Abstract: In Jordan having deficit atmospheric precipitation, an
increase in water demand occurs during summer months. Jordan can
be regarded with a relatively high potential for wastewater recycling
and reuse. The main purpose of this paper was to investigate the
removal of total suspended solids (TSS) and chemical oxygen
demand (COD) for olive mill wastewater (OMW) by
electrocoagulation (EC) process. In the combination of
electrocoagulation by using coupled iron–aluminum electrodes, the
optimum working pH was found to be around 6. Results indicated
that the electrocoagulation process allowed removal of TSS and COD
of about 82.5% and 47.5%, respectively at 45 mA/cm2 after 70
minutes by using coupled iron–aluminum electrodes. It was
demonstrated that the maximum TSS and COD removals were
obtained at some optimum experimental parameters for current
density, pH, and reaction time.
Abstract: Diminished antioxidant defense or increased
production of reactive oxygen species in the biological system can
result in oxidative stress which may lead to various
neurodegenerative diseases including Alzheimer’s disease (AD).
Microglial activation also contributes to the progression of AD by
producing several proinflammatory cytokines, nitric oxide (NO) and
prostaglandin E2 (PGE2). Oxidative stress and inflammation have
been reported to be possible pathophysiological mechanisms
underlying AD. In addition, the cholinergic hypothesis postulates that
memory impairment in patient with AD is also associated with the
deficit of cholinergic function in the brain. Although a number of
drugs have been approved for the treatment of AD, most of these
synthetic drugs have diverse side effects and yield relatively modest
benefits. Marine algae have great potential in pharmaceutical and
biomedical applications as they are valuable sources of bioactive
properties such as anticoagulation, antimicrobial, antioxidative,
anticancer and anti-inflammatory. Hence, this study aimed to provide
an overview of the properties of Malaysian seaweeds (Padina
australis, Sargassum polycystum and Caulerpa racemosa) in
inhibiting oxidative stress, neuroinflammation and cholinesterase
enzymes. These seaweeds significantly exhibited potent DPPH and
moderate superoxide anion radical scavenging ability (P
Abstract: Particles exhausted from cars have adverse impacts on
human health. The study developed a three-dimensional particle
dispersion numerical model including particle coagulation to simulate
the particle concentration distribution under idling conditions in a
residential underground garage. The simulation results demonstrate
that particle disperses much faster in the vertical direction than that in
horizontal direction. The enhancement of particle dispersion in the
vertical direction due to the increase of cars with engine running is
much stronger than that in the car exhaust direction. Particle dispersion
from each pair of adjacent cars has little influence on each other in the
study. Average particle concentration after 120 seconds exhaust is
1.8-4.5 times higher than the initial total particles at ambient
environment. Particle pollution in the residential underground garage
is severe.
Abstract: Coagulation is a process that sanitizes leather effluents. It aims to reduce pollutants such as Chemical Oxygen Demand (COD), chloride, sulfate, chromium, suspended solids, and other dissolved solids. The current study aimed to evaluate coagulation efficiency of tannery wastewater by analyzing the change in organic matter, odor, color, ammonium ions, nutrients, chloride, H2S, sulfate, suspended solids, total dissolved solids, fecal pollution, and chromium hexavalent before and after treatment. Effluent samples were treated with coagulants Ca(OH)2 and FeSO4 .7H2O. The best advantages of this treatment included the removal of: COD (81.60%); ammonia ions (98.34%); nitrate ions (92%); chromium hexavalent (75.00%); phosphate (70.00%); chloride (69.20%); and H₂S (50%). Results also indicated a high level of efficiency in the reduction of fecal pollution indicators. Unfortunately, only a modest reduction of sulfate (19.00%) and TSS (13.00%) and an increase in TDS (15.60%) was observed.
Abstract: Conventional coagulation, advance oxidation process (AOPs), and the combined process were evaluated and compared for its suitability to treat the stabilized cutting-oil wastewater. The 90% efficiency was obtained from the coagulation at Al2(SO4)3 dosage of 150 mg/L and pH 7. On the other hands, efficiencies of AOPs for 30 minutes oxidation time were 10% for acoustic oxidation, 12% for acoustic oxidation with hydrogen peroxide, 76% for Fenton, and 92% sono-Fenton processes. The highest efficiency for effective oil removal of AOPs required large amount of chemical. Therefore, AOPs were studied as a post-treatment after conventional separation process. The efficiency was considerable as the effluent COD can pass the standard required for industrial wastewater discharge with less chemical and energy consumption.
Abstract: Magnesium chloride, though cost wise roughly same as of ferrous sulphate, is less commonly used coagulant in comparison to the ferrous sulphate for the treatment of wastewater. The present study was conducted to investigate the comparative effectiveness of ferrous sulphate (FeSO4.7H2O) as iron based salt and magnesium chloride (MgCl2) as magnesium based salt in terms of decolorization and chemical oxygen demand (COD) reduction efficiency of textile wastewater. The coagulants were evaluated for synthetic textile wastewater containing two diazo dyes namely Reactive Black 5 (RB5) and Congo Red (CR) and one anthraquinone dye as Disperse Blue 3 (DB3), in seven possible equi-ratio combinations. Other chemical constituents that are normally released from different textile processing units were also added to replicate a practical scenario. From this study, MgCl2/Lime was found to be a superior coagulant system as compared to FeSO4.7H2O/Lime, FeSO4.7H2O/NaOH and MgCl2/NaOH.
Abstract: This paper describes the research carried out to develop a process to increase the NaCl percentage of crude salt which is obtained from the conventional solar evaporation process. In this study refined salt was produced from crude solar salt by a chemico-physical method which consists of coagulation, precipitation and filtration. Initially crude salt crystals were crushed and dissolved in water. Optimum amounts of calcium hydroxide, sodium carbonate and Polyaluminiumchloride (PAC) were added to the solution respectively.
Refined NaCl solution was separated out by a filtration process. The solution was tested for Total Suspended Solids, SO42-, Mg2+, Ca2+. With optimum dosage of reagents, the results showed that a level of 99.60% NaCl could be achieved. Further this paper discusses the economic viability of the proposed process. A 83% profit margin can be achieved by this process and it is an increase of 112.3% compared to the traditional process.
Abstract: Synthetic oily wastewaters were prepared from metal working fluids (MWF). Electrocoagulation experiments were performed under constant voltage application. The current, conductivity, pH, dissolved oxygen concentration and temperature were recorded on line at every 5 seconds during the experiments. Effects of applied voltage differences, electrode materials and distance between electrodes on removal efficiency have been investigated. According to the experimental results, the treatment of MWF wastewaters by iron electrodes rather than aluminum and stainless steel was much quicker; and the distance between electrodes should be less than 1cm. The electrocoagulation process was modeled by using block oriented approach and found out that it can be modeled as a single input and multiple output system. Modeling studies indicates that the electrocoagulation process has a nonlinear model structure.
Abstract: The objective of this study is to investigate the performance of the electrocoagulation process for color and COD removal in palm oil wastewater using a 10 L batch reactor. Iron was used as electrodes and the distance between electrodes was 2 cm. The effects of operating parameters: current voltage (6, 12 and 18 volt), reaction time (5, 15, 30, 45 and 60 min) and initial pH (4 and 9) of treatment efficiency were examine. The result showed that decolorization and COD removal efficiency increased with the increase in current voltage and reaction time. The proper condition for decolorization achieved at initial pH 4 and 9 were current voltage of 12 volt, reaction time 30 min. The decolorization efficiency reached 90.4% and 88.9%, respectively. COD removal was achiveved at current voltage 12 volt, reaction time 15 min. COD removal efficiency was 89.2 % and 83.0%, respectively. From the results, to show electrocoagulation process can treat palm oil mill wastewater in both acidic and basic condition at high efficiency for color and COD removal. Consequently, electrocoagulation process can be used or applied as a post-treatment step to improve the quality of the final discharge in term of color and residual COD removal.
Abstract: Treatment of tar-containing wastewater is necessary
for the successful operation of biomass gasification plants (BGPs). In
the present study, tar-containing wastewater was treated using lime
and alum for the removal of in-organics, followed by adsorption on
powdered activated carbon (PAC) for the removal of organics. Limealum
experiments were performed in a jar apparatus and activated
carbon studies were performed in an orbital shaker. At optimum
concentrations, both lime and alum individually proved to be capable
of removing color, total suspended solids (TSS) and total dissolved
solids (TDS), but in both cases, pH adjustment had to be carried out
after treatment. The combination of lime and alum at the dose ratio
of 0.8:0.8 g/L was found to be optimum for the removal of inorganics.
The removal efficiency achieved at optimum
concentrations were 78.6, 62.0, 62.5 and 52.8% for color, alkalinity,
TSS and TDS, respectively. The major advantages of the lime-alum
combination were observed to be as follows: no requirement of pH
adjustment before and after treatment and good settleability of
sludge. Coagulation-precipitation followed by adsorption on PAC
resulted in 92.3% chemical oxygen demand (COD) removal and
100% phenol removal at equilibrium. Ammonia removal efficiency
was found to be 11.7% during coagulation-flocculation and 36.2%
during adsorption on PAC. Adsorption of organics on PAC in terms
of COD and phenol followed Freundlich isotherm with Kf = 0.55 &
18.47 mg/g and n = 1.01 & 1.45, respectively. This technology may
prove to be one of the fastest and most techno-economically feasible
methods for the treatment of tar-containing wastewater generated
from BGPs.
Abstract: Neonatal lupus erythematous (NLE) is a rare disease marked by clinical characteristic and specific maternal autoantibody. Many cutaneous, cardiac, liver, and hematological manifestations could happen with affect of one organ or multiple. In this case, both babies were premature, low birth weight (LBW), small for gestational age (SGA) and born through caesarean section from a systemic lupus erythematous (SLE) mother. In the first case, we found a baby girl with dyspnea and grunting. Chest X ray showed respiratory distress syndrome (RDS) great I and echocardiography showed small atrial septal defect (ASD) and ventricular septal defect (VSD). She also developed anemia, thrombocytopenia, elevated C-reactive protein, hypoalbuminemia, increasing coagulation factors, hyperbilirubinemia, and positive blood culture of Klebsiella pneumonia. Anti-Ro/SSA and Anti-nRNP/sm were positive. Intravenous fluid, antibiotic, transfusion of blood, thrombocyte concentrate, and fresh frozen plasma were given. The second baby, male presented with necrotic tissue on the left ear and skin rashes, erythematous macula, athropic scarring, hyperpigmentation on all of his body with various size and facial haemorrhage. He also suffered from thrombocytopenia, mild elevated transaminase enzyme, hyperbilirubinemia, anti-Ro/SSA was positive. Intravenous fluid, methyprednisolone, intravenous immunoglobulin (IVIG), blood, and thrombocyte concentrate transfution were given. Two cases of neonatal lupus erythematous had been presented. Diagnosis based on clinical presentation and maternal auto antibody on neonate. Organ involvement in NLE can occur as single or multiple manifestations.
Abstract: The pulp and paper mill effluent is one of the high
polluting effluent amongst the effluents obtained from polluting
industries. All the available methods for treatment of pulp and paper
mill effluent have certain drawbacks. The coagulation is one of the
cheapest process for treatment of various organic effluents. Thus, the
removal of chemical oxygen demand (COD) and colour of paper mill
effluent is studied using coagulation process. The batch coagulation
process was performed using various coagulants like: aluminium
chloride, poly aluminium chloride and copper sulphate. The initial
pH of the effluent (Coagulation pH) has tremendous effect on COD
and colour removal. Poly aluminium chloride (PAC) as coagulant
reduced COD to 84 % and 92 % of colour was removed at an
optimum pH 5 and coagulant dose of 8 ml l-1. With aluminium
chloride at an optimum pH = 4 and coagulant dose of 5 g l-1, 74 %
COD and 86 % colour removal were observed. The results using
copper sulphate as coagulant (a less commercial coagulant) were
encouraging. At an optimum pH 6 and mass loading of 5 g l-1, 76 %
COD reduction and 78 % colour reduction were obtained. It was also
observed that after addition of coagulant, the pH of the effluent
decreases. The decrease in pH was highest for AlCl3, which was
followed by PAC and CuSO4. Significant amount of COD reductions
was obtained by coagulation process. Since the coagulation process
is the first stage for treatment of effluent and some of the coagulant
cations usually remain in the treated effluents. Thus, cation like
copper may be one of the good catalyst for second stage of treatment
process like wet oxidation. The copper has been found to be good
oxidation catalyst then iron and aluminum.
Abstract: This study presents an investigation of
electrochemical variables and an application of the optimal
parameters in operating a continuous upflow electrocoagulation
reactor in removing dye. Direct red 23, which is azo-based, was used
as a representative of direct dyes. First, a batch mode was employed
to optimize the design parameters: electrode type, electrode distance,
current density and electrocoagulation time. The optimal parameters
were found to be iron anode, distance between electrodes of 8 mm
and current density of 30 A·m-2 with contact time of 5 min. The
performance of the continuous upflow reactor with these parameters
was satisfactory, with >95% color removal and energy consumption
in the order of 0.6-0.7 kWh·m-3.
Abstract: The electrochemical coagulation of a kaolin
suspension was investigated at the currents of 0.06, 0.12, 0.22, 0.44,
0.85 A (corresponding to 0.68, 1.36, 2.50, 5.00, 9.66 mA·cm-2,
respectively) for the contact time of 5, 10, 20, 30, and 50 min. The
TSS removal efficiency at currents of 0.06 A, 0.12 A and 0.22 A
increased with the amount of iron generated by the sacrificial anode,
while the removal efficiencies did not increase proportionally with
the amount of iron generated at the currents of 0.44 and 0.85 A,
where electroflotation was clearly observed. Zeta potential
measurement illustrated the presence of the highly positive charged
particles created by sorption of highly charged polymeric metal
hydroxyl species onto the negative surface charged kaolin particles at
both low and high applied currents. The disappearance of the
individual peaks after certain contact times indicated the attraction
between these positive and negative charged particles causing
agglomeration. It was concluded that charge neutralization of the
individual species was not the only mechanism operating in the
electrocoagulation process at any current level, but electrostatic
attraction was likely to co-operate or mainly operate.
Abstract: Natural organic matter (NOM) is heterogeneous
mixture of organic compounds that enter the water media from
animal and plant remains, domestic and industrial wastes.
Researches showed that NOM is likely precursor material for
disinfection by products (DBPs). Chlorine very commenly used for
disinfection purposes and NOM and chlorine reacts then
Trihalomethane (THM) and Haloacetic acids (HAAs) which are
cancerogenics for human health are produced. The aim of the study is
to search NOM removal by enhanced coagulation from drinking
water source of Eskisehir which is supplied from Porsuk Dam.
Recently, Porsuk dam water is getting highly polluted and therefore
NOM concentration is increasing. Enhanced coagulation studies were
evaluated by measurement of Dissolved Organic Carbon (DOC), UV
absorbance at 254 nm (UV254), and different trihalomethane
formation potential (THMFP) tests. Results of jar test experiments
showed that NOM can be removed from water about 40-50 % of
efficiency by enhanced coagulation. Optimum coagulant type and
coagulant dosages were determined using FeCl3 and Alum.
Abstract: In this study arsenate [As(V)] removal from drinking water by coagulation process was investigated. Ferric chloride (FeCl3.6H2O) and ferrous sulfate (FeSO4.7H2O) were used as coagulant. The effects of major operating variables such as coagulant dose (1–30 mg/L) and pH (5.5–9.5) were investigated. Ferric chloride and ferrous sulfate were found as effective and reliable coagulant due to required dose, residual arsenate and coagulant concentration. Optimum pH values for maximum arsenate removal for ferrous sulfate and ferric chloride were found as 8 and 7.5. The arsenate removal efficiency decreased at neutral and acidic pH values for Fe(II) and at the high acidic and high alkaline pH for Fe(III). It was found that the increase of coagulant dose caused a substantial increase in the arsenate removal. But above a certain ferric chloride and ferrous sulfate dosage, the increase in arsenate removal was not significant. Ferric chloride and ferrous sulfate dose above 8 mg/L slightly increased arsenate removal.
Abstract: A mathematical model for the hydrodynamics of a
surface water treatment pilot plant was developed and validated by
the determination of the residence time distribution (RTD) for the
main equipments of the unit. The well known models of ideal/real
mixing, ideal displacement (plug flow) and (one-dimensional axial)
dispersion model were combined in order to identify the structure
that gives the best fitting of the experimental data for each equipment
of the pilot plant. RTD experimental results have shown that pilot
plant hydrodynamics can be quite well approximated by a
combination of simple mathematical models, structure which is
suitable for engineering applications. Validated hydrodynamic
models will be further used in the evaluation and selection of the
most suitable coagulation-flocculation reagents, optimum operating
conditions (injection point, reaction times, etc.), in order to improve
the quality of the drinking water.
Abstract: Von Willebrand-s disease is the most common
inherited bleeding disorder in humans, it
caused by qualitative abnormalities of the von Willebrand factor
(vWF). Our objective is to determine the prevalence of this disease at
part of the Algerian population in the East and the South by a
biological diagnosis based on specific biological tests (automated
platelet count, the bleeding time (TS), the time of cephalin + activator
(TCA), measure of the prothrombin rate (TP), vWF rate and factor
VIII rate, Molecular electrophoresis of vWF multimers in agarose gel
in the presence of SDS). Four patients of type III or severe
Willebrand-s disease were found on 200 suspect cases. All cases are
showed a deficit in vWF rate (< 5%), and factor VIII (P
Abstract: Hepatitis C is an infectious disease transmitted by
blood and due to hepatitis C virus (HCV), which attacks the liver.
The infection is characterized by liver inflammation (hepatitis) that is
often asymptomatic but can progress to chronic hepatitis and later
cirrhosis and liver cancer. Our problem tends to highlight on the one
hand the prevalence of infectious disease in the population of the
region of Batna and on other hand the biological characteristics of
this disease by a screening and a specific diagnosis based on
serological tests, liver checkup (measurement of haematological and
biochemical parameters).
The results showed:
The serology of hepatitis C establishes the diagnosis of infection
with hepatitis C. In this study and with the serological test, 24 cases
of the disease of hepatitis C were found in 1000 suspected cases (7
cases with normal transaminases and 17 cases with elevated
transaminases). The prevalence of this disease in this study
population was 2.4%.
The presence of hepatitis C disrupts liver function including the
onset of cytolysis, cholestasis, jaundice, thrombocytopenia, and
coagulation disorders.
Abstract: Following the research in the Department of environmental engineering in Faculty of mechanical engineering on Technical University of Kosice and experiences with electrocoagulation style of disposal waste water, there were designed and partly examining the equipment of two stage revitalization on the standing and little fusible water of tenet electrolysis on the little tarns. With the cooperation with vet experts was that manners prove and it is innocuous for animals, during which time cyanobacteria are totally paralyzed. For the implementation of science and research results have been obtained by means EU funds for structural development.