Abstract: Thermal performance is considered to be a key measure in building sustainability. One of the technologies used in the current building sustainable design is the rooftop solar PV power generators. The application of this type of technology has expanded vastly during the last five years in many countries. This paper studies the effect of roof shading developed by the solar PV panels on dwellings’ thermal performance. The analysis in this work is performed by using two types of packages: “AccuRate Sustainability” for rating the energy efficiency of residential building design, and “PVSYST” for the solar PV power system design. The former package is used to calculate the annual heating and cooling load, and the later package is used to evaluate the power production from the roof top PV system. The analysis correlates the electrical energy generated from the PV panels to the change in the heating and cooling load due to roof shading. Different roof orientation, roof inclination, roof insulation, as well as PV panel area are considered in this study. The analysis shows that the drop in energy efficiency due to the shaded area of the roof by PV panels is negligible compared to the energy generated by these panels.
Abstract: This paper addresses the design of hospital Intensive
Care Unit windows for the achievement of visual comfort and energy
savings. The aim was to identify the window size and shading system
configurations that could fulfill daylighting adequacy, avoid glare
and reduce energy consumption. The study focused on addressing the
effect of utilizing different shading systems in association with a
range of Window-to-Wall Ratios (WWR) in different orientations
under the desert clear-sky of Cairo, Egypt.
The results of this study demonstrated that solar penetration is a
critical concern affecting the design of ICU windows in desert
locations, as in Cairo, Egypt. Use of shading systems was found to be
essential in providing acceptable daylight performance and energy
saving. Careful positioning of the ICU window towards a proper
orientation can dramatically improve performance. It was observed
that ICU windows facing the north direction enjoyed the widest range
of successful window configuration possibilities at different WWRs.
ICU windows facing south enjoyed a reasonable number of
configuration options as well. By contrast, the ICU windows facing
the east orientation had a very limited number of options that provide
acceptable performance. These require additional local shading
measures at certain times due to glare incidence. Moreover, use of
horizontal sun breakers and solar screens to protect the ICU windows
proved to be more successful than the other alternatives in a wide
range of Window to Wall Ratios. By contrast, the use of light shelves
and vertical shading devices seemed questionable.
Abstract: Hospitals, everywhere, are considered heavy energy consumers. Hospital Intensive Care Unit spaces pose a special challenge, where design guidelines requires the provision of external windows for daylighting and external view. Window protection strategies could be employed to reduce energy loads without detriment effect on comfort or health care. This paper addresses the effectiveness of using various window strategies on the annual cooling, heating and lighting energy use of a typical Hospital Intensive Unit space. Series of experiments were performed using the EnergyPlus simulation software for a typical Intensive Care Unit (ICU) space in Cairo, located in the Egyptian desert. This study concluded that the use of shading systems is more effective in conserving energy in comparison with glazing of different types, in the Cairo ICUs. The highest energy savings in the West and South orientations were accomplished by external perforated solar screens, followed by overhangs positioned at a protection angle of 45°.
Abstract: The goal of the study reported in the paper was to
determine whether Ambient Occlusion Shading (AOS) has a significant effect on users' perception of American Sign Language (ASL) finger spelling animations. Seventy-one (71) subjects
participated in the study; all subjects were fluent in ASL. The participants were asked to watch forty (40) sign language animation
clips representing twenty (20) finger spelled words. Twenty (20) clips did not show ambient occlusion, whereas the other twenty (20) were
rendered using ambient occlusion shading. After viewing each animation, subjects were asked to type the word being finger-spelled and rate its legibility. Findings show that the presence of AOS had a significant effect on the subjects perception of the signed words.
Subjects were able to recognize the animated words rendered with AOS with higher level of accuracy, and the legibility ratings of the animations showing AOS were consistently higher across subjects.