Abstract: Solid-state hydrogen storage using catalytically-modified porous silicon can be rapidly charged at moderate pressures (8 bar) without exothermic runaway. Discharge requires temperatures of approximately 110oC, so for larger storage vessels a means is required for thermal energy to penetrate bulk storage media. This can be realized with low-density metal foams, such as Celmet™. This study explores several material and dimensional choices of the metal foam to produce rapid heating of bulk silicon particulates. Experiments run under vacuum and in a pressurized hydrogen environment bracket conditions of empty and full hydrogen storage vessels, respectively. Curve-fitting of the heating profiles at various distances from an external heat source is used to derive both a time delay and a characteristic time constant. System performance metrics of a hydrogen storage subsystem are derived from the experimental results. A techno-economic analysis of the silicon and metal foam provides comparison with other methods of storing hydrogen for mobile and portable applications.
Abstract: The aim of this experimental and numerical study is to analyze the effects of acoustic streaming generated by 40 kHz ultrasonic waves on heat transfer in forced convection, with and without 40 PPI aluminum metal foam. Preliminary dynamic and thermal studies were done with COMSOL Multiphase, to see heat transfer enhancement degree by inserting a 40PPI metal foam (10 × 2 × 3 cm) on a heat sink, after having determined experimentally its permeability and Forchheimer's coefficient. The results obtained numerically are in accordance with those obtained experimentally, with an enhancement factor of 205% for a velocity of 0.4 m/s compared to an empty channel. The influence of 40 kHz ultrasound on heat transfer was also tested with and without metallic foam. Results show a remarkable increase in Nusselt number in an empty channel with an enhancement factor of 37,5%, while no influence of ultrasound on heat transfer in metal foam presence.
Abstract: Metallic foams have good potential for lightweight
structures for impact and blast mitigation. Therefore it is important to
find out the optimized foam structure (i.e. cell size, shape, relative
density, and distribution) to maximise energy absorption. In this
paper, quasistatic compression and microstructural characterization
of closed-cell aluminium foams of different pore size and cell
distributions have been carried out. We present results for two
different aluminium metal foams of density 0.49-0.51 g/cc and 0.31-
0.34 g/cc respectively that have been tested in quasi-static
compression. The influence of cell geometry and cell topology on
quasistatic compression behaviour has been investigated using optical
microscope and computed tomography (micro-CT) analysis. It is
shown that the deformation is not uniform in the structure and
collapse begins at the weakest point.