Abstract: A prevalence cohort study of atherosclerotic lesions within cadavers was performed to better understand and characterize the prevalence of atherosclerosis among Georgia residents within body donors in the Philadelphia College of Osteopathic Medicine (PCOM) - Georgia body donor program. We procured specimens from cadavers used for medical student, physical therapy student, and biomedical science student cadaveric anatomical dissection at PCOM - South Georgia and PCOM - Georgia. Tissues were prepared using hematoxylin and eosin (H&E) stain as histological slides by Colquitt Regional Medical Center Laboratory Services. One section from each of the following arteries was taken after cadaveric dissection at the site of most calcification palpated grossly (if present): left anterior descending coronary artery, left internal carotid artery, abdominal aorta, splenic artery, and hepatic artery. All specimens were graded and categorized according to the American Heart Association’s Modified and Conventional Standards for Atherosclerotic Lesions using x4, x10, x40 microscopic magnification. Our study cohort included 22 cadavers, with 16 females and 6 males. The average age was 72.54 and median age was 72, with a range of 52 to 90 years old. The cause of death determination listing vascular and/or cardiovascular causes were present on 6 of the 22 death certificates. 19 of 22 (86%) cadavers had at least a single artery grading > 5. Of the cadavers with at least a single artery graded at greater than 5, only 5 of 19 (26%) cadavers had a vascular or cardiovascular cause of death reported. Malignancy was listed as a cause of death on 7 (32%) of death certificates. The average atherosclerosis grading of the common hepatic, splenic and left internal carotid arteries (2.15, 3.05, and 3.36 respectively) were lower than the left anterior descending artery and the abdominal aorta (5.16 and 5.86 respectively). This prevalence study characterizes atherosclerosis found in five medium and large systemic arteries within cadavers from the state of Georgia.
Abstract: Background: Breast cancer is the leading cause of death for women around the world. Screening mammography is the reference examination, due to its sensitivity for detecting small lesions and micro-calcifications. Therefore, it is essential to ensure quality mammographic examinations with the most optimal dose. These conditions depend on the choice of exposure parameters. Clinically, practices must be evaluated in order to determine the most appropriate exposure parameters. Material and Methods: We performed our measurements on a mobile mammography unit (PLANMED Sofie-classic.) in Morocco. A solid dosimeter (AGMS Radcal) and a MTM 100 phantom allow to quantify the delivered dose and the image quality. For image quality assessment, scores are defined by the rate of visible inserts (MTM 100 phantom), obtained and compared for each acquisition. Results: The results show that the parameters of the mammography unit on which we have made our measurements can be improved in order to offer a better compromise between image quality and breast dose. The last one can be reduced up from 13.27% to 22.16%, while preserving comparable image quality.
Abstract: In this paper, we report the experimental results on using complementary Golay coded signals at 7.5 MHz to detect breast microcalcifications of 50 µm size. Simulations using complementary Golay coded signals show perfect consistence with the experimental results, confirming the improved signal to noise ratio for complementary Golay coded signals. For improving the success on detecting the microcalcifications, orthogonal complementary Golay sequences having cross-correlation for minimum interference are used as coded signals and compared to tone burst pulse of equal energy in terms of resolution under weak signal conditions. The measurements are conducted using an experimental ultrasound research scanner, Digital Phased Array System (DiPhAS) having 256 channels, a phased array transducer with 7.5 MHz center frequency and the results obtained through experiments are validated by Field-II simulation software. In addition, to investigate the superiority of coded signals in terms of resolution, multipurpose tissue equivalent phantom containing series of monofilament nylon targets, 240 µm in diameter, and cyst-like objects with attenuation of 0.5 dB/[MHz x cm] is used in the experiments. We obtained ultrasound images of monofilament nylon targets for the evaluation of resolution. Simulation and experimental results show that it is possible to differentiate closely positioned small targets with increased success by using coded excitation in very weak signal conditions.
Abstract: Cancer affects people globally with breast cancer being a leading killer. Breast cancer is due to the uncontrollable multiplication of cells resulting in a tumour or neoplasm. Tumours are called ‘benign’ when cancerous cells do not ravage other body tissues and ‘malignant’ if they do so. As mammography is an effective breast cancer detection tool at an early stage which is the most treatable stage it is the primary imaging modality for screening and diagnosis of this cancer type. This paper presents an automatic mammogram classification technique using wavelet and Gabor filter. Correlation feature selection is used to reduce the feature set and selected features are classified using different decision trees.
Abstract: Computer aided diagnosis systems provide vital
opinion to radiologists in the detection of early signs of breast cancer
from mammogram images. Architectural distortions, masses and
microcalcifications are the major abnormalities. In this paper, a
computer aided diagnosis system has been proposed for
distinguishing abnormal mammograms with architectural distortion
from normal mammogram. Four types of texture features GLCM
texture, GLRLM texture, fractal texture and spectral texture features
for the regions of suspicion are extracted. Support vector machine
has been used as classifier in this study. The proposed system yielded
an overall sensitivity of 96.47% and an accuracy of 96% for
mammogram images collected from digital database for screening
mammography database.
Abstract: Mammography has been one of the most reliable
methods for early detection of breast cancer. There are different
lesions which are breast cancer characteristic such as
microcalcifications, masses, architectural distortions and bilateral
asymmetry. One of the major challenges of analysing digital
mammogram is how to extract efficient features from it for accurate
cancer classification. In this paper we proposed a hybrid feature
extraction method to detect and classify all four signs of breast
cancer. The proposed method is based on multiscale surrounding
region dependence method, Gabor filters, multi fractal analysis,
directional and morphological analysis. The extracted features are
input to self adaptive resource allocation network (SRAN) classifier
for classification. The validity of our approach is extensively
demonstrated using the two benchmark data sets Mammographic
Image Analysis Society (MIAS) and Digital Database for Screening
Mammograph (DDSM) and the results have been proved to be
progressive.
Abstract: Clusters of Microcalcifications (MCCs) are most frequent symptoms of Ductal Carcinoma in Situ (DCIS) recognized by mammography. Least-Square Support Vector Machine (LS-SVM) is a variant of the standard SVM. In the paper, LS-SVM is proposed as a classifier for classifying MCCs as benign or malignant based on relevant extracted features from enhanced mammogram. To establish the credibility of LS-SVM classifier for classifying MCCs, a comparative evaluation of the relative performance of LS-SVM classifier for different kernel functions is made. For comparative evaluation, confusion matrix and ROC analysis are used. Experiments are performed on data extracted from mammogram images of DDSM database. A total of 380 suspicious areas are collected, which contain 235 malignant and 145 benign samples, from mammogram images of DDSM database. A set of 50 features is calculated for each suspicious area. After this, an optimal subset of 23 most suitable features is selected from 50 features by Particle Swarm Optimization (PSO). The results of proposed study are quite promising.
Abstract: For the improvement of the ability in detecting
small calcifications using Ultrasonography (US) we propose a
novel indicator of calcifications in an ultrasound B-mode image
without decrease in frame rate. Since the waveform of an
ultrasound pulse changes at a calcification position, the
decorrelation of adjacent scan lines occurs behind a
calcification. Therefore, we employ the decorrelation of
adjacent scan lines as an indicator of a calcification. The
proposed indicator depicted wires 0.05 mm in diameter at 2 cm
depth with a sensitivity of 86.7% and a specificity of 100%,
which were hardly detected in ultrasound B-mode images. This
study shows the potential of the proposed indicator to
approximate the detectable calcification size using an US
device to that of an X-ray imager, implying the possibility that
an US device will become a convenient, safe, and principal
clinical tool for the screening of breast cancer.
Abstract: The activities of alkaline phosphatase and Ca2+ATPase in mud crab (Scylla serrata) collected from a soft-shell crab farm in Chantaburi Province, Thailand, in several stages of molting cycle were observed. The results showed that the activity of alkaline phosphatase in gill after molting was highly significant (p
Abstract: Calcite aCalcite and aragonite are the two common
polymorphs of CaCO3 observed as biominerals. It is universal that
the sea water contents a high Mg2+ (50mM) relative to Ca2+ (10mM).
In vivo crystallization, Mg2+ inhibits calcite formation. For this
reason, stony corals skeleton may be formed only aragonite crystals
in the biocalcification. It is special in case of soft corals of which
formed only calcite crystal; however, this interesting phenomenon,
still uncharacterized in the marine environment, has been explored in
this study using newly purified cell-free proteins isolated from the
endoskeletal sclerites of soft coral. By recording the decline of pH in
vitro, the control of CaCO3 nucleation and crystal growth by the cellfree
proteins was revealed. Using Atomic Force Microscope, here we
find that these endoskeletal cell-free proteins significantly design the
morphological shape in the molecular-scale kinetics of crystal
formation and those proteins act as surfactants to promote ion
attachment at calcite steps.nd aragonite are the two common polymorphs of CaCO3 observed as biominerals. It is universal that the sea water contents a high Mg2+ (50mM) relative to Ca2+ (10mM). In vivo crystallization, Mg2+ inhibits calcite formation. For this reason, stony corals skeleton may be formed only aragonite crystals in the biocalcification. It is special in case of soft corals of which formed only calcite crystal; however, this interesting phenomenon, still uncharacterized in the marine environment, has been explored in this study using newly purified cell-free proteins isolated from the endoskeletal sclerites of soft coral. By recording the decline of pH in vitro, the control of CaCO3 nucleation and crystal growth by the cell-free proteins was revealed. Using Atomic Force Microscope, here we find that these endoskeletal cell-free proteins significantly design the morphological shape in the molecular-scale kinetics of crystal formation and those proteins act as surfactants to promote ion attachment at calcite steps. KeywordsBiomineralization, Calcite, Cell-free protein, Soft coral
Abstract: This paper presents an approach for early breast
cancer diagnostic by employing combination of artificial neural
networks (ANN) and multiwaveletpacket based subband image
decomposition. The microcalcifications correspond to high-frequency
components of the image spectrum, detection of microcalcifications
is achieved by decomposing the mammograms into different
frequency subbands,, reconstructing the mammograms from the
subbands containing only high frequencies. For this approach we
employed different types of multiwaveletpacket. We used the result
as an input of neural network for classification. The proposed
methodology is tested using the Nijmegen and the Mammographic
Image Analysis Society (MIAS) mammographic databases and
images collected from local hospitals. Results are presented as the
receiver operating characteristic (ROC) performance and are
quantified by the area under the ROC curve.
Abstract: Clusters of microcalcifications in mammograms are an
important sign of breast cancer. This paper presents a complete
Computer Aided Detection (CAD) scheme for automatic detection of
clustered microcalcifications in digital mammograms. The proposed
system, MammoScan μCaD, consists of three main steps. Firstly
all potential microcalcifications are detected using a a method for
feature extraction, VarMet, and adaptive thresholding. This will also
give a number of false detections. The goal of the second step,
Classifier level 1, is to remove everything but microcalcifications.
The last step, Classifier level 2, uses learned dictionaries and sparse
representations as a texture classification technique to distinguish
single, benign microcalcifications from clustered microcalcifications,
in addition to remove some remaining false detections. The system
is trained and tested on true digital data from Stavanger University
Hospital, and the results are evaluated by radiologists. The overall
results are promising, with a sensitivity > 90 % and a low false
detection rate (approx 1 unwanted pr. image, or 0.3 false pr. image).
Abstract: An effective method for the early detection of breast
cancer is the mammographic screening. One of the most important
signs of early breast cancer is the presence of microcalcifications. For
the detection of microcalcification in a mammography image, we
propose to conceive a multiagent system based on a dual irregular
pyramid.
An initial segmentation is obtained by an incremental approach;
the result represents level zero of the pyramid. The edge information
obtained by application of the Canny filter is taken into account to
affine the segmentation. The edge-agents and region-agents cooper
level by level of the pyramid by exploiting its various characteristics
to provide the segmentation process convergence.
Abstract: Texture classification is an important image processing
task with a broad application range. Many different techniques for
texture classification have been explored. Using sparse approximation
as a feature extraction method for texture classification is a relatively
new approach, and Skretting et al. recently presented the Frame
Texture Classification Method (FTCM), showing very good results on
classical texture images. As an extension of that work the FTCM is
here tested on a real world application as detection of abnormalities
in mammograms. Some extensions to the original FTCM that are
useful in some applications are implemented; two different smoothing
techniques and a vector augmentation technique. Both detection of
microcalcifications (as a primary detection technique and as a last
stage of a detection scheme), and soft tissue lesions in mammograms
are explored. All the results are interesting, and especially the results
using FTCM on regions of interest as the last stage in a detection
scheme for microcalcifications are promising.
Abstract: A mammography image is composed of low contrast area where the breast tissues and the breast abnormalities such as microcalcification can hardly be differentiated by the medical practitioner. This paper presents the application of active contour models (Snakes) for the segmentation of microcalcification in mammography images. Comparison on the microcalcifiation areas segmented by the Balloon Snake, Gradient Vector Flow (GVF) Snake, and Distance Snake is done against the true value of the microcalcification area. The true area value is the average microcalcification area in the original mammography image traced by the expert radiologists. From fifty images tested, the result obtained shows that the accuracy of the Balloon Snake, GVF Snake, and Distance Snake in segmenting boundaries of microcalcification are 96.01%, 95.74%, and 95.70% accuracy respectively. This implies that the Balloon Snake is a better segmentation method to locate the exact boundary of a microcalcification region.
Abstract: X-ray mammography is the most effective method for
the early detection of breast diseases. However, the typical diagnostic
signs such as microcalcifications and masses are difficult to detect
because mammograms are of low-contrast and noisy. In this paper, a
new algorithm for image denoising and enhancement in Orthogonal
Polynomials Transformation (OPT) is proposed for radiologists to
screen mammograms. In this method, a set of OPT edge coefficients
are scaled to a new set by a scale factor called OPT scale factor. The
new set of coefficients is then inverse transformed resulting in
contrast improved image. Applications of the proposed method to
mammograms with subtle lesions are shown. To validate the
effectiveness of the proposed method, we compare the results to
those obtained by the Histogram Equalization (HE) and the Unsharp
Masking (UM) methods. Our preliminary results strongly suggest
that the proposed method offers considerably improved enhancement
capability over the HE and UM methods.
Abstract: Breast cancer detection techniques have been reported
to aid radiologists in analyzing mammograms. We note that most
techniques are performed on uncompressed digital mammograms.
Mammogram images are huge in size necessitating the use of
compression to reduce storage/transmission requirements. In this
paper, we present an algorithm for the detection of
microcalcifications in the JPEG2000 domain. The algorithm is based
on the statistical properties of the wavelet transform that the
JPEG2000 coder employs. Simulation results were carried out at
different compression ratios. The sensitivity of this algorithm ranges
from 92% with a false positive rate of 4.7 down to 66% with a false
positive rate of 2.1 using lossless compression and lossy compression
at a compression ratio of 100:1, respectively.
Abstract: In this study, a new and fast algorithm for Ascending
Aorta (AscA) and Descending Aorta (DesA) segmentation is
presented using Computed Tomography Angiography images. This
process is quite important especially at the detection of aortic
plaques, aneurysms, calcification or stenosis. The applied method has
been carried out at four steps. At first step, lung segmentation is
achieved. At the second one, Mediastinum Region (MR) is detected
to use in the segmentation. At the third one, images have been
applied optimal threshold and components which are outside of the
MR were removed. Lastly, identifying and segmentation of AscA and
DesA have been carried out. The performance of the applied method
is found quite well for radiologists and it gives enough results to the
surgeries medically.