Abstract: This paper aims to give a full study of the dynamic
behavior of a mono-phase active power filter. First, the principle of
the parallel active power filter will be introduced. Then, a
dimensioning procedure for all its components will be explained in
detail, such as the input filter, the current and voltage controllers.
This active power filter is simulated using OrCAD program showing
the validity of the theoretical study.
Abstract: This paper introduces application of multi degree of freedom fuzzy(MDOFF) controller in permanent magnet (PM)drive system. The drive system model is developed for FO control. Simulation of the system is carried out to predict the performance at NL and under load,. The results indicate that application of MDOFF controller is effective for sensorless PM drive system.
Abstract: A novel nanofinishing process using improved ball
end magnetorheological (MR) finishing tool was developed for finishing of flat as well as 3D surfaces of ferromagnetic and non ferromagnetic workpieces. In this process a magnetically controlled
ball end of smart MR polishing fluid is generated at the tip surface of
the tool which is used as a finishing medium and it is guided to
follow the surface to be finished through computer controlled 3-axes
motion controller. The experiments were performed on ferromagnetic
workpiece surface in the developed MR finishing setup to study the effect of finishing time on final surface roughness. The performance
of present finishing process on final finished surface roughness was studied. The surface morphology was observed under scanning
electron microscopy and atomic force microscope. The final surface finish was obtained as low as 19.7 nm from the initial surface
roughness of 142.9 nm. The outcome of newly developed finishing process can be found useful in its applications in aerospace,
automotive, dies and molds manufacturing industries, semiconductor and optics machining etc.
Abstract: ELS is an important ground based hardware in the
loop simulator used for aerodynamics torque loading experiments
of the actuators under test. This work focuses on improvement of the
transient response of torque controller with parameters uncertainty
of Electrical Load Simulator (ELS).The parameters of load simulator
are estimated online and the model is updated, eliminating the model
error and improving the steady state torque tracking response of
torque controller. To improve the Transient control performance the
gain of robust term of SMC is updated online using fuzzy logic
system based on the amount of uncertainty in parameters of load
simulator. The states of load simulator which cannot be measured
directly are estimated using luenberger observer with update of new
estimated parameters. The stability of the control scheme is verified
using Lyapunov theorem. The validity of proposed control scheme is
verified using simulations.
Abstract: In this paper the reference current for Voltage Source
Converter (VSC) of the Shunt Active Power Filter (SAPF) is
generated using Synchronous Reference Frame method,
incorporating the PI controller with anti-windup scheme. The
proposed method improves the harmonic filtering by compensating
the winding up phenomenon caused by the integral term of the PI
controller.
Using Reference Frame Transformation, the current is transformed
from om a - b - c stationery frame to rotating 0 - d - q frame. Using
the PI controller, the current in the 0 - d - q frame is controlled to
get the desired reference signal. A controller with integral action
combined with an actuator that becomes saturated can give some
undesirable effects. If the control error is so large that the integrator
saturates the actuator, the feedback path becomes ineffective because
the actuator will remain saturated even if the process output changes.
The integrator being an unstable system may then integrate to a very
large value, the phenomenon known as integrator windup.
Implementing the integrator anti-windup circuit turns off the
integrator action when the actuator saturates, hence improving the
performance of the SAPF and dynamically compensating harmonics
in the power network. In this paper the system performance is
examined with Shunt Active Power Filter simulation model.
Abstract: In this paper, we propose an architecture for easily
constructing a robot controller. The architecture is a multi-agent
system which has eight agents: the Man-machine interface, Task
planner, Task teaching editor, Motion planner, Arm controller,
Vehicle controller, Vision system and CG display. The controller has
three databases: the Task knowledge database, the Robot database and
the Environment database. Based on this controller architecture, we
are constructing an experimental power distribution line maintenance
robot system and are doing the experiment for the maintenance tasks,
for example, “Bolt insertion task".
Abstract: Most high-performance ac drives utilize a current
controller. The controller switches a voltage source inverter (VSI)
such that the motor current follows a set of reference current
waveforms. Fixed-band hysteresis (FBH) current control has been
widely used for the PWM inverter. We want to apply the same
controller for the PWM AC chopper. The aims of the controller is to
optimize the harmonic content at both input and output sides, while
maintaining acceptable losses in the ac chopper and to control in
wide range the fundamental output voltage. Fixed band controller has
been simulated and analyzed for a single-phase AC chopper and are
easily extended to three-phase systems. Simulation confirmed the
advantages and the excellent performance of the modulation method
applied for the AC chopper.
Abstract: This paper presents a Particle Swarm Optimization
(PSO) method for determining the optimal parameters of a first-order
controller for TCP/AQM system. The model TCP/AQM is described
by a second-order system with time delay. First, the analytical
approach, based on the D-decomposition method and Lemma of
Kharitonov, is used to determine the stabilizing regions of a firstorder
controller. Second, the optimal parameters of the controller are
obtained by the PSO algorithm. Finally, the proposed method is
implemented in the Network Simulator NS-2 and compared with the
PI controller.
Abstract: A self tuning PID control strategy using reinforcement
learning is proposed in this paper to deal with the control of wind
energy conversion systems (WECS). Actor-Critic learning is used to
tune PID parameters in an adaptive way by taking advantage of the
model-free and on-line learning properties of reinforcement learning
effectively. In order to reduce the demand of storage space and to
improve the learning efficiency, a single RBF neural network is used
to approximate the policy function of Actor and the value function of
Critic simultaneously. The inputs of RBF network are the system
error, as well as the first and the second-order differences of error.
The Actor can realize the mapping from the system state to PID
parameters, while the Critic evaluates the outputs of the Actor and
produces TD error. Based on TD error performance index and
gradient descent method, the updating rules of RBF kernel function
and network weights were given. Simulation results show that the
proposed controller is efficient for WECS and it is perfectly
adaptable and strongly robust, which is better than that of a
conventional PID controller.
Abstract: Vehicle which are turning or maneuvering at high speeds
are susceptible to sliding and subsequently deviate from desired path. In
this paper the dynamics governing the Yaw/Roll behavior of a vehicle
has been simulated. Two different simulations have been used one for
the real vehicle, for which a fuzzy controller is designed to increase its
directional stability property. The other simulation is for a hypothetical
vehicle with much higher tire cornering stiffness which is capable of
developing the required lateral forces at the tire-ground patch contact to
attain the desired lateral acceleration for the vehicle to follow the
desired path without slippage. This simulation model is our reference
model.
The logic for keeping the vehicle on the desired track in the cornering
or maneuvering state is to have some braking forces on the inner or
outer tires based on the direction of vehicle deviation from the desired
path. The inputs to our vehicle simulation model is steer angle δ and
vehicle velocity V , and the outputs can be any kinematical parameters
like yaw rate, yaw acceleration, side slip angle, rate of side slip angle
and so on. The proposed fuzzy controller is a feed forward controller.
This controller has two inputs which are steer angle δ and vehicle
velocity V, and the output of the controller is the correcting moment M,
which guides the vehicle back to the desired track. To develop the
membership functions for the controller inputs and output and the fuzzy
rules, the vehicle simulation has been run for 1000 times and the
correcting moment have been determined by trial and error. Results of
the vehicle simulation with fuzzy controller are very promising
and show the vehicle performance is enhanced greatly over the
vehicle without the controller. In fact the vehicle performance
with the controller is very near the performance of the reference
ideal model.
Abstract: In this paper we have proposed a methodology to
develop an amperometric biosensor for the analysis of glucose
concentration using a simple microcontroller based data acquisition
system. The work involves the development of Detachable
Membrane Unit (enzyme based biomembrane) with immobilized
glucose oxidase on the membrane and interfacing the same to the
signal conditioning system. The current generated by the biosensor
for different glucose concentrations was signal conditioned, then
acquired and computed by a simple AT89C51-microcontroller. The
optimum operating parameters for the better performance were found
and reported. The detailed performance evaluation of the biosensor
has been carried out. The proposed microcontroller based biosensor
system has the sensitivity of 0.04V/g/dl, with a resolution of
50mg/dl. It has exhibited very good inter day stability observed up to
30 days. Comparing to the reference method such as HPLC, the
accuracy of the proposed biosensor system is well within ± 1.5%.
The system can be used for real time analysis of glucose
concentration in the field such as, food and fermentation and clinical
(In-Vitro) applications.
Abstract: In this paper, investigation of subsynchronous
resonance (SSR) characteristics of a hybrid series compensated
system and the design of voltage controller for three level 24-pulse
Voltage Source Converter based Static Synchronous Series
Compensator (SSSC) is presented. Hybrid compensation consists of
series fixed capacitor and SSSC which is a active series FACTS
controller. The design of voltage controller for SSSC is based on
damping torque analysis, and Genetic Algorithm (GA) is adopted for
tuning the controller parameters. The SSR Characteristics of SSSC
with constant reactive voltage control modes has been investigated.
The results show that the constant reactive voltage control of SSSC
has the effect of reducing the electrical resonance frequency, which
detunes the SSR.The analysis of SSR with SSSC is carried out based
on frequency domain method, eigenvalue analysis and transient
simulation. While the eigenvalue and damping torque analysis are
based on D-Q model of SSSC, the transient simulation considers both
D-Q and detailed three phase nonlinear system model using
switching functions.
Abstract: This paper discusses coordinated reactive power -
voltage (Q-V) control in a multi machine steam power plant. The
drawbacks of manual Q-V control are briefly listed, and the design
requirements for coordinated Q-V controller are specified.
Theoretical background and mathematical model of the new
controller are presented next followed by validation of developed
Matlab/Simulink model through comparison with recorded
responses in real steam power plant and description of practical
realisation of the controller. Finally, the performance of
commissioned controller is illustrated on several examples of
coordinated Q-V control in real steam power plant and compared
with manual control.
Abstract: This paper presents a systematic procedure for modelling and simulation of a power system installed with a power system stabilizer (PSS) and a flexible ac transmission system (FACTS)-based controller. For the design purpose, the model of example power system which is a single-machine infinite-bus power system installed with the proposed controllers is developed in MATLAB/SIMULINK. In the developed model synchronous generator is represented by model 1.1. which includes both the generator main field winding and the damper winding in q-axis so as to evaluate the impact of PSS and FACTS-based controller on power system stability. The model can be can be used for teaching the power system stability phenomena, and also for research works especially to develop generator controllers using advanced technologies. Further, to avoid adverse interactions, PSS and FACTS-based controller are simultaneously designed employing genetic algorithm (GA). The non-linear simulation results are presented for the example power system under various disturbance conditions to validate the effectiveness of the proposed modelling and simultaneous design approach.
Abstract: Dual motor drives fed by single inverter is
purposely designed to reduced size and cost with respect to
single motor drives fed by single inverter. Previous researches
on dual motor drives only focus on the modulation and the
averaging techniques. Only a few of them, study the
performance of the drives based on different speed controller
other than Proportional and Integrator (PI) controller. This
paper presents a detailed comparative study on fuzzy rule-base
in Fuzzy Logic speed Controller (FLC) for Dual Permanent
Magnet Synchronous Motor (PMSM) drives. Two fuzzy speed
controllers which are standard and simplified fuzzy speed
controllers are designed and the results are compared and
evaluated. The standard fuzzy controller consists of 49 rules
while the proposed controller consists of 9 rules determined by
selecting the most dominant rules only. Both designs are
compared for wide range of speed and the robustness of both
controllers over load disturbance changes is tested to
demonstrate the effectiveness of the simplified/reduced rulebase.
Abstract: This paper proposes a Fuzzy Sliding Mode Control (FSMC) as a control strategy for Buck-Boost DC-DC converter. The proposed fuzzy controller specifies changes in the control signal based on the knowledge of the surface and the surface change to satisfy the sliding mode stability and attraction conditions. The performances of the proposed fuzzy sliding controller are compared to those obtained by a classical sliding mode controller. The satisfactory simulation results show the efficiency of the proposed control law which reduces the chattering phenomenon. Moreover, the obtained results prove the robustness of the proposed control law against variation of the load resistance and the input voltage of the studied converter.
Abstract: Saccharomyces cerevisiae (baker-s yeast) can exhibit
sustained oscillations during the operation in a continuous bioreactor
that adversely affects its stability and productivity. Because of
heterogeneous nature of cell populations, the cell population balance
models can be used to capture the dynamic behavior of such cultures.
In this paper an unstructured, segregated model is used which is
based on population balance equation(PBE) and then in order to
simulation, the 4th order Rung-Kutta is used for time dimension and
three methods, finite difference, orthogonal collocation on finite
elements and Galerkin finite element are used for discretization of the
cell mass domain. The results indicate that the orthogonal collocation
on finite element not only is able to predict the oscillating behavior of
the cell culture but also needs much little time for calculations.
Therefore this method is preferred in comparison with other methods.
In the next step two controllers, a globally linearizing control (GLC)
and a conventional proportional-integral (PI) controller are designed
for controlling the total cell mass per unit volume, and performances
of these controllers are compared through simulation. The results
show that although the PI controller has simpler structure, the GLC
has better performance.
Abstract: In the control theory one attempts to find a controller
that provides the best possible performance with respect to some
given measures of performance. There are many sorts of controllers
e.g. a typical PID controller, LQR controller, Fuzzy controller etc. In
the paper will be introduced polynomial controller with novel tuning
method which is based on the special pole placement encoding
scheme and optimization by Genetic Algorithms (GA). The examples
will show the performance of the novel designed polynomial
controller with comparison to common PID controller.
Abstract: Due to their high power-to-weight ratio and low cost, pneumatic actuators are attractive for robotics and automation applications; however, achieving fast and accurate control of their position have been known as a complex control problem. The paper presents a methodology for obtaining controllers that achieve high position accuracy and preserve the closed-loop characteristics over a broad operating range. Experimentation with a number of conventional (or "classical") three-term controllers shows that, as repeated operations accumulate, the characteristics of the pneumatic actuator change requiring frequent re-tuning of the controller parameters (PID gains). Furthermore, three-term controllers are found to perform poorly in recovering the closed-loop system after the application of load or other external disturbances. The key reason for these problems lies in the non-linear exchange of energy inside the cylinder relating, in particular, to the complex friction forces that develop on the piston-wall interface. In order to overcome this problem but still remain within the boundaries of classical control methods, we designed an auto selective classicaql controller so that the system performance would benefit from all three control gains (KP, Kd, Ki) according to system requirements and the characteristics of each type of controller. This challenging experimentation took place for consistent performance in the face of modelling imprecision and disturbances. In the work presented, a selective PID controller is presented for an experimental rig comprising an air cylinder driven by a variable-opening pneumatic valve and equipped with position and pressure sensors. The paper reports on tests carried out to investigate the capability of this specific controller to achieve consistent control performance under, repeated operations and other changes in operating conditions.
Abstract: This paper presents Simulation and experimental
study aimed at investigating the effectiveness of an adaptive artificial
neural network stabilizer on enhancing the damping torque of a
synchronous generator. For this purpose, a power system comprising
a synchronous generator feeding a large power system through a
short tie line is considered. The proposed adaptive neuro-control
system consists of two multi-layered feed forward neural networks,
which work as a plant model identifier and a controller. It generates
supplementary control signals to be utilized by conventional
controllers. The details of the interfacing circuits, sensors and
transducers, which have been designed and built for use in tests, are
presented. The synchronous generator is tested to investigate the
effect of tuning a Power System Stabilizer (PSS) on its dynamic
stability. The obtained simulation and experimental results verify the
basic theoretical concepts.