Abstract: In this paper, an approach for the liver tumor detection
in computed tomography (CT) images is represented. The detection
process is based on classifying the features of target liver cell to
either tumor or non-tumor. Fractional differential (FD) is applied for
enhancement of Liver CT images, with the aim of enhancing texture
and edge features. Later on, a fusion method is applied to merge
between the various enhanced images and produce a variety of
feature improvement, which will increase the accuracy of
classification. Each image is divided into NxN non-overlapping
blocks, to extract the desired features. Support vector machines
(SVM) classifier is trained later on a supplied dataset different from
the tested one. Finally, the block cells are identified whether they are
classified as tumor or not. Our approach is validated on a group of
patients’ CT liver tumor datasets. The experiment results
demonstrated the efficiency of detection in the proposed technique.
Abstract: One of the most important challenging factors in
medical images is nominated as noise. Image denoising refers to the
improvement of a digital medical image that has been infected by
Additive White Gaussian Noise (AWGN). The digital medical image
or video can be affected by different types of noises. They are
impulse noise, Poisson noise and AWGN. Computed tomography
(CT) images are subjects to low quality due to the noise. Quality of
CT images is dependent on absorbed dose to patients directly in such
a way that increase in absorbed radiation, consequently absorbed
dose to patients (ADP), enhances the CT images quality. In this
manner, noise reduction techniques on purpose of images quality
enhancement exposing no excess radiation to patients is one the
challenging problems for CT images processing. In this work, noise
reduction in CT images was performed using two different
directional 2 dimensional (2D) transformations; i.e., Curvelet and
Contourlet and Discrete Wavelet Transform (DWT) thresholding
methods of BayesShrink and AdaptShrink, compared to each other
and we proposed a new threshold in wavelet domain for not only
noise reduction but also edge retaining, consequently the proposed
method retains the modified coefficients significantly that result good
visual quality. Data evaluations were accomplished by using two
criterions; namely, peak signal to noise ratio (PSNR) and Structure
similarity (Ssim).
Abstract: Studying stress and strain trends in the femur and
recognizing femur failure mechanism is very important for
preventing hip fracture in the elderly. The aim of this study was to
identify high stress and strain regions in the femur during normal
walking and falling to find the mechanical behavior and failure
mechanism of the femur. We developed a finite element model of the
femur from the subject’s quantitative computed tomography (QCT)
image and used it to identify potentially high stress and strain regions
during the single-leg stance and the sideways fall. It was found that
fracture may initiate from the superior region of femoral neck and
propagate to the inferior region during a high impact force such as
sideways fall. The results of this study showed that the femur bone is
more sensitive to strain than stress which indicates the effect of
strain, in addition to effect of stress, should be considered for failure
analysis.
Abstract: The aim of this study is to evaluate the effects of the
laser and partial vibration stimulation on the mice tibia with
morphological characteristics. Twenty female C57BL/6 mice (12
weeks old) were used for the experiment. The study was carried out on
four groups of animals each consisting of five mice. Four groups of
mice were ovariectomized. Animals were scanned at 0 and 2 weeks
after ovariectomy by using micro computed tomography to estimate
morphological characteristics of tibial trabecular bone. Morphological
analysis showed that structural parameters of multi-stimuli group
appear significantly better phase in BV/TV, BS/BV, Tb.Th, Tb.N,
Tb.Sp, and Tb.pf than single stimulation groups. However, single
stimulation groups didn’t show significant effect on tibia with Sham
group. This study suggests that multi-stimuli may restrain the change
as the degenerate phase on osteoporosis in the mice tibia.
Abstract: The purpose of this study was to reduce patient
waiting times, improve system throughput and improve resources
utilization in radiology department. A discrete event simulation
model was developed using Arena simulation software to investigate
different alternatives to improve the overall system delivery based on
adding resource scenarios due to the linkage between patient waiting
times and resource availability. The study revealed that there is no
addition investment need to procure additional scanner but hospital
management deploy managerial tactics to enhance machine
utilization and reduce the long waiting time in the department.
Abstract: Metallic foams have good potential for lightweight
structures for impact and blast mitigation. Therefore it is important to
find out the optimized foam structure (i.e. cell size, shape, relative
density, and distribution) to maximise energy absorption. In this
paper, quasistatic compression and microstructural characterization
of closed-cell aluminium foams of different pore size and cell
distributions have been carried out. We present results for two
different aluminium metal foams of density 0.49-0.51 g/cc and 0.31-
0.34 g/cc respectively that have been tested in quasi-static
compression. The influence of cell geometry and cell topology on
quasistatic compression behaviour has been investigated using optical
microscope and computed tomography (micro-CT) analysis. It is
shown that the deformation is not uniform in the structure and
collapse begins at the weakest point.
Abstract: Medical imaging technology has experienced a
dramatic change in the last few years. Medical imaging refers to the
techniques and processes used to create images of the human body
(or parts thereof) for various clinical purposes such as medical
procedures and diagnosis or medical science including the study of
normal anatomy and function. With the growth of computers and
image technology, medical imaging has greatly influenced the
medical field. The diagnosis of a health problem is now highly
dependent on the quality and the credibility of the image analysis.
This paper deals with the various aspects and types of medical
imaging.
Abstract: An accurate study of blood flow is associated with an accurate vascular pattern and geometrical properties of the organ of interest. Due to the complexity of vascular networks and poor accessibility in vivo, it is challenging to reconstruct the entire vasculature of any organ experimentally. The objective of this study is to introduce an innovative approach for the reconstruction of a full vascular tree from available morphometric data. Our method consists of implementing morphometric data on those parts of the vascular tree that are smaller than the resolution of medical imaging methods. This technique reconstructs the entire arterial tree down to the capillaries. Vessels greater than 2 mm are obtained from direct volume and surface analysis using contrast enhanced computed tomography (CT). Vessels smaller than 2mm are reconstructed from available morphometric and distensibility data and rearranged by applying Murray’s Laws. Implementation of morphometric data to reconstruct the branching pattern and applying Murray’s Laws to every vessel bifurcation simultaneously, lead to an accurate vascular tree reconstruction. The reconstruction algorithm generates full arterial tree topography down to the first capillary bifurcation. Geometry of each order of the vascular tree is generated separately to minimize the construction and simulation time. The node-to-node connectivity along with the diameter and length of every vessel segment is established and order numbers, according to the diameter-defined Strahler system, are assigned. During the simulation, we used the averaged flow rate for each order to predict the pressure drop and once the pressure drop is predicted, the flow rate is corrected to match the computed pressure drop for each vessel. The final results for 3 cardiac cycles is presented and compared to the clinical data.
Abstract: The objective of this paper is to develop a computational model of human nasal cavity from computed tomography (CT) scans using MIMICS software. Computational fluid dynamic techniques were employed to understand nasal airflow. Gambit and Fluent software was used to perform CFD simulation. Velocity profiles, iteration plots, pressure distribution, streamline and pathline patterns for steady, laminar airflow inside the human nasal cavity of healthy and also infected persons are presented in detail. The implications for olfaction are visualized. Results are validated with the available numerical and experimental data. The graphs reveal that airflow varies with different anatomical nasal structures and only fraction of the inspired air reaches the olfactory region. The Deviations in the results suggest that the treatment of infected volunteers will improve the olfactory function.
Abstract: In this paper problem of edge detection in digital images is considered. Edge detection based on morphological operators was applied on two sets (brain & chest) ct images. Three methods of edge detection by applying line morphological filters with multi structures in different directions have been used. 3x3 filter for first method, 5x5 filter for second method, and 7x7 filter for third method. We had applied this algorithm on (13 images) under MATLAB program environment. In order to evaluate the performance of the above mentioned edge detection algorithms, standard deviation (SD) and peak signal to noise ratio (PSNR) were used for justification for all different ct images. The objective method and the comparison of different methods of edge detection, shows that high values of both standard deviation and PSNR values of edge detection images were obtained.
Abstract: In this study, we present a new and fast algorithm for lung segmentation using CTA images. This process is quite important especially at lung vessel segmentation, detection of pulmonary emboly, finding nodules or segmentation of airways. Applied method has been carried out at four steps. At first step, images have been applied optimal threshold. At the second one, the subsegment vessels, which have a place in lung region and which are in small dimension, have been removed. At the third one, identifying and segmentation of lungs and airway edges have been carried out. Lastly, by throwing away the airway, lung segmentation has been presented.
Abstract: In this study three commercial semiconductor devices
were characterized in the laboratory for computed tomography
dosimetry: one photodiode and two phototransistors. It was evaluated
four responses to the irradiation: dose linearity, energy dependence,
angular dependence and loss of sensitivity after X ray exposure. The
results showed that the three devices have proportional response with
the air kerma; the energy dependence displayed for each device
suggests that some calibration factors would be applied for each one;
the angular dependence showed a similar pattern among the three
electronic components. In respect to the fourth parameter analyzed,
one phototransistor has the highest sensitivity however it also showed
the greatest loss of sensitivity with the accumulated dose. The
photodiode was the device with the smaller sensitivity to radiation,
on the other hand, the loss of sensitivity after irradiation is negligible.
Since high accuracy is a desired feature for a dosimeter, the
photodiode can be the most suitable of the three devices for
dosimetry in tomography. The phototransistors can also be used for
CT dosimetry, however it would be necessary a correction factor due
to loss of sensitivity with accumulated dose.
Abstract: The stereophotogrammetry modality is gaining more widespread use in the clinical setting. Registration and visualization of this data, in conjunction with conventional 3D volumetric image modalities, provides virtual human data with textured soft tissue and internal anatomical and structural information. In this investigation computed tomography (CT) and stereophotogrammetry data is acquired from 4 anatomical phantoms and registered using the trimmed iterative closest point (TrICP) algorithm. This paper fully addresses the issue of imaging artifacts around the stereophotogrammetry surface edge using the registered CT data as a reference. Several iterative algorithms are implemented to automatically identify and remove stereophotogrammetry surface edge outliers, improving the overall visualization of the combined stereophotogrammetry and CT data. This paper shows that outliers at the surface edge of stereophotogrammetry data can be successfully removed automatically.
Abstract: Discrete Wavelet Transform (DWT) has demonstrated
far superior to previous Discrete Cosine Transform (DCT) and
standard JPEG in natural as well as medical image compression. Due
to its localization properties both in special and transform domain,
the quantization error introduced in DWT does not propagate
globally as in DCT. Moreover, DWT is a global approach that avoids
block artifacts as in the JPEG. However, recent reports on natural
image compression have shown the superior performance of
contourlet transform, a new extension to the wavelet transform in two
dimensions using nonseparable and directional filter banks,
compared to DWT. It is mostly due to the optimality of contourlet in
representing the edges when they are smooth curves. In this work, we
investigate this fact for medical images, especially for CT images,
which has not been reported yet. To do that, we propose a
compression scheme in transform domain and compare the
performance of both DWT and contourlet transform in PSNR for
different compression ratios (CR) using this scheme. The results
obtained using different type of computed tomography images show
that the DWT has still good performance at lower CR but contourlet
transform performs better at higher CR.
Abstract: This paper presents a novel method for prediction of
the mechanical behavior of proximal femur using the general
framework of the quantitative computed tomography (QCT)-based
finite element Analysis (FEA). A systematic imaging and modeling
procedure was developed for reliable correspondence between the
QCT-based FEA and the in-vitro mechanical testing. A speciallydesigned
holding frame was used to define and maintain a unique
geometrical reference system during the analysis and testing. The
QCT images were directly converted into voxel-based 3D finite
element models for linear and nonlinear analyses. The equivalent
plastic strain and the strain energy density measures were used to
identify the critical elements and predict the failure patterns. The
samples were destructively tested using a specially-designed gripping
fixture (with five degrees of freedom) mounted within a universal
mechanical testing machine. Very good agreements were found
between the experimental and the predicted failure patterns and the
associated load levels.
Abstract: In this paper, algorithms for the automatic localisation
of two anatomical soft tissue landmarks of the head the medial
canthus (inner corner of the eye) and the tragus (a small, pointed,
cartilaginous flap of the ear), in CT images are describet. These
landmarks are to be used as a basis for an automated image-to-patient
registration system we are developing. The landmarks are localised
on a surface model extracted from CT images, based on surface
curvature and a rule based system that incorporates prior knowledge
of the landmark characteristics. The approach was tested on a dataset
of near isotropic CT images of 95 patients. The position of the
automatically localised landmarks was compared to the position of
the manually localised landmarks. The average difference was 1.5
mm and 0.8 mm for the medial canthus and tragus, with a maximum
difference of 4.5 mm and 2.6 mm respectively.The medial canthus
and tragus can be automatically localised in CT images, with
performance comparable to manual localisation
Abstract: As the Computed Tomography(CT) requires normally
hundreds of projections to reconstruct the image, patients are exposed
to more X-ray energy, which may cause side effects such as cancer.
Even when the variability of the particles in the object is very less,
Computed Tomography requires many projections for good quality
reconstruction. In this paper, less variability of the particles in an
object has been exploited to obtain good quality reconstruction.
Though the reconstructed image and the original image have same
projections, in general, they need not be the same. In addition
to projections, if a priori information about the image is known,
it is possible to obtain good quality reconstructed image. In this
paper, it has been shown by experimental results why conventional
algorithms fail to reconstruct from a few projections, and an efficient
polynomial time algorithm has been given to reconstruct a bi-level
image from its projections along row and column, and a known sub
image of unknown image with smoothness constraints by reducing the
reconstruction problem to integral max flow problem. This paper also
discusses the necessary and sufficient conditions for uniqueness and
extension of 2D-bi-level image reconstruction to 3D-bi-level image
reconstruction.
Abstract: Computed tomography and laminography are heavily investigated in a compressive sensing based image reconstruction framework to reduce the dose to the patients as well as to the radiosensitive devices such as multilayer microelectronic circuit boards. Nowadays researchers are actively working on optimizing the compressive sensing based iterative image reconstruction algorithm to obtain better quality images. However, the effects of the sampled data’s properties on reconstructed the image’s quality, particularly in an insufficient sampled data conditions have not been explored in computed laminography. In this paper, we investigated the effects of two data properties i.e. sampling density and data incoherence on the reconstructed image obtained by conventional computed laminography and a recently proposed method called spherical sinusoidal scanning scheme. We have found that in a compressive sensing based image reconstruction framework, the image quality mainly depends upon the data incoherence when the data is uniformly sampled.
Abstract: Liver segmentation is the first significant process for
liver diagnosis of the Computed Tomography. It segments the liver
structure from other abdominal organs. Sophisticated filtering techniques
are indispensable for a proper segmentation. In this paper, we
employ a 3D anisotropic diffusion as a preprocessing step. While
removing image noise, this technique preserve the significant parts
of the image, typically edges, lines or other details that are important
for the interpretation of the image. The segmentation task is done
by using thresholding with automatic threshold values selection and
finally the false liver region is eliminated using 3D connected component.
The result shows that by employing the 3D anisotropic filtering,
better liver segmentation results could be achieved eventhough simple
segmentation technique is used.
Abstract: Accurate timing alignment and stability is important
to maximize the true counts and minimize the random counts in
positron emission tomography So signals output from detectors must
be centering with the two isotopes to pre-operation and fed signals
into four units of pulse-processing units, each unit can accept up to
eight inputs. The dual source computed tomography consist two units
on the left for 15 detector signals of Cs-137 isotope and two units on
the right are for 15 detectors signals of Co-60 isotope. The gamma
spectrum consisting of either single or multiple photo peaks. This
allows for the use of energy discrimination electronic hardware
associated with the data acquisition system to acquire photon counts
data with a specific energy, even if poor energy resolution detectors
are used. This also helps to avoid counting of the Compton scatter
counts especially if a single discrete gamma photo peak is emitted by
the source as in the case of Cs-137. In this study the polyenergetic
version of the alternating minimization algorithm is applied to the
dual energy gamma computed tomography problem.