Abstract: Architects commonly attempt a depiction of organic forms when their works are inspired by nature, regardless of the building site. Nevertheless it is also possible to try matching structures with natural scenery, by applying a phenomenological approach in terms of spatial operations, regarding perceptions from nature through architectural aspects such as protection, views, and orientation. This method acknowledges a relationship between place and space, where intentions towards tangible facts then become design statements. Although spaces resulting from such a process may present an effective response to the environment, they can also offer further outcomes beyond the realm of form. The hypothesis is that, in addition to recognising a bond between architecture and nature, it is also plausible to associate such perceptions with the inner ambient of buildings, by analysing features such as daylight. The case study of a single-family house in a rainforest near Valdivia, Chilean Patagonia is presented, with the intention of addressing the above notions through a discussion of the actual effects of inhabiting a place by way of a series of insights, including a revision of diagrams and photographs that assist in understanding the implications of this design practice. In addition, figures based on post-occupancy behaviour and daylighting performance relate both architectural and environmental issues to a decision-making process motivated by the observation of nature.
Abstract: In this paper, an attempt has been made to analyze the effect of wall window orientation on Daylight Illuminance Ratio (DIR) and energy saving in a building known as “SODHA BERS COMPLEX (SBC)” at Varanasi, UP, India. The building has been designed incorporating all passive concepts for thermal comfort as well daylighting concepts to maximize the use of natural daylighting for the occupants in the day to day activities. The annual average DIR and the energy saving has been estimated by using the DIR model for wall window with different orientations under clear sky condition. It has been found that for south oriented window the energy saving per square meter is more compared to the other orientations due to the higher level of solar insolation for the south window in northern hemisphere whereas energy saving potential is minimum for north oriented wall window. The energy saving potential was 26%, 81% and 51% higher for east, south and west oriented window in comparison to north oriented window. The average annual DIR has same trends of variation as the annual energy saving and it is maximum for south oriented window and minimum for north oriented window.
Abstract: Result from the constant dwindle in natural resources,
the alternative way to reduce the costs in our daily life would be urgent
to be found in the near future. As the ancient technique based on the
theory of solar chimney since roman times, the double-skin façade are
simply composed of two large glass panels in purpose of daylighting
and also natural ventilation in the daytime. Double-skin façade is
generally installed on the exterior side of buildings as function as the
window, so there is always a huge amount of passive solar energy the
façade would receive to induce the airflow every sunny day. Therefore,
this article imposes a domestic double-skin window for residential
usage and attempts to improve the volume flow rate inside the cavity
between the panels by the frame geometry design, the installation of
outlet guide plate and the solar energy collection system. Note that the
numerical analyses are applied to investigate the characteristics of flow
field, and the boundary conditions in the simulation are totally based
on the practical experiment of the original prototype. Then we
redesign the prototype from the knowledge of the numerical results
and fluid dynamic theory, and later the experiments of modified
prototype will be conducted to verify the simulation results. The
velocities at the inlet of each case are increase by 5%, 45% and 15%
from the experimental data, and also the numerical simulation results
reported 20% improvement in volume flow rate both for the frame
geometry design and installation of outlet guide plate.
Abstract: This paper presents the results of a study on the
influence of varying percentages of rock bridges along a basal surface
defining a biplanar failure mode. A pseudo-coupled-hydromechanical
brittle fracture analysis is adopted using the state-of-the-art code
Slope Model. Model results show that rock bridge failure is strongly
influenced by the incorporation of groundwater pressures. The
models show that groundwater pressure can promote total failure of a
5% rock bridge along the basal surface. Once the percentage of the
rock bridges increases to 10 and 15%, although, the rock bridges are
broken, full interconnection of the surface defining the basal surface
of the biplanar mode does not occur. Increased damage is caused
when the rock bridge is located at the daylighting end of the basal
surface in proximity to the blast damage zone. As expected, some
cracking damage is experienced in the blast damage zone, where
properties representing a good quality controlled damage blast
technique were assumed. Model results indicate the potential increase
of permeability towards the blast damage zone.
Abstract: This paper addresses the design of hospital Intensive
Care Unit windows for the achievement of visual comfort and energy
savings. The aim was to identify the window size and shading system
configurations that could fulfill daylighting adequacy, avoid glare
and reduce energy consumption. The study focused on addressing the
effect of utilizing different shading systems in association with a
range of Window-to-Wall Ratios (WWR) in different orientations
under the desert clear-sky of Cairo, Egypt.
The results of this study demonstrated that solar penetration is a
critical concern affecting the design of ICU windows in desert
locations, as in Cairo, Egypt. Use of shading systems was found to be
essential in providing acceptable daylight performance and energy
saving. Careful positioning of the ICU window towards a proper
orientation can dramatically improve performance. It was observed
that ICU windows facing the north direction enjoyed the widest range
of successful window configuration possibilities at different WWRs.
ICU windows facing south enjoyed a reasonable number of
configuration options as well. By contrast, the ICU windows facing
the east orientation had a very limited number of options that provide
acceptable performance. These require additional local shading
measures at certain times due to glare incidence. Moreover, use of
horizontal sun breakers and solar screens to protect the ICU windows
proved to be more successful than the other alternatives in a wide
range of Window to Wall Ratios. By contrast, the use of light shelves
and vertical shading devices seemed questionable.
Abstract: Hospitals, everywhere, are considered heavy energy consumers. Hospital Intensive Care Unit spaces pose a special challenge, where design guidelines requires the provision of external windows for daylighting and external view. Window protection strategies could be employed to reduce energy loads without detriment effect on comfort or health care. This paper addresses the effectiveness of using various window strategies on the annual cooling, heating and lighting energy use of a typical Hospital Intensive Unit space. Series of experiments were performed using the EnergyPlus simulation software for a typical Intensive Care Unit (ICU) space in Cairo, located in the Egyptian desert. This study concluded that the use of shading systems is more effective in conserving energy in comparison with glazing of different types, in the Cairo ICUs. The highest energy savings in the West and South orientations were accomplished by external perforated solar screens, followed by overhangs positioned at a protection angle of 45°.
Abstract: Careful design and selection of daylighting systems can greatly help in reducing not only artificial lighting use, but also decrease cooling energy consumption and, therefore, potential for downsizing air-conditioning systems. This paper aims to evaluate the energy performance of two types of top-light daylighting systems due to the integration of daylight together with artificial lighting in an existing examinaton hall in University Kebangsaan Malaysia, based on a hot and humid climate. Computer simulation models have been created for building case study (base case) and the two types of toplight daylighting designs for building energy performance evaluation using the VisualDOE 4.0 building energy simulation program. The finding revealed that daylighting through top-light systems is a very beneficial design strategy in reducing annual lighting energy consumption and the overall total annual energy consumption.
Abstract: The renewable energy has been attracting attention as
a new alternative energy due to the problem of environmental
pollution and resource depletion. In particular, daylighting and PV
system are regarded as the solutions. In this paper, the hybrid
dimming control system supplied by solar cell and daylighting
system was designed. Daylighting system is main source and PV
system is spare source. PV system operates the LED lamp which
supports daylighting system because daylighting system is unstable
due to the variation of irradiance. In addition, PV system has a role
charging batteries. Battery charging has a benefit that PV system
operate LED lamp in the bad weather. However, LED lamp always
can`t turn on that-s why dimming control system was designed. In
particular, the solar charging robot was designed to check the
interior irradiance intensity. These systems and the application of
the solar charging robot are expected to contribute developing
alternative energy in the near future.
Abstract: A lightpipe is an about 99 percent specular reflective
mirror pipe or duct that is used for the transmission of the daylight
from the outside into a building. The lightpipes are usually used in
the daylighting buildings, in the residential, industrial and
commercial sectors. This paper is about the performances of a
lightpipe installed in a laboratory (3 m x 2.6 m x 3 m) without
windows. The aim is to analyse the luminous intensity distribution
for several sky/sun conditions. The lightpipe was monitored during
the year 2006. The lightpipe is 1 m long and the diameter of the top
collector and of the internal diffuser device is 0.25 m. In the
laboratory there are seven illuminance sensors: one external is
located on the roof of the laboratory and six internal sensors are
connected to a data acquisition system. The internal sensors are
positioned under the internal diffusive device at an height of 0.85 m
from the floor to simulate a working plane. The numerical data are
obtained through a simulation software. This paper shows the
comparison between the experimental and numerical results
concerning the behavior of the lightpipe.
Abstract: This paper investigated the impact of ceiling height and window head heights variation on daylighting inside architectural teaching studio with a full width window. In architectural education, using the studio is more than normal classroom in most credit hours. Therefore, window position, size and dimension of studio have direct influence on level of daylighting. Daylighting design is a critical factor that improves student learning, concentration and behavior, in addition to these, it also reduces energy consumption. The methodology of analysis involves using Radiance in IES software under overcast and cloudy sky in Malaysia. It has been established that presentation of daylighting of architecture studio can be enhanced by changing the ceiling heights and window level, because, different ceiling heights and window head heights can contribute to different range of daylight levels.
Abstract: The use of solar control film on windows as one of
solar passive strategies for building have becoming important and is
gaining recognition. Malaysia located close to equator is having
warm humid climate with long sunshine hours and abundant solar
radiation throughout the year. Hence, befitting solar control on
windows is absolutely necessary to capture the daylight whilst
moderating thermal impact and eliminating glare problems. This is
one of the energy efficient strategies to achieve thermal and visual
comfort in buildings. Therefore, this study was carried out to
investigate the effect of window solar controls on thermal and visual
performance of naturally ventilated buildings. This was conducted via
field data monitoring using a test building facility. Four types of
window glazing systems were used with three types of solar control
films. Data were analysed for thermal and visual impact with
reference to thermal and optical characteristics of the films. Results
show that for each glazing system, the surface temperature of
windows are influenced by the Solar Energy Absorption property, the
indoor air temperature are influenced by the Solar Energy
Transmittance and Solar Energy Reflectance, and the daylighting by
Visible Light Transmission and Shading Coefficient. Further
investigations are underway to determine the mathematical relation
between thermal energy and visual performance with the thermal and
optical characteristics of solar control films.
Abstract: In recent years, there has been an increasing interest in using daylight to save energy in buildings. In tropical regions, daylighting is always an energy saver. On the other hand, daylight provides visual comfort. According to standards, it shows that many criteria should be taken into consideration in order to have daylight utilization and visual comfort. The current standard in Malaysia, MS 1525 does not provide sufficient guideline. Hence, more research is needed on daylight performance. If architects do not consider daylight design, it not only causes inconvenience in working spaces but also causes more energy consumption as well as environmental pollution. This research had surveyed daylight performance in 5 selected office buildings from different area of Malaysian through experimental method. Several parameters of daylight quality such as daylight factor, surface luminance and surface luminance ratio were measured in different rooms in each building. The result of this research demonstrated that most of the buildings were not designed for daylight utilization. Therefore, it is very important that architects follow the daylight design recommendation to reduce consumption of electric power for artificial lighting while the sufficient quality of daylight is available.