of numerical simulations
are proposed on the bases of two candidate airfoil sections, that is a
classical symmetrical NACA 0021 blade profile and the recently
developed DU 06-W-200 non-symmetric and laminar blade
profile.Through a full CFD campaign of analysis, the effects of blade
geometrical section on angle of attack are first investigated and then
the overall rotor torque and power are analyzed as a function of blade
azimuthal position, achieving a numerical quantification of the
influence of airfoil geometry on overall rotor performance.
Abstract: To investigate the energy performance of solar shading devices, this paper carried out a survey on the current status of solar shading utilization in buildings in Ningbo and performed building simulations to evaluate the energy savings potential by adopting different solar shading devices. Results show that solar shading utilization in this area is not popular and effective, and should be considered firstly in the design stage since the potential for energy savings is up to 6.8% for residential buildings and 9.4% for commercial buildings.